КОМЕНТАРІ •

  • @Somali_top
    @Somali_top 11 місяців тому +6

    I almost returned, Starts within 20 sec. shut-off after seeing your videos I did the same thing Paypass and it works no more shutting off. They need to update that sensor for the Carbon monoxide. Thank you.

  • @psyclepath1964
    @psyclepath1964 9 місяців тому +2

    This is the best video I've seen on the subject. Thorough job, including the miserable torx screws.
    Cheers, and have a great weekend!

  • @the_vipernator8960
    @the_vipernator8960 5 місяців тому +2

    Saved my ass, was going crazy until I saw the light flashing. Really appreciate 👍

  • @smelterx
    @smelterx 5 місяців тому +5

    Just did this sensor bypass. Worked perfectly.
    Couple of adjustments -
    No need for the special T-25 bit tool. Just simply remove the two 8mm hex bolts that holds the bracket in place. The sensor is attached to the bracket.
    The two unused wires - Gray & Brown can be covered with heat shrink tubing and pinched closed on the ends.
    Besides the access cover having to come off. The Red side panel frame must be pulled off as well. Remove the 6 allen head bolts on the side frame and the 2 allen bolts on the front to allow it to come off.
    The front panel is held in place by 6 philip screws. The Propane/Gas selector knob has a deep philip screw that must be removed to pull the front panel.
    I soldered the wires together for a more durable connection.

  • @chrisb8744
    @chrisb8744 3 місяці тому +1

    Bro. You came thru in the clutch with this. I run a food truck and you can't imagine how embarrassing the cutoff was

  • @harborfreight
    @harborfreight 3 дні тому

    The CO shutoff system is a critical safety feature which can help to prevent the risk of sudden illness and death resulting from the accumulation of undetected CO, which is an odorless, colorless gas impossible for the human senses to detect. The health and safety of our customers remains our top priority and we recommend discontinuing any use of this product without a functioning CO shutoff system.

    • @mikebolton3816
      @mikebolton3816 3 дні тому

      @@harborfreight
      Nice lawyers speak 🙄
      As I mentioned... This is for an install on a work truck, in a confined box. The unit is on rails, to be pulled in and out of storage. The CO sensor wouldn't allow it to be run, because the exhaust was being deflected from the storage box, back out, directly into the sensor. It ran for maybe 30 seconds.
      I installed a 6" fan, at the base of the storage box, to evacuate any accumulated gases.
      The "CO SENSOR" with no disable, assumes everyone's a moron.
      I made it clear, this is for a unique circumstance.
      What the unit needs, is a resetting switch, to disable the CO sensor.

  • @key572
    @key572 5 місяців тому +1

    Nice job Mike! I've been waiting a week for you to make this video... 🙂

  • @mancavechronicles2139
    @mancavechronicles2139 10 місяців тому +1

    I just did mine, works great. Thanks for the info.

  • @King-sn5dt
    @King-sn5dt 4 місяці тому

    Awesome. I got fix my issue. And I need to find the heat out from my wood generator box.

    • @mikebolton3816
      @mikebolton3816 4 місяці тому +1

      I used a 6" through wall fan that's 120v and plug it right into the generator. I have it sending the air down and out of my box.

  • @jeffholsinger3356
    @jeffholsinger3356 10 місяців тому +3

    Can you make the wiring more clear not sure what the gray and brown loops are doing.

  • @jeffholsinger3356
    @jeffholsinger3356 10 місяців тому +3

    I use HVAC aluminum tape to cover the holes in the sensor on this gen, and also the 1400 watt works without all the wire mods. You must use the aluminum HVAC tape........On the 5000 watt all you have to do is remove the two 8mm bolts and cover the hole in the sensor. mind doesnt shut down any more for CO. 8 min. mod

    • @mikebolton3816
      @mikebolton3816 10 місяців тому

      Interesting. I wonder if something in the adhesive, on the tape I used, made it angry?

    • @jeffholsinger3356
      @jeffholsinger3356 10 місяців тому +2

      @@mikebolton3816 Doing a full bypass is the best way to be sure...

