I was so confused by that 34.5 number. I kept calculating that 1 horsepower (550 lbs elevated 1 foot per second at g = 32.17 ft/s^2 or 745.7 watts) could only evaporate 2.62 lbs of water an hour and I couldn't figure out where I went wrong. Then eventually I figured out that a boiler horse power is not at all the same as a mechanical horsepower. That is so confusing, but I'm glad I understand it now even though it took hours of needless head banging.
Thanks for making these videos. Works been a little slow lately so I’ve been trying to do some learning watching a lot of these. They’re very informative and we’ll presented.
Hi Engineer❗️ How much heating surface area of a vertical water tube 3 pass boiler will be enough for my 200KW forced draft gas fired burner? •Tube diameter = 2.25"
Hey! Just wanted to let you know we just released a new Boiling Point on Feedwater economizers. ua-cam.com/video/bJmbhAC_xVM/v-deo.html Hopefully that answers questions you might have!
So if a customer explains that the continium transfunctioner is over heating which causes the flux compositor to expand rapidly. What could we use as far as formulas to find a solution?🤔
julian maldonado Just introduce a dab of Phozschmoo-Triborosnot through the stetsor valve intake. That'll calm things right down for ya. (Just be sure to flip the goddamitron to low first). No formula required, & works every time!
VERY helpful! I'm curious though, I was operating a coal fired 50hp single pass.locomotive style fire tube boiler. I need 150# steam to feed a 2" line intermittently. With water tube package boilers being more efficient than fire tube, does that alter the BHP that I need? Would the size of boiler that I need run off of 3ph or single phase? Since I am not using a DA tank for my current boiler, how much more space consideration am I looking at for a DA tank, feedwater pump, etc. as opposed to what is needed now? Obviously, I will need to convert to gas or oil (prefer gas), what would my gas supply demands be?
Whew! Here are the answers. The efficiency difference between watertube and firetube are minimal so the boiler size will not change so if you have a 50hp now then that is what you need to stick with unless you are sure of your steam load. A 50hp boiler can be designed to run off of 3ph or 1ph. With this size boiler either is sufficient. The DA tank/feedwater tank will have a footprint of approximately 24" W x 48" L x 72" T. For a 50hp boiler you would need 1psi of natural gas at a maximum flow rate of 2,000 SCFH. Let us know if you need any further assistance and Thanks for your comment!
You probably dont give a damn but does anyone know of a tool to log back into an Instagram account..? I stupidly forgot my password. I love any help you can offer me.
@Justice Nasir thanks for your reply. I got to the site through google and im waiting for the hacking stuff now. Seems to take a while so I will get back to you later when my account password hopefully is recovered.
Great video keep them coming you guys rock
I like how this was the first result despite including metric in my search term. Thanks youtube!
Thanks guys! These formulas come in handy - greatly appreciate it!!!
Glad we could help! Thanks for watching!
Enjoyed this segment very much!
Thanks for the comment!
شكرا لكم انها فيديو هات مفيدة للغاية.
How culculate boiler capacity through boiler heating surface?
How to calculate the burner and the stack mass flow
I was so confused by that 34.5 number. I kept calculating that 1 horsepower (550 lbs elevated 1 foot per second at g = 32.17 ft/s^2 or 745.7 watts) could only evaporate 2.62 lbs of water an hour and I couldn't figure out where I went wrong. Then eventually I figured out that a boiler horse power is not at all the same as a mechanical horsepower. That is so confusing, but I'm glad I understand it now even though it took hours of needless head banging.
Glad we could help out! Thanks for watching
Thanks for making these videos. Works been a little slow lately so I’ve been trying to do some learning watching a lot of these. They’re very informative and we’ll presented.
I'm confused , I have 21,500lbs of steam a hour at 155psi evaporation is 1.08 what is the answer
What’s the question?
ارجو الرد السريع لأنني.بحاجة للمعلومات .وانا سعيد بكم فضلا وليس امرا
what's the formula in calculating mass of fuel in a fire tube boiler? i need to know how many tons of fuel per hour my boiler consumes
Hi Engineer❗️
How much heating surface area of a vertical water tube 3 pass boiler will be enough for my 200KW forced draft gas fired burner?
•Tube diameter = 2.25"
Do you have a 1st Class Steam License
do you have videos related to feedwater economizers and flue gas condensing economizers?
We don't right now but that is something we can make sure to get on the schedule to film. Appreciate the comment and thanks for watching!
Hey! Just wanted to let you know we just released a new Boiling Point on Feedwater economizers. ua-cam.com/video/bJmbhAC_xVM/v-deo.html Hopefully that answers questions you might have!
So if a customer explains that the continium transfunctioner is over heating which causes the flux compositor to expand rapidly. What could we use as far as formulas to find a solution?🤔
Dude... Where's my car? 😂 Since these formulas are grounded in reality it might be hard to use them on anything else.. Thanks for watching!
julian maldonado
Just introduce a dab of Phozschmoo-Triborosnot through the stetsor valve intake. That'll calm things right down
for ya. (Just be sure to flip the goddamitron to low first). No formula required, & works every time!
اوريد أن أعرف مقاس المراجل البخار 2طن في الساعة بنسبة ل الطول والقطر والسماكات..وعدد الا انابيب المسار .وقياس الفرن والسماكة
VERY helpful! I'm curious though, I was operating a coal fired 50hp single pass.locomotive style fire tube boiler. I need 150# steam to feed a 2" line intermittently. With water tube package boilers being more efficient than fire tube, does that alter the BHP that I need? Would the size of boiler that I need run off of 3ph or single phase? Since I am not using a DA tank for my current boiler, how much more space consideration am I looking at for a DA tank, feedwater pump, etc. as opposed to what is needed now? Obviously, I will need to convert to gas or oil (prefer gas), what would my gas supply demands be?
Whew! Here are the answers.
The efficiency difference between watertube and firetube are minimal so the boiler size will not change so if you have a 50hp now then that is what you need to stick with unless you are sure of your steam load.
A 50hp boiler can be designed to run off of 3ph or 1ph. With this size boiler either is sufficient.
The DA tank/feedwater tank will have a footprint of approximately 24" W x 48" L x 72" T.
For a 50hp boiler you would need 1psi of natural gas at a maximum flow rate of 2,000 SCFH.
Let us know if you need any further assistance and Thanks for your comment!
You probably dont give a damn but does anyone know of a tool to log back into an Instagram account..?
I stupidly forgot my password. I love any help you can offer me.
@Kashton Peter instablaster =)
@Justice Nasir thanks for your reply. I got to the site through google and im waiting for the hacking stuff now.
Seems to take a while so I will get back to you later when my account password hopefully is recovered.
@Justice Nasir it worked and I finally got access to my account again. I am so happy!
Thanks so much, you really help me out :D
* it should be formulae in the title
I feel like making steam
ua-cam.com/video/Tek9976pfJc/v-deo.html Thanks for commenting!
👍👍
Slim sharpe
How culculate boiler capacity through boiler heating surface?