कैसे कम करें गैस का बिल? | How To Reduce Your PNG Gas Bill?

Поділитися
Вставка
  • Опубліковано 8 вер 2024
  • This video tells about some basic tricks and tips to reduce your PNG gas consumption and ultimately reduce your PNG gas bill.
    Affiliate Links :
    Best Two Burner Gas Stoves
    1. amzn.to/3RxTzp9
    2. amzn.to/3PxKom6
    Best Three Burner Gas Stoves
    1. amzn.to/3EQ3IpK
    2. amzn.to/3ZrNkoQ
    Best Gas Lighters
    1. amzn.to/3Lw4dZS
    2. amzn.to/46hDUyo

КОМЕНТАРІ • 58

  • @anant_arora94
    @anant_arora94 27 днів тому +1

    Best video for saving png bill

  • @srkamde
    @srkamde 11 місяців тому +3

    Very much authentic information. PNG mechanic only enlarge hole but not reduce air inflow. Imported gas stove having provision to shut mixing tube partially or full. I was facing this problem when I reduced air flow flame improved substantially.

  • @ampassionstruck9138
    @ampassionstruck9138 9 місяців тому +2

    Gajab hain aap !! Luv u sir !!!

  • @vishalbaraiya7684
    @vishalbaraiya7684 10 місяців тому +1

    Thank you very much very good information bhai

  • @aadrikaadrik2528
    @aadrikaadrik2528 8 місяців тому +2

    Thank you so much sir

  • @user-gq8pz7su6e
    @user-gq8pz7su6e 7 місяців тому

    aapne bahut hi acche se samjhaya...
    aagar pehle hi png waale chulhe k holes bade kar gaye ho to foil lagana theek hoga?

    • @selffixmasters
      @selffixmasters  7 місяців тому +1

      Yes, heat thoda aur badh jayega jisse gas ko thoda kam chalane ki jarurat padegi

  • @amodyadav4427
    @amodyadav4427 7 місяців тому +1

    Very nice 👍

  • @santoshbijalpatel3933
    @santoshbijalpatel3933 10 місяців тому +1

    Very nice

  • @Amsuvedits
    @Amsuvedits Рік тому +1

    Nice information sir...

  • @santoshbijalpatel3933
    @santoshbijalpatel3933 10 місяців тому +1

    Good job sir 🙏

  • @trueindian4307
    @trueindian4307 3 місяці тому +1

    Sir mene hole bada kerwa liya hai gas ka kya mei bhi ker sakta hoon bill reduced kerne ke liya

  • @rajr9391
    @rajr9391 17 днів тому +1

    Sir ji aapka bill kitna aa rha hai. Kya aap abhi bhi aise hi use kar rhe hain. Main abhi ye tareeka karne jaa rha hoon bina nozzle change kiye. Aap bataaiyen kya ye safe hai, aluminium foil paper se pack karne se. Mera butterfly ka rapid glass top 3 burner gas stove hai

    • @selffixmasters
      @selffixmasters  11 днів тому

      aisa karne se bill kam hua hai aur flame thoda badh gaya hai. aluminium foil ko wire se pack karna hoga, paper jal jayega

    • @rajr9391
      @rajr9391 11 днів тому

      @@selffixmasters maine wire se pack Kiya aluminium foil ko, par Mera flame bahot Kam aa rha hai aur aanch Kam karne pe bujh ja rha hai. It's not working for me

  • @mitang1
    @mitang1 5 місяців тому +2

    Bhai kal yani ki 14 Mar 24 ko aki video dekhi fir aj subah uthke change Kiya system but kargar nahi raha q ki flame bohot low ata hai roti bhi nahi sik paegi😢

    • @selffixmasters
      @selffixmasters  5 місяців тому

      Agar isse koi fark nahi pad raha hai to ek number bada nozzle laga kar dekh lo, usse kaam ban jayega

  • @user-os4qw8ym5v
    @user-os4qw8ym5v Рік тому +1

    Thank you sir

  • @sunderpal5573
    @sunderpal5573 Рік тому +1

    Sir..super

  • @gurcharansingh5534
    @gurcharansingh5534 4 місяці тому +2

    Mera bill bahut aata hai ,mene connection disconnect krne ki application with 2000 Rs barne hai . Hm 2wife husband above 65 and 2din me one units jalta hai

    • @selffixmasters
      @selffixmasters  4 місяці тому

      Ek baar try karke dekh lo isko bhi

    • @NitinSharma-ln8mc
      @NitinSharma-ln8mc Місяць тому

      Mera to gas band bhi rakha to bhi units badhte ja rhe
      Raat bhar 3 unit Jale
      1 month me total 217 units 😢😢

  • @jagmohanlekhadia9887
    @jagmohanlekhadia9887 11 місяців тому +1

    Right mene esa kia hai

  • @rameshnaik3328
    @rameshnaik3328 Рік тому +1

    Hole band karenge to lpg me jo jet lagaya tha o change karane ki jarurat hai ya nahi bata dijiye thanks dhanyavaad.

