  • I always said I won't install an active balancer on my battery, so this is just a test, right?! It's a test! 😊This morning, the battery was at 12%SoC and very out of balance and I was wondering what would happen if we install the active balancer from Hankzor. Can it balance out these high capacity cells and save the battery from been disconnected by the BMS?
    It's a test, right?
    Hankzor active balancer:
    off-grid-garag...
    Please subscribe and join me on my journey of the Off-Grid Garage!
    For more information, please check out my website with links to all the batteries, materials, devices and products I have used in my videos: off-grid-garag...
    The 'buy me a beer 🍻' link is here (on the website, scroll all the way down):
    off-grid-garag... Thank you for your support!
    **** These are the batteries you are looking for ****
    🔋➡EVE LF280 LiFePO4 cells 3.2V/280Ah: off-grid-garag...
    🌞➡Solar, Controllers, Inverters and accessories: off-grid-garag...
    🔧➡Tools, Analysers and Testers: off-grid-garag...
    📈➡ Battery Tests and Results: off-grid-garag...
    🔌➡Batteries, charger and accessories: off-grid-garag...
    ⚡➡Cables, Inverters and Electronics: off-grid-garag...
    Get 5% off when buying Bluetti all-in-one Power Storage Products!
    off-grid-garag...
    New to AliExpress? Use my referral code below to register and earn US$19 store credit. What a great start! a.aliexpress.c...
    Take a live sneak peak at the Off-Grid-Garage in the Victron VRM World:
    vrm.victronene...
    My Tesla referral code (free 1500 SuperCharger km / 1000mi for you and me)
    ts.la/stefan96963

КОМЕНТАРІ • 458

  • @justdoityourself7134
    @justdoityourself7134 3 роки тому +19

    I bought an active balancer and never looked back. I'm disappointed with anyone that ever told me not to get one.

    • @darrenbenson2606
      @darrenbenson2606 3 роки тому +3

      I agree. The best thing I’ve done for my battery bank.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      Got it connected for a week now and it's been great so far.

    • @kevinmills5293
      @kevinmills5293 3 роки тому +2

      That active balancer seems to be doing a great job. Have you estimated the extra Ah’s you get before the inverter/BMS cuts out?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      @@kevinmills5293 that's not much. I would expect this to be far less than 5Ah, maybe 2-3Ah only in total.

    • @tonypower5625
      @tonypower5625 3 роки тому

      Question...let say that I want to disconnect the active balancer...should I start by the small connector...and then follow with the large one? ...I'm talking of an active balancer 16 s....the connector with the ground has 10 pins...and the other connector has about 8 pins and no ground. Thanks

  • @guy7gsa
    @guy7gsa 3 роки тому +34

    We have completed our mission and convertered the Anti-Balancer. 😂😂😂

    • @bentleyjarrard885
      @bentleyjarrard885 3 роки тому +6

      M P, Ya, I did my part and suggested an active balancer several times on this and other channels.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +7

      Hahahaha, yeah im' really impressed so far. I'm going to wait until the battery is full though to see if it can hold up the positive start.

    • @guy7gsa
      @guy7gsa 3 роки тому +2

      Can the active balancer setting be changed on the bms/active balancer hybrid interesting. So you could choose to have them balance on top or bottom only.

    • @bentleyjarrard885
      @bentleyjarrard885 3 роки тому +2

      @@guy7gsa Unfortunately the Bluetooth balancer does not have Top or Bottom balance settings. The user can set the balance current from 0.2A up to the max which is 1, 2, 5, or 10A depending on the model as well as the Delta trigger voltage between cells from 0.001V to about 0.500V (1mv to 500mv). Cell balancing can also be turned off completely and the unit will only display cell voltages and internal resistance values.

    • @SkypowerwithKarl
      @SkypowerwithKarl 3 роки тому

      Yeah I’m part of the pestering people too.📣

  • @camro210
    @camro210 3 роки тому +44

    In theory, it actually makes sense that the pack voltage increased after active balancing (in your specific situation) because for a given amount of amperage transferred, the higher voltage cell would see a *smaller* voltage decrease compared to the voltage increase that the lower voltage cell would see. This is due to where each of those cells lie on the voltage curve, of course.
    In reality, that would obviously depend on how efficient the balancer is.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +4

      As others said here in the comments. I missed that... absolutely correct

    • @diyEVguy
      @diyEVguy 3 роки тому +1

      Well said!

    • @mwint1982
      @mwint1982 3 роки тому +1

      Its prob just rounding

    • @mysterytechknowledge3664
      @mysterytechknowledge3664 3 роки тому +2

      @@OffGridGarageAustralia BTW...When you were connecting the balancer, I think the diagram you were looking at was from the back side showing the mosfets not the capacitors.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      @@mysterytechknowledge3664 that would make sense then. I'll check it again.

  • @saidt.8200
    @saidt.8200 3 роки тому +9

    I’ve assembled a 4 cells battery with BMS only and I had a troublesome cell, it charges faster than the other 3 so the pack never could charge beyond 3.35v each cell. Until I added a 5A HELTECH active balancer and I was so happy to charge the cells to 3.65v each. Definitely the active balancer made a big difference in my case. It balances the cells at all times while the BMS balances the cells only when charging (not sure about when discharging) and with a small 200mv dissipation from the overcharged battery. The active balancer does not dissipate the over amps, it rather transfer the amps to the other cells with lower charge.

    • @Jasonoid
      @Jasonoid 3 роки тому +1

      I had the same issue, love my active balancer 😁

  • @upnorthandpersonal
    @upnorthandpersonal 3 роки тому +18

    Overall voltage goes up because cell voltage is not a linear curve. Taking power from one cell to put into another does not mean you take x voltage from one cell and put it in another; in this part of the curve you get a big delta V with small changes in state of charge.

    • @BradCagle
      @BradCagle 3 роки тому +4

      Beat me to it. this is 100% correct

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +6

      That is correct, I didn't think about that. Thanks!

    • @upnorthandpersonal
      @upnorthandpersonal 2 роки тому +1

      @@josepeixoto3384 Depends on where you are in the curve. In the case we were discussion, we were in the knee of the curve where it's very steep.

