How to Measure Voltage, Current and Temperature of a Battery Pack Using the MAXREFDES1277, Part 1
Вставка
- Опубліковано 29 лип 2021
- Sai demonstrates how to quickly test the features of the MAX17852/53 using the MAXREDES1277 and MAX17853EVKIT software. He will then show you how to use this setup to measure the individual cell voltages, pack current, and temperature of a battery pack.
Learn More:
www.maximintegrated.com/en/pr... - Наука та технологія
Current and Temperature ?? when is the next episode?
Communication problem 11x Max 17853x14S + 2 xMax 17852 12S - dual UART + MINIQusb + MAX17841 : Battery Monitoring Device MAX17853 Evaluation Kit
Version 1.0.0
24-05-05 12:18:38 Wakeup initiated
24-05-05 12:18:38 Reading MAX17841 Config2 and Config3
24-05-05 12:18:38 Writing to MAX17841 Config2 and Config3
24-05-05 12:18:38 Config2: Transmit Preambles Mode
24-05-05 12:18:38 Config3: Keep_alive 160us
24-05-05 12:18:38 Writing to MAX17841 Config2: Turn off Preambles Mode
24-05-05 12:18:38 MAX17841 ClearRX
24-05-05 12:18:38 Wakeup successful..
24-05-05 12:18:38 UART device not ready. Use Wakeup and Hello All commands.
24-05-05 12:18:42 Hello All.....
24-05-05 12:18:42 Hello All sent.
24-05-05 12:18:42 Returned Address 0x00
24-05-05 12:18:42 Upstream path
24-05-05 12:18:42 Bottom Address 0x01
24-05-05 12:18:42 Top Address 0x1F
24-05-05 12:18:42 HelloAll Successful
24-05-05 12:18:42 Comm Error. CMD byte read does not match the sent CMD.
24-05-05 12:18:42 Write Index of Slave CMD = 0x03, Read Index of Slave CMD = 0x00
24-05-05 12:18:42 Tx=0xC0 42 03 00 00 58 00. Rx=0x00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
24-05-05 12:18:42 UART device ready.
Please help, I would like to connect to my battery.
24-05-05 12:18:42 Comm Error. CMD byte read does not match the sent CMD. ----- Help me