DAIKIN PCB BURN'OUT // PAANO NANGYARI ????

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • THANK YOU MGA MASTER SA PAG SUBSCRIBE
    LIKE , COMMENT AT SHARE 😁👍🙏
    SERVICE OFFERED
    CLEANING ,
    REPAIR
    INSTALLATION
    DISMANTLING
    CHARGING FREON
    TRAVINO PRESSURE WASHER PROMO LINK
    Saturn Home Solution
    shoppee shop 👇👇👇👇
    shopee.ph/prod...
    SATURN HOME SULUTION SHOPPEE SHOP
    👇👇👇👇
    shopee.ph/skex...
    FB PAGE OFFICIAL
    ROS AIRCONDITIONING SERVICES
    LINK
    / donrosservice
    For business inquire email :
    👉ros.aireshop@gmail.com
    Lazada online shop
    www.lazada.com...
    MARAMING MARAMING SALAMAT PO SAINYO
    PATULOY PO TAYU SA ATING VLOG AT UPANG MAKAPAG BIGAY TULONG PO SA KAPWA PILIPINO

КОМЕНТАРІ • 101

  • @aranilosinigan1976
    @aranilosinigan1976 3 роки тому +4

    Wag kalimutan ang gamot mo master...God bless you all ways

  • @anchotv3432
    @anchotv3432 3 роки тому +1

    Ayus master nkabalik kna ingat lage master at pashout out narin..hehe slamat po

  • @JayJay-rb6rt
    @JayJay-rb6rt 3 роки тому +4

    Marami cause nyan, thermal runaway, component failure. Hindi sya MOSFET, IGBT yan, it is a hybrid ng unipolar (mosfet )at Bipolar Transistor.

  • @khaladkaringlalaki1144
    @khaladkaringlalaki1144 3 роки тому +3

    Tnx God ok kana master..😍😍😍😍

  • @romeocabanog7345
    @romeocabanog7345 3 роки тому +2

    Sana tolog na Yong recovery master God bless

  • @HeathenHacks
    @HeathenHacks 3 роки тому +3

    Yung Daikin ko 1 month pa lang sira na agad yung PCB. 'Di ko naman ginagamit ng sobrang tagal. Up to 8 hours lang yung pinaka-matagal na gamit ko dito. Tapos minsanan lang yun at 27C lang palagi yung temp settings. Ganun din nangyari, walang error code, pero sabi nung Daikin tech, CPU daw ang problem. May corrosion daw o baka nag overheat, nakita ko din na parang natuyo yung thermal paste niya. Posible din na factory defect kasi sealed yung unit bago i-install at yung pinaka test niya eh kapag na-install na. Buti na lang hindi inabot ng lockdown at napalitan na agad yung PCB.

    • @Ctto
      @Ctto 2 роки тому

      May binayaran po kayo?

    • @HeathenHacks
      @HeathenHacks 2 роки тому

      @@Ctto Wala po. 1 month pa lang po eh.

  • @soulflybsce
    @soulflybsce 3 роки тому +7

    3 years diba ang PCB warranty ng Daikin, kaya daikin ang pinili ko dahil dito.

  • @johngamboa2956
    @johngamboa2956 3 роки тому +2

    Mag ingat po kau master...wag po munang pwersahin..God bless po.

  • @mendozajonel130
    @mendozajonel130 3 роки тому +2

    Master yan lage problema ng daikin kung hindi mabutiki langgam nmn

  • @anthonyquiachon5037
    @anthonyquiachon5037 3 роки тому +2

    Boss san nakakabili ng plastic na pambalot ng unit pag cleaning? Anong sukat po? Salamat lods

  • @dommendoza
    @dommendoza Рік тому

    boss ano ma suggest mo na maganda brand na aircon split type matbay?

  • @joniparman1609
    @joniparman1609 2 роки тому

    boss taga san kayo? tanong ko lang gagana ba daikin na aircon pag nagbypass ng eev? sabi kasi nung tech na tumingin barado daw yung EEV kaya tinanggal niya tapos nirekta

  • @williambriones3722
    @williambriones3722 3 роки тому

    Sir, kolin 1.5hp split type. Ayaw sya umandar, meron lumalabas na F1 sa display. Pwede po magpa service sayo? Manuyo dos, Las Pinas. Thanks!

