    My solution - inverter is symetric (Fronius), charget Go-E gemini flex charger 22kW. All I need to do is generate one MQTT message - how much solar is generating and how much do I take from/return to grid. The go-e will then calculate how much it can use and set the allowed current accordingly. On go-e you can even set the "threshold" - how much grid feed-in there needs to be before it even charges at all and how much grid feed should it keep - to make sure it does not charge the car from the grid.
    Works fully locally, no external API dependency, etc. Absolutely recommended.

    • @LittleSpot
      @LittleSpot 3 місяці тому

      I'm looking for exact this solution. Is there a tutorial for this somewhere in the web or can you explain it a little bit more? How fast is the polling/switching time of the goe charger? How long does it take adapt to a new charge current?

  • @Klaus-macht-Bilder_de
    @Klaus-macht-Bilder_de 3 місяці тому +1

    Interesting project - I did a similar project on an ABL-Wallbox which needed generic RS482-communication - which made the part of "talking" to the WB more complicated.
    I decided to uses MQTT for the WB-Communication and Node Red for the programming part.
    Our EV is a VW eUP that is capable for max. 2phase charging only - so so far a switch between 2 and 3 phase charging is not covered yet.
    On the WB I had the same situation, that the manuals offer to install the WB either for 1 or 3 phase charging (2-phase not mentioned. I implemented an standard 3x40A relais to interrupt phase 2 & 3 and a Shelly 3EM mainly for measurement. The relais of the Shelly is used to switch between 1 and 3 phase operation (via the 40A-Relais) - so no mode where I cant disconnect all phases. Thes was not documented anywhere but at least for load free switch between the modes thsi woks fine meanwhile for 3 years.
    I use this chance between 1 and more phases manual only by looking at the sky and the weather conditions. For my car I found, that it stopps charcing when charging is interrupted ~ more than 10 times and an day with individual clouds all trys with and automation for that switched much too often.
    For the balance between car and houses battery charging I calculate a reserve value of Watts depending on the house battery SOC. Further I definded a helper for a 2nd reserve power that can be modified between -3000 and + 3000 in 250W steps.This two reserve values and the house consumption were combined to determin how much PV power is available for car charging.
    Big advantage of that slider is e.g. if you know that the car is uses some hours during the day the power can be adjusted to use some house battery power that can betopped up after the car left.
    Here a link to a German description klaus-macht-bilder.blogspot.com/2021/09/steuerung-der-abl-emh1-wallbox-mit-home.html

  • @DavidTelesPortugal
    @DavidTelesPortugal 3 місяці тому

    I also have a pulsar plus. I have a automation running on nodered to adjust the charging current based on the current consumption and the max power I have. I only have 6.9Kw available on my apartment and since the wallbox is on the garage a couple of floors down, I have a powerline to provide internet to the garage and then I have a Shelly EM on the main fuse box reading the consumption from the garage and the total consumption. It works well, never had the power trip due to over consumption

  • @volkhen0
    @volkhen0 2 місяці тому

    Here in Poland we have 1h balancing so it doesn’t matter if you take power for half hour and send power for half hour - it’s important to have the sum equal 0kWh. The same for 3 phases. You pay for the sum of them. So you can load 1 phase 2,4kW and send 2,4kW on L2 and you will still have 0kWh at the end of the hour. This simplified the setup a lot. In great scale this all averages over many users so it doesn’t matter for the grid.

    • @bruxy70
      @bruxy70  2 місяці тому +1

      You’re lucky. Here it is a struggle, and it is getting worse.

    • @volkhen0
      @volkhen0 2 місяці тому

      @@bruxy70 the only problem is that we have so much solar now that the prices they pay us while sending the power to the grid is really low. It’s hourly price and sometimes it reaches 0.

    • @bruxy70
      @bruxy70  2 місяці тому

      @volkhen0 Here they pay virtually nothing, and some make import more expensive if you have solars. So the only strategy is to maximize own consumption and minimize import. This is why energy management is so important.

