  • Detail Description of the Components of Oily Water Separator and Operating Procedure.
    Maker : HEISHIN
    Model : HFM - 200
    #Oily_Water_Separator #Heishin #HFM_200 #marineengineering #engineroom #marpol #operation

КОМЕНТАРІ • 36

  • @htetpyaesonelin4075
    @htetpyaesonelin4075 10 місяців тому +2

    Thanks sir

  • @MechanicalEfficiency
    @MechanicalEfficiency 7 місяців тому +1

    ❤❤❤

  • @nayvala3820
    @nayvala3820 2 роки тому

    Thz Sir for your detail demonstratio.It's my first time seeing 4 stages OWS. All of the ships I work are all fitted Two Stages. First stage gravity separation with heating assit and then Coalescer filter to OB. I am looking forward to your next content.
    Thank You .

  • @aungkyawkyaw5315
    @aungkyawkyaw5315 Рік тому +1

    thanks sir

  • @nyeinchenaung4981
    @nyeinchenaung4981 2 роки тому

    Thank you Sir

  • @katsuragisan1
    @katsuragisan1 7 місяців тому

    Hi.Fresh Water valve must be kept open on Monitor 7:41 during pumping out bilge?

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  7 місяців тому

      Sure.
      Purpose of this fresh water is -
      1. To wash down stains on sensor. And also, to calibrate sensor with fresh water, after 15ppm alarm activates due to high oil content.
      There is 3-ways valve located before measuring cell (here you say monitor). One from sample line that is NO. Another one is from fresh water line that is NC. And the last one is directed to measuring cell.
      When oil content is higher than 15ppm, sample line is closed and fresh water line is opened to sensor for above purposes.
      Hope you will satisfy my answer. If not, leave message in comment. Thanks.

  • @mankeepsrolling
    @mankeepsrolling 8 місяців тому

    Sir i have a doubt. I believe"ll be cleared once you read these questions.
    Why freshwater valve to o.w.s is given?
    Why sample drain valve should be in closed position? Btw Where is it draining sample water? Is it in B.H.T or B.S.O.T?

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  8 місяців тому +2

      1. To wash down stains on sensor with fresh water. And also, to calibrate sensor with fresh water, after 15ppm alarm activates due to high oil content.
      There is 3-ways valve located before measuring cell. One from sample line that is NO. Another one is from fresh water line that is NC. And the last one is to measuring cell. When oil content is higher than 15ppm, sample line is closed and fresh water line is opened to sensor for above purposes.
      2. Measuring cell has 3 ports. Sample Inlet, Sample Outlet and Drain. Sample inlet located at the bottom of sensor, just above the drain valve. Sample outlet is at the top of measuring cell.
      If drain valve is opened during operation, sample water can’t pass measuring cell and all sample will be drained through drain pipe.
      3. Sample water from outlet of measuring cell drains to tray of OWS. From there, goes to BHT. Manual drains from 2nd, 3rd and 4th stages leads to BSOT. And also, auto drain from 1st stage goes to BSOT.
      Hope you may satisfy for my answers. If you doubt something, can contact.

    • @mankeepsrolling
      @mankeepsrolling 8 місяців тому

      Thank you very much sir. Really you cleared my all doubts.
      Thankyou sir again.

  • @ashishmishra2144
    @ashishmishra2144 6 місяців тому

    Sir (1) at 4:41 , when you opened fresh water valve, then this FW is going to photocell and then draining to ows or it is also going to automatic 3 way valve ? (2) Do this FW valve continue to be in open condition when ows is running ?

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  6 місяців тому +1

      To wash down stains on sensor with fresh water. And also, to calibrate sensor with fresh water, after 15ppm alarm activates due to high oil content.
      There is 3-ways valve located before measuring cell. One from sample line that is NO. Another one is from fresh water line that is NC. And the last one is to measuring cell. When oil content is higher than 15ppm, sample line is closed and fresh water line is opened to sensor for above purposes.

    • @ashishmishra2144
      @ashishmishra2144 6 місяців тому +1

      @@MoeMyintShein_MMU So sir, it means this FW will keep cleaning photocell when ows is running? For how many second this FW valve will open and do flush and then again get close ?

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  6 місяців тому +1

      @ashishmishra2144
      Most OWS - 60 Seconds

    • @ashishmishra2144
      @ashishmishra2144 6 місяців тому +1

      @@MoeMyintShein_MMU So sir, it means that whenever ppm>15, tyen solenoid valve will shift towards fw sample valve line and my Oily bilge water will not come for 60 seconds. FW will come for 60 second for flushing and after that 60 second flushing, again solenoid valve will shift to oil bilge water sample valve !!
      Is it sir, am I correct or some corrections please ? 🙏

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  6 місяців тому +1

      @ashishmishra2144
      That’s right !
      Smart thinking !

  • @mec6953
    @mec6953 2 роки тому

    Sir, good day. how are you?
    i have a question. pls reply.
    At which air pressure the pneumatic 3way v/v operates located on the final discharge side? Is it 7 bar?

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  2 роки тому +1

      Hi Good Day - MEC.
      Control Air Pressure is 7 Bar.
      Have a wonderful day !!!

  • @ashishmishra2144
    @ashishmishra2144 7 місяців тому +1

    Sir, what is the the meaning of biggest size float on surface and discharge regarding 4th chamber ?

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  7 місяців тому

      It means Big Size Oil Particles that is floating on the surface of oily water in 4th Chamber.

    • @ashishmishra2144
      @ashishmishra2144 6 місяців тому +1

      Thanks sir @@MoeMyintShein_MMU

    • @ashishmishra2144
      @ashishmishra2144 6 місяців тому +1

      And sir what is the meaning of manifold valve to ows, as you already open pump discharge valve , so what is this manifold valve to ows ? @@MoeMyintShein_MMU

    • @MoeMyintShein_MMU
      @MoeMyintShein_MMU  6 місяців тому +1

      Good Question, Mishra.
      Bilge water comes out from Bilge pump because you had opened pump discharge valve.
      Now, Bilge water reaches to manifold.
      From manifold, bilge water can flow to many places. If you wish to flow to OWS, open valve to OWS and close other valves.
      If you wish to transfer to Primary Bilge Tank (optional), open concerned valve and close others.
      If you wish to transfer bilge water to bilge holding tank, opens valve to BHT and close others.
      Hope you will understand in brief.

    • @ashishmishra2144
      @ashishmishra2144 6 місяців тому +1

      @@MoeMyintShein_MMU I understood sir, thanks much. In my last ship, piping arrangement is different from this one. So I asked, but yes point noted, it depend upon ship design. Thanks sir