  • @megachief4ever
    @megachief4ever 3 роки тому +3

    Nice! I'm in the process of building my battery pack 8s with this active balancer and a Dali BMS... perfect timing! Thank you! Now I need the strength/guts to make a video of my setup (hurricane disaster vanbuild)... much easier said than done. You are my hero! (Smartshunt before BMS ... got it)

  • @bigbeef2654
    @bigbeef2654 3 роки тому +9

    I would love to see you add a second balancer, the same one you have to see if it balances twice as fast. The balancer on your BMS does not use enough balance current to keep up with your massive bank.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +6

      Now after several days, all cells are still in balance. Once this has been achieved, I think the max 5A balance current is fine. As the balancer works 24/7 it does not need to be as fast. As seen in the video, it takes only 12h or so to get them all in line again.

    • @rOSScOGITANS
      @rOSScOGITANS 2 роки тому +1

      yes many users suggest it, i think it's important when you have not good quality cells

  • @marcusschmidt2363
    @marcusschmidt2363 3 роки тому +4

    Ok seeming how this a test i want to throw in the mix this question. Seeing what the balancer has done in 24 hours ( approximately ) ... can you have 2 balancers in parallel ? Would they fight or work together? Thanks again for your time!
    Marc.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Why would you do this? Just for the sake of testing or to balance faster? I have read some comments here that people have done that and it seems to work.
      Might be worth a test 🤔

    • @marcusschmidt2363
      @marcusschmidt2363 3 роки тому

      Thanks for your time... using two balancers at the same time is yes a curiosity question but more for a point of the balancer works well only at the ends of the charge curve with any noticeable improvement and not in the middle of the flat section.... so the time spent at the ends is an extremely short window of opportunity.... unless I have misunderstood a balancers functions? Thanks for doing what you do andy!
      Marc

    • @showmequick2245
      @showmequick2245 3 роки тому

      I up vote this. Seriously this could be game changer for lots of people with mismatched cells. Please do this

    • @mhamma6560
      @mhamma6560 3 роки тому

      Won't gain anything long run. Will it get the first day's balance done quicker, of course. Does it make any sense to leave it on there when 1 is plenty? No

  • @lifeunchainedtruckandrv2166
    @lifeunchainedtruckandrv2166 3 роки тому +3

    Also...Love your off the beaten path theories and practical testing to find the real results. It helps us to understand and build off your experiences!

  • @rickcooperjr62864
    @rickcooperjr62864 3 роки тому +3

    Glad you see the light a active cell balancer removes a ton of headache / hassle as I suggested several times its the way to go for simplicity and theyre power draw is almost a mute point the thing is it protects your cells from imbalance of cells dipping to low while others are in the good this can and will prolong the lifespan and use ability of your lithium cells its a win win for literally pennies compared to the rest of the hardware and such so where is the negative there is only positive in installing / using a active cell balancer.

  • @trevilights
    @trevilights 3 роки тому +3

    I bought one active 24v 8S balancer a couple of weeks back because I had a couple of cells that will just outrun other cells when charging and will get very close to the overcharged level. The Smart BMS was never capable of balance them right. The active balancer solved this problem. I have it connected ALL the time now. It has performed amazingly.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Yeah, it looks like these things actually work quite well.

    • @trevilights
      @trevilights 3 роки тому

      @@OffGridGarageAustralia Yes. In my case, I am using the inverter to power all of my essential loads in my home. The battery is cycle once a day and I need the cells to be as balanced as possible in a short period of time. This device help a lot. Specially when it is capable of moving 5A.

    • @SenatorPerry
      @SenatorPerry 3 роки тому

      Just to add, you can get two of the active balancers and put them in parallel on the same balancing leads. They collide a lot at first, but over time they sync up with what they are doing.

    • @trevilights
      @trevilights 3 роки тому

      @@SenatorPerry Good to know. Thx.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      @@SenatorPerry Cannot imagine how this may work, but I will test it... 😉

  • @57beanyboy
    @57beanyboy 3 роки тому +3

    I'm convinced. Two active balancers have been ordered!

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      I'm still testing....
      For two different batteries or just to double them up?

  • @ricolauersdorf687
    @ricolauersdorf687 11 місяців тому +1

    In a low current (solar, not vehicle) situation, i always suggest inductor balancers instead of capacitor ones. The reason is, that you always need to convert energy between magnetic and electric fields, to achieve low losses. But of course a capacititor model does the job and delivers current. Most of the time we store energy in a static voltage field, what means that a low loss energy transciever needs an inductor and a switch. Its a smps then. If we would use a rotation storage, inductive coupled to an also alternating voltage, then an good energy transformer would make use of capacitive energy delivery. Imho we all would throw away much less lithium batteries, if there would be active balancers in them and not only balancers which start to balance, when a cell is already in a harm region. Had a fresh battery for my scooter, which was weak aftr only 2 years. I opened the thing and the 24s lifepo was absolutely out of balance. I figured out, the top balance was not sufficient to hold the chargers amps. After adding an active balancer, i got it back to work since half a year. You do a great job there!

  • @trevortrevortsr2
    @trevortrevortsr2 3 роки тому +12

    The bottom "Knee" curve is not linear - the lower the voltage the less energy is needed to proportionally impact the voltage overall voltage increased because your moving energy from a fatter part of the curve where substantial energy is needed to impact on voltage to the thinner more sensitive zone- you are bottom balancing your cells which is probably better for your pack as you have capped the upper voltage at 3.45v preventing it climbing the upper knee much to effectively upper balance accurately

  • @geoffreylohff3876
    @geoffreylohff3876 3 роки тому +2

    Andy - love your work!
    And your choice for sound effects crimping those balancer leads!

  • @ltcmdrdata4611
    @ltcmdrdata4611 3 роки тому +3

    thats what i´m talking about. active balancer´s are working very well in combination with a bms. bms for battery/cell protection and active balancer to balance, up to 6.5A.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      That seems to be working well.
      Are you the real Ingo von der Lippe? 🤔

    • @ltcmdrdata4611
      @ltcmdrdata4611 3 роки тому +1

      @@OffGridGarageAustralia Yes, I´am the real one. The name of the other guy is Jürgen von der Lippe but his real name is Hans-Jürgen Hubert Dohrenkamp.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      @@ltcmdrdata4611 Das hab ich jetzt verwechselt!

  • @r.b.l.5841
    @r.b.l.5841 Рік тому +1

    I use BMS with active 2A balancer - after nearly a year, checked three 280Ah batteries, they are 3-4milli-volt spread in each battery!
    Thanks Andy, I agree with you, the balancing is a low cost and important piece of equipment to keep all the cells operating at peak performance, no runners.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  Рік тому

      Yeah, I like them very mich as well. Do you leave yours on all the time?

