3 PHASE LOST NEUTRAL - WHAT HAPPENS - WHY IS EQUIPMENT DAMAGED - A LOOK AT THE THREE PHASE WAVEFORMS

Поділитися
Вставка
  • Опубліковано 31 гру 2024

КОМЕНТАРІ • 105

  • @alinili5569
    @alinili5569 Рік тому +3

    when loosing N On supply side It’s best to switch off the main switch To Avoid damaging single phase Equipments- very helpful video as always thank you Dave

  • @Jim804
    @Jim804 Рік тому +3

    Dave thank you very much. When you make explanations like these with diagrams it’s like I’ve just saved weeks if not months of time trying to work it out for myself or from other experienced electricians trying to explain what’s going on verbally.

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      Thank you for the great feedback. I try my best and its nice to know that its appreciated. Thanks again, Dave.

    • @Jim804
      @Jim804 Рік тому

      @@learnelectrics4402Have you made any video’s on reversed polarity Dave? Again an electrician was trying to explain to me how it works with the example of If the earth becomes live & so on. But I didn’t get it.

  • @CbrigBear87
    @CbrigBear87 Рік тому +9

    You are a gentleman and a scholar, sir. Keep educating! I'm sure many apprentices (and myself ha!) appreciate your lessons/explanations.

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      Thanks, will do. If we don't pass on our skills and knowledge who's going to fix my lights in the future. Thanks for watching. Dave.

  • @Ibrahim-vt2tz
    @Ibrahim-vt2tz Місяць тому +1

    This video was useful as always and very informative. I want to say my gratitude and best regard and thanks to you very knowledgeable man. You’re actually teaching people lots of things that they never learn in colleges especially in fast track courses and people learn nothing there. you never become Electrician in four weeks time unless you are the Moses is so difficult. It’s so difficult. It’s so difficult really to become a Electrician you have to sacrifice a study work very hard and isolate yourself with so many things and it takes time. I will say it takes at least 10 years for somebody to be confident to touch three phase Electric and understand the fault finding character characteristic understand how everything work understand Danger and makes the installation safe according to regulations so I have been studying this videos over the five years and each videos I have been listening maybe 20 or 30 time and every time I learn even extra point so I want to say thank you and show him my best respect in regard for the knowledge you’re having and also sharing with people for freeYou are a very generous man and I wish you the best in life and God bless you.❤

    • @learnelectrics4402
      @learnelectrics4402  Місяць тому

      Thank you for the great feedback. You are doing the right thing, learning a little every few days. This will help to build up your knowledge in a great way. Supplement this with practical activities and you will have a good career. Dave.

  • @michaelcostello6991
    @michaelcostello6991 Рік тому +3

    Great information. We have a few single phase VFD motor controllers in a sub panel that have different power requirements on each phase due to motor ratings so the same could happen here if neutral lost .

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      That's a good point Michael. Thanks for the info and thanks for watching. Dave.

  • @tomm856
    @tomm856 Рік тому +2

    Only seen it once at a public swimming baths where there was a underground cable neutral failure many years ago. Lights glowing very bright and poping and a washing machine motor speed fluctuating wildly

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +2

      Fantastic information. Really useful for our viewers to know. Appreciated and thanks. Dave.

  • @Seve-id8jp
    @Seve-id8jp Рік тому +1

    Really helpful and well explained. Thanks for sharing.

  • @CreepyCrawly-xy1iw
    @CreepyCrawly-xy1iw 7 місяців тому +1

    Perfectly explained. Good job.

  • @user-qi8tv2sj4m
    @user-qi8tv2sj4m Рік тому +1

    Very very good. It has answered a lot of questions

  • @lllCANDYMAANlll
    @lllCANDYMAANlll Рік тому +1

    Great explanation, this was made easy to understand.

  • @aranfairozi1331
    @aranfairozi1331 Рік тому +2

    Love ur channel well done mate

  • @shiamjad
    @shiamjad Рік тому +2

    Another great informative video, please upload more 3 phase videos

  • @tresslerj1985
    @tresslerj1985 3 місяці тому

    Your videos are amazing, also 100.

