This inverter brings 35 amperes from solar and 55amperes from battery Formula: Total amprs 35+55=90 90*batry volt 12=1080 watts on dc side load ha......load wise it is a best inverter. Ac side load 4.45*230=1023watts. Effeciency on load formula Output load/input load {1023/1080}*100= 94.75% Excellent inverter on load test.
1 جب موسم خراب ہو دھوپ نہ نکلے یا رات کو بیٹری ختم ہو جائے تو یہ واپڈا بھی خود شفٹ ہو جائے گا کیا؟ 2 جب بیٹری مکمل ختم ہو جائے گی تو پھر کیا یہ اس کو واپڈا سے چارج کرے گا یا سولر سے؟
Kya iss pr mein haier dc inverter 1.5 ton chala sakta hun direct solar plates sy? Start mein AC 7 to 8 amperes leta hy baad mein 2 amp tk aa jata hy. DC inverter mein UPS ka option hy jis sy solar plates pr chalaya ja sakta hy. Is ki price kya hy.? Please guide kr dein
Hello Faisal, I need help regarding my Homage UPS HVS 1214 which I bought a few months ago. The UPS turns off 5 to 6 mins after the power is off (due to loadshedding). It turns off after beeping, flashing and showing error 02 on the display. The load is minimal due to winter. The battery is almost new, healthy and well maintained with its tonic etc. What could be the issue and its solution? It would be so kind if you guide me through this. Thank you.
Bhai bagair wapda support ay akpa kya matlab hai? Kya yeh real time load sharing krta hai? Means solar output kam honay per solar plus wapda sy load chalaye.?
Salam sir g m thora confuse hu kindly guide me m 3 panel 150 watt lgana chahta hu to ap btaya k m mppt controller lgau ya pwm lgau or knse company k panel or kn c company k controolar lgau or priceb bta dain
Sir me ny kal 2414vertax leya ha. me es ko direct utility sy chala raha hu. Sir mera question ye ha k hamy kis tarah pata lagy ga k bettery full hu gae. Qk lcd per leka huwa ha charging.
Faisal sb. Es main single battery k saath DC Bracker use krny ka kaha giya hy positive wire k saath Poochna tha kiya yeah zaroori hy jabk main Daewoo battery 180 use krna chahta hoon Agar zaroori hy bracker tu bracker ki specifications aur demo pls dain thx a lottt
My Question! Let's Suppose we are using 3.2 kw inverter. At night their are no solar support and we are depending on Grids and Battery If we are using 2.5kw load on system and suddenly we face load shedding and can our batteries are capable of 2.5kw load? I think maybe lead acid batteries can take load but what's about Tubler batteries? Many person I saw in youtube they were installed 50 amp DC breaker in batteries. It's mean 24v X 50 amp = 1200va Please explain?
Sir , with batteries you need 100A DC breaker. 2500W load can’t last long. Batteries can run load but for 1 hour max. For long backup you need large battery bank.
Kia Hum bina solar kay use kr saktay hain ups ki Trhaan 2nd Yeh Phoenix ya others Tublar batterry ko Support kraiga q k batterry walay hazraaat keh rhay hain ap taizab wali batterry Lo yeh tublar ko support Nhi krta Hai
Salaam bro i baught this ups yesterday my battery gravity was down because of old ups i want to ask 1 thing that this ups will charge my battery full??
I bought this inverter today and tried browsing about this Inverter but nothing was available. Ultimately I reached your channel and bravo 💪 you elaborated everything nicely bro. Well-done keep it up 👍
Aoa brother mna b yai ups lagwaya hai lakin battery charge honay k baad b fan continue worl kar raha hai kindly guode me ya normal hai ya nai only 1 hafta hoa hai new lagwaya hai
Bhai!! 1214 model main solar or inventor k darmiyan dc breaker install karna jaruri hai. Agar han to kitney amp k (150w ki 4 plate parallel mai lanai hai)or Karachi mai kio acha electriction k contact # dey jis k vetex k function ki achi knowledge hon
Connect only four solar panels of 150watts in series to 82vdc and 7amperes. Then check the effeciency. It will give maximum effeciency of mppt range. Only support 600 watts solar.
