  • In this guided application exercise we'll wire up and test a three wire magnetic motor starter we introduced in a previous lecture. Additionally, we'll examine this circuit's no/low voltage protection behavior when subjected to a loss and restoration of power and during overload conditions.
    If you wish to replicate this experiment, here is the part list from automation direct:
    BM3RHB-1P6 MMS 1.6A 45MM ROTARY
    CWC07-10-30V18 CONTACTOR 7A 3 N.O. PWR POLES 120VAC COIL N.O. AUX MINI SERIES
    BFC0-22 AUX CONTACT FRONT MOUNT 2 N.O./2 N.C. FOR MULTI MINI CONTACTORS
    RW17-1D3-D012 OVERLOAD RELAY 0.8-1.2A 1 N.O./1 N.C. FOR MULTI MINI CONTACTORS
    GCX3131 PB MUSH 22mm PLAS RED N.C. TWST-REL 40mm HEAD PLAS BEZEL
    GCX3101 PB FLUSH 22mm PLAS RED N.C. MOM 30mm HEAD PLAS BEZEL
    GCX3102 PB FLUSH 22mm PLAS GRN N.O. MOM 30mm HEAD PLAS BEZEL
    GCX3103 PB FLUSH 22mm PLAS YEL N.O. MOM 30mm HEAD PLAS BEZEL
    BIC0 MECHANICAL INTERLOCK FRONT MOUNT FOR MULTI MINI CONTACTORS
    ECC0-R WIRING KIT REVERSING FOR MULTI MINI CONTACTORS
    ___________________
    If you wish to support this project please visit the Patreon page at: / bigbadtech
    ___________________
    Copyright information: Use this lecture. Use it at home, at work, or at school. Put it in a playlist, embed it in a website, share it with your coworkers, family, friends, and enemies. I made this lecture and posted it on UA-cam so users everywhere have free access to this information.
    This being said, this UA-cam channel is meant to be the sole point of distribution for this lecture. Users are not authorized to download it, change it, or charge for access. Don’t even think of downloading it and uploading to your own channel and pretending it’s your own work. Not cool. Use this lecture and let your friends know this free resource exists.
    Use it. Don't steal it. Be cool.
    __________________
    For more FREE online technical training check out the following playlists available at the bigbadtech channel:
    DC Circuit Analysis • DC Circuit Analysis
    Single Phase AC Circuit Analysis • Single Phase AC Circui...
    3 Phase AC Circuit Analysis • 3 Phase AC Circuit Ana...
    Hydraulics • Hydraulics and Electri...
    Pneumatics • Pneumatics
    Motor Control • Motor Control
    Motors and Generators • Motors and Generators
    Motor Drives/Variable Frequency Drives (VFD) • Motor Drives
    Programmable Logic Controllers (PLCs) • Programmable Logic Con...

КОМЕНТАРІ • 9

  • @solaaar3
    @solaaar3 9 місяців тому

    it would have been great if you showed how the reversing kit is working in a bit more details like how it is wired showing the numbers of the contacts. the picture is not clear how it is set up. thanks for the video

  • @johnptc
    @johnptc 4 роки тому +1

    nicely done :)

  • @DxOxDBLxT13
    @DxOxDBLxT13 3 роки тому

    Can you explain why you are using both a manual starter (with a built in over load) and an additional overload? Wouldn't the Manual starter be enough?

    • @bigbadtech
      @bigbadtech  3 роки тому

      Good question. You're correct, either one would serve to protect this system. You'll often see this type of arrangement for 2 reasons: 1) redundant backup in case one element fails 2) the manual motor starter could be servicing not one but several contactors, when a technician opens the manual motor starter everything downstream is de-energized. Elements not serviced by that manual motor starter remain unaffected. This serves as a means of functionally isolating certain elements of a larger system.

  • @sarfrazally6575
    @sarfrazally6575 4 роки тому

    Can you make a video with 110 volt for 110 motor

    • @bigbadtech
      @bigbadtech  4 роки тому

      Stay in touch. I plan to do a series on single phase AC motors (once I finish 3 phase AC motors). Often times 3 phase AC equipment is used to make and break connection to single phase AC motors such that all 3 contacts are wired in series with one another (ie: into L1, out of T1 into L2, out of T2 into L3, out of T3 to motor) such that three series switches simultaneously open and close.

  • @ezariahisgaming2030
    @ezariahisgaming2030 2 роки тому

    Didn’t help that much