I am also give knowledge about fire and safety. I really inspire to you. Great explanation .great knowledge. Keep it up brother. Your channel will be successful one day insha Allah.
Bro thank so much aap ne fault locate kaise karna bahut ache se bataya. Bro Noise fault kya hota hai loop mein aur is ko identify aur rectify kaise karte hain pls. batayein... Thank u.
The sensor inside the trench area is activated due to dust/debris and then actuators is get activated .then what u suggest in that situation.location of fm200 is LV Room
Dear sir... mera panel simplex 4100es hai. Panel ke men board se .. Aux se ek cable fire command centre ko gya hai aur waha par urth faltu dikha Raha hai, mere panel simplex me nahi..Aisa kyu.. aur kya karna hoga..
Yes sure very soon. Currently i am working on FM200 video series. Once it will completed i will make videos on Addressable fire alarm system & troubleshooting & designing
Nice Sir jii
Thanks dear 👍
ua-cam.com/video/Qj-uNUjZr0U/v-deo.html
My Latest video
Please subscribe my channel for such video 👍
FM200 PPM Video
ua-cam.com/video/t1RLfdKJOg4/v-deo.html
Water Leak Detection System
ua-cam.com/video/Y4ZeFd9T4Jk/v-deo.html
Number 1. Mai abhi ak prblm solve kia..
From qatar..love u sir♥️
Great
Hi Ansari, You are doing so nice job. Your explanation and clarity is very good and it helps lot to fire alarm technician. Thanks a lot.
Thanks a lot, Please share my videos in your company group
I am also give knowledge about fire and safety. I really inspire to you. Great explanation .great knowledge. Keep it up brother. Your channel will be successful one day insha Allah.
Thank you so much
FM200 PPM Video
ua-cam.com/video/t1RLfdKJOg4/v-deo.html
Bro thank so much aap ne fault locate kaise karna bahut ache se bataya. Bro Noise fault kya hota hai loop mein aur is ko identify aur rectify kaise karte hain pls. batayein... Thank u.
Noise fault, aysa koi fault m ny ab tak face nhi kiya....
Great . 👍 please make actual live site/field videos also for practical understanding. Thanks .
I will try my best
The sensor inside the trench area is activated due to dust/debris and then actuators is get activated .then what u suggest in that situation.location of fm200 is LV Room
Thanks for your comment
I think you have to install heat detector to prevent from false alarm. Or else clean detector on regular intervals...
Ek hi line me smoke ur heat detector laga sakte hi kya
Yes.
i want to know how to clear high resistance fault in gent vigilon
Dear sir... mera panel simplex 4100es hai. Panel ke men board se .. Aux se ek cable fire command centre ko gya hai aur waha par urth faltu dikha Raha hai, mere panel simplex me nahi..Aisa kyu.. aur kya karna hoga..
Nice sir ji.. please make more vedio on fas realtea
Thanks for your comment 😊
Kya wire Chhota padane pe agar jodate hai to kya groun fual ayega
Avoid cable joining. Use insulated connector & lugs to avoid ground fault
Detector ka connection kon sa terminal par karte he in out
Honeywell and simplex
Bataye sir pls
Honeywell ka toh video bananaya h n my, pls check my video list.....
Battary wiring fault ke bareme kuch batao sir
Please check this video
ua-cam.com/video/jAhrw0YInds/v-deo.html
Professional and dedicated video
Thanks for your comment dear ☺️
FM200 Gas Release Panel Commissioning
ua-cam.com/video/RaWbIHt-kTk/v-deo.html
FM200 | Ravel RE-25AR Panel wiring 🔥
ua-cam.com/video/_6q0ursNZa4/v-deo.html
Ek baat smjh ni aayi sir,1 to 5 agar check krenge to wiring kaise end krenge? Kya EOL se?
Jabki 6 to 10 inactive rhenge.
Ek baar video fir sy dhekiye doubt clear hojayega
Good very very good 🤗😍
Thanks for your comment 🙂
Bro do u provide any pd of this course
No i don't have, pls watch videos & make a not for your understanding
Types of detector or working principal par ek video bna do plz.
Ok sure
Same que.pls.
FM200 PPM Video
ua-cam.com/video/t1RLfdKJOg4/v-deo.html
Water Leak Detection System
ua-cam.com/video/Y4ZeFd9T4Jk/v-deo.html
FM200 Gas Release Panel Commissioning
ua-cam.com/video/RaWbIHt-kTk/v-deo.html
When you will make ur next video on Zeta and gent fire control panel as a (addressble )........
Yes sure very soon.
Currently i am working on FM200 video series. Once it will completed i will make videos on Addressable fire alarm system & troubleshooting & designing
I will make videos on ground fault troubleshooting in Addressable fire alarm systems.
FM200 PPM Video
ua-cam.com/video/t1RLfdKJOg4/v-deo.html
Owesome info...
Thanks for your comment
Please share video in your group
Great sir u
Thank you so much
Agr addressable panel hy to kasy check kary gy us ki wire to return panel me ja rahi hoti hy. Please guid me.
Thanks for your comment.
Uska bhi m ek video banaoga.
Addressble panel k liye return wire ko Panel m sy nikal dyny ka or fir same process..
FM200 PPM Video
ua-cam.com/video/t1RLfdKJOg4/v-deo.html
Water Leak Detection System
ua-cam.com/video/Y4ZeFd9T4Jk/v-deo.html
FM200 Gas Release Panel Commissioning
ua-cam.com/video/RaWbIHt-kTk/v-deo.html
FM200 | Ravel RE-25AR Panel wiring 🔥
ua-cam.com/video/_6q0ursNZa4/v-deo.html
Sir af shilled ki penil pi vedio bandado
R.R. Great sir u
Thank you so much
Sir fire alarm ko reset kaise karte hai..vedio banaye plz
kon sy panel ko reset karna hai or kon sa trouble hai
bro where is part 2 for faults and really appreciate ur work bro
Thanks for your comment
FAS Fault Part 1
ua-cam.com/video/jAhrw0YInds/v-deo.html
Thanks for your comment
FAS Fault Part 1
ua-cam.com/video/jAhrw0YInds/v-deo.html
I will make video on faults & troubleshooting in addressble fire system
Water Leak Detection System
ua-cam.com/video/Y4ZeFd9T4Jk/v-deo.html
Must Watch
Addressable WLD Layout | Step By Step Understanding
ua-cam.com/video/BCQ2Y-Cr3FI/v-deo.html
Smoke detector, MCP aur fire panel ki wiring par video banao pls
Ok i will try to make video on said topic.
Please check my videos. I have explained sd/mcp connection
ua-cam.com/video/PqEcDnkN-zQ/v-deo.html
Weldone
Thanks, pls share my videos in your company group
@@Ansari29 ok
Smps means
Switch mode power supply (DC Supply)
@@Ansari29 thanks for reply
Sir make video for beam detector and repeater panel
nice
Thanks for your comment
Explain smoke detector work system
Please check this video
ua-cam.com/video/PqEcDnkN-zQ/v-deo.html
FM200 PPM Video
ua-cam.com/video/t1RLfdKJOg4/v-deo.html
Water Leak Detection System
ua-cam.com/video/Y4ZeFd9T4Jk/v-deo.html
FM200 | Ravel RE-25AR Panel wiring 🔥
ua-cam.com/video/_6q0ursNZa4/v-deo.html
Ground fault aa rha hai fir ja rha he ese kese solve kare
Check in panel circuit board
And sir mughe gulf me job karni hai mughe 4 saal ka experience hai
Apply on gulf naukri.com & check assignment abroad news paper every Wednesday
Open skt ki