  • @mancavechronicles2139
    @mancavechronicles2139 10 місяців тому +1

    The remote start still works with this modification

  • @joncrawford5687
    @joncrawford5687 4 місяці тому

    Does this modification void the warranty?

  • @user-fi7ih1xf1i
    @user-fi7ih1xf1i 9 місяців тому +2

    Is it possible to put a switch in it to turn it on and off

  • @pioneercuts3362
    @pioneercuts3362 9 місяців тому

    I need a bit more advice. I've wired the four pin to the two pin. I see the remaining two wires are looped back to the four pin connector. Is there more i should know about this? Should the four pin remain disconnected from the generator? I've tried several combinations to no avail. Any ideas on what im missing?

    • @revolverguy
      @revolverguy 7 місяців тому

      The two wire he looped are just terminated. And yes, plug the 4 pin back in.

  • @Tommy-ss2bz
    @Tommy-ss2bz 3 місяці тому

    Just did the bypass. Still runs 30sec and shuts off??? Any other thing to do?

  • @kaminsr
    @kaminsr 24 дні тому

    anyone know how to bypass the CO detector on a Ryobi 6500?

  • @jeffholsinger3356
    @jeffholsinger3356 8 місяців тому

    Can you tell us what the brown and gray loops are doing?

    • @mikebolton3816
      @mikebolton3816 8 місяців тому

      They are just dead heads, I looped them back, just in case I have to reinstall the sensor if I have to warranty the generator.

    • @jeffholsinger3356
      @jeffholsinger3356 8 місяців тому

      thanks ....@@mikebolton3816

  • @alek8881
    @alek8881 24 дні тому +1

    i by pass still shots off

  • @WilliamSettle-bv5gl
    @WilliamSettle-bv5gl 10 днів тому +1

    Does the remote start still work with this mod?

  • @sailingcattales
    @sailingcattales 11 місяців тому

    I wonder what would happen if you just put a piece of tape over the carbon monoxide sensor if that would accomplish the same thing without cutting and re wiring?
    If the tape fails, I'll try this 😉💪

    • @mikebolton3816
      @mikebolton3816 11 місяців тому +1

      It wont run. I tried that, and it ran for a few seconds and died.

    • @sailingcattales
      @sailingcattales 10 місяців тому

      @@mikebolton3816 It must test for oxygen as well as CO2, if it doesn't see oxygen it shuts down. Just guessing
      I tried stuffing a asbestos type material in front of the sensor without taking the Allen screws out and pulling off the side. Nope.. didn't work. Looks like I'll have to try to duplicate your method. I wish your video was more detailed. Where did you get the connector, exactly which wires to rewire, close up. Like that. Your video is the only video for a 5000. Thanks for you help, it's very appreciated 👍

    • @sailingcattales
      @sailingcattales 10 місяців тому

      ​@@mikebolton3816I found this video, it's not the same generator but illustrates what I was thinking.
      Thanks again
      ua-cam.com/video/fiwYnalqgCA/v-deo.html

    • @sailingcattales
      @sailingcattales 10 місяців тому

      ​@@mikebolton3816Hey Mike, the tape over the censor worked like a champ 🏆 not one CO2 shit off so far 😉
      Thanks Mike Loved your video

    • @sailingcattales
      @sailingcattales 10 місяців тому

      ​@@mikebolton3816Mike I have an update. The CO2 censor did shut the machine down once. so.. taping over the censor has not solved the problem 100%, but I would have to say it has vastly improved. 👍😉 I'll update as time moves on. The Censor is completely covered, how 😳 can it still detect CO2? 😮 It did once, so far

  • @seancwa
    @seancwa 11 місяців тому

    Not even gonna give credit to where you stole the info?

    • @mikebolton3816
      @mikebolton3816 11 місяців тому +3

      Well, I looked around, and found a written post. Most everything I found was for the 3500. Dont remember name. Dont care either. Stole? Your kidding right? Im not making a single penny. Its a fyi. Ive put up a whole 3 videos in like 10 years.

    • @sailingcattales
      @sailingcattales 10 місяців тому +6

      Where's this stolen info? I've found no one but the man Mike, who's made a video about bypassing a predator 5000 co2 censor.
      Post some link to this stolen information please 👍