    • @volkhen0
      @volkhen0 2 місяці тому

      @@bruxy70 I look with great envy at your systems. I dream about such setup but I’m just a simple Arduino guy and honestly this is too much for me, maybe one day I will get knowledge required to build it.

  • @PatrickFelstead
    @PatrickFelstead 3 місяці тому

    I have a Fronius solar inverter, and the Fronius WattPilot EV charger. They communicate with each other and the WattPilot ECO mode ensures charge current (power) uses only excess solar power. Works like a charm, no Home Assistant automation or script is necessary.

    • @PatrickFelstead
      @PatrickFelstead 3 місяці тому

      The WattPolit automatically switches between 1-phase and 3-phase. It's minimum is 1.4kW.

  • @jonbraathen2232
    @jonbraathen2232 2 місяці тому +2

    You got the wrong EVSE.
    The Go-e Gemini 11/22kW changes automatically between 1 and 3 phase and you can control all parameters easily from Home Assistant 😊

    • @Matushke
      @Matushke 9 днів тому +1

      so how does that work exactly? You calculate the solar surplus in HomeAssistant and you'll just pass that value to go-e filed for Charging power? Will Go-e automatically calculate how many phases and Amperage need to meet that surplus?

  • @jamiehiggs5389
    @jamiehiggs5389 14 днів тому

    Great video but I just have a zappi and it does all of this automatically even phase switching so much less headache

  • @kolarikrichard8550
    @kolarikrichard8550 2 місяці тому

    Trochu bych Vás opravil ve výkonech 3f rozvodů, počítat výkon 3f rozvodu jako 3x240 x proud je poněkud zavádějící (pokud se nejedná o zapojení do trojúhelníku, ale nevím proč by se takto uměle snižoval nabíjecí příkon,) vzhledem k tomu že napětí v 3f rozvodech v Evropě je 400V na fázi vypadá příkon asi trochu jinak než uvádíte (asi takto: P=3 x Uf x I x cosφ , s tím, že cosφ je jak známo účinník tedy fázový posun mezi napětím a proudem závislý na typu zátěže, což asi lze pro zjednodušení zanedbat takže P=3 x 400 x i a z toho plyne pro 11kW proud 9,166A na fázi)

  • @ITtechnerd
    @ITtechnerd 2 місяці тому

    I’m using easee charger and with this i have full control on the api and there is a hacs for home assistant for it. So i use node red to control if i want to use sun or grid and which phase i want to use. We have 240 on each phase in Denmark. Let me know if you want to have more info on it.

  • @tiagomello
    @tiagomello 3 місяці тому

    Mr White? Is that you?

  • @_v_e_c_t_o_r_
    @_v_e_c_t_o_r_ 3 місяці тому

    Why don't you use evcc?

  • @tonyjairus
    @tonyjairus 3 місяці тому

    Hi, nice work, searching for similar solution myself, what inverter do u use? And wallbox?

    • @bruxy70
      @bruxy70  3 місяці тому

      I have Goodwe 10K ET+. And Wallbox Pulsar Plus.

  • @DethpickleDave
    @DethpickleDave 3 місяці тому

    Is wallbox a generic name for an EVSE? Or do you have a Wallbox brand EVSE like the Wallbox Pulsar Plus or something?

    • @bruxy70
      @bruxy70  3 місяці тому

      The integration is for the Wallbox brand. I have Pulsar Plus. There are other wallboxes you can manage, e.g. through OCPP. Some others by sending them 1-10V analog input. But the one I got has native HA support

    • @DethpickleDave
      @DethpickleDave 3 місяці тому +1

      @@bruxy70 thanks! I must have missed the details on the actual unit if you said it.
      I also have the Pulsar Plus and am running the HA integration. I’ve also experienced it just not working sometimes. Didn’t realize it was a polling limit.

    • @bruxy70
      @bruxy70  3 місяці тому

      @DethpickleDave I did not have such issue yet