    • @r.b.l.5841
      @r.b.l.5841 Рік тому

      @@OffGridGarageAustralia YUP! I see no reason to turn them off, and the cells are always very well balanced - cost is nothing, benefits are great!

  • @davidjimenez8952
    @davidjimenez8952 3 роки тому +4

    how much quality having your videos!!! better than Galaxy Wars films. thank you, i enjoy a lot with this content.

  • @PausM1142
    @PausM1142 3 роки тому +3

    In my first test I charged the cells to 3.45V with a cell difference of greater than 100mV. The DALY BMS switched off charging at 3.5V for the highest cell and the internal balancer apparently had no effect. Then I connected the active balancer and you could watch the voltage difference decrease. It took less than 12 hours for the cells to balance at 3.45V with a voltage difference of 1mV. I was just as amazed as you.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Same experience here, the BMS's balancer just does nothing with these high capacity cells. Now, everything seems to be in balance no matter what I do.

  • @rcinfla9017
    @rcinfla9017 3 роки тому +2

    I am an advocate of active balancers. Cheap ones can have issue with proper balancing direction when real world inverter and charger currents causes cell voltages to jump around confusing the balancer. Evaluating performance with no inverter or charging current variance is not real world use case.
    Be warned about capacitor charge pump type balancers long term reliabilility with electrolytic caps being subjected to high ripple current. Usually the cap's electrolyte dries out and capacitance declines. Sometimes they burst and short out from the high ripple current. As they are directly connected to cells (through MOSFET switches) there is no safeguard if they short out. If top of caps start to bulge out it is a warning of failures to come.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      I know about the problems with capacitors from my electronic background. I think they have used the better quality ones which are fully sealed and don't dry up any more as other types do.

  • @marcelprivat
    @marcelprivat 3 роки тому +1

    Du hast YT verstanden. Du bietest informatives und Unterhaltung in einem. Es macht Spaß Deine Videos zu sehen. Vielen Dank. Und mach weiter so. 🤗

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Vielen herzlichen Dank fuer dein nettes Feedback. Dann will ich mal wieder ran, es gibt noch so viel zu entdecken und zu zeigen 🤳

  • @AHMADKAMALZUBER
    @AHMADKAMALZUBER 3 роки тому +1

    I am convinved with the balancer. Thanks Andy

  • @mhamma6560
    @mhamma6560 3 роки тому +3

    Great vid on using a balancer. It can help squeeze a little bit more out of a pack as it's getting low. A balancer really is cheap piece of mind, plus long-term it might just get more life out of a cell that might have failed sooner. That's a hard thing to test since each cell is unique, but I'd bet it really helps out in the long run. I think a long-term test like 6 months or so and then remove it and check for deviation after a week of no balancer to see if the pre-balancer deviation has returned. That should show if it's doing anything for life extension or not.

  • @bosshog2328
    @bosshog2328 2 роки тому

    Glad you finally came to your senses. If we live by old technology we'd still be fighting wars with piston aircraft.

  • @edwingroen2028
    @edwingroen2028 3 роки тому +1

    My active balancer is connected parallel to the Daly 200A smart BMS and it works fine since the start. Bms is burning high voltage off and wasted as heat. The active balancer is always on and will continue to balance between full and empty cells. I like it so much that I will do the same next time again. You get more amps in and out of same battery pack.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      Thanks for the info. I'm really pleased with the balancer now after several days. It works very well.

  • @MadMatty72
    @MadMatty72 2 роки тому

    So scientific in determining balancer wiring - you had a bunch of caps with negative stripe on them to help trace to the negative terminal.

  • @alexandergunda8916
    @alexandergunda8916 3 роки тому +3

    Andy I'm happy that we finally succeed in making you a "believer" 🤣
    Btw. the schematics of the balancer are OK - if you have a closer look they are taking the side with the ICs and not the one with the capacitors as their top side.

  • @gustersongusterson4120
    @gustersongusterson4120 3 роки тому +2

    Great video, looking forward to the top balancing video!

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Yeah, it will take a while until I reach that with the current sun. Also supplying parts of the house already with power so the battery won't charge much during the day.

  • @rendark419
    @rendark419 3 роки тому +1

    Hab ich doch gesagt. Aktiver Balancer arbeitet hier auch super! Und mal wieder ein schönes Video! Warte schon sehnsüchtig auf den Australien-Sommer!
    Kämpfen in unserer Region gerade mit einer Hochwasser Katastrophe.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Stay safe over there! Hoffentlich bist du nicht selbst betroffen.
      Ich kann schon etwas mehr Solar sehen, was reinkommt. Die Tage werden wieder etwas laenger und die Sonne steht steiler.

  • @bengtforsblom
    @bengtforsblom 3 роки тому +1

    Oh man, i just love the work you are doing !!!! It has helped me a lot here in Finland where i built a 12 v 100 A battery of China lifepo cells wich i use in my fishing boat and is connected to the trolling motor. When the cells came in June, 3 cells where in balance and 1 was 0,35v higher, i bottom balanced them for 2 days and then charged and installed in my with a BMS and everthing is working just fine :)

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      Thank you very much for your feedback. It is great to hear the these videos and information help others to better understand how the cells work, how to set up the battery and make it work for their specific need.

  • @alexmoro348
    @alexmoro348 5 місяців тому

    From my experience I say that it is better to add some fuses on that balance leads. Nice video !

  • @SuperBrainAK
    @SuperBrainAK 3 роки тому +2

    you have to remember that measuring the current on the balance wires is not a true reading, because with two cells are in series if one is charging and the other next to it is discharging you will get a net current because you are measuring both cells at the same time.

  • @mondotv4216
    @mondotv4216 Рік тому

    The active balancer is great at both ends of the curve. I would install a switch so I can turn it off once the battery is properly balanced. Then when it starts to drift again turn it back on. Better f you can program it but that adds cost.

  • @lifeunchainedtruckandrv2166
    @lifeunchainedtruckandrv2166 3 роки тому +3

    Wow Andy! Maybe active balancing is actually the way to go. If the cells can be that far apart with a standard BMS That would almost certainly mean premature degradation and variation to a few cells in the pack over long duration of having different states of charge and discharge.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +2

      Yes, I was quite shocked when I saw the BMS in the morning. The pack seemed to be very balanced at the top from my last videos but cell #6 would have cut off early and tripped the BMS at some stage. The active balancer seem to work very well now after a few days.

