  • @dorschn89
    @dorschn89 6 місяців тому

    Can you tell me what the numbers in mm are at the top of the display? Is that something to do with the grind size or the burrs?
    Thanks!

    • @primacoffeeequipment
      @primacoffeeequipment  6 місяців тому +1

      It is a reference to help guide you back to the programmed grind setting in case the adjustment collar is moved.

  • @Andrew-sj1fm
    @Andrew-sj1fm 10 місяців тому

    Hi, I recently changed the burrs on my e65s gbw. Do you know how to reset the burr health? Thanks

    • @primacoffeeequipment
      @primacoffeeequipment  10 місяців тому

      The procedure requires entering the service password: 9512867, then go to Service ----> Confirm Service Reset Burr Health. This will remove the "Service Required" message that pops up on the main screen. You can go into the statics menu and reset the Kg count as well. This does not require entering the service password.

  • @kuksgarage2715
    @kuksgarage2715 Місяць тому

    Having issues where coffe grinds come out are all over the place

    • @primacoffeeequipment
      @primacoffeeequipment  Місяць тому +1

      All you need to do is wipe the flapper off periodically. Remove the adjustment collar and you'll have access to the silcone flapper at the chute.