Hand mode me drive auto me start stop nahi hoga, kewal vfd ke display se start stop hoga . Auto mode me vfd ke display se start stop nahi hoga, kewal auto me start stop hoga jaise HMI display, remote controll
Iske liye aap ko ek settings karna hai, P10 pe 0 set karne ke baad, EXTRAS me jake OK presh karke , DOWN key ek baar presh karne par RAM to ROM likh kar aaega, uspe 2 baar OK presh karna hai, waha per busy likh kar aaega khuch der intijar karne ke baad, ESC key ko presh karte huwe back chale aana hai.
if there is coming proper voltage 415 volt, both three phase, then there is a internal problem in power module(I think IGBT has been damaged) please check the internal terminal of power module with multimeter
Cross means If any fault is found, the inverter will be shut down and the user It is necessary to take necessary corrective action to clean it up. The situation is that the inverter will not shut down. For example, high temperature.
Excellent job 😇
Thanks
Super good job
Thank you so much
Nice Brother 🎉🎉🎉
Excellent work
Thank you
Nice
❤
Very useful video but apne P2000 bare me nhi bataya
Delta vfd c2000 ka vedio banay sir
Abhi to mere paas Delta ka vfd nahi hai, jaub hoga to video upload kar denge
Helo sir
Excellent and I want how to commission of drive through starter software
Thanks for the comment, I will upload video on it soon.
Sir , Analog current output to plc (4-20mA) parramitter setting Kiya hai?
P322
Aur P1032
Same he hai kya
same nahi hai
F1662 fault in Siemens Sinamics PM 240 ..please help
P0311 how to check
In this video we have told how to check P03 11
Di/Do to batao (r722.0.....)
From BOP to BOP per video digye
Ok, I will try to upload a video on it soon.
Sir hand aur auto mode me kya difference hota hai
Hand mode me drive auto me start stop nahi hoga, kewal vfd ke display se start stop hoga .
Auto mode me vfd ke display se start stop nahi hoga, kewal auto me start stop hoga jaise HMI display, remote controll
Siemens Pm240-2 me start command ka parameter kon sa hai
P0015 - Macro drive unit
select( 2-wire 1) set 17
Sir parameter download kaise kare kisse bhee drive ka please help me
Aap apne drive ka moddel number or Company name bhejiye, may aap ko link bhej dunga
@@rvelectricalguide 6sl3210 1pe18 oul1
P310 me 50 hz set karte hai to 30hz running dikhata hai. And 60 hz pe 60 hz running dikhata hai. Konsa parameters check kare
Cheak P0322 Maximum Motor speed kitna hai?
Solve this problem thank you
Bhai ji mujhe simens g 120 ko do mode me chalana hai...D0 high krne per 0-10volt reference and D0+D1 high krne per fixed speed per chalani h
Jaise hi mere pass G120 vfd available ho jaega, aapko video ke jariye bata denge
how you fix ramp up 9 sec ,is there any calculations for 9 sec ?
There is no any calculation,You can set as per your requirement.
Sir p10 parameter 0 karne ke bad me power of karke on karne pe p10 1 ho jata hai.
Iske liye aap ko ek settings karna hai,
P10 pe 0 set karne ke baad,
EXTRAS me jake OK presh karke ,
DOWN key ek baar presh karne par RAM to ROM likh kar aaega, uspe 2 baar OK presh karna hai, waha per busy likh kar aaega khuch der intijar karne ke baad, ESC key ko presh karte huwe back chale aana hai.
Iske baad drive ko off or on karke cheak kariye.
Agar sahi hota hai to ,ek baar jarur bataiyega haumko
@@rvelectricalguide ok
Ok it's working ok thank you.
You welcome
Hi sir, please help me, F7802 😢
First of all check the input ,supply and tell me
if there is coming proper voltage 415 volt, both three phase, then there is a internal problem in power module(I think IGBT has been damaged) please check the internal terminal of power module with multimeter
Display per cross ka Symbol ring m show ker raha hai ye kya hai
Cross means If any fault is found, the inverter will be shut down and the user
It is necessary to take necessary corrective action to clean it up. The situation is that the inverter will not shut down.
For example, high temperature.
Fault F7801 pz help
Cheak P305 Rated motor current?
P640 current limit?
P1120 Ramp up time?
And also check the motor resistance by multimeter
Sab sahi aata hai but phir bhi trip ho raha hai
Motor kW 75 rpm 1450,ampr 132, or parameters 640 me 155 ampr hai
Ramp up time or ramp down time kitna hai?
Pura parameters aata hai
Kaun sa parameter ka jankari lena chahte hai?
Sir apka no. Mil skta ha
Motor id
It will be set Zero
@@rvelectricalguide p10... 0 start programs
Siemens g120 vfd cooling fan set temperature parameter bataein.
Parameter number p0295 par Jakar set kar sakte hai
Is there any option to see the only the parameters, its value changed from its default value.
For default value you see in manual parameter
Hii apka what's app no.milega
Helo sir