  • @lukasmauerhoff9330
    @lukasmauerhoff9330 3 роки тому +2

    I see a disadvantage especially in your case with a relay-bms and slightly missmatched cells. If you're battery is at a high state of charge and there is a high amperage outside, overvoltage disconnected will trigger because the balancer destroyed your top balance and will not be able to keep up with the sun. Because you have a relay-bms, there will bee no consistent power anymore until the sun is down and the balancer is finished. You maybe get that alternating on/off situation again...

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      I don't think this is going to happen. My max charge voltage is only 3.4V and then I let the battery absorb, so current will taper off. So far the 'balancer test' seems to work quite well but I have to wait what happens when I fully charge the battery again.

  • @stevedutcher3875
    @stevedutcher3875 3 роки тому +1

    I ordered two on the balances for testing, thanks!

  • @DanBurgaud
    @DanBurgaud 2 роки тому +1

    11:32 ABs does not transfer voltage; it transfers Electric Charge.
    Some of your cells had lowered charge capacity resulting in faster to drop when discharging and faster to rise when charging.

  • @AG8000
    @AG8000 3 роки тому +2

    Aktiv balancer is a must have nice Video. 👍👍👍

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Ha, some here say the opposite 😉

    • @AG8000
      @AG8000 3 роки тому +1

      @@OffGridGarageAustralia Glaub dehnen nicht, die Lügen 🤣🤣😉

  • @jamesbsa6450
    @jamesbsa6450 3 роки тому +2

    @off-grid-garage Andy, now for a test on overall capacity acheived w/o balancer (until BMS cutoff) Vs. W/cell balancer. In theory you should be able to get more energy out as the higher capacity cells should feed the weaker ones so they all hit cutoff at about same time.

  • @muddy11111
    @muddy11111 3 роки тому +1

    On your recommendation I got a QUCC BMS. However I got the mosfet one not the relay. On overcharge of a cell this simply turns off the charging, leaving the discharge and balancing functions still working.
    You also sold me on the balancer. That works OK, but to stop high cell voltage cut off I run the BMS balancer at 50mV below cut off voltage. This just keeps the balancer out of trouble. Cells are balanced nicely over most of the curve, but getting the top end balanced looks like taking several days. Heading in the right direction slowly.
    Keep up the good work....

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      I wasn't aware that they make smart BMS with fets and higher current (200A).

    • @muddy11111
      @muddy11111 3 роки тому

      @@OffGridGarageAustralia Ahh... mine is only 100A

    • @muddy11111
      @muddy11111 3 роки тому

      @@OffGridGarageAustralia Is you fuse not 100A ? so 200A BMS is nice but you could get away with a 120A one, and still get 5KVA at the inverter.
      On the balancer, have you considered using the other bolt on the busbar so you don't disturb the BMS connections ?

  • @igornedashkivskyi1472
    @igornedashkivskyi1472 Рік тому

    Дуже гарний і потрібний огляд.
    Дякую тобі, чоловіче!

  • @lucdesmedt7056
    @lucdesmedt7056 2 роки тому +1

    Andy, the total voltage of a battery pack can rise with an active balancer for the following reason.
    The voltage of a battery cell is non linear, especially when the battery is near empty or near full.
    Let us take an extreme example of a 2S battery pack.
    cell 1 : 2,5V
    cell 2 : 3,2V
    Total = 5,7V
    When the active balancer transfers capacity from cell 2 to cell 1, the voltage of cell 2 will decrease less then the increase of voltage of cell 1 due to the non linear behavior of a LiFePo4 battery cell.
    after some balancing time one could have following measurments
    cell 1 : 2,7V
    cell 2 : 3,1V
    Total : 5,8V
    I hope to have cleared out the origin of a voltage rise when balancing with an active balancer at low SOC or high SOC.
    Greetings,
    Luc from Belgium (near Austria an far away from Australia)

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  2 роки тому

      Thank you. Yeah, that makes sense. Hence it is important to always have a BMS as well which monitors single cell voltages and disconnects the charger/load if one cell gets out of scope.

  • @arebear4797
    @arebear4797 3 роки тому +1

    Hi Andy, Good day,
    Just want to say that I was expecting that you going to change you mind about the active balancer. It is lucky that you got the right one and not the small one which might have change the outcome and your conclusion of this test as well.
    Looking forward for the second part of the test at the topo f the voltage and I do expect the almost the same result especially after a few hours after the sunset. it will equalize.
    Just probably if you wanna test further on the active balancer , i suggest it would be:
    1) The balancer will keep balance the cell even all the cell are balanced.
    2) if the above true, that mean the balancer will drain current overtime especially with smaller capacity pack. I had a friend who installed this balancer for the 32650 4S 12V and leave it for few days, the pack drain to 2.++V.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Thank you. So far I'm really please with the result of the balancer. I think the balancer will turn off at a certain stage, either under a certain voltage or if the spread is below a threshold.

  • @lawrencebrewer8769
    @lawrencebrewer8769 2 роки тому +1

    Thank you

  • @3DLasers
    @3DLasers Рік тому

    Oh, I guess I’m standing outside of the wrong garage here. Your sign said FREE WI-FI and I still haven’t figured out the password yet and it’s freezing out here. I thought you said Austria… 🥶

  • @sithieu9009
    @sithieu9009 Рік тому

    After reading almost all comments here, some concern lower end while other worry upper end.
    This is my solution:
    Have 2 AB connected (parallel).
    The 1st balancer is setup trigger and balance on higher end of voltage. The 2nd balancer handle lower end of voltage.

  • @tiloalo
    @tiloalo 2 роки тому +1

    Voltage increase because voltage is not proportional to charge in lifepo4.
    So the battery that were good didn't loose as much voltage as the battery that were charged gained.

  • @2ClicksUp
    @2ClicksUp 3 роки тому +1

    Thanks for Vid & honest Info. PS; Consider the V increase from early morning to midday due to (Ambient & Chemical) Temperature increase...

  • @arrongrist868
    @arrongrist868 2 роки тому +1

    Just watched more of the balancer videos.
    Very odd how you were then getting imbalances caused.
    This seems contradictory to the idea of an active balance.
    Your videos are very useful, keep up the good work.