Agr me is model k sth 6 plates lga ln 150 watt ki or din me 500 se 600 watt ka load ho or wapda b band tu kia ye load chalaye ga or sth sth battery b charge kare ga? Koi bhai rehnumai farmye
AoA bhai g ye inverter 12 volt ka hai jis py apne 200 MH ki battery use ki hai apne 150 volt ka solar use kiya jo 12 volt ka hai apne sare solar seres mai join kr k 24 volt kr diye kindly is ka ans dy de shukria
Sir , ye Inverter 12V hy but iska Charge controllers MPPT hy. Isko 100V tk solar input de skate han. 24V panels ko b support krta hy. Ye zyda volts pr zyda acha kam krta hy.
Assalam o Alaikum mery pass 630 wat ka homage inverter laga hoa hy kia me apna homage inverter upgrade kar sakta hon matlab replacement mumkin hy homage company sy plz informe me
Answer of battery amp reading. Very simple ... Agar battery stable.hy tu current battery ko ja raha hy aur agar battery low ho rahy hy tu battery sy current ly raha hy. Solar sy 55 volt aur 9 amp a rahy hain tu is matlab hy 490 watt solar dy raha hy. Aap ny 900 watt k load dala aur wapda connect nahi kiya matlab k battery sy jo readind ap ly rahe thy wo battery sy inverter ko wapis ja rahi thi.
Very Very Informative video. Love from karachi.. keep it up bro Allah bless you.. Question: UPS tou Final ho gaya best hai 1000watt pura output de raha hai per aap ne solar panel k bare mai kam bataya. I'm already using Homeage UPS but non-solar ab mjhe solar wala bhe lena hai lakin solar panels ki information nahi hai mjhe :( mono poly 150v 300v etc etc.. is UPS per konsi Solar Panel lagengi bas pls yeh bta dein. JazakAllah Khair
Sir , Its very good device. Please note one thing. Its fan runs continuously and due to 2 fans it noise is also a bit more than older models. You can attach 2 panels of 300W for better results.
Plzzzzzzzzzzzzz tell me why all brands 900 watts (homeage,Ns,Max) have same model,same screen,same price . Are they fake ? Or local manufacturers’s Using popular brands name.?.?..?
Bro genator pe ya ups charging pe q nhi jata power button k off kr k jata hai dairk nhi jata jaise wapda pe dairk ajata hai charging pe bina power off kiya
@@TechAlladin bro iss ka koi hal ha tu plz bata dein ya phir iss say koi aur acha ups bata dein jis ka fan full charge par off ho jata ho,ma iss homage ups 1214 sale kar deta hu,plz reply lazmi karna,
Very informative video per tall tabular Tx-1600 continuously kitny hours tk 750w run karskti hai nd Isper KES 1220s Kenwood run Karke video kindly share kijye
Battery charger setting 10 Amp pay sett hy ya 25 amp pay ??? Battery 200 amp single hy tu 10 Amp pay sett kryn or 14.2 pay cutt off Fan off ho Jaya kry ga I guess
please don't but. I buy it. my motors get a humming noise when shifted to UPS. the homage inverter 1214 does not give pure sine wave , it will give you simulated sign wave, which decrease the life of your appliances , and they got heat up when use. and also get more power then normal usage.
Bhai 54amps wo hain jo battery se inverter ko ja rahy hain matlab ap ne jitna load dala us py apki battery bhi consume hona shuru ho gai thi taqreeban 650watt load battery aur baki ka load solar py tha hope k apko meri baat samajh agai hogi
bhai ap 2 kam karo 1. only battery connection inverter me laga k Ampares check karo k iski IDLE per DC Ampare consumption kitni hai... 2. then PV connect karo inverter me...us k bad PV ki in k Ampare and battery terminal per Ampare note karo...us k bad batery k Ampares say IDLE consumption Ampares minus kardo....result samnay ajayayga ek video or banao jisme homage and maxpower dono ko uper batayay gayay tariqay pe check karo IDLE pe battery consumption kya hai kitne ampares PV say lay k battery ko kitna feed kara raha hai...then efficiency samnay aayaygi k kiska MPPT kitne % efficient hai..or public ko bhi asani hogi
Ma na AJ ak .homage. ka invrter lagia hia hia .wo trip kr jata hia ...ma na us ko wapda ni de ..BS Betry sa lagia hia or us pa fan lagia that ...es kr waja kia hia bhai
Can 2 plates of 585 watts be installed on this inverter? If so, should I install them in series or in parallel?