  • @hvacrwrld1402
    @hvacrwrld1402 Рік тому +1

    Thanks, always explained well.

  • @markobosnjak810
    @markobosnjak810 9 місяців тому

    I , unfortunately, learned it the hard way. Thank you for your lessons sir!

    • @learnelectrics4402
      @learnelectrics4402  9 місяців тому

      Sorry to hear that, put it down as a training session. Thanks for watching. Dave.

  • @Dog-whisperer7494
    @Dog-whisperer7494 Рік тому +1

    I found this very interesting, but it brings up a question?
    If the loss of a neutral on a three phase supply and is dangerous to the end user as well as damaging equipment, then why are new builds starting to have three phase supply’s as standard.? Surely this will put home owners at a higher risk of fire and injury or death.
    Great video as always 👍

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +2

      Now that is an interesting question. Thanks for raising the subject. Dave.

    • @30mAkills
      @30mAkills Рік тому

      Here in India we have 3 and 1/2 core service cables. 1/2 core is the neutral. Means neural size will be half that of phases. This is a cost cutting strategy. Electrically this is ok, but lacks mechanical strength.

    • @TheYohtube
      @TheYohtube Рік тому +1

      Thanks Dave another interesting video in your usual straightforward style.

  • @tadesselijalemmekonnem3855
    @tadesselijalemmekonnem3855 7 місяців тому

    Very smart explanation,this is the types of fault I experienced

  • @michaelsimpson6603
    @michaelsimpson6603 Рік тому +1

    Great information, excellent.

  • @AndrewBaker-z9r
    @AndrewBaker-z9r Рік тому

    Great video, always the best, thanks mate

  • @30mAkills
    @30mAkills Рік тому +8

    We call this phenomenon as Floating Neutral. India.

    • @learnelectrics4402
      @learnelectrics4402  Рік тому

      Yes, that's another useful expression for it. Its a long time since I worked in India, Thanks for contributing. Dave.

    • @davefuntilon5591
      @davefuntilon5591 11 місяців тому

      😊

  • @johnkiran3306
    @johnkiran3306 8 місяців тому

    Hi,
    You have given a case. A 3 phase transformer present which drives 8 houses. Each phase has a fuse before reaching the house, inside house thorough MCBs home appliances are connected. Few appliances are running in few houses. Suddenly a bird hit one of the phase of transformer and it's link blown. In house 3, AC got blown which in running state. House 4 - 3 fans blown 2 running state 1 off state. Seen that neutral wires are blown and inside windings are blown.
    1. Why not all devices blown in other houses?
    2. in house 4, why all devices not impacted?
    3. How does the devices affected which are in off state also ?
    4. Good to hear the detailed analysis report explaining the cause and internal behaviour.
    5. Tell the exact precautions which are needed to handle such situations in future.
    6. How can we test the neutral and earthing fine at transformer and at home

    • @learnelectrics4402
      @learnelectrics4402  7 місяців тому

      This is why we install protective devices, to limit the damage and impact on other devices.
      Have a look at this video on fuses.
      ua-cam.com/video/QuTcXRnugvQ/v-deo.html

  • @anthonyfindlay466
    @anthonyfindlay466 Рік тому

    Well done, Dave anther well explained and important topic your effort and time most appreciated thank you.

    • @learnelectrics4402
      @learnelectrics4402  Рік тому

      Much appreciated feedback Anthony, and thanks for watching. Dave.

  • @raimondtracar8703
    @raimondtracar8703 Рік тому +1

    Something similar happened to me when I connected earth together with neutral, instead to the grounding pole clamp. Had to change the old three fase cable with just a neutral going in to the house, to a new one with added earthing. The main distribution board was outside, on the electric pole, the box was old and a seperate clamp to the ground was missing, so I connected earth to neutral. 2 mysterious weaks of dropping/jumping voltage and some damaged equipment. Thankfully the house didn't burn down and most of the equipment was repaired.

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      Lucky, glad you got it sorted. Thanks for the info, and thanks for watching. Dave.

  • @TitchgamerRG
    @TitchgamerRG Рік тому

    Great vid as always Dave! Thankfully never come across this personally.
    Did discover a over voltage on a certain warehouse once where for some reason the Transformer started out putting 300v per phase though.
    Amazingly only killed a few PCs.