  • @jhonmathbajarias3049
    @jhonmathbajarias3049 3 роки тому +1

    check nyo master lodi ang outdoor fan motor nya

  • @ma.felizesariellevisittaci5222
    @ma.felizesariellevisittaci5222 3 роки тому +2

    Nasunog yan ROS.. sa sobrang baba ng settings ng remote kaya di kinaya ng IC ang init at sa sobrang tagal mag cut off ng compressor....

    • @rostv9393
      @rostv9393  3 роки тому

      opo master

    • @pilyangmaarte1551
      @pilyangmaarte1551 3 роки тому +1

      Anong ibig sabihin ng sobrang baba ng setting ng remote? You mean naka-18 deg po ba? Normal ko po kc 24-26deg and hindi ko din ino-ON ang fan kc malamig na. Ok lang po ba yun? And ano po meaning ng “cut off ng compressor.” 24/7 pa naman naka-ON a/c namin madalas.

  • @135azucena
    @135azucena 3 роки тому +1

    Ang akala ko ba 3years ang warranty ng board ng daikin? Yan pa nmn isa sa pinagpipilihan naming bilhin na aircon ang dali pala masira ng board nyan.

  • @banogaming5159
    @banogaming5159 3 роки тому +5

    Overheating kaya ganyan... Baka continous running outdoor or poor maintenance pero mukha namang malinis naman... My mga sensors naman yan kung sira ang fan motor and undercharged etc... So ang pinaka nakita ko diyan master in my own point of view... Baka sobrang tagal nang cut off... Sakto ba capacity sa room? Or pwede din master mahina ang hinang meron mga ganyan mahina ang hinang sa board nang ilang electritronic components kaya pag umiinit nag loloose or nagkakaroon nang parang bitak sa hinang pag loose siya nag iinit ang terminal na pinagkakabitan... Well yun lang tapos na warranty bili talaga bago si tumer...Sad

    • @Onepunchman312
      @Onepunchman312 3 роки тому +1

      Hello po maiingay pu ba talaga ang outdoor ng daikin? 1month user palang po

  • @marlonnuyte7373
    @marlonnuyte7373 3 роки тому +1

    Wag kalimutan yung maintenance mo pre..
    Pag D available si Romar pede ako🤭

    • @rostv9393
      @rostv9393  3 роки тому

      noted yan pre .. hehe ..

  • @nantechsupport
    @nantechsupport 3 роки тому

    Sa mga queen Series ni Daikin Sir. Nasa 3 years warranty daw po yung PCB niya? kasama po ba yang ganyang board sa 3 years?

  • @ronberbau6188
    @ronberbau6188 3 роки тому +1

    pre piem mo nga sken hm kuha ng client mo sa board

  • @bryanmetrue
    @bryanmetrue 3 роки тому +1

    Paps may tanong ako maaayos pa po ba yubg blinking ng lights sa lg dual inverter o palit na po yun. Salamat po tsaka isa pa po may nag linis po kasi ng ac namin tas napansin ko po na yubg fin po sa taas ay medyo nabaliko po makakaapekto po ba sa performance ng ac yun salamat po more power sa channel at business niyo po

    • @rostv9393
      @rostv9393  3 роки тому +1

      opo maayos naman po yan sir , basta malaman lang po ang error na nilalabas ng unit nyu po , sa pins naman po normal lang naman po un sa pag lilinis , wag lang po mayupi lahat

  • @marvinagustin5275
    @marvinagustin5275 3 роки тому +1

    tanong Lang master lodi...🙂Master dahil po ba sa breaker Yan..mataas po ba Ang ampere nung breaker master?

  • @staciezeki
    @staciezeki 2 роки тому

    Ano po ba ang mas matibay, daikin or Carrier?

  • @bennybuguina4402
    @bennybuguina4402 3 роки тому +2

    master mag ingat ka work mo 🙏🙏🙏

  • @micoleyanilanieves7776
    @micoleyanilanieves7776 3 роки тому +3

    Which is better po ba, LG Dual Inverter window type 1HP or Daikin D-Smart Inverter 1HP? Yung mas low ang consumption sa kuryente lalo na kung 12-20 hours naka bukas ang aircon. Anong ma rerecommend mo sir?

