Kwikee Step Repair

Поділитися
Вставка
  • Опубліковано 19 жов 2024

КОМЕНТАРІ • 14

  • @jaime9143
    @jaime9143 Рік тому +1

    You answered my main obstacle to replacing my step controller. How to get the steps to extend when they fail to function when the door opens. My steps were working intermittently. I had replaced the motor and gearbox 2 years ago, so they should be good. All the Lippert and Etrailer videos had the steps already out or loose. Your partial install to open the steps and verify the new controller works solved my issue. Thank you Sir.

  • @drifter19444
    @drifter19444 Рік тому +2

    Thanks for this video, best one I've found showing how to test the control unit and door switch. I will get back to you on my progress. Thanks again!

    • @firstsgtpete8614
      @firstsgtpete8614 Рік тому +1

      I must have hit something on the road that tore the wires for the steps out. I have 4 wires not connected to anything and can not seem to find a diagram showing how these wires connect.

  • @lurk1122
    @lurk1122 Рік тому

    Excellent video It helped me get my steps working I had a loose 4 wire connection

  • @stephenwalker5712
    @stephenwalker5712 Рік тому

    Great video. Perfect clarity on how to test and how it all works. Just fixed my step.😊

  • @JandBee
    @JandBee Рік тому

    Great video, thank you for the insite!

  • @kbrown4ou
    @kbrown4ou Рік тому

    If your steps are stuck make sure your RV is level.
    Our motor home didn’t look too out of level to me when our steps got stuck closed. My wife insisted we just needed to level the RV as the steps were likely bound up. Once again, she was right.

  • @nathanpitmon9214
    @nathanpitmon9214 Рік тому

    Awesome! Thank you

  • @hectormhernandez8073
    @hectormhernandez8073 7 місяців тому

    Hi, great video. Where did you order the control module?

  • @frankmedeiros4453
    @frankmedeiros4453 Місяць тому

    I am confused about something, how can you test the connections at the 4 pin connector when the connector is unplugged? Where is the power coming from?

    • @michielmeijer5653
      @michielmeijer5653 Місяць тому

      He tests at the plug side, the socket side is attached to the module. The plug side is getting ignition+, 12v from red wire, ground or float from brown wire which is the door sensor and float or 12v from white wire which is the switch.

  • @frankmedeiros4453
    @frankmedeiros4453 Місяць тому

    Ok, thanks, that was not to clear in the video.

  • @WinnieCoyle-j3q
    @WinnieCoyle-j3q 9 місяців тому

    My electric step will not remain retracted in off position. What could be the problem?

    • @timhei7584
      @timhei7584 9 місяців тому

      Make sure you have a good ground connection. Also check your on/off switch to be sure it is functioning properly.