  • @wibla2578
    @wibla2578 3 роки тому +2

    Pack voltage is going up because you're putting energy into cells that are deep into the knee, while the energy is coming from cells that are not deeply in the knee.

  • @wayne8113
    @wayne8113 3 роки тому +1

    Thanks Andy

  • @samdelahaye6311
    @samdelahaye6311 2 роки тому +2

    Brillant vidéo, very interesting! Was wondering would a balancer work on a 24v lead acid battery with 14 x 2v cells to extend its life? If I understand correctly the balancer only looks at the voltage difference, not the type of battery? Many thanks, keep up the good work!!

    • @liam3284
      @liam3284 Рік тому

      Yes a lead acid bank would benefit, and you could avoid or reduce voltage in the adsorbtion phase of charge.

  • @stuartsmith945
    @stuartsmith945 3 роки тому +1

    It is not unreasonable that the voltage went up with the balancer running. Cell 6 was in the steep part of it's charge curve where most of the other cells were in a clatter portion. The balancer will affect the voltage of the higher charged cells much less than cell 6 so cell 6 increases in voltage more than the sum of the higher cells decrease in voltage.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Yes, I figured that later on after reading many comments here about it. It was not obvious when I looked at it at when recording.

  • @rtw8972
    @rtw8972 2 роки тому +1

    I really enjoy your very informative videos. Keep up the great work.

  • @mendo3427
    @mendo3427 3 роки тому +1

    Hi andy.
    I virtually have the same set-up as you.
    The main problem i am having is the solar power. When full sun is out i am pumping over 75amps into batteries.
    This then raises voltage very fast to and over the 52v , which inturn overloads the batteries and shuts off relay.
    This then upsets the victron MultiPlus-II and shuts down, loss of power

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      52V is far to low. Not sure about your settings but this is only 3.25V/cell. This could mean you're cells are only 30% charged when they reach this voltage. Try to set 55V or 56V in your solar charge controller. That would be 3.45V-3.5V/cell. That should work a lot better.

    • @mendo3427
      @mendo3427 3 роки тому

      @@OffGridGarageAustralia thank for your reply andy
      I should have explained in better detail.
      55.1v is my victron bulk/Absorption charge setting not 52v.
      When solar is pumping 75a into batteries voltage increases, on some cells it brings them to 3.6v and then over which triggers the quacc over load as it should as protection, this then cuts power, and MultiPlus-II doesn't like it, gets confused and shuts off inverter to which then has to be manually restarted.... pain

  • @frankammerman3296
    @frankammerman3296 3 роки тому +1

    Worked on F-4 Phantom avionic systems 1970 - 1974 USAF. Electrics were connected with Amphenol connectors. Looks like to me you could wire up your battery bank with a female multi pin connector and use a male matching connector to connect your BMS. If you wanted to have testing equipment connect to the bank they could be already wired ready to use. Would make it easy to change leads rather than reconnecting terminal rings on each cell every time you wanted to test or rig up something new or different. A strip of banana plugs would also work. Easy to check with a multimeter. Amphenol pins might be close to close together to be checking with multimeter. What do you think?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Well, that could be a solution. What my intension is though, I would like to NOT play around with the big batteries which are in production at some stage and rather have some test cells sitting on the workbench to do testing. Once testing is confirmed I may do these changes to the big batteries.
      The final battery won't have anything connected to the terminals any more as the balance leads for BMS and balancer will be connected to the busbar directly (M6 tap).

  • @1981dasimpson
    @1981dasimpson 3 роки тому +1

    wow so many sections to go into to check this and that they so need one display screen with all the controls like the raspberry pi gui but with more information and control buttons

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      The balancer itself has no interface, so that's a set a and forget device. Everything else is done through the Victron VRM and the occasional checking of the BMS.

    • @1981dasimpson
      @1981dasimpson 3 роки тому

      @@OffGridGarageAustralia yeah i think the active bms could be made to trigger with a voltage trigger so the voltages befor you wanted it to balance at you could have it work at

  • @mccyrille
    @mccyrille 3 роки тому +1

    With your raspberry, maybe you could turn on your active balancer with a relay (there is a pad "run" weldded on the active balancer) only when you are in the top or the bottom of your SOC ? It will correct the little deviation every day, but when you're on the flat curve, it doesn't work and don't transfert power between cells.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      The balancer runs 24/7 now for the test. If it does not balance in the flat part anyway, why should I make the effort and turning it off? The standby current is only a few mA, far less than for the Pi. Who would give the signal to start the balancer?

    • @mccyrille
      @mccyrille 3 роки тому

      @@OffGridGarageAustralia i think you shouldn't balance in top AND bottom... Only one no ? So you should disconnect it ? The rasp know thé soc ? For example if thé soc is under 10%, connect thé balancer ?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      @@mccyrille yeah you definitely only do top or bottom balancing.
      The Pi knows the SOC but then what? How?

  • @JacobLeeson-zk1ol
    @JacobLeeson-zk1ol Рік тому +1

    The voltage curve of the battery would actually cause a pack voltage increase.

  • @ingridpumberger1064
    @ingridpumberger1064 3 роки тому +2

    Hi Andy,
    With BMS + Active Balancer we are getting more cabling to the battery cells.
    I think about using a 16 x WAGO 2002-1781 3-conductor fuse terminal block; for mini-automotive blade-style fuses; with test option; 2.5 mm²; Push-in CAGE CLAMP®; 2,50 mm²;
    One wire from each cell to the terminal block. BMS and Balancer connected to the WAGO after the fuse.
    Easy disconnect for maintenance reasons by removing the fuses.
    Testing with multimeter etc via the WAGO Test pin.
    With this structured cabling it would no longer be necessary to touch the cells when doing maintenance, testing etc. and therefore mitigate the risk of shortcuts.
    What do you think about this idea ?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      I would be worried about resistance across all these additional connections when we measuring in the mV area for balancing.

    • @dollyone3714
      @dollyone3714 Рік тому

      i use blox FJ5N terminal block with no fuse.
      not for maintenance per se but for centralised wiring ease

  • @amateurwizard
    @amateurwizard 3 роки тому +2

    I'm curious, could you please do a video of a schematic of how you would set up the system if you were starting again with no limits. Could you have an active balancer beneath a BMS in a 24/7 system on all your batteries.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      You can definitely leave the balancer connected in parallel to your BMS. That is no problem.