This inverter brings 35 amperes from solar and 55amperes from battery
Formula:
Total amprs 35+55=90
90*batry volt 12=1080 watts on dc side load ha......load wise it is a best inverter.
Ac side load 4.45*230=1023watts.
Effeciency on load formula
Output load/input load
{1023/1080}*100= 94.75%
Excellent inverter on load test.
Yes,,, but eska matlb ha Mppt is 35A not 55A
Thanks for your informative comment. Yes ye AC load k lye bht acha hy.
@@hman5291 Nahi esa kuchh Nahi h. 55A charge controller Ka matlab ye h k Inverter solar solar panels sy 55A tk Ka current receive it Sakta h.
1 جب موسم خراب ہو دھوپ نہ نکلے یا رات کو بیٹری ختم ہو جائے تو یہ واپڈا بھی خود شفٹ ہو جائے گا کیا؟
2 جب بیٹری مکمل ختم ہو جائے گی تو پھر کیا یہ اس کو واپڈا سے چارج کرے گا یا سولر سے؟
@@hman5291 mppt 55amp ka company claim kr rhi ha but ho ga nahi.....ye sirf 600watts tk solar ko support krta ha as like INVEREX 1.2KW solar inverter.
AoA, merey pass 150 watt ke 2 solar Hein inko series ya parallel men zyada acha Kam kren gi. Thanks
Kya iss pr mein haier dc inverter 1.5 ton chala sakta hun direct solar plates sy?
Start mein AC 7 to 8 amperes leta hy baad mein 2 amp tk aa jata hy.
DC inverter mein UPS ka option hy jis sy solar plates pr chalaya ja sakta hy.
Is ki price kya hy.?
Please guide kr dein
Mere pass NRE ka 1000 watt inverter hai jis ki booklet main likha hai k yeh MPPT hai. Kia NRE bhi aayse kam late ga. Reply must
Sir . NRE ka idea ni hy.
Hello Faisal,
I need help regarding my Homage UPS HVS 1214 which I bought a few months ago. The UPS turns off 5 to 6 mins after the power is off (due to loadshedding). It turns off after beeping, flashing and showing error 02 on the display. The load is minimal due to winter. The battery is almost new, healthy and well maintained with its tonic etc.
What could be the issue and its solution?
It would be so kind if you guide me through this. Thank you.
Sir ,
02 is a warning of Low battery. Please make sure your battery health is good. Check 03 no setting and set it to 25A.
bhai 1214 ka fan off hota hy ya hamesha chalta rehta hy pzz reply?
Bhai bagair wapda support ay akpa kya matlab hai? Kya yeh real time load sharing krta hai? Means solar output kam honay per solar plus wapda sy load chalaye.?
Brother 2424 model ko 60 ya 80 volt DC de sekty hain kya
Salam sir g m thora confuse hu kindly guide me m 3 panel 150 watt lgana chahta hu to ap btaya k m mppt controller lgau ya pwm lgau or knse company k panel or kn c company k controolar lgau or priceb bta dain
Brother, 3 panels han to ap apna budget dakh lain. PWM b theak chl jye ga. Panel kisi b achi company ke le lain, junction box chota ho jiska.
Bhai 1214 ki battery completely charged hony k bad ye automatically off ni hota na fan off hoty hen...??????
....???
Sir , Fan off ni hota. Ye 24hrs On rhta hy.
Sir me ny kal 2414vertax leya ha. me es ko direct utility sy chala raha hu. Sir mera question ye ha k hamy kis tarah pata lagy ga k bettery full hu gae. Qk lcd per leka huwa ha charging.
Sir , jb battery volts stable ho jain gy and battery bar move ni ho rhi ho gi to matlab battery charge ho gai hy.
