Chiller tripping problem.Compressor tripping in Chiller | Chiller compressor checking video in Hindi

Поділитися
Вставка
  • Опубліковано 15 вер 2024

КОМЕНТАРІ • 24

  • @intakhabalam3377
    @intakhabalam3377 4 дні тому +1

    Good explanation

  • @ViewofUAE
    @ViewofUAE 21 день тому

    Nice information

  • @numanmirza9584
    @numanmirza9584 21 день тому

    Nice vedio

    • @HVACBYREHAN
      @HVACBYREHAN  20 днів тому +1

      Thanks bhai ☺️☺️

    • @HVACBYREHAN
      @HVACBYREHAN  20 днів тому +1

      Wo video delete kar diya hai bhai jisme aapne recommend kiya tha mujhe

    • @numanmirza9584
      @numanmirza9584 20 днів тому +1

      @@HVACBYREHAN noo problem

  • @ShahzadShah-wn1ue
    @ShahzadShah-wn1ue 15 днів тому +1

    Bhai apne conection nahi khole shayd cabel kahi body pr tuch to nahi ho Rahi jisse compressor ground bta rha ho

    • @HVACBYREHAN
      @HVACBYREHAN  15 днів тому

      @@ShahzadShah-wn1ue Sahi kaha aapne bhai but isko humne disconnect krke check kiya hai uske baad compressor hi ground hua hai.
      Agar wire ke sath kuch issue hota hai most probably 1 ya 2 wire ke sath ground show karta hai ek sath bahot kam chance hota hai ground hone ka aur agar wire exposed ho chuki hai to wire ki resistance value me kaafi farq aata hai

    • @ShahzadShah-wn1ue
      @ShahzadShah-wn1ue 15 днів тому

      Wapas video dekha tab pta chla conection nikal rakhe hai ok nice information bhai

    • @ShahzadShah-wn1ue
      @ShahzadShah-wn1ue 15 днів тому

      Mera ek 3 phase ka compressor hai denfose 22 ton ka compressor ki value bhi clammetter me sahi compressor ground bhi nahi hai fir bhi 10 second me fuse utha deta hai

  • @Candlestar45
    @Candlestar45 14 днів тому +1

    Ground kya hota hai

    • @sktecn1490
      @sktecn1490 12 днів тому

      Arth ko ground bolte bhai

    • @HVACBYREHAN
      @HVACBYREHAN  11 днів тому

      Jab koi winding earth ke sath show kare (short hone ke bad) to wo ground ya earth leakage kaha jaata hai
      Ground ya earth ki ek value hoti hai agar us value se zyada earth show hoga to bhi issue hota hai

  • @khanpathan7516
    @khanpathan7516 10 днів тому +1

    Bhai cold 😢ka semi hermetic compressor hai 134a gass hai suction 18 psi hai Amp 40 barabar leta hai sab thek hai pher bhi sone time 4 hours ke bad over load se trip Marta hai kya problem ho sakta hai

    • @HVACBYREHAN
      @HVACBYREHAN  10 днів тому

      @@khanpathan7516 Agar compressor overload se trip karta hai to compressor ko check kro over load ki resistance value bhi check kro
      Discharge pressure Kya aata hai poora unit trip hota hai ya only compressor ?
      High amps agar slowly ho rha hai to discharge me issue hai kahin na kahin

    • @khanpathan7516
      @khanpathan7516 10 днів тому

      Ok Bhai thanks for reply total 5 indoor hai 2 freezer hai 3 cooler hai +15 ke sirf compressor overtime load se trip Marta hai kabhi 3 ghante bad kabhi 6 ghante bad

    • @khanpathan7516
      @khanpathan7516 10 днів тому

      Bhai overload ki value kaise nikalte hai pls reply

    • @khanpathan7516
      @khanpathan7516 7 днів тому +1

      Bhai suction 18 psi hai discharge 230 hai gass 134a discharge ok hai

    • @HVACBYREHAN
      @HVACBYREHAN  7 днів тому +1

      @@khanpathan7516 R134a 234 zyada nhi hai ??