  • @idontneedaname85
    @idontneedaname85 3 роки тому +1

    Over all voltage is rising because the more charged batteries (in your Situation) are closer the the flatter end for the curve. So if you move 5% soc from most to least charged cell you will have a net increase.

  • @firewraak8368
    @firewraak8368 3 роки тому +1

    Your video's are a great resource so thank you. Been following them here in the UK and I have been impressed with the detail.... so thank you for the time and effort you must put into the content creation and all the back office editing you must have to do before releasing them.
    Unfortunately when ordering from the AliExpress website there is a minimum spend which they don't tell you what that amount before you can use the discount code. Not sure if this is the same in other countries but here in the UK I have now purchase a 4S and a 16S balancer on separate orders and on both orders I was denied any discount. So, just letting you know it may be helpful if AliExpress actually said what the purchase amount has to be before the discount voucher kicks in.
    Many thanks again for the great content.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Thank you very much for your kind comment and feedback.
      I read this somewhere here already, the discount code does only seem to work over US$100 spent. Other said it gives you only $2 discount anyway, so probably don't bother about it.

  • @SpeakerKevin
    @SpeakerKevin 3 роки тому +2

    Looks like that balancer is doing it's job bottom balancing, but you're not going to like the out of balance situation that it created at the top when the cells are fully charged.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      I assume it will be exactly the same at the top now. Everything is balanced 😉

    • @SpeakerKevin
      @SpeakerKevin 3 роки тому

      @@OffGridGarageAustralia It will be ok if you stay under 90%, but if you get into the upper end curve, they will be all over the place due to slight differences in the cells.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      @@SpeakerKevin Not with the balancer attached, I guess.

    • @SpeakerKevin
      @SpeakerKevin 3 роки тому

      @@OffGridGarageAustralia That would be great if the balancer would take care of it, let's keep our fingers crossed.

  • @andreaskoumides9599
    @andreaskoumides9599 3 роки тому +1

    Great video, can you leave the balancer permanently on the battery?

  • @edfig_7
    @edfig_7 3 роки тому +1

    Andy, seems like you keep having issues with that BMS maintaining good balancing. I have a 48v, 16s, 90ah Lifepo4 system with a Daly Smart BMS. It is connected to a Growatt SPF LVM 3000w solar all-in-one inverter. The Daly 48v 100ah 16s SMART BMS is exceptional, maintaining balance between all cells usually under 10mv (under light load) and less than 100mv under high load. No need for active balancer. Please consider doing a test with this BMS. It has high and low temp protection too. Good luck and keep up the good work! (And Will is right)

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      I have to wait until the new battery is in place so I can take the existing one offline and can top balance it properly again (which I never did in the first place).

    • @edfig_7
      @edfig_7 3 роки тому +1

      @@OffGridGarageAustralia Top balancing is a painful, time consuming process, but well worth it in the end…at least it was in my case. I’m looking forward to your progress with the new system as I follow along in your journey. Good luck.

  • @trevortrevortsr2
    @trevortrevortsr2 3 роки тому +2

    SKU make a range of what they call a "capacitor BMS " instead of the more common (and cheaper) bleed balance BMS - it may be the answer to these big cell systems

  • @gregoryfierens001
    @gregoryfierens001 3 роки тому +1

    Andy - if you’re cold just put on a sweater. … or give some of your fans the idea to make you an ‘Off Grid Garage’ one 😜😂😂😂

  • @fredio54
    @fredio54 3 роки тому +1

    Glad you've caught up to where I was a year ago :-D Welcome! :-)

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      It's just a test though 😊

    • @fredio54
      @fredio54 3 роки тому

      @@OffGridGarageAustralia I can feel it coming closer, suddenly no more worries, just a max capacity scenario for your cells that actually partly solves the "more wear on weakest" issue by offloading load to stronger all the time and perhaps long term levelling the performance, too. You know it's good, proven in multiple vids, don't string it out any further, just install them for good and put a disable switch on it for your sanity/fear if you must.

  • @martehoudesheldt5885
    @martehoudesheldt5885 3 роки тому +1

    they work even better with higher cell volts (on top). and you can parallel them up also.

  • @1981dasimpson
    @1981dasimpson 3 роки тому +1

    it would be nice to see how the balancer and system do with everything left switched on how it should run just to see how well the system manages itself to imitate several days of really bad weather

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      Running for 6 days now...😊👍

    • @1981dasimpson
      @1981dasimpson 3 роки тому

      @@OffGridGarageAustralia yes but havent you been turning the controllers off?

  • @DanBurgaud
    @DanBurgaud 2 роки тому

    Active Balancers balances TWO ADJACENT CELLS by transferring charge from a higher voltage cell into a lower voltage cell. Some ABs have LEDs to indicate which pair it is working on making it a little fun to watch. Current is also depended on the voltage difference. A Balancer might be rated at 5A, but if the voltage difference is small so will the current flow. This is natural; you do not want to overdraw from one cell and overcharge the adjacent only to reverse it the next turn.
    I theorize we can use multiple balancers for faster balancing.
    ie, using two 9s balancers on a 16s bank. One AB connected to Cells 1~9 and the 2nd AB connected to Cells 8~16.

  • @Sylvan_dB
    @Sylvan_dB 3 роки тому +2

    I picked up a couple to play with. They just arrived yesterday. I'm familiar with the boost/buck style and am curious how this capacitor-only style will work. I sure wish I had the 32 channel 'scope I used at a prior job... I'd be monitoring those capacitors!

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      What do you expect is going to happen with the capacitors?

    • @Sylvan_dB
      @Sylvan_dB 3 роки тому

      @@OffGridGarageAustralia I expect they are going to charge to cell voltage or maybe 2x cells, then discharge into the lower cell of the pair. But I'm not sure and I'd like to know how it works!