Faisal sb. Es main single battery k saath DC Bracker use krny ka kaha giya hy positive wire k saath
Poochna tha kiya yeah zaroori hy jabk main Daewoo battery 180 use krna chahta hoon
Agar zaroori hy bracker tu bracker ki specifications aur demo pls dain thx a lottt
Can I install muhafiz voltage low/high protector with wapda 220 volts with this ups.
Bhai hmara solar khatam honey k bad ups start ho jata hai aesa Kya system kerain k direct wapda start ho jaye?
My Question!
Let's Suppose we are using 3.2 kw inverter. At night their are no solar support and we are depending on Grids and Battery
If we are using 2.5kw load on system and suddenly we face load shedding and can our batteries are capable of 2.5kw load?
I think maybe lead acid batteries can take load but what's about Tubler batteries? Many person I saw in youtube they were installed 50 amp DC breaker in batteries.
It's mean 24v X 50 amp = 1200va
Please explain?
Sir , with batteries you need 100A DC breaker.
2500W load can’t last long. Batteries can run load but for 1 hour max. For long backup you need large battery bank.
Bro ups ka cooling fan charging k bad bhee continously chalta rahata ha. Koi masla to nahi?
Ni sir. Ye koi issue ni hy. Company ne design ee esy kia hy.
Ais ups k sth 950Wat k panel connect ho stky h???
Kia Hum bina solar kay use kr saktay hain ups ki Trhaan 2nd Yeh Phoenix ya others Tublar batterry ko Support kraiga q k batterry walay hazraaat keh rhay hain ap taizab wali batterry Lo yeh tublar ko support Nhi krta Hai
Bro is k fans har time on rehtay hain even battery full charge bhi hojae to. ye aesa he ha ya mera inverter faulty ha?
Bhai is ka fan chalta rehta ha ya automatically battery charge honay kay bad band hota ha , please batai?
Sir . Chlta rhta hy all the time.
Sir is may lika hay kay DC input 12v
Awr solar input 15to 18 volt sir is hum ko konsay voltage in karnay hay
12V battery hy. DC solar input ap max 80V tk de skty han.
ASSALAAM.O.ALAIKUM.sub khairiat hai?bhai is pe dc inverter freezer chalayga?
W salam sir. G Alhamdulillah. Sir chl jye ga. Phr b freezer ka load check kr lain phly.
For DC Inverter AC or DC Inverter Freezer/Fridge, Use Pure Sine UPS only.
Sir g es par ham 580 k kitny solar laga saqty hy 2 ya 1 Canadian n tipe
I mean 450W 450W k 2 panel connect ho skty h???
Salaam bro i baught this ups yesterday my battery gravity was down because of old ups i want to ask 1 thing that this ups will charge my battery full??
Yes. This will charge it to full.
AOA, Sir I have same model of UPS. Its fan is continuously on. is it a fault ?
I bought this inverter today and tried browsing about this Inverter but nothing was available. Ultimately I reached your channel and bravo 💪 you elaborated everything nicely bro. Well-done keep it up 👍
Sir Your mobile number plz?
Muj se setting nahi hoo rahi plz help
Bro apka inverter k fans har time chaltay rehtay hain? battery full honay k baad bhi ups sound krta rehta ha?
@@32idiots brother iska solution apko mila kaya jo fan continue chalta rahta hai ku k mna b yai ups lagaya hai or yai issue a raha hai
Aoa brother mna b yai ups lagwaya hai lakin battery charge honay k baad b fan continue worl kar raha hai kindly guode me ya normal hai ya nai only 1 hafta hoa hai new lagwaya hai
@@Aahilkidunia nae bhai. fan chalta rehta ha continue
Bhai kam se kam kitni soler plates laga sakty hain? Aur conection kese karny hongy plz koi answer kardy mere pas beh yehe inverter hai abeh liya hai.
1000w ki koi bi solr plat lga skti ho
150 vat ki 3+3 ki saril bna k or 330 wali paril main 250w ki 2+2 saril bna k ok
@@nasirbashir8252 Thank you
Bhai!! 1214 model main solar or inventor k darmiyan dc breaker install karna jaruri hai. Agar han to kitney amp k (150w ki 4 plate parallel mai lanai hai)or Karachi mai kio acha electriction k contact # dey jis k vetex k function ki achi knowledge hon
Brother, ap panels 2+2 ki series me lgain. DC breaker 16 amp ka lga lain. Abi number ni hy karachi ka mery pas.
i have installed this product but its fan is running continously. Can u help me in this regard why it is running after full charged battery
Sir, Its fan runs all the time.