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      Thanks for the feedback Andy. Yes, it doesn't take much to knock a PC over. Catch you soon.

  • @karamathussain3488
    @karamathussain3488 Рік тому

    Thank you for the information very helpful indeed. Please continue doing a great job. Karamat

  • @danielteyehuago1633
    @danielteyehuago1633 Рік тому

    Thanks for sharing it with us

  • @ditlofj3280
    @ditlofj3280 Рік тому

    Great explanation

  • @Roq-stone
    @Roq-stone Рік тому

    Again, well done.

    • @learnelectrics4402
      @learnelectrics4402  Рік тому

      Thank you, appreciated comments and thanks for watching. Dave.

  • @johng.1703
    @johng.1703 Місяць тому

    when you lose the neutral on the supply side you lose the set neutral point so you have a floating neutral, the neutral is normally a centre tap voltage divider with reference to ground, when you lose that you have multiple properties connected to that same neutral and one or more of those properties will also have a connection to another phase, so instead of having a clamped 240v supply you have a floating voltage divider based on resistance that is split between L1 and L2, the lower resistance property gets the higher voltage.
    the voltage will very with the load on each line, the resistance on each line is the load on each line, the higher the resistance the lower the voltage on that line, the lower the resistance (lower the load is) the higher the voltage is.

  • @elc-miscellanea
    @elc-miscellanea Рік тому +1

    Dave, thanks for the insightful video. I have a question about the diagram at 07:37. What happens if N is connected to the local earth system (with an Earth Resistance below 4 ohms) and then downstream separated into N and PE at the distribution board level? This approach is quite common where I'm from. Does this practice mitigate overvoltage issues or exacerbate the risks in case of losing N upstream?

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      I've deliberately left earth of the drawings. In the UK we separate the earth and neutral at the intake position and do not run earth and neutral together in the installation. Without seeing how your wiring systems work, its difficult to say. Hope this helps.

    • @elc-miscellanea
      @elc-miscellanea Рік тому

      @@learnelectrics4402 Dave, thank you for your response. It's interesting to learn about the UK's approach to separating earth and neutral at the intake position. In my country, we typically have (in aerial power line): L1, L2, L3, and PEN - that has the combined function of providing the neutral and protective earth. PEN is grounded at the intake position and at each 2 consecutive poles. At the customer's first distribution board, PEN is joined with the local earth system provided by the custemer (having no more than 4ohms) and then separated into PE and N.

  • @mohammadshirifeshki4018
    @mohammadshirifeshki4018 Рік тому

    Thank you Dave.

  • @pauldow1648
    @pauldow1648 4 місяці тому

    Recently I had 240 v neutral failure probably due to tree branch on service pole . Voltages were not correct at panel. Lights dimmed, some lights blew, some lights when turned on turned other lights on. The Aluminum frame of our screened porch carried, variously, 40 to 70 volts.
    I think our bonded fuse box sent voltages to the screen porch ground, causing my dog to yip when she brushed against the aluminum doorway.
    Best advice if lights (power voltages) act crazy.... Cut power and call power company to repair.
    An electrician does not work on power company side of meter.

    • @learnelectrics4402
      @learnelectrics4402  4 місяці тому

      Great contribution, thanks for watching, Very similar to my Mother's brush with a storm. Dave.

  • @markwienands
    @markwienands Рік тому

    Is there an Over Voltage Protection device at the Mains Distrtbution Board? What are they generally called?

    • @learnelectrics4402
      @learnelectrics4402  Рік тому

      There will always be an over-current device and sometimes a surge protection device (SPD) too.
      Take a look at thois video on SPDs, hopefully it helps.
      ua-cam.com/video/CCZJ0CPOR2U/v-deo.html

  • @AvoElectrical
    @AvoElectrical 10 місяців тому

    exceptional

  • @uaungmyint6387
    @uaungmyint6387 9 місяців тому

    Very Good

  • @b787900
    @b787900 Рік тому

    Thank you for the lesson. I have a question. My house is 3 phase but can be changed to single phase with change over switches, this is because of unstable electricity. Last night after a blackout the incoming voltage was 360v. I thought it was because the neutral was lost. I then changed everything over single phase (all load on 1 line and the “lost” neutral. The voltage went to 200v. Why is it that if the neutral was lost did the single phase work, did the 1 used phase use the other 2 non used phases as a neutral?

