Load Cell Sensor | Weighing Techniques (in Hindi)

Поділитися
Вставка
  • Опубліковано 8 вер 2024
  • Load cell sensor, in static and dynamic weighing systems, is the only transducer in which quality, quantity, legal compliance, and GST are linked to a product in any industry. This video describes the type of loadcell and weighing techniques used in weighing machines and weighing scales and weighbridge @dineshdiwani
    The video describes the working, measuring principle, and 4 wire, 6-wire type difference. Also describes precautions and selection techniques of static and dynamic measurement carried out in an industrial environment and How an intelligent load cell replaces older generation load cell to give high-level resolution in weighing measurements and improve accuracy level to the best.
    references:
    www.flintec.co....
    www.iqsdirecto...
    #loadcell #weighingscales #weighbridge #weighingsystem

КОМЕНТАРІ • 48

  • @satishkumarkashyap8028
    @satishkumarkashyap8028 8 днів тому +1

    एक्सपीरियंसड सर 👌

  • @talibhusainsaqlaini4396
    @talibhusainsaqlaini4396 2 місяці тому +1

    Very nice explained

  • @SaritaDevi-hn3wo
    @SaritaDevi-hn3wo Місяць тому +1

    Excellent sir

    • @dineshdiwani
      @dineshdiwani  Місяць тому

      @@SaritaDevi-hn3wo thank you, do share among your colleagues and friends

  • @ssm9419
    @ssm9419 Місяць тому +1

    Dear Sir your explanation is purely professional way but please, if it is in English, it will reach all over India

    • @dineshdiwani
      @dineshdiwani  Місяць тому

      @@ssm9419 I make videos in Hindi and English plus all subtitles available for most spoken languages. Please browse my channel for english videos

  • @SantoshSingh-nm1pe
    @SantoshSingh-nm1pe 2 роки тому +2

    Thank u Sir for lots of useful information on load cells...
    Request also delebrate on...
    1. Different Primary transducers for different applications of loads..like prooving ring, flexture and springs and how to choose.
    2. Applications for torque measuring.
    Rgds

  • @Manalomata_balu
    @Manalomata_balu 7 місяців тому +1

    Excellent explanation...thanks

  • @nadimmulla7379
    @nadimmulla7379 2 роки тому +1

    Good work sir 👍.

  • @kumarayush1923
    @kumarayush1923 Рік тому +1

    Excellent explanation

  • @sanathkumar2562
    @sanathkumar2562 Рік тому +1

    Good explanation

  • @bhagwansinghlodha939
    @bhagwansinghlodha939 Рік тому +1

    very nice sir

  • @imranhayat198
    @imranhayat198 15 днів тому +1

    Degital analog difrans me noladge batavo

  • @mrvadher6464
    @mrvadher6464 Рік тому +1

    Very nice Boss

  • @sonu_utube
    @sonu_utube 2 роки тому

    Sir, Heads off to your knowledge...

  • @sajankhan5966
    @sajankhan5966 Рік тому +1

    Nice

  • @SantoshYadav-fw5ni
    @SantoshYadav-fw5ni 6 місяців тому

    Nice explanation

  • @Pankajkumar-ec6kl
    @Pankajkumar-ec6kl 11 місяців тому

    Load cell wiring or display settings or kya lodcell alag alag voltage ka hota hai kya iska video chahiye

  • @bbarot124
    @bbarot124 2 місяці тому +1

    Sir please tell me how to check whether lorry weighbridge is manipulated or not.

    • @dineshdiwani
      @dineshdiwani  2 місяці тому

      @@bbarot124 keep a vehicle in your control whose weight you know, for example you car or tractor or any other vehicle under your control. And keep weighing that vehicle frequently I.e. daily, weekly monthly. This way you basically checking it's calibration against standard weight. Any deviation may indicate some kind of manipulation.

  • @srijansingh9834
    @srijansingh9834 11 місяців тому +1

    Sir please make video on Schneider weigh feeder & bin calibration . process

  • @funnyboy4917
    @funnyboy4917 8 місяців тому +1

    Sir,
    Can we able to take weight of bin/ bunker when it's two load cell are faulty...if we can use so please reply need to change load cell location or 120degree apart from each other

    • @dineshdiwani
      @dineshdiwani  8 місяців тому

      Sure it will work with single load cell... If material is homogeneous around the peripheral if bunker. But if material is accumulated on one side then it will not give correct reading. Thats why 3 load cells are placed for rounded bunker to get average reading of 3 load cells.