You can’t stop.
bhai g ye me ne lagwaiya h to is ka soler per jb charg hota h to wo kasy pta chly ga ke kitni charg ho rehi h ye nai pta chla
Sir , settings waly center waly button ko press krny se screen pr details change hoti han. Udr check kryn
Assalamu alaikum
is sath 545 watts ka solar panel Laga sakte hain
2414 SCC 1800 watts ka review day or kiya is par fridge chala saktay hy or he pure sine waves hy?
Sir , pure sine wave ni hy or fridge chl jye ga.
Can we run 12v battery which is 100am just like the regular ups..?
Inverex 1.2 or Homeage 1000 Watts main Best kon sa hy???? Bcoz Inverex 600 watts sy zaida PV sy nai laita mgr Loud Pora 1200 watts chla diata hy
Connect only four solar panels of 150watts in series to 82vdc and 7amperes. Then check the effeciency. It will give maximum effeciency of mppt range.
Only support 600 watts solar.
Thanks for valuable information. Will definitely try this combination.
As per ur advice I've contacted 4 pannels of 150 watt in series with vertex 1214 & it's performance is awesome
@@TheAamir87 you are welcome.
@@TechAlladin really?
@@TheAamir87 bhai series mei lga sakty hain?
Agr me is model k sth 6 plates lga ln 150 watt ki or din me 500 se 600 watt ka load ho or wapda b band tu kia ye load chalaye ga or sth sth battery b charge kare ga? Koi bhai rehnumai farmye
Ye 1 battery se chalay ga or kitny watts k solar panel laga saktay hy
Yes. 1 battery se. max 55A solar
AOA bro is k sath kitne 330 watt ki kitne solar panal attached kar sakte hain or kis tarhan panal lagane hon ge thanks
3 paril main
Phoenix tall tublar 230 APM Ki battery use karsaktay hy backup time?
Yes kr skty hn. Backup time depends on load.
sir battery full charge hony ki sorat mein kia notification ate hai?
Sir , battery bar stop ho jati hy.
@@TechAlladin yes sir wo dekha meine lekin battery bar kay niche charging phir bhi likha hua ku araha hai?
Mere pass AE Power ke 6 panel hay 170w ke may 3/3 ke serial Bana Kar laga Sakta hon koi maslah Tu nahi
AoA bhai g ye inverter 12 volt ka hai jis py apne 200 MH ki battery use ki hai apne 150 volt ka solar use kiya jo 12 volt ka hai apne sare solar seres mai join kr k 24 volt kr diye kindly is ka ans dy de shukria
Sir , ye Inverter 12V hy but iska Charge controllers MPPT hy. Isko 100V tk solar input de skate han. 24V panels ko b support krta hy. Ye zyda volts pr zyda acha kam krta hy.
Assalam o Alaikum
mery pass 630 wat ka homage inverter laga hoa hy kia me apna homage inverter upgrade kar sakta hon matlab replacement mumkin hy homage company sy
plz informe me
Is it is the autumatic inverter. From where we can purchase this
Yes its automatic. And great thing.
is main mppt charge controler nain hai ya pwm charger sy be bekar hai
Bhai is k sath soler series mei attached kry ya parallel???
Sir, Series me. 60V se zyda volt na dain.
Answer of battery amp reading.
Very simple ... Agar battery stable.hy tu current battery ko ja raha hy aur agar battery low ho rahy hy tu battery sy current ly raha hy. Solar sy 55 volt aur 9 amp a rahy hain tu is matlab hy 490 watt solar dy raha hy. Aap ny 900 watt k load dala aur wapda connect nahi kiya matlab k battery sy jo readind ap ly rahe thy wo battery sy inverter ko wapis ja rahi thi.
Yes. Sai kha apny.
Bhai jan mera same model hai laikin fan ka shore bohot hai. Ap ka kaisa tha ?
Ye sb shore krty han.
assalamoalykom bai jan is ups ka jo fan hia wo mosalsal chalta hai kiya kon k hamare gar mai jo on fan band nahi hota
Sir , ye fan bnd ni ho ga. Company ki setting is tra se hy.
