How to Replace Your Central Heating Pump, Step by Step Instructions. Everything You Need to Know.

Поділитися
Вставка
  • Опубліковано 1 сер 2024
  • I will show you how to replace your Central Heating Pump, with easy to follow step by step instructions with out draining your system, even if you have to change the pump valves.
    I cover everything you should need to know, to include cutting off your valve nuts, valve not closing properly so water keeps coming out, the difference between gate valves and ball valves, pump speeds and lots more.
    If you want to support me further then please leave a Donation in my “TOOL BOX FUND” that is really appreciated.
    www.paypal.com/donate/?cmd=_s...
    Please don’t forget to SUBSCIBE and click the BELL for notification of my new videos.
    Share me with your friends.
    Visit my Web site at www.markballard-ltd.com
    Where all my videos are categorised to make them easy to find, along with links to parts and products I recommend.
    “As an Amazon Associate I earn from qualifying purchases”.
    Links To Other Help Videos.
    VIDEO: How and Why you should add "INHIBITOR" to your heating system. Including "System Cleaner" and other "Chemicals"..
    • How and Why You Should...
    How to bung your loft tank so you don't have to drain the system.
    • Loft Tank Plugging / B...
    TOOLS, Einhell Classic TC VC1930S Wet & Dry Vacuum Review.
    • Einhell Classic TC VC1...
    This is the Vacuum I use "Einhell Wet and Dry Vacuum".
    Einhell Classic TC VC1930S 30L Wet & Dry Vacuum Cleaner 230V.
    www.markballard-ltd.com/recomm... (Amazon).
    10 Money Saving Heating Tips. Simple Things You Can Do Which Will Improve Efficacy Save Gas / Money.
    • How to Reduce Your Gas...
    How to Balance your Heating System. Which will reduce your Gas Bill.
    • How to Balance Your He...
    Is your boiler continuously losing pressure. What's the problem.
    • Boiler Keeps Losing Pr...
    How to Fix a Radiator NOT Getting Hot! Most common Reason.
    • How to Fix Cold Radiat...
    VIDEO: How to replace a leaking Radiator Valve. With out draining the system.
    • Replace Radiator Valve...
    How to replace a radiator valve EXTENDED version.
    • Replace Radiator Valve...
    How to replace a Radiator with out draining the system.
    • How to Replace a Radia...
    VIDEO: How to remove a radiator for decorating
    • How to Remove Radiator...
    VIDEO: How to refit a radiator after decorating..
    • How to Refit a Radiato...
    How repair leaking radiator blanking plug.
    • How To Repair a Radiat...
    How to flush out your radiator.
    • How to flush Out a Rad...
    How to Paint/Spay your Radiator. with a sparkle finish.
    • Radiator Spraying / Pa...
    How to clean the MagnaClean Professional 1
    • How to Clean the Adey ...
    How to clean the MagnaClean Professional 2
    • MagnaClean Professiona...
    MagnaClean Professional 2, How to add Inhibitor.
    • MagnaClean Professiona...
    The Gas Safe Register.
    www.gassaferegister.co.uk
    Chapters
    0:00 How to replace a Central heating pump Introduction.
    2:04 Replace Heating Pump. Switch off Power.
    2:45 Replace Heating Pump. Closing Valves.
    5:07 Replace Heating Pump. Ball Valves and Gate Valves.
    5:50 Replace Heating Pump. Valves Nuts.
    8:57 Replace Heating Pump. Pressurised System.
    9:11 Central Heating Pump Valves.
    11:17 Replace Heating Pump. Cutting Off Nuts.
    13:19 Replace Heating Pump. Bunging Loft Tank.
    15:39 Replace Heating Pump. Pump Direction of Flow.
    17:37 Replace Heating Pump. Removing Pump Valves.
    23:09 Replace Heating Pump. Wiring Up Heating Pump.
    24:21 Replace Heating Pump. Adjusting Pump Speed.
    If you want to support me further then please leave a Donation in my
    “TOOL BOX FUND”.
    www.paypal.com/donate/?cmd=_s...
    I've been a gas engineer for over 20
    The aim of my channel is to help you with your central heating and plumbing systems. From the general operation and maintenance to the more advanced fault finding, installation and repairing of your systems.
    Please don’t forget to SUBSCIBE and click the bell for notification of my new videos. share me with your friends.
    And if you have a similar story or a question you can leave it in the comments.

КОМЕНТАРІ • 48

  • @shaunaLOVESmimi
    @shaunaLOVESmimi Місяць тому

    Great video. Changing one for the first time tomorrow and this has really helped. Thank you!

