Earthed Cable vs Unearthed Cable| Types of Cable| Cable Insulation | Hindi

Поділитися
Вставка
  • Опубліковано 10 лют 2025
  • Queries Solved:
    1. Earthed cable vs Unearthed cable.
    2. Earthed system vs Unearthed System.
    3. Types of cable.
    4. What is NGR.
    5. Neutral Grounding Resistance.
    6. Insulation in Electrical cable.
    7. HT cable
    Hello Friends in this video we discussed about the difference between earthed cable and unearthed cable in the simplest way possible.
    About Channel:
    In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
    #Cable #Types
    Kindly subscribe.
    Thank you.

КОМЕНТАРІ • 73

  • @Parihar1986
    @Parihar1986 3 роки тому

    Sir aap ke video Dekh k knowledge improve Hota h .thanks sir

  • @sanjayjoshi6618
    @sanjayjoshi6618 8 місяців тому +1

    Thanks Bhai Great,mujhe aapke other video dekhena hai ,even I will recommend others

  • @sandipzode4730
    @sandipzode4730 3 роки тому +1

    Sir ur doing grate work for us

  • @Radhac369
    @Radhac369 4 роки тому +1

    Keep it up .to provide knowledge is the best dead .

  • @arunjoshi2089
    @arunjoshi2089 4 роки тому +1

    Good 👍

  • @sabnavis51
    @sabnavis51 3 роки тому

    Abhishek, am going through all your posts. Each one is highly educative. It gives me a great Brushing up of my knowledge in our Filed of Electrical engineering. I have retired almost a decade ago & enjoying going through all your posts. All the Best . Take Care.
    I am SABNAVIS from Hyderabad.

  • @CulturalyCuriousPallavi
    @CulturalyCuriousPallavi 4 роки тому +2

    Nice Video 👍👍

  • @narendrasingh9157
    @narendrasingh9157 2 роки тому

    Good Learning

  • @avinashingale7389
    @avinashingale7389 3 роки тому +1

    Thanks Abhishek for all the videos that you’ve made. Can you make videos of Electrical motor installation, Panel installation, transformer installation etc. basically installation procedure of all electrical equipment???

  • @PradeepPandey-lg8jn
    @PradeepPandey-lg8jn Рік тому

    Too nice explanation....

  • @roshanrajurkar6015
    @roshanrajurkar6015 4 роки тому +1

    Thanks sir giving helpful information.

  • @rakeshpaliwal3422
    @rakeshpaliwal3422 3 роки тому

    Excellent explanation

  • @laxmikant8973
    @laxmikant8973 4 роки тому

    Thank U so much sir for making helpful videos..

  • @ZahidHussain-wk1zl
    @ZahidHussain-wk1zl Рік тому

    Hi Dear , Thank you for such a great info in simple language,
    Which type of Cable should consider for 1x1000sqmm 66kV cable

  • @satyavara6276
    @satyavara6276 4 роки тому

    Good explanation

  • @bijaybehera3894
    @bijaybehera3894 3 роки тому

    Thank you for this video

  • @sanjupali2023
    @sanjupali2023 2 місяці тому +1

    Sir kiya delta configuration un earthed system hai?

  • @swapnilparab5446
    @swapnilparab5446 3 роки тому

    Very helpful

  • @mohankumar-bt4jn
    @mohankumar-bt4jn 2 роки тому

    Please do video on stability

  • @pardeeppsiingh7068
    @pardeeppsiingh7068 4 роки тому

    Very nice

  • @lokeshtembhre6077
    @lokeshtembhre6077 6 місяців тому

    Thanks sir

  • @santoshyadav-om3oe
    @santoshyadav-om3oe 4 роки тому +1

    Super

  • @nishikantasahu4273
    @nishikantasahu4273 3 роки тому

    Thank you

  • @sanjayjoshi6618
    @sanjayjoshi6618 8 місяців тому

    joshi sir,how it is different from armred, unarmared cable

  • @rituraj6889
    @rituraj6889 3 роки тому

    👍👍

  • @ravinder1250
    @ravinder1250 4 роки тому

    Thanks sir 👍

  • @AMITKUMAR-wv7nv
    @AMITKUMAR-wv7nv 4 роки тому

    Sir grid substation me lage equipment pr bhi video banaye plz...

  • @himanshutiwari3219
    @himanshutiwari3219 4 роки тому

    Please make more pure industrial videos ( Cement)

  • @ranakb6708
    @ranakb6708 4 роки тому

    Directional over current relay ke bare me bataye sir

  • @bhupeshmurkute6780
    @bhupeshmurkute6780 2 роки тому

    Sir how N GTR will work in electrical system

  • @shrinibaspatel4849
    @shrinibaspatel4849 2 роки тому

    Sir 220 v DC db main positive k saath erth ko voltage measure karne se 110kyun dekhata hai usi bare main thoda samjhadejiye

  • @muhammadfawad662
    @muhammadfawad662 3 роки тому

    Respected Sir, Please explain Electrical Thermography Testing?