  • @JeremyAkersInAustin
    @JeremyAkersInAustin 3 роки тому +1

    Hi Andy: At 6:00 it looks to me like the diagram is pictures with the capacitors face down (Notice on the diagram there's no depiction of the capacitors) and you're holding the board with the capacitors face up. This is why the B- and B8 wires are inverted. (Not mirrored as you said, which would be flipped left to right. It's inverted flipped top to bottom)
    at 11:20: It's not strange at all that the voltage would rise. You started out with your high cells sitting close to 3.2v. Pulling 1 Ah from a cell at 3.2v won't drop it's voltage very much, but pushing that 1Ah into a cell at 2.8v will cause that cells voltage to rise substantially. So the "sum" of the voltages (IE: pack voltage) is higher.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Yep, thanks. Both of your points are true. Just not obvious for me while recording 🤦‍♂️😉

  • @EddywaKenya
    @EddywaKenya 3 роки тому

    Batrium all the way!!!.... 2 years NO problem.... one install DONE. But only me.

  • @AveRage_Joe
    @AveRage_Joe 3 роки тому +1

    Fun times!!!

  • @rubenmuller5965
    @rubenmuller5965 3 роки тому +1

    Fantastic video, really changed my opinion, thank you!

  • @aflos3186
    @aflos3186 3 роки тому +1

    You’re shunt is on the right place, if you put it before the bms you can’t read your second batteriepack. Now you can just connect your second pack to the shunt in parallel. I got my cells a few months later than you and using a Daly bms it keeps the cells very good balanced.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      With more than 1 battery bank, it can only be connected like this. Every bank has its own BMS and shunt measures all banks.

    • @aflos3186
      @aflos3186 3 роки тому

      @@OffGridGarageAustralia yep, that’s what i done last week got my second bank with it’s own bms.
      Unfortunately the seller on Alibaba.com didn’t deliver the cells properly packed, got them quite much damaged. Don‘t get your cells from Heze Yixin Information Technology Co., Ltd. they promise a lot but don’t keep any off them. Delayed, incomplete and damaged delivery due to bad unprotected packing.

  • @bishwagit
    @bishwagit 3 роки тому

    Andy, it's time for you to build the second battery by using victron smart battery protect & active call balancer.
    Hope you understand....👍👍

  • @elektrobits3408
    @elektrobits3408 3 роки тому +2

    This balancer is impressive indeed. But what does balanced mean? You know, voltage is not everything. So why are some cells too low?
    If all cells are equal in terms of capacity, you are right. Balancing the voltage, no matter if at top or bottom, is always good.
    If one cell is lower in capacity, you get a problem. At the bottom end, its voltage is too low, so the balancer adds energy to it. Then at the top end, its voltage rises faster, and the added energy appears as an additional imbalancing. The balancer is not capable to align the charging level of the cells to each other. It makes it worse.
    If your cells don't have this problem, it will come when cells are getting older. I don't see an automated method to solve this. I would monitor the over- and undervoltage of a weak cell and then decide to add or remove some Ah manually ... until the cell must be replaced. This will come soon, the worst cell gets the highest stress.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      The cells are not all the same and never will be. Even they come matched from the supplier, they are not matched. You're dealing with 16 individual cells. And apparently, the drift and spread gets worse when they age over time.
      The balancer prevents the battery from being disconnected prematurely by the BMS as cell 6 would have triggered the cell low voltage disconnect. The same happens at the top if #6 goes to high.

    • @elektrobits3408
      @elektrobits3408 3 роки тому

      OK, very interesting. This makes it a very dynamic system. The missing capacity of the weakest cell is compensated by the balancer by adding energy at the bottom and removing this and more energy at the top. There is no continuous improvement but the weak cell is tossed from one end to the other. You think the balancer is strong enough for this? This is not what you have tested yet.

  • @ralph9987
    @ralph9987 3 роки тому +4

    You are converted. Question is though..... Can I leave the balancer installed permanently?

  • @KevIsOffGrid
    @KevIsOffGrid 3 роки тому +1

    You may be liking your balancer, but its maybe adding 0.25% of capacity at the bottom end. But remember when you were testing it was using more amps than it was using to top up other cells - I suggest you'll be losing the same capacity from balancing as you gain from having a balancer.
    However, I think they are worth having but not leave in all the time, but when you do a monthly/quarterly balancing plug it in. That's my plan, mines been in its box for over 6 months now ....

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +2

      Absolutely, the capacity gains is very little. The only thing it does well is prevent individual cells from running away and trigger the BMS to shut down.

  • @mjp0815
    @mjp0815 3 роки тому +1

    Balancing at the bottom AND the top is like pulling on a too short blanket to make it cover you just to put the feet in the cold.

  • @SkypowerwithKarl
    @SkypowerwithKarl 3 роки тому +3

    Andy perhaps we should stress that the only active balancer that you or I can suggest is the Hankzor or the Heltec “capacitive active equalizer” also known as “fly capacitor ”type. I can’t personally say anything about the other types, but they work differently (resistive energy dissipation) and some people have been disappointed. As you can see, the capacitor type wastes very little energy!

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Well, I'm not recommending people getting active balancers now. As you can read here in the comments, some people are just bottom balancing and are happy with that. Everyone needs to find their own way. I think the active balancer works well for me at the moment. But I would like to test further...

  • @The2000redrocket
    @The2000redrocket 2 роки тому

    i bought one of those active balancers for 24v setup. i just keep it plugged in. its always the same.

  • @grlimes
    @grlimes 3 роки тому

    On the connection diagram, you can see the MOSFETs and other components. So it is definitely the "bottom" side and all pins seems to be right.
    The reason for rised voltage is, the flat area in the charge/discharge curve. You need not much energy to charge a cell e.g. from 2.8V to 3.0V (diff=0.2V). The energy comes from cells with 3.2V and this cells will not drop down 0.2V. Maybe only down to 3.15V or 3.10V. So the total voltage will rise. Sometime the losses of the Balancer will decrease the total voltage.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Yep, both is correct, just didn't see that when I was recording. Thanks 😉

  • @1981dasimpson
    @1981dasimpson 3 роки тому +1

    this is where i think the run solder joint should be a switch so you can connect then turn it on to balance

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      But then you would need to check every here and then and make a decision. I'll just leave it running now. It turns off and on itself if needed.

    • @1981dasimpson
      @1981dasimpson 3 роки тому

      @@OffGridGarageAustralia a voltage trigger that measures the total voltage of battery that triggers a relay when set voltage is reached closing the run contact and setting the balance going this would work for the top balance you wanted befor at the set voltage you wanted where the battery bms would not play ball

  • @lexicase5642
    @lexicase5642 3 роки тому +1

    Well, I ordered one and the promo code comes up that the code is not valid because minimum spend isn’t reached. Total price including shipping was $71.35 so I ordered one anyway since my new 420ah setup is all used cells, so I’ll probably need it. Thankyou for your recommendation

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      Yeah, I wasn't aware that this code had a threshold in order amount. Stupid... it's only $2 anyway from what others said.