  • @sachinrokade7502
    @sachinrokade7502 4 місяці тому +1

    Sir if my hoper bearing capacity to measure the material is 1000kg and I want to attach 4 load cell tell me load cell details

    • @dineshdiwani
      @dineshdiwani  4 місяці тому

      If it is rounded hopper 3 loadcells would be perfect. If it is squared hopper then you need to have 4 loadcells. Capacity always taken maximum load exerted on load cell here 1000 kg material capacity + empty hopper weight suppose it is 1500 kg. Now my load is 2500. Now add factor of safety 1.5 or 2 times of Max load, seeing the criticality and then calculate load cell capacity.

  • @user-im3kx6yn6i
    @user-im3kx6yn6i 8 місяців тому +2

    sir,can i use this sensor to measure weight of backpack?please reply.

    • @dineshdiwani
      @dineshdiwani  8 місяців тому

      It is the only sensor which is used in every weighing machine.

    • @user-im3kx6yn6i
      @user-im3kx6yn6i 8 місяців тому

      @@dineshdiwani Sir, I want to connect load cell sensor with Arduino and it should give me weight of backpack as output example:10kg, etc

    • @dineshdiwani
      @dineshdiwani  8 місяців тому

      @@user-im3kx6yn6i load cell needs excitation voltage and gives milli volt output upon exerting some force over it. Output millivolts can be fed to any system which can convert into in physical readable form

  • @shivnathbhosale380
    @shivnathbhosale380 2 місяці тому +1

    Load cell ya controller me Pani gaya to kya problem Aati hae

    • @dineshdiwani
      @dineshdiwani  2 місяці тому

      Pahle to pani jayega nhi kyonki load hermatically sealed hota hai.... Agar gya to dc supply short ho jayega load cell controller ki .. load me pani se damage hona ka kuch nhi hota

  • @ambikeshgiri2284
    @ambikeshgiri2284 Рік тому +1

    Sir rtd aur thermocouple ka dip video banaye

  • @nileshgurjar8383
    @nileshgurjar8383 9 місяців тому +1

    How can I identify if a single loadcell is malfunctioning in between on a 8 loadcell weigh bridge..?

    • @dineshdiwani
      @dineshdiwani  9 місяців тому

      You need to check output of each load cell. If it is faulty or load not getting transfer on that load cell, you won't see much change in millivolts in different load condition.
      Second, you may isolate one load cell at a time and see which load cell causing the average millivolts to be increased as you isolates it's all wires from load cell JB. Faulty load cell brings down the average voltage of all connected load cells.

  • @shivprasad8446
    @shivprasad8446 Рік тому +1

    Sir good evening
    My question is why we connect loadcell 120 degree in case of 3 load cell combination

    • @dineshdiwani
      @dineshdiwani  Рік тому

      Fir circular hopper or bin.. minimum loadcell requirements is 3 when all the weight of bin or hopper is transferred. You can use more 3 loadcell but why when 3 loadcells are sufficient to take the weight of bin or hopper. So better to place these 3 loadcell at equivedistance which comes out to be 120 degree.

    • @funnyboy4917
      @funnyboy4917 8 місяців тому

      Sir can we use 1 load cell for some time when 2 load cell are faulty

    • @funnyboy4917
      @funnyboy4917 8 місяців тому

      Sir,
      how solid flow feeder/ meter showing TPH...
      Load can be measured by load cell by impact plat....but how time cames....it doesn't have any techo/ moving equipment.....

  • @rajkishorepradhan463
    @rajkishorepradhan463 11 місяців тому +1

    What is the common resistance value of load cell ?

    • @dineshdiwani
      @dineshdiwani  11 місяців тому

      Depends upon its design and specifications and varies from 120, 350 to 1000 ohm in some cases

    • @rajkishorepradhan463
      @rajkishorepradhan463 11 місяців тому +1

      @@dineshdiwani is it individual resistance connected value or all four connected resistance value in strain gauge .

    • @dineshdiwani
      @dineshdiwani  11 місяців тому

      @@rajkishorepradhan463 individual branch of bridge ofcourse

    • @rajkishorepradhan463
      @rajkishorepradhan463 11 місяців тому +1

      @@dineshdiwani ok thanks...

  • @subratpatri927
    @subratpatri927 6 місяців тому +1

    Excellent sir