Thanks you
Sir isi compani ka mere pas hai 24 volts ka or solar plate 2 hai 200 watts k to solar ka connection series me karo ya parallel me
Sir, Ap Series me lga lain. Max volts 70
Very Very Informative video. Love from karachi.. keep it up bro Allah bless you..
Question: UPS tou Final ho gaya best hai 1000watt pura output de raha hai per aap ne solar panel k bare mai kam bataya. I'm already using Homeage UPS but non-solar ab mjhe solar wala bhe lena hai lakin solar panels ki information nahi hai mjhe :( mono poly 150v 300v etc etc.. is UPS per konsi Solar Panel lagengi bas pls yeh bta dein. JazakAllah Khair
Sir , Its very good device. Please note one thing. Its fan runs continuously and due to 2 fans it noise is also a bit more than older models.
You can attach 2 panels of 300W for better results.
Sir 545 watts solar panel attach kar sakte hain
Kia is par 1 ton ka inverter ac chalya ja sakta hai???
Inverter AC UPS model chl skta hy.
Bhai 1800 watt wala kon sa ac asaami se chalai ga 1 ton ya 1.5 ton
Inverter AC UPS model with UPS device wala model chly ga.
kia iske sath fridge attach kr sakte haen
Bro can u guide us plz.
We want to use for Fridge. Which pure cinewave 1.2 inverter is best?
Plzzzzzzzzzzzzz tell me why all brands 900 watts (homeage,Ns,Max) have same model,same screen,same price .
Are they fake ? Or local manufacturers’s Using popular brands name.?.?..?
Sir , The manufacturer is same at back end. Its Voltronics Power. Quality is same and names are different.
Sir kya 150 watt ke 2 plate ko support krega ye ?
Yes.
Nd 150watt ki kitni plates install Karni parengi?
Kia yeh jo ups ky liye single wiring hoi hoti h ghar my us per connect kr sakty hn isy
G sir, Single wire pr connect ho jaty han.
UPS seller told me there is issue in this model. It PCM has error and company return back from their shop? Is it true?
Yes. It happened with us too. But Now all issues are resolved.
@@TechAlladin Now they are selling repaired UPS?
Can we run refrigerator on this ups
Bro genator pe ya ups charging pe q nhi jata power button k off kr k jata hai dairk nhi jata jaise wapda pe dairk ajata hai charging pe bina power off kiya
AOA. battery per 0watt ky sath fault alarm day rah hi. Kia fault hoga
Fault code ki hy ?
Fault code kia hy ?
Bhai i have Vertex 1800w Model But Wo bettry Charge hi kari ja ra h Full ho k Stop Nai hora Any Solution ?
Uski settings check kryn agr apny phly change ki han to.
Agr batteries purani hn gi to b issue ho skta hy.
24 wt k solar plat lag jynge es me?
G bhai
When battery is discharging there will be a - ve sign on clamp meter. When battery is charging there will be a positi e sign.
Can we run 300 watt fridge on this inverter??
Yes. No problem
Bhai iss ups ka fan chalta hi rahta ha,aur shor b zada ha,iss ka koi hal ha tu plz bata dein
Sir, Iska fan of ni ho ga.
@@TechAlladin bro iss ka koi hal ha tu plz bata dein ya phir iss say koi aur acha ups bata dein jis ka fan full charge par off ho jata ho,ma iss homage ups 1214 sale kar deta hu,plz reply lazmi karna,
Is this inverter can run fridge
Very informative video per tall tabular Tx-1600 continuously kitny hours tk 750w run karskti hai nd Isper KES 1220s Kenwood run Karke video kindly share kijye
as per manual Vmp for this invertor is 15-18 V, and Vmp of a 550 W panel will be more tha 40 V....so 550-watt k panels direct safe nahi rahein ge
Asslam o Alikum I purchased this model after watching your video it makes too much fan noise . is it a problem or is it normal??
Sir , Its normal.
