Load Rejection on Generator Transformer|Specialty of Generator Transformer

Поділитися
Вставка
  • Опубліковано 8 вер 2024
  • Generator Transformer or the Transformer directly connected with generator is slightly different from other power Transformer. In this video we will learn the difference, their impact and specific design practices.
    #electricaltechnologyandindustrialpractice,
    #GeneratorTransformer,
    Load Rejection on Generator Transformer,
    Generator Transformer over voltage withstand,
    Specific design of Transformer connected with generator,
    Specialty of Generator Transformer,
    Please like, share, comment and subscribe.
    Thank you watching this video......

КОМЕНТАРІ • 9

  • @laxmileodharadas323
    @laxmileodharadas323 2 роки тому

    Nice

  • @yahiabouchene239
    @yahiabouchene239 Рік тому

    Thanks

  • @sanjeevrana8317
    @sanjeevrana8317 2 роки тому

    Excellent 👌👍 KUDOS. Maje video on short circuit ratios on different generators, transformers. Thanks

  • @chintanvaria2238
    @chintanvaria2238 2 роки тому

    Sir, make videos on transient stability and behavior of system (2 or 3 machines interconnected) under the conditions of various disturbances.

  • @hrushikeshhati2009
    @hrushikeshhati2009 2 роки тому

    Sir its my request please make a video on difference between Vacuum circuit breaker and Vacuum Contactor .

  • @priyaranjanmallick8362
    @priyaranjanmallick8362 2 роки тому

    Supply & Demand - Balance ; How it results into loss of Synchronism in the Power System ; it's all about that only na Sir basically ?
    Please Confirm ; I am one of your subscribers and I have once asked how the amperes & kilowatts drawn by an induction from the supply mains get affected while being operated through VFD at a frequency lower than the rated one which is yet to be answered by you .
    Thank you .

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  2 роки тому +1

      Power=speed x torque. So upto rated frequency if you vary the speed i.e. reduce speed motor will take low power keeping torque constant. However i dont understand your first question

    • @priyaranjanmallick8362
      @priyaranjanmallick8362 2 роки тому

      @@electricaltechnologyandind5335 What about Variable Torque Applications Sir ? In my first question , Supply means Generation & Demand means Load Simply Sir .

  • @sandeepattarde9561
    @sandeepattarde9561 2 роки тому

    Sir, please explain control & relay panel wiring of generator, transformer, if possible.