    • @selffixmasters
      @selffixmasters  Рік тому +1

      Agar sirf side hole band karne se hi gas achche se jalne lagti hai to jet ko change karne ki koi jarurat nahi hai. Lekin agar side hole band karne k baad bhi gas low jal rahi hai to ek number bada jet try kar sakte hain. Maine apne gas stove me jab PNG connect kiya tab sirf side hole band karne se hi burning kafi badh gayi thi isliye maine jet change nahi kiya.

    • @nishantrana1208
      @nishantrana1208 7 місяців тому +3

      Humara shuru se he bill bahot jyada ata hai kitni bar complain ki per koi fayda nahe hua nozzle bada kar dete hai humari gas ka 2 months ka bill 2260/ rupyee aya hai ek bar Mann karta hai connection he katva le per kuch samjh nahe a raha aapne ye jo foil use ki hai ismai koi risk to nahe hai kabhi kisi type ki koi problem to nahe hogi plz reply karke jrur btaye

    • @gurcharansingh5534
      @gurcharansingh5534 4 місяці тому

      Nishant Rana ji , meti bhee same problem hai, company walon ko sb ptah hai pr bataye ge nhi , mene bahut mails ki, Fir Mane disconnect ke lye bola hai ,bola 2000 ruppeS lge ge mene 5500afvance dya hai,same fomula lga ke dekha flame res ho gya but flame blue hona chahida hai

  • @SarfarajSk-mt4ob
    @SarfarajSk-mt4ob Місяць тому

    Kiya bina conversation ke ap chula kaise chalu karoge

  • @ripaljain8506
    @ripaljain8506 11 місяців тому +2

    Png me kitne no.ka jet lagana chahiy

    • @selffixmasters
      @selffixmasters  11 місяців тому

      Agar video me bataye gaye tarike se koi solution nahi nikalta hai to LPG stove me lage jet ka number 1 badha dena chahiye.

  • @rajbaruah6200
    @rajbaruah6200 8 місяців тому +1

    Bil jada Arha he Line gas me to kya number ka pin lagye

    • @selffixmasters
      @selffixmasters  8 місяців тому

      pin itne number ka lagaiye ki gas bartan ki tali se bahar na nikle

  • @SarfarajSk-mt4ob
    @SarfarajSk-mt4ob Місяць тому +1

    Mtar mai jor se thok do mitar fult hune ke baad bill nahi ayega 😅😂

  • @uzergabbur4814
    @uzergabbur4814 5 місяців тому

    9:17

  • @kadeerabbasi6028
    @kadeerabbasi6028 2 місяці тому

    Do hole oxygen ke liye the jo aapne band kar diye. 😅 inhe band karne par flame to jyada hogi par khana late pakega. 😂😂

    • @rajafcp
      @rajafcp 2 місяці тому +1

      Flame jyada hone par khana late pakega kaise??

    • @selffixmasters
      @selffixmasters  2 місяці тому +1

      jo hole high pressure LPG me oxygen k liye bane hote hain wahi hole low pressure PNG me kuch PNG ki leakage karne lagte hain jisse PNG me excess oxygen mix ho jati hai aur total mixture jyada light ho jata hai aur flame thodi kam ho jati hai, mujhe result sahi mile hain, main dusro k result ki guarantee nahi le sakta

    • @kadeerabbasi6028
      @kadeerabbasi6028 2 місяці тому

      @@rajafcp gas+oxygen = perfect burning🔥🔥

    • @kadeerabbasi6028
      @kadeerabbasi6028 2 місяці тому

      @@selffixmasters aapki baat teek hai par khuch chote chote hole aluminum foil me bana sakte kya.

  • @GouravSharma71490
    @GouravSharma71490 5 місяців тому +1

    Koi fark nahi padega mene kar ke dekha hai flame to jyada ho jayge gas fir bhi utani hi lagti hai gas ki total heat same rahti hai

    • @selffixmasters
      @selffixmasters  5 місяців тому

      Mere gas stove me to kafi fark pada tha.

    • @gurcharansingh5534
      @gurcharansingh5534 4 місяці тому

      75% hole band karke dekho, burners sides band kro 75% about thodi air required

  • @onlinebioclassesbybindu
    @onlinebioclassesbybindu 4 місяці тому +1

    Is it safe ?

    • @selffixmasters
      @selffixmasters  4 місяці тому +1

      Depends, how you perform it. I am using this for almost 2 years.

  • @verodanny540
    @verodanny540 10 місяців тому

    Very low

  • @amodyadav4427
    @amodyadav4427 7 місяців тому +1

    Lakin PNG walona Val ko bara kar diya hai