World Alladin thanks for the reply
Battery charger setting 10 Amp pay sett hy ya 25 amp pay ??? Battery 200 amp single hy tu 10 Amp pay sett kryn or 14.2 pay cutt off
Fan off ho Jaya kry ga I guess
@@mustafakhalil4707 g is ka fan off ni horhy
میرے پاس 4 سولر پینل ہیں ان کی وائرنگ کس طرح کرنی ہے ۔سیرز میں لگانی ہے یا پیرالل لگانی ہے 150 واٹ کی چار سولر پینل ہیں
Solar pe maximum kitna Watts support karta hai?
please reply.
55A max input.
Bhai is me jo cooling fan lgy he wo bettry full hony pe off hoty he
Sir , ye off ni hoty.
Sir ye ups single wire pe install keo ni hota jub b L sy line leta hu to line N me ana start ho jati he aysa keo ho rha he
Modified sine wave or pure sine wave??
please don't but. I buy it. my motors get a humming noise when shifted to UPS. the homage inverter 1214 does not give pure sine wave ,
it will give you simulated sign wave, which decrease the life of your appliances , and they got heat up when use. and also get more power then normal usage.
Yes. You are right. Its not pure sine wave but simulated sine wave. But it is a quality product. Thanks for your valuable feedback.
Kia ya ups solar ke baghar chal sakta Hai?
Yes.
Sir inverter ur rah ha 3 times ur gaya barekers lagy huwa ha agar ap bata saky mujhy shukriya
Brother , Apki wiring me issue hy ya koi chez short circuit hy.
400, 350, 250 watt k panel laga saktay hy 900 watt Ki range m rehtay huy
Yes. Lga skty han.
Bhe ap na ya nhe dakya ka solar sa katne watt la rha ha. R as ka katne watt lane ki hamat ha
G sir, Solar se 9 Amp and 60V le rha hy.
Solar k bgair b isko use kr skty
din ko battery ky baghar chal sakta hia
Ni sir.
Is this available even now?
Agar battery discharge ho rahi hogi tw clamp meter -ve show karay ga, or agr battery charge ho rahi hogi tw current +ve hoga.
Bhai 54amps wo hain jo battery se inverter ko ja rahy hain matlab ap ne jitna load dala us py apki battery bhi consume hona shuru ho gai thi taqreeban 650watt load battery aur baki ka load solar py tha hope k apko meri baat samajh agai hogi
Yes. Sai kha apny. Load pr battery b discharge ho rahi hy.
Shukria sir hum Karachi say laly gay
bhai ap 2 kam karo
1. only battery connection inverter me laga k Ampares check karo k iski IDLE per DC Ampare consumption kitni hai...
2. then PV connect karo inverter me...us k bad PV ki in k Ampare and battery terminal per Ampare note karo...us k bad batery k Ampares say IDLE consumption Ampares minus kardo....result samnay ajayayga
ek video or banao jisme homage and maxpower dono ko uper batayay gayay tariqay pe check karo
IDLE pe battery consumption kya hai
kitne ampares PV say lay k battery ko kitna feed kara raha hai...then efficiency samnay aayaygi k kiska MPPT kitne % efficient hai..or public ko bhi asani hogi
Ok brother. Inshallah ye check krta hn. Apny bht acha point btaya hy.
Janab 1800 w ka inverter minimum 150 watts ki kitne solar panels par work kare ga
Sir , Minimum apny load ko dakhyn. 4 panels to zaror lgain.
Panel k liye kitne (M) ki wiare use ki h apne...???
4mm
6or8mm
Without battery working ???
no
No sir. Battery zarori hy.
Batri full hony k bad kia is ups ka fan band ni hota kia???
bhai same question. mene bhi lea ha aur fans off he nae hotay sara din chaltay rehtay hain
Ups our solar 1 sath hai esmai ?
Solar Attached hy UPS k sath video me.
And ye Solar wala UPS hy
Sahib homage acha he ya maxpower?
Ye model dono same factory se bn rhy hn.
@@TechAlladin price difference itna q hy.... Max btvn vertex.?
Ma na AJ ak .homage. ka invrter lagia hia hia .wo trip kr jata hia ...ma na us ko wapda ni de ..BS Betry sa lagia hia or us pa fan lagia that ...es kr waja kia hia bhai
MashAllah bro.. great effort
Shukria sir