MPPT P&O block logic simulation in PSIM software | Perturb and observe method simulation

Поділитися
Вставка
  • Опубліковано 19 гру 2024

КОМЕНТАРІ • 20

  • @tsengandrew5726
    @tsengandrew5726 Рік тому

    Sir, may I ask which of these voltmeters are for PA, IA, or VA?

  • @Daniel-dj7fh
    @Daniel-dj7fh 2 роки тому

    What are the blocks called used for Va and Ia?
    Thise connected to the multiplier at 2:46?

  • @AxelTevoedjre
    @AxelTevoedjre Рік тому

    Sir, can you tell me please the purpose of the delays blocks and the multiplexer

    • @ahsanmehmood9229
      @ahsanmehmood9229  Рік тому

      Delay block is used where you want to use the present value of signal in the next simulation step/iteration.

  • @hamzaelabd
    @hamzaelabd 3 роки тому

    Sir, can u please explain why did u put 0.1 and -0.1 in the multiplexer

    • @ahsanmehmood9229
      @ahsanmehmood9229  3 роки тому

      These are values of +DeltaD and -DeltaD.
      These values are designers choice and need to be tuned carefully.
      If you increase increase these values, then maximum power tracking time will decrease but oscillations in steady-state will increase and vice versa.

    • @hamzaelabd
      @hamzaelabd 3 роки тому

      @@ahsanmehmood9229Thank u so much but it didnt work out for me because in my case i work on buck-boost converter, can u please give me u email so i can give u the details of my problem with it

    • @ahsanmehmood9229
      @ahsanmehmood9229  3 роки тому

      My email has been given in About section of channel.

  • @CHE-ld7ky
    @CHE-ld7ky 3 роки тому

    My duty summer will continue to add and subtract,so the duty range is changed to 0 or 0.85 how should I do to improve it

    • @ahsanmehmood9229
      @ahsanmehmood9229  3 роки тому

      Yes, it will continue adding and subtracting, that's how it tracks MPP. Do you want a smooth duty-ratio in steady-state?

  • @ivanguadalupeesparza5422
    @ivanguadalupeesparza5422 3 роки тому

    Sir, what Is the valor of Unit Time Delay Block?

    • @ahsanmehmood9229
      @ahsanmehmood9229  3 роки тому +1

      We neither set value of Unit time delay block directly nor there is an option for it.
      The purpose of Unit time delay block is to delay the signal for a unit time. Here "unit time" means Simulation step size (or Time step), which is decided by Simulation control block.
      The value of Time step in this video is 4 micro-seconds as shown at 06:33 minutes. Therefore, we can say value of unit time delay block for this video is 4 micro-seconds, but it changes from simulation to simulation.

  • @ajsarkj3539
    @ajsarkj3539 3 роки тому +1

    Sir, Can you please do a video of same method using Incremental conductance

  • @okbayacine7712
    @okbayacine7712 9 місяців тому

    can u give us a code of boost converter

  • @juliandheoputraprasetya_ft8671
    @juliandheoputraprasetya_ft8671 2 місяці тому

    I'v tried your simulation but my result PA is negative 😢

  • @manuvincent9793
    @manuvincent9793 3 роки тому

    Thanks.