Earthed Cable vs Unearthed Cable| Types of Cable| Cable Insulation | Hindi
Вставка
- Опубліковано 10 лют 2025
- Queries Solved:
1. Earthed cable vs Unearthed cable.
2. Earthed system vs Unearthed System.
3. Types of cable.
4. What is NGR.
5. Neutral Grounding Resistance.
6. Insulation in Electrical cable.
7. HT cable
Hello Friends in this video we discussed about the difference between earthed cable and unearthed cable in the simplest way possible.
About Channel:
In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
#Cable #Types
Kindly subscribe.
Thank you.
Sir aap ke video Dekh k knowledge improve Hota h .thanks sir
Thanks Bhai Great,mujhe aapke other video dekhena hai ,even I will recommend others
Thank you Sanjay..
Sir ur doing grate work for us
Keep it up .to provide knowledge is the best dead .
Thank you...
Also watch playlist for videos related to Drawing, Calculation, Motor, Transformer, Power Factor Correction and many more..
Good 👍
Abhishek, am going through all your posts. Each one is highly educative. It gives me a great Brushing up of my knowledge in our Filed of Electrical engineering. I have retired almost a decade ago & enjoying going through all your posts. All the Best . Take Care.
I am SABNAVIS from Hyderabad.
Thank you so much Sir...🙏🙏
Nice Video 👍👍
Thank you...
Good Learning
Thanks Abhishek for all the videos that you’ve made. Can you make videos of Electrical motor installation, Panel installation, transformer installation etc. basically installation procedure of all electrical equipment???
Too nice explanation....
Thanks sir giving helpful information.
Most welcome Roshan..
Excellent explanation
Thank U so much sir for making helpful videos..
Hi Dear , Thank you for such a great info in simple language,
Which type of Cable should consider for 1x1000sqmm 66kV cable
Good explanation
Thank you for this video
Sir kiya delta configuration un earthed system hai?
Very helpful
Please do video on stability
Very nice
Thanks sir
Super
Thank you Santosh..
Thank you
joshi sir,how it is different from armred, unarmared cable
👍👍
Thanks sir 👍
Sir grid substation me lage equipment pr bhi video banaye plz...
Please make more pure industrial videos ( Cement)
Directional over current relay ke bare me bataye sir
Sir how N GTR will work in electrical system
Sir 220 v DC db main positive k saath erth ko voltage measure karne se 110kyun dekhata hai usi bare main thoda samjhadejiye
Respected Sir, Please explain Electrical Thermography Testing?
Sir,
Does "shunt relay" in acb give protection from overload and short circuit ?
I have come across one application where voltage level is 3.3 KV (UE)
And its is in CHP (coal handling plant)
Now I want to select the cable (HT) plz suggest the which type of cable I have to select?
Sir please make a grid resistance starters in HT motor.
please explain, why voltage increases in other phases by 1.7 times during earth fault ?
Same doubt
Please give the example of use of nonearthed cable and for which purpose the neutral of generator and Transformer are not provided with neutral... Please respond.
HT cable
@kharanshupathak5500 HT Cables also having earth wire with it
Sir under voltage or shunt voltage ACB me kise lagye or elr me wiring kise kare .
Thanku Sir ❤
Why cable Armoured connect to the earth what is reasons for that?
For system earthing
LT and HT ir value k bare me btaye
Hemant ji, one important thing to remember while carrying IR check of electrical equipment that the output voltage of Insulation Resistance tester should not be more than the service voltage of the equipment which is to be checked.
my question is related to NGR, if the neutral is earthed, how can any other phase touch that cable, are they not physically separated? if yes, then how can fault current from another phase travel to the neutral phase? thanks
Yes it short in 1 point
Sir what is shielded cable?
Sir,how to take meggar values for a HT CABLE and a SLIP RING INDUCTION MOTOR.
Insulation resistance values of Electrical appliances or accessories is to be carried out as per IEEE 43-2
धन्यवाद सर,
सर, अर्थ वाली 1 कोर केवल और 3 कोर वाली केवल में जब हम किट भरते हैं तो दोनों सिरे से दो अर्थ कि स्ट्रिप निकलती है, क्या हमें दोनों सिरों को अर्थ करना चाहिए या दोनों का तरीका अलग है। कृपया जानकारी दिजिये सर।
पॉवर केबल और कंट्रोल केबल का जब जोइंट किया जाता है तब अर्थ वाली रिब्बन को दोनो तरफ अर्थ करना है ! लेकीन कोई सिग्नल केबल का स्क्रीन जब अर्थ करना है तो सिर्फ किसी एकही तरफ ग्राऊंड करना है ! Thanks and Best Regards. Shrikant M. Sathe
Sir please explain vector group tests in detail
Sir MV drive???
How voltage raised 1.7 times at the time of one phase earthen or faulty
Dear Sir, Consider normal operation of cable wherein all three phase cores are properly separated from each other and Earth. If one of the core touches with ground i.e. armouring of the cable, say R phase. Then insulation of other 2 phases i.e. Y and B would become live at 415 Volts i.e. 1.732 times of usual voltage. Means, Y phase insulation is under pressure because of Y phase voltage internally through the conductor. Whereas, the same Y phase insulation would become under stressed because of R phase voltage externally through contact of the core with Y phase as well as may be with armoured of the cable. Thus, 1.732 times. Thanks And Best Regards. Shrikant M. Sathe
Reason for motor burnt
Sir motor ma pole ka kaya matlab
HT cable dono end to earth hoti hi ja one said to 3 core cable
Net se padhke?
Yes.
Net and books..
Whatever you told, you just confused the audience. First you should clear your concept.
Good explanation