Original Position Return (OPR) Mitsubishi Servo MR-J3-10B With QD75MH4 Positioning control | SOFTGOT

Поділитися
Вставка
  • Опубліковано 3 гру 2024

КОМЕНТАРІ • 17

  • @nguyenlong3497
    @nguyenlong3497 4 місяці тому +1

    so freaking dope bro. Luv u so much.

    • @automationliker
      @automationliker  4 місяці тому

      @@nguyenlong3497 Thanks For Watching This Video...

  • @kamalmunjal6380
    @kamalmunjal6380 5 місяців тому +1

    thanks for this tutorial, Request to please also prepare Near point dog and count method we need to learn the difference of all, this method only can teach to 0 OPR but physically machine not going to home position.

    • @automationliker
      @automationliker  5 місяців тому

      Thanks for watching this video...
      I will prepare for other OPR (HPR)..

  • @CuongLe-nj8kp
    @CuongLe-nj8kp 2 місяці тому +1

    Heyy Bro, I am a student, I am doing a project about Delta Robot, I also using QD75MH4 and I want set HOME for 3 SERVO. However, I don't know how to set for 3 SERVO at Zero Point at the same time. Thanks a lot

    • @automationliker
      @automationliker  2 місяці тому

      7:15 Make Parallel Program [MOV K9001 U0\G1600] For Axis 2 and [MOV K9001 U0\G1700] For Axis 3

    • @CuongLe-nj8kp
      @CuongLe-nj8kp 2 місяці тому +1

      @@automationliker thanks sir, I will try it

  • @Prashantborse1992
    @Prashantborse1992 24 дні тому +1

    Hello I need help for motor parameter tuning please help ?

    • @automationliker
      @automationliker  24 дні тому

      @@Prashantborse1992 use one touch tuning with MR Configurator2 Software

  • @CuongLe-nj8kp
    @CuongLe-nj8kp 2 місяці тому +1

    Heyy Bro, I will try it. I don''t know How to save data of OPR ? Because I want to push SET HOME button that Servo will back to the position that I was set when using Data Set Method OPR. Please help me. I'm really grateful you !

    • @automationliker
      @automationliker  2 місяці тому +1

      @@CuongLe-nj8kpthis OPR used to teach where zero servo Position.
      If you want like that, i think you must use Absolute Position and Choose Position 0um on Position address Parameter..
      Watch my Video absolute QD75MH4 for Detail tutorial

    • @CuongLe-nj8kp
      @CuongLe-nj8kp 2 місяці тому +1

      @@automationliker Can i use Pulse to define postition address Parameter not use unit UM?

    • @automationliker
      @automationliker  2 місяці тому

      Yes, you can..
      But, You must change paremeter unit to pulse

    • @CuongLe-nj8kp
      @CuongLe-nj8kp 2 місяці тому +1

      Oke. Thank you so much !

    • @Prashantborse1992
      @Prashantborse1992 24 дні тому +1

      Need help for setting tuning motor parameters