    • @Ctto
      @Ctto 2 роки тому

      Ff

    • @henry9820
      @henry9820 2 роки тому

      ff

    • @itsprivate5623
      @itsprivate5623 Рік тому

      Up

    • @vonoliverrobles4184
      @vonoliverrobles4184 Рік тому +2

      kung usapang patipiran, nasa record po ng DOE ay ang Daikin D Smart Series, Queen and King ang pinaka matipid sa lahat ng inverter split type. Hindi po LG dual inverter ang pinaka matipid, claiming 70% energy savings. It is all marketing lang po hehe

    • @mixsomedough1
      @mixsomedough1 4 дні тому

      ​@@vonoliverrobles4184kasama po ba ang smart prince jan?

  • @darwinsioson8606
    @darwinsioson8606 3 роки тому

    Sa tingin ko masyado dikit yung condenser sa pader. Tingin ko lng po.

  • @jeanelchrisdometita5367
    @jeanelchrisdometita5367 3 роки тому

    burn out na yan master palit bagong board ang laki pla damages

  • @joelhizon5671
    @joelhizon5671 3 роки тому +1

    Ka master magkano board ng Daikin.?

  • @zhed6419
    @zhed6419 Рік тому

    Bakit nasunog wala bang fuse ang board?.

  • @staciezeki
    @staciezeki 2 роки тому

    San na po ang part 2? Anong dahilan ng nasunog? Thanks

  • @kel6207
    @kel6207 3 роки тому

    1 year palang ung unit, hindi ba pasok sa warranty ung ganyang burnout ng PCB?

  • @promdi3805
    @promdi3805 2 роки тому +2

    Sir magkano po indoor board ng daikin 2.5hp?

  • @miyaw9360
    @miyaw9360 3 роки тому +2

    *anong daikin yan? bibili pa naman ako D series Queen.. madalas magflactuate kuryente samin. safe ba?*

    • @rostv9393
      @rostv9393  3 роки тому

      opo matibay po ang Daikin , ung lates model po ang bilin nyu mam salamat po

    • @miyaw9360
      @miyaw9360 3 роки тому

      @@rostv9393 *yes yung D series.. I think may protection yun sa voltage surge unlike jan sa vid nyo na nasunog yung PCB... old model po ba yan nasunugan just to clarify things? tnx*

    • @ansherinaespina2308
      @ansherinaespina2308 2 роки тому

      @@rostv9393 ano po specific model?

  • @arlenehayworth5378
    @arlenehayworth5378 2 роки тому +1

    Magkano ung board

  • @wellcruz7423
    @wellcruz7423 3 роки тому +1

    Sir magtatanong sana, yung bang outdoor unit nakainstall nang mas mataas sa indoor unit?

  • @javekyle5711
    @javekyle5711 3 роки тому +1

    Idol ilan po running charge ng R32? Liquid po ba? Salamat po

  • @marlonnuyte7373
    @marlonnuyte7373 3 роки тому +3

    Ayyy ganun pala pag wala electricity 🤔

  • @iainpipz
    @iainpipz 3 роки тому

    Buti nalang 3 yrs ang warranty ng pcb ng daikin tama?

  • @jhamstv5563
    @jhamstv5563 3 роки тому +1

    Master magkano ang kuha mo sa bagong Board ng daikin?

  • @jepoy10v
    @jepoy10v 3 роки тому

    Anung model ng Daikin yan boss

  • @kram04TV
    @kram04TV Рік тому

    Issue po ba tlga yan ng daikin?

  • @badEli2982
    @badEli2982 3 роки тому

    bk na turbo lagi ang andar

  • @iainpipz
    @iainpipz 3 роки тому

    Papakabit sana akong daikin akala ko matbay sila... LG ang next ko nakikita sabi nmn nubg isang shop madmi daw issues si LG ngayon alin po ba amg mgnda? 2hp pp sna kukunin ko 22sqm

    • @mjrojpurityofheart3912
      @mjrojpurityofheart3912 3 роки тому +1

      Authorize dealer ka po bumili.. LG and daikin maganda un.