  • @abadcock66
    @abadcock66 Рік тому +9

    This video was a life saver for me. The nice thing about it is that you take the time to show everything that could go wrong and how to deal with it, compared to other videos that just show how to change a pump in an ideal situation. Thanks to you I was able to pluck up the courage to take the job on and I was prepared for every eventuality. The biggest challenge I encountered in the end was finding a big enough wrench but luckily managed to borrow one from a neighbour. Got the old pump out and replaced in around an hour, no leaks and all good. Moreover, my wife thanks you too because her toes are warm again. Happy wife, happy life!

  • @meganjb10
    @meganjb10 3 місяці тому +2

    I have tried about ten vidios about changing a pump, every one are clowning about playing to the camera or talking about things not related to pump ,he is getting on with the job

  • @fostexfan160
    @fostexfan160 6 місяців тому +1

    Excellent video. Well presented and detailed. It's given me the knowhow to tackle a pump change when the weather breaks. Thanks for posting

  • @LowreyContractorsUK
    @LowreyContractorsUK Місяць тому

    Thank you for showing the reality.
    It’s the bastard jobs we need help on.
    Anyone can work on a text book perfect system with all the valves new .
    It’s trying to repair the badly positioned, badly corroded, badly installed where we need help and trade tips. Thanks

  • @djjones11
    @djjones11 6 місяців тому +2

    Thanks, fixed mine 👍

  • @paulhayestiling2214
    @paulhayestiling2214 9 місяців тому +1

    Excellent video Mark!!! I have to replace a pump and both valves are banjaxed, this video is going to be a godsend. All the best. Paul in Ireland

  • @jimbo2629
    @jimbo2629 3 місяці тому

    Exellent detailed video

  • @michaelbrogan4164
    @michaelbrogan4164 7 місяців тому +1

    Excellent video and explanation

  • @mb-3faze
    @mb-3faze Рік тому +2

    FYI for anyone wondering, Mark cut and replaced the electrical connection to the pump. That existing wire is solid-core "twin and earth". The reason why he replaced it with so-called "flex" is because the pump can vibrate and solid core copper wires can, over time, work-harden and break. (Although, honestly, this will probably take longer than the life of the pump.) Still, "flex" is flexible because it has multi-core thin copper strands and that makes it much less likely to fail catastrophically with vibrating connections.

  • @Neo-mw1pp
    @Neo-mw1pp Рік тому +2

    This is an excellent video in comparison to other "replace your central heating pump" on youtube, particularly like how you went into detail on the valves...very informative nice one! 👌

  • @ldaly4621
    @ldaly4621 9 місяців тому +1

    Excellent thanks

  • @davidcoleman6032
    @davidcoleman6032 2 роки тому +2

    Superb video Mark! Nice that you cover the 'sods law' problems that we all come across and not just the theory. Very enjoyable watch.👍😉

  • @TonysTechAndCars
    @TonysTechAndCars 2 роки тому +2

    Fantastic video!

  • @Dg-zj6jo
    @Dg-zj6jo Рік тому +1

    what a nightmarew job for a simple thing needs redesigning to make it simple great video

    • @zeez4178
      @zeez4178 4 місяці тому

      Yes and under the boiler needs to be in a plastic tub incase of leaks

  • @petemc5070
    @petemc5070 Рік тому

    Incredibly detailed and thorough - thank you.

  • @ryandow3954
    @ryandow3954 2 роки тому +1

    Thanks for taking the time to make these videos mate, really helpful!

  • @robyates132
    @robyates132 Рік тому +1

    really helpful video...just need to do the job now :)

  • @surindermann1394
    @surindermann1394 Рік тому +1

    Good old classic screw driver you use to turn off the valves

  • @lorrainedimmock4096
    @lorrainedimmock4096 Рік тому +1

    Thanks for making this video, the only thing that worries my is the power switch, I have an on off switch to the pump, but would feel happier if the whole house was switched off, ..!
    Will the pilot light go out if I do this, ? Have not tried it yet, but getting the light to re- light can be a nightmare on my 25 year old boiler...

