  • @HamDX2LVG
    @HamDX2LVG 2 роки тому

    Job well done, all that trouble because of a plate bent and put on the wrong way. Currently have my rotator in bits as I watch this Vid but is nothing wrong with mine I am just a curious Ham that cant help taking things apart to see what goes on inside LOL. Found this most interesting and gave me a much more deeper undertanding of what was going on inside the rotator. Thank you so much!

    • @duoro-rotators
      @duoro-rotators  2 роки тому +1

      Thanks for the reply, The plate was not the main problem, that happened after when someone put it back together, WRONGLY.
      The main problem that started this whole process, was the BK butterfly being loose on the motor shaft, which is the main problem that happens to these rotators.

    • @HamDX2LVG
      @HamDX2LVG 2 роки тому

      ​@@duoro-rotators It is good to know some of the main problems that go wrong with these rotators and certainly helps problem solving. Good job!

  • @WilfMWLF
    @WilfMWLF Рік тому

    Would be good to see a video of the actual reassembly. strip down is easy but the rebuild would be good to see.

    • @duoro-rotators
      @duoro-rotators  Рік тому

      Thanks for the comment. Since this is my business & how I make my living, sorry I can not show all of the work that I do. That is what the customer would normally be paying for.

  • @norman-justerieyazon4819
    @norman-justerieyazon4819 Рік тому

    Hello there from California!!! I know this is off topic, im in a dilemma about my g450a, the trouble is when i try to activate and turn the rotator there is significant delay on the turning of the rotator, i have to push the forward and reverse controls of the controller a few times for rotator to start to turn. Maybe you can give me some ideas whats wrong with it. 9:50

    • @duoro-rotators
      @duoro-rotators  Рік тому

      Hi Norman, It is not off topic, as we a talking about Yaesu Rotators & the 450A most likely has the same problem as the G-1000 did in this video, as the utilise the same BK brake system. Yes there could be other problems, but the only way to find out 100% is to get it on the work bench & strip it down. For more detailed info please get in contact with me via my web site which is listed in the description. Peter

  • @raymondcostilla5908
    @raymondcostilla5908 8 місяців тому

    I had a problem after installing my G-1000 brake it would rotate by hand CCW and CW but would not rotate 360 deg. I finally got it right.
    I had to losen the rotor motor screws mount and realinged the thep nylon gear on the rotor shaft and it would now rotate freely. I thghtened up the motor mount screws. all good now. I also had to secure the set screw on the metal part that rotates inside the brake to the motor shaft which was loose. I previously for your help but will not need it..
    I would like you to do a detail demonstaation on video removing the brake and replacing the brake in detail for G-1000 rotor. N5KIR Ray

  • @omegaman1960p
    @omegaman1960p 9 місяців тому

    Is the spring required on the butterfly? I think this is my problem. Unit will rotate perfectly in the CCW direction; but not CW. Works fine without the spring. Any suggestions greatly appreciated. Great video(s), too!

    • @duoro-rotators
      @duoro-rotators  9 місяців тому +1

      Hi Perry, Thank you for the comment. The BK spring is part of the brake system & a MUST for the brake to work, without it you will have very low Brake Torque if any @ all. Please get in contact with me via my web site (which is in the description on the video) for more information.

  • @douglasandrie9314
    @douglasandrie9314 Рік тому

    What grease do you recommend for COLD Canadian winters?

    • @duoro-rotators
      @duoro-rotators  Рік тому +1

      Hi Douglas Thanks for the enquiry.
      Being in Australia, I normally use Molybdenum Disulfide grease however it's temp range is only -18°C to 316°C (0°F to 600°F) which @ a guess in NOT a lower enough temp range for Canada.
      You will have to find a grease locally that has lower temp rating.
      The main requirement for grease in a rotator are :- NOT to heavy, thick, sticky or stringy as these greases will have a binding up affect on the gears etc which puts a lot of load onto the small AC or DC motor causing other problems.

    • @douglasandrie9314
      @douglasandrie9314 Рік тому

      @@duoro-rotators Thanks very much! Enjoy your posts!

    • @mickwood4641
      @mickwood4641 9 місяців тому

      Hi hope you ok ... Regarding grease ... Would copper grease be ok ... Mike UK ...

  • @robsteenweg1517
    @robsteenweg1517 2 роки тому

    looking at how to install coil spring ITEM 18 into a G-1000 rotor is not shown in this otherwise excellent VIDEO.

    • @duoro-rotators
      @duoro-rotators  2 роки тому

      Hi Rob, Please get in contact with me (Peter of Duoro Services) via my web site (www.kur02.com.au). Thanking you Peter.

  • @davewilson9345
    @davewilson9345 Рік тому

    when putting back together how do you clock it or time it????

    • @duoro-rotators
      @duoro-rotators  Рік тому

      Hi Dave, Thank you for the comment. I guess you mean the alignment of the rotator. Sorry that is my job & how I make my living in this ever shrinking industry. Hence why I do not show that part of the reassembly. I get it that people want to do things them self. I have been working on rotators for years & taught me self how to work on these rotator. Problem with these rotator is if you don't align it properly you will do damage to the POT &/or it gearing etc. Regards Peter of Duoro services

    • @davewilson9345
      @davewilson9345 Рік тому

      @duoro-rotators really you won't help a guy, its all about the money right, I'm not surprised these days

    • @davewilson9345
      @davewilson9345 Рік тому

      @duoro-rotators how much money you want for the info? I will send it to you