    • @learnelectrics4402
      @learnelectrics4402  Рік тому

      Without actually seeing this type of problem as it happens, its difficult to say. But thanks for watching and I hope all is ok now, Dave.

    • @b787900
      @b787900 Рік тому

      ​@@learnelectrics4402not sure as an electrical engineer you actually want to see the wiring in the house. Phases are changed over by wall sockets where all pins are live. You have a total of 9 sockets 3 phases with 3 lines per phase and a neutral line. Africa is scary

  • @DH-tv2yw
    @DH-tv2yw 9 місяців тому

    Would an AFDD provide protection against this fault as they have overvoltage protection? Thinking more in a single phase residential setting where the neutral fault is more likely to be with the DNO?

    • @learnelectrics4402
      @learnelectrics4402  9 місяців тому

      In my opinion, no. Not unless you have loose connections and arcing. With single phase, things will just stop. hope this helps. Dave.

    • @DH-tv2yw
      @DH-tv2yw 9 місяців тому

      Many thanks Dave

  • @saleemqazi8921
    @saleemqazi8921 10 місяців тому

    If the natural is disconnected, will the circuit breaker in the distribution board activate and save the electrical appliances ?

    • @learnelectrics4402
      @learnelectrics4402  10 місяців тому +1

      The circuit just will not work. No current flow. The breaker will not operate unless there is a significant earth fault.

  • @JamesgeraldWard
    @JamesgeraldWard 3 місяці тому

    Brilliant

  • @michaelheraghty9321
    @michaelheraghty9321 7 місяців тому

    top job

  • @uaungmyint6387
    @uaungmyint6387 9 місяців тому

    How to calculate unbalance voltage for 3 phase each phase when lose neutral at unbalance load.
    Because that problem some time happen for people used over head 3 phase 4 wire power line.

    • @learnelectrics4402
      @learnelectrics4402  9 місяців тому

      As the video shows, the voltages can vary quite a lot. It depends just how unbalanced it is, what else is on the circuit etc. Thanks for watching. Dave.

  • @30mAkills
    @30mAkills Рік тому +1

    Useful

  • @vioreltanasa988
    @vioreltanasa988 Рік тому

    When we disconect a thre fase circuit first disonect the fases after neutral when we conect we connect first neutral

    • @learnelectrics4402
      @learnelectrics4402  Рік тому

      Always make sure that you have safely isolated the circuits. Thanks for the input, and thanks for watching. Dave.

  • @stanleytaylor6484
    @stanleytaylor6484 8 місяців тому

    Overvoltage due to a lost neutral is bad news for any equipment. There is more bad news: if the voltage supplied is 230 V rms, then the voltage amplitude swings between -1.41*230=-325 V and +325V, which results in a (momentary) voltage of close to 600V.

  • @brianhewitt8618
    @brianhewitt8618 Рік тому +1

    👌👍

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      As always, thank you Brian. Your support is very welcome. Dave.

  • @ELECTRICLIFE4U
    @ELECTRICLIFE4U Рік тому +1

    ❤👍👍👍👍👍👍

  • @nittaberi
    @nittaberi Рік тому

    Not so important, but no "Kirchoff", correctly it's Kirchhoff. Thanks the video! ✌️😉

    • @learnelectrics4402
      @learnelectrics4402  Рік тому +1

      It is, thanks for putting me right. You guys never let me get away with anything! Your feedback appreciated, thanks. Dave.

  • @okaro6595
    @okaro6595 11 місяців тому

    The electric company covered it? Here they would not, it would be up to your own insurance to cover it.

    • @learnelectrics4402
      @learnelectrics4402  11 місяців тому

      They did in my mother's case, and all her neighbours. Thanks for watching.

    • @learnelectrics4402
      @learnelectrics4402  11 місяців тому

      They did in my mother;s case. And all her neighbours.