    • @iainpipz
      @iainpipz 3 роки тому +1

      @@mjrojpurityofheart3912 salamt po nakapag pakabig din po daikin

  • @rahkizztah
    @rahkizztah 3 роки тому

    anong daikin model to?

  • @efrencordero3356
    @efrencordero3356 3 роки тому

    Shortage power supply

  • @bobbybagacina965
    @bobbybagacina965 3 роки тому

    Malala sinapit nyang board master dami sabog ah , malamang palit board na yan

  • @vanessadelacruz5199
    @vanessadelacruz5199 Рік тому

    totoo bang sirain po ang daikin na brand?

  • @incubus3286
    @incubus3286 2 роки тому +1

    Dba daiki 3years ang pcb warranty?

    • @rostv9393
      @rostv9393  2 роки тому

      ung bagong model po

    • @incubus3286
      @incubus3286 2 роки тому

      @@rostv9393 Lumang model ba ito boss? ano model tong mga daikin na units boss? hehe thanks

  • @banenenggg
    @banenenggg 3 роки тому +1

    Idol ask ko lang po kung normal po bang on and off po yung outdoor unit ng midea aurora split type namin bago palang po kase wala pang 1 month baka po masira or may sira na? Cool down po ba yon? Kase antagal mag on ulit tas nawawala yung lamig.

    • @rostv9393
      @rostv9393  3 роки тому +1

      naku sir di po normal yun , pa check nyu po sir sa technician

    • @SirBatario
      @SirBatario 3 роки тому +1

      Ganyan din akin same unit pag 25 degrees ng on and off yun outdoor fan. Lalo na kapag over temp yun kwarto.

    • @banenenggg
      @banenenggg 3 роки тому +1

      @@SirBatario hala same po, kaylangan below 20 lang temp nya pag tinaasan on and off na

    • @banenenggg
      @banenenggg 3 роки тому +1

      @@rostv9393 salamat poo.. Babae po ako lods

    • @rostv9393
      @rostv9393  3 роки тому +1

      try nyu po isetting sa 18'c tignan nyu po kung mamatay po ang unit

  • @michaelanthonygarcia814
    @michaelanthonygarcia814 2 роки тому

    Tanong lng po bkit po mahina minsan di na ririmanig ung tunog nya po?

  • @alphasiera1757
    @alphasiera1757 Рік тому

    Anong mas durable? Daikin, panasonic or kolin?

  • @badEli2982
    @badEli2982 3 роки тому

    Kala ko natibay ang board

  • @Iamianstein
    @Iamianstein 3 роки тому +1

    Bakit pabibilhin ang customer ng board diba may 5yrs warranty yan sa PCB? dapat i warranty nyo yan.

    • @rostv9393
      @rostv9393  3 роки тому

      ang 5yrs waranty po compressor po

    • @newavatarmaker
      @newavatarmaker 2 роки тому

      @@rostv9393 3 years un PCB dapat sagut pa rin ng may ari yan kawawa nman un bumibili hindi rin nila alam na madali masira yan

  • @kudos5820
    @kudos5820 3 роки тому

    low quality pla yan cgurdo nabasa yan

  • @alexiszerrudo6872
    @alexiszerrudo6872 3 роки тому +1

    master alam ko 3yrs warranty ng daikin pcb

    • @rostv9393
      @rostv9393  3 роки тому

      kapag po ung all voltage Guard na bago po no daikin master

    • @shebee5210
      @shebee5210 3 роки тому

      wala po bang warranty yun?

    • @newavatarmaker
      @newavatarmaker 2 роки тому

      @@rostv9393 nasasabi mo lng yan dahil hindi nangyari sayo at marunong kang gumawa pano hindi na papalitan un PCB dahil may nakitang langgam o butiki kalokohan yan bakit un ibang nilalangam hindi nman nasisira

  • @dmr5442
    @dmr5442 2 роки тому +1

    anu blita dto boss? nun pagplit ng pcb. gumana ba?

    • @rostv9393
      @rostv9393  2 роки тому +1

      opo sir ,

    • @dmr5442
      @dmr5442 2 роки тому

      @@rostv9393 thanks sir