    • @lexicase5642
      @lexicase5642 3 роки тому

      @@OffGridGarageAustralia either way I really appreciate what you’re doing, the ad free content is also delightful. Beers coming your way next time I get paid 👌

  • @MiguelSilva-mb6mb
    @MiguelSilva-mb6mb 3 роки тому +2

    The problem in that balancer is that you cant define when you activate the balancing. If you have the balancer active in the midle range you will unbalance the state of charge at higher voltages.

    • @1981dasimpson
      @1981dasimpson 3 роки тому +1

      incorrect the balancer has a solder point to turn it on and off this can be controlled if left active it will always try to balance when mv range is above what ever it default variation is be it bottom middle or top it will always balance this is the point of them u have a 3s version i use on a solar light setup to keep cells in check as they are salvage and i must say it is doing the job perfect

    • @MiguelSilva-mb6mb
      @MiguelSilva-mb6mb 3 роки тому

      @@1981dasimpson ah ok. You can set a voltage and it actives on that...

    • @1981dasimpson
      @1981dasimpson 3 роки тому

      @@MiguelSilva-mb6mb you would need a voltage trigger but you could have the active balancer to turn on at what ever voltage you want with that trigger

    • @1981dasimpson
      @1981dasimpson 3 роки тому

      @@MiguelSilva-mb6mb as it stands at the moment it checks voltage of cells if they is 10mv difference it wil start to balance 10mv is the one that i have i think each one will trigger at slight different voltage due to imperfections in components but the active do a much better job then passive

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      The voltage is fixed. I thought it was 30mV to start up the balancer but cannot find this information any more. It's clearly below that.

  • @SirValak
    @SirValak 3 роки тому +1

    Awesome 😎 your videos rock. Pretty cool testing

  • @honumoorea873
    @honumoorea873 Рік тому

    Voltage can rise when balancing... cause a certain amount of energy in a cell, equivalent to 0.1v could be 0.2v in an other cell which would be at a different SOC...

  • @farida7777777
    @farida7777777 3 роки тому +1

    If your inverter is set to stop charging at a certain top voltage and switches of at a certain bottom voltage and the balancer keep your batteries balanced, it makes the bms redundant?
    Help me here if Im wrong, the bms does not come near keeping voltages balanced like the balancer. It only helps to stop charging and protect the battery from going to low.
    So why do you still need a bms?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      You always want a BMS. I show exactly this in the next video. The BMS is your safety net, your insurance for your battery. Never rely on just the charge controller or a balancer. There is always something which can go wrong and without BMS things go 💥 quickly.
      You can turn off balancing in your BMS though if you use another balancer.

  • @AG8000
    @AG8000 3 роки тому +1

    You need more Batterys and aktiv balancer.

  • @liam3284
    @liam3284 Рік тому

    Those birds were either yellow-throated miner or noisy miner. Sound like some baby ones around, baby gets looked after by the whole flock who become even more agressive.

  • @MiranPayman
    @MiranPayman Рік тому

    voltage of LFP increase with temperature. :) that's why it increased.

  • @davebutler3905
    @davebutler3905 Рік тому

    Good experiment!
    Thanks!

  • @harryharry8384
    @harryharry8384 3 роки тому +1

    try the smart BMS balancer again....
    set pack cut off to 14.45v
    cell cut off to 3,64v
    pack reconnect to 13,4v
    balance to static 3,4v and 0.005
    my pack has a low and high battery every charge, and each charge the high one trips the BMS at 3.64 and then static balance kicks in and within an hour or so kicks off around 3.5v with all cells balanced difference below 0.005v. if i trip the reconnect at 13.4v using a couple of second 20a load and the battery will start charging and all cells charge to a 14.45 v pack trip remaining balanced all the way up and all the way down to 2.7v low trip
    and then it simply repeats itself as charged as for some reason they drift out at top end every charge like your own..

  • @fredio54
    @fredio54 3 роки тому +1

    11:40 voltage is rising not because of recovery, but because if you take a Wh out of one of the higher cells the voltage hardly changes, but you put it into a low cell in a the steep part of the curve and the voltage changes dramatically. So the positive and negative changes in different cells are NOT equal because you're moving energy, not current, and not voltage.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      Yes, that is correct.

    • @fredio54
      @fredio54 3 роки тому +1

      @@OffGridGarageAustralia I know! I only correct you when you make false statements in the vids :-D

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      @@fredio54 that never happens at all 😂

  • @magicmanspaz
    @magicmanspaz 3 роки тому +2

    Mine showed up yesterday. yet to try it as my cells have been kept 0.014mv in check with my daly bms anyway. i have to say the active balancer pcb vs the passive pcb i can see the active pcb is nice and clean while the passive is a bit more dirty looking. but the passive balancer was like $10 vs $60 for the active. id trust the active more when it comes to not catching fire lol. I will test the unit and hopefully it performs well, i was and am still a bit skeptical on a balancer that is always balancing at all times since i have top balanced the cells so well this balancer if the battery sits in a low SOC for a period of time will effectively bottom balance then re top balance once full again and left long enough, not sure about tis being ideal. I think also from reading that older models of these balancer had weird voltage settings and wills video he may have had older versions that were junky vs the new ones more and more people seem to be having more luck with them performing well.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому +1

      Yeah, probably forget about balancing, top or bottom. These keep the battery in balance all the time. It seems to work great, I've got it attached since a week now and max deviation was 17mV during higher loads.

    • @magicmanspaz
      @magicmanspaz 3 роки тому

      @@OffGridGarageAustralia Nice. i have some used cells i will be testing the 8s version on. I have also designed a box for the 8s version> www.ebay.com.au/itm/274871525062?hash=item3fff9e9ec6:g:PnIAAOSwfPdg853K

  • @1981dasimpson
    @1981dasimpson 3 роки тому +1

    also you can have more then 1 active balancer to balance even faster as you running high capacity cells

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 роки тому

      Liek some people have 2 BMS connected to one battery?

    • @1981dasimpson
      @1981dasimpson 3 роки тому

      @@OffGridGarageAustralia not scene 2 bms on 1 battery pack but yes parallel active balancers to allow for a higher current transfer