  • @mb-3faze
    @mb-3faze Рік тому

    Excellent video... You carefully wrapped ptfe tape round the bottom olive but didn't on the top olive. I've never put ptfe tape on compression fittings - never even thought about it - but can't do any any harm I guess! I've just had to take my pump off - it had frozen, literally, sub-zero water. After defrosting it, it still didn't pump well and the boiler was upset. As you suggested it had been put on by a gorilla so I siphoned the water out of the header tank (lol - 30 year-old water -with associated sludge, interior radiator rust and insects). I just undid the smaller compression fitting nuts and pulled it out complete with the shutoff valves. Then I removed the motor/impeller bit by undoing the 4 allen bolts to clean out the crud that was stuck in the impeller. Stuck a 13A plug on the wires and tested it in the sink. I can see why these pumps are generally mounted vertically - it has almost zero ability to draw the water horizontally - except when fully submerged (just the water in and out was submerged). My pump is mounted horizontally and it's clear that it wasn't broken - clearing the crud from the impeller probably helped but the main reason was that a bit of air had got in and that rendered the pumping action almost useless. Took most of the day but I probably saved myself £300 (and the rest).

    • @ayz01
      @ayz01 6 місяців тому

      Because on the top one he just put joining compound on. Both do the same job

  • @TheQwaqa
    @TheQwaqa Рік тому +1

    When replacing the gate pump valve due to corrosion should the new valve be set to fully open?
    Thanks!

  • @ravington666
    @ravington666 Рік тому

    Just wondering if these newer pumps need bleeding and how you would do this as there doesn't seem to be a bleed screw like the older ones.

  • @peterwhite51
    @peterwhite51 Рік тому

    Jut remove the four socket screws on the pump body, to change the orientation of the control panel(With system dry!)

  • @glennpowell3444
    @glennpowell3444 Рік тому

    So from my exprience changing a 3 way diverter valve I would on an F an E drain down prior anyway for a pump.Yes bleeding it all can and is a pain but I know its empty before I start.I tend to tie the ball valve up and let it empty if no isolation valve is on the the system to to headers and even if they are I never trust them.

  • @paulbentley849
    @paulbentley849 2 роки тому +1

    How to set pump speed because the rads to warm up to quickly but the last rad warm slow

  • @valiantsharts3660
    @valiantsharts3660 Рік тому

    Great video, thank you. Do the valves come with the pump? If not, which ones did you use as replacements?

  • @ashleyblair1912
    @ashleyblair1912 Рік тому

    Hi
    If the pump gets to hot is that the speed or blockage on a new pump

  • @stevefinn141
    @stevefinn141 Рік тому

    How do you service a valiant Pro plus boiler.

  • @rpbartlett
    @rpbartlett Рік тому +1

    I've got an older Grundfos pump. But i cant work out why mine is constantly on. HW & CH work fine when called. Any thoughts or suggestions?

    • @mb-3faze
      @mb-3faze Рік тому +1

      Not an expert but on mine the boiler controls when the pump turns on. Yours could be wired incorrectly. Check to see if the pump goes off when the boiler is off (usually a switch is available on the boiler).

    • @michaelbrogan4164
      @michaelbrogan4164 7 місяців тому +1

      S type heating systems are fully pumped. Both heating and hot water.

  • @corkion
    @corkion 8 місяців тому

    can any one tell me why i have hot water coming out of my vent pipe and in to my header tank in the attic this happens when the pump comes on

  • @b1h2u3p4
    @b1h2u3p4 Рік тому

    Why always wear orange 🍊

  • @kelvinellis9155
    @kelvinellis9155 2 роки тому +2

    These are good videos mate but it's taking work from us gas safe engineers. The general public shouldn't be messing with central heating

    • @julianwebb8712
      @julianwebb8712 2 роки тому +2

      Exactly, pass on these skills and this knowledge to an apprentice not Joe public !

    • @davidcoleman6032
      @davidcoleman6032 2 роки тому +13

      That's all well and dandy, but in my area,trying to get hold of a heating engineer to do a relatively straightforward job like this,there's more chance of getting Lord Lucan! Plus there's quite a few diyers who do everything by the book and are more than capable. Different if you're dealing with the boiler itself.

    • @MarkBallardLTD
      @MarkBallardLTD  2 роки тому +18

      In my experience people who want to DIY it, will do it with or with out instructions. I find as many people who now feel they can do this job them selves after see my video, there will be and equal number after see my video not wanting to do the job.

    • @chrishard7616
      @chrishard7616 6 місяців тому +3

      That’s a pretty dumb statement. I think competent people should be doing what they can to maintain their heating systems. A lot of this stuff is fairly basic stuff that most people can manage DIY.

    • @zeez4178
      @zeez4178 4 місяці тому +1

      You rip people of and don't charge fair prices so stop moaning

  • @jimsmith4320
    @jimsmith4320 Рік тому

    Too much talking: get on with it