Recommended Blowdown Procedure for Boiler Level Instruments

Поділитися
Вставка
  • Опубліковано 4 січ 2025

КОМЕНТАРІ • 53

  • @sandiagocity2753
    @sandiagocity2753 3 роки тому +7

    Excellent way to describe blowdown procedure

  • @markrubino3262
    @markrubino3262 6 років тому +5

    Very clear and concise on how to do a blowdown!

  • @strikerj4810
    @strikerj4810 9 місяців тому

    Thanks this was very useful.

  • @ИгорьМихеенко-я4э
    @ИгорьМихеенко-я4э 5 місяців тому

    Good afternoon How do you feel about new technologies that are not similar to the current ones, based on a completely new principle of burning any fuel with clean emissions into the atmosphere?

  • @bharathk1487
    @bharathk1487 10 місяців тому +1

    Rice milli faire tube boiler videos

  • @rishipalsharma449
    @rishipalsharma449 Рік тому

    Very good information to you dear sir, thank you

  • @edwincosme1348
    @edwincosme1348 2 роки тому

    Videos on navian non 240

  • @thevijeta1470
    @thevijeta1470 5 років тому +1

    How to i know pipe is partially clogged

  • @sean2943
    @sean2943 Рік тому

    Great video, thanks.

  • @srinivasuluaandra319
    @srinivasuluaandra319 5 років тому +3

    Good explanation

  • @roymuhammadkhan7012
    @roymuhammadkhan7012 Рік тому

    I think 20 seconds is not enough in case of globe valves operation. They take time for full operation (full open or full close) and ball valves are not installed on the said circuit. Also in the case of globe valves, valves operating positions are not given in the video. Partial opening of the valve shall decrease the valve seat life.
    Curious, what to do?? 🧐🧐

    • @ClarkReliance
      @ClarkReliance  Рік тому

      1. If you have an installation with valves that may require more than 20 seconds to manipulate, you may have to exceed the recommended 20 second duration described in our procedure. However, the duration should be kept to a minimum amount of time. Our procedure is a guideline offered to assist operators with the majority of typical installations.
      2. Valve position is important to the operator. A trained operator should be educated on the valves in their particular boiler installations. Otherwise, they should seek guidance from the valve manufacturer.
      We thank you for your comments.
      If you have any other questions, feel free to email us at askus@clark-reliance.com.

    • @roymuhammadkhan7012
      @roymuhammadkhan7012 Рік тому

      @@ClarkReliance thanks Sir

  • @calebtebecktiku6889
    @calebtebecktiku6889 2 роки тому

    When blowing down of steam is done after 20sec and the drain valve is closed. Upon opening the the water valve to read the level in the boiler, will the water overcome the steam pressure?

    • @ClarkReliance
      @ClarkReliance  2 роки тому +1

      No, the water level will promptly equalize with the level in the drum, because the steam piping ventilates back to the drum. The water level should stabilize very quickly, unless there is a blockage in the piping or the isolation valves are not fully opened.

  • @mabbackj
    @mabbackj 6 років тому +2

    Thank you

  • @Ratman_Bejo
    @Ratman_Bejo 4 роки тому

    Very nice level glasses

  • @danq.5140
    @danq.5140 5 років тому +1

    Many operators in some plants never blow down level indicator piping on the dearaetor and condensate tanks.

    • @SeaMarinerosVlog
      @SeaMarinerosVlog 3 роки тому

      Any idea bruh..why some of them did not blow down the lvl.indic..

    • @danq.5140
      @danq.5140 3 роки тому

      @@SeaMarinerosVlog They may be worried about tripping the feed water pumps as most they are connected to a low water switch.

    • @RakeshPathak-lu8yc
      @RakeshPathak-lu8yc Рік тому

      Neat and clean in simple words explanation thanks

    • @Nek950515
      @Nek950515 Рік тому

      he forgets to mention any bypass button well doing it so you do not trip. we do a daily pm for insurance purposes @@danq.5140

  • @chanduch3708
    @chanduch3708 3 роки тому +2

    Thank you so much for valuable information

  • @hedayatazargoon41
    @hedayatazargoon41 Рік тому

    Perfect

  • @aohong4579
    @aohong4579 5 років тому +1

    Thanks a lot.

  • @rameshwarbade6204
    @rameshwarbade6204 6 років тому +2

    Very nice sir

  • @dilshanvimukthi4761
    @dilshanvimukthi4761 5 років тому +1

    very use full thanks a lot

  • @odeaneselectric
    @odeaneselectric 4 роки тому +1

    Now I know how to properly blowdown the sight glass

    • @shawnisrael3444
      @shawnisrael3444 3 роки тому

      you all prolly dont care but does anybody know of a way to get back into an instagram account..?
      I somehow lost the account password. I love any help you can give me!

    • @skylarkendrick656
      @skylarkendrick656 3 роки тому

      @Shawn Israel instablaster ;)

    • @shawnisrael3444
      @shawnisrael3444 3 роки тому

      @Skylar Kendrick Thanks so much for your reply. I got to the site through google and I'm trying it out now.
      Seems to take quite some time so I will get back to you later when my account password hopefully is recovered.

    • @shawnisrael3444
      @shawnisrael3444 3 роки тому

      @Skylar Kendrick it did the trick and I now got access to my account again. I'm so happy:D
      Thanks so much you saved my account :D

    • @skylarkendrick656
      @skylarkendrick656 3 роки тому

      @Shawn Israel Happy to help xD

  • @mercantiletechnical9169
    @mercantiletechnical9169 4 роки тому

    Need vedoi for steam turbine reduction gear element...

  • @rajeshhunter1399
    @rajeshhunter1399 2 роки тому

    Excelent....water tiub

  • @salmasayed1518
    @salmasayed1518 2 роки тому

    good and excelent

  • @Faz527
    @Faz527 5 років тому

    nice lecture

  • @fraserfernandes3197
    @fraserfernandes3197 3 роки тому

    Some makers recommend cross blowing

  • @mahmudulhasan4066
    @mahmudulhasan4066 5 місяців тому

    ❤nic job

  • @mercantiletechnical9169
    @mercantiletechnical9169 4 роки тому

    Tq

  • @bhaskeryadavbhaskeryadav1595
    @bhaskeryadavbhaskeryadav1595 4 роки тому

    Tq sir

  • @pekerjasawitserabutan86
    @pekerjasawitserabutan86 3 роки тому

    Ok

  • @michaelpalazzolo3038
    @michaelpalazzolo3038 3 роки тому +1

    My plant blows down every shift, every day.

    • @ClarkReliance
      @ClarkReliance  3 роки тому

      Hello Michael, we would be happy to discuss your application and best practices for extending the life of your equipment. Can you provide your city, state, and email?

  • @aarone9000
    @aarone9000 11 місяців тому

    Why not make a heater for personal home owners that use induction tehcnology to heat the water?! Then the jome! This is a multi million $ idea!

    • @250a-d8k
      @250a-d8k 10 місяців тому +1

      Electric heating, inductive and resistive, is more energy efficient than natural gas and is used in water heaters and furnaces in a lot of places. However natural gas is cheaper per kWh and so it is still the most common energy source for heating because of that.

  • @teodorosantanacamarena3427
    @teodorosantanacamarena3427 9 місяців тому

    Traducir

  • @lowkey5854
    @lowkey5854 2 роки тому

    What are the odds these days of actually blowing a boiler up?

  • @rajeshhunter1399
    @rajeshhunter1399 2 роки тому

    Sight glasses