  • @ashutoshsharma9066
    @ashutoshsharma9066 4 роки тому

    Sir,
    Does "shunt relay" in acb give protection from overload and short circuit ?

  • @sandeepkothavade5206
    @sandeepkothavade5206 10 місяців тому

    I have come across one application where voltage level is 3.3 KV (UE)
    And its is in CHP (coal handling plant)
    Now I want to select the cable (HT) plz suggest the which type of cable I have to select?

  • @roshanrajurkar6015
    @roshanrajurkar6015 4 роки тому

    Sir please make a grid resistance starters in HT motor.

  • @Freeman-il8rl
    @Freeman-il8rl 3 роки тому +1

    please explain, why voltage increases in other phases by 1.7 times during earth fault ?

  • @schoolhalchal4975
    @schoolhalchal4975 Рік тому

    Please give the example of use of nonearthed cable and for which purpose the neutral of generator and Transformer are not provided with neutral... Please respond.

  • @mithileshtiwari5363
    @mithileshtiwari5363 4 роки тому

    Sir under voltage or shunt voltage ACB me kise lagye or elr me wiring kise kare .

  • @mallikarjunaraosutraye1076
    @mallikarjunaraosutraye1076 3 роки тому

    Thanku Sir ❤
    Why cable Armoured connect to the earth what is reasons for that?

  • @hemantshukla2314
    @hemantshukla2314 3 роки тому

    LT and HT ir value k bare me btaye

    • @shrikantsathe371
      @shrikantsathe371 3 роки тому

      Hemant ji, one important thing to remember while carrying IR check of electrical equipment that the output voltage of Insulation Resistance tester should not be more than the service voltage of the equipment which is to be checked.

  • @mahmudalabdullah8543
    @mahmudalabdullah8543 2 роки тому

    my question is related to NGR, if the neutral is earthed, how can any other phase touch that cable, are they not physically separated? if yes, then how can fault current from another phase travel to the neutral phase? thanks

  • @mzia854
    @mzia854 Рік тому

    Sir what is shielded cable?

  • @pgvvsmanil1811
    @pgvvsmanil1811 4 роки тому

    Sir,how to take meggar values for a HT CABLE and a SLIP RING INDUCTION MOTOR.

    • @shrikantsathe371
      @shrikantsathe371 3 роки тому +1

      Insulation resistance values of Electrical appliances or accessories is to be carried out as per IEEE 43-2

  • @indranildutta2550
    @indranildutta2550 3 роки тому

    धन्यवाद सर,
    सर, अर्थ वाली 1 कोर केवल और 3 कोर वाली केवल में जब हम किट भरते हैं तो दोनों सिरे से दो अर्थ कि स्ट्रिप निकलती है, क्या हमें दोनों सिरों को अर्थ करना चाहिए या दोनों का तरीका अलग है। कृपया जानकारी दिजिये सर।

    • @shrikantsathe371
      @shrikantsathe371 3 роки тому

      पॉवर केबल और कंट्रोल केबल का जब जोइंट किया जाता है तब अर्थ वाली रिब्बन को दोनो तरफ अर्थ करना है ! लेकीन कोई सिग्नल केबल का स्क्रीन जब अर्थ करना है तो सिर्फ किसी एकही तरफ ग्राऊंड करना है ! Thanks and Best Regards. Shrikant M. Sathe

  • @sivakumar-xe2qo
    @sivakumar-xe2qo 3 роки тому

    Sir please explain vector group tests in detail

  • @nikhilsreekumar5744
    @nikhilsreekumar5744 4 роки тому

    Sir MV drive???

  • @arvindkumarrajput8909
    @arvindkumarrajput8909 3 роки тому

    How voltage raised 1.7 times at the time of one phase earthen or faulty

    • @shrikantsathe371
      @shrikantsathe371 3 роки тому

      Dear Sir, Consider normal operation of cable wherein all three phase cores are properly separated from each other and Earth. If one of the core touches with ground i.e. armouring of the cable, say R phase. Then insulation of other 2 phases i.e. Y and B would become live at 415 Volts i.e. 1.732 times of usual voltage. Means, Y phase insulation is under pressure because of Y phase voltage internally through the conductor. Whereas, the same Y phase insulation would become under stressed because of R phase voltage externally through contact of the core with Y phase as well as may be with armoured of the cable. Thus, 1.732 times. Thanks And Best Regards. Shrikant M. Sathe

  • @PRABHUNATHVERMA-k7o
    @PRABHUNATHVERMA-k7o 5 днів тому

    Reason for motor burnt

  • @rishikeshkumar9312
    @rishikeshkumar9312 4 роки тому

    Sir motor ma pole ka kaya matlab

  • @pargatsingh-hp1tu
    @pargatsingh-hp1tu Рік тому

    HT cable dono end to earth hoti hi ja one said to 3 core cable

  • @piyushbagoria3890
    @piyushbagoria3890 3 роки тому

    Net se padhke?

  • @yaserbarrawaz
    @yaserbarrawaz 3 роки тому

    Whatever you told, you just confused the audience. First you should clear your concept.

  • @RK-rcm2025
    @RK-rcm2025 2 роки тому

    Good explanation