    This video is in response to some of the common questions that I was getting on my: How To Convert Your Generator To Natural Gas video. In that video I show you how to setup your generator to run on natural gas or propane. This video addresses some issues and answers common questions about the conversion.
    Things I cover this FAQ video:
    Placement of my quick connects.
    What to do if your natural gas supplier stops delivering natural gas.
    Why I didn't buy a propane generator to begin with.
    Does the generator run the same on gasoline as it did before the natural gas conversion?
    Still have questions??? Shoot me an email at: repairgeek365@gmail.com
    Disclaimer:
    The information, demonstration and any content contained in this video is for informational purposes only. The user Repair Geek makes no warranty, express or implied, regarding the effectiveness or safety of the contents of this video. In no way should the contents of the video, including the tools used, be repeated or tried by anyone. Viewers should only seek the help of a trained professional located at a licensed auto repair shop for any fix, modification, alteration, or any change to their vehicle. Repair Geek shall not be liable for any injury, damage, or loss to any person or property that may result from use of the tools, equipment, or any content contained in this video. In addition, there is no way to guarantee that the video is not altered or modified or is not in the final form submitted by Repair Geek and therefore, Repair Geek does not warrant that the video is unaltered or not modified. The links on this video to products are for informational purposes only and in no way are an endorsement of the safety or effectiveness of the particular product. Viewers understand that anything contained in this video or linked to or from this video is the sole responsibility of the viewer and in no way provides an express or implied warranty as to the safety or effectiveness of any linked tool, product, or video. Therefore, viewer agrees to release, waive, and discharge Repair Geek or anyone affiliated with Repair Geek, from any and all liability, claims, demands, actions, and causes of action whatsoever arising out of or related to any loss, damage, or injury, including death, that may be sustained by the viewer, or to any property belonging to viewer, regardless of whether the loss is linked to the use of the contents of this video, or otherwise and regardless of whether such liability arises in tort, contract, strict liability, or otherwise, to the fullest extent allowed by law.
  • Авто та транспорт

КОМЕНТАРІ • 314

  • @RepairGeek
    @RepairGeek  5 років тому +6

    Part 1:
    How To Convert Your Generator To Natural Gas or Propane ua-cam.com/video/nO839Sayci0/v-deo.html
    Product Links:
    Vented Fuel Jugs: amzn.to/2CY5IiT
    Valvoline Natural Gas Motor Oil: amzn.to/2Ql7jnU
    Nash Fuel Kits: amzn.to/2CKjDZF

  • @davidgald3072
    @davidgald3072 2 роки тому +13

    I was a propane carburetion technician for 10 years, had a full shop Dino 4 gas analyzer and converted engines everyday, it's nice to see it is still being done even after new regulations. Looks like you're spot-on that conversion good job.

  • @edreeder9853
    @edreeder9853 4 роки тому +27

    I worked for an lp gas company for years and all their service trucks ran on LP / gasoline and we put well over 200, thousand miles on them, they burn cleaner and didn't give not one minute trouble,
    We actually tore on down once
    ( Ford 360 ) and it looked like new inside, not even a wear ring at top of cylinder, cross hatch was still there,,
    Great way to go on a generator. Last forever..

    • @truebengalsfan
      @truebengalsfan 7 місяців тому

      What engine did those trucks have and are they high maintenance

  • @srobidoux
    @srobidoux Рік тому +2

    For those wondering why run on NG rather than propane: If you intend to be prepared for a lengthy outage, then the amount of propane you can store on site becomes an issue. There may be city or HOA restrictions. Then you have to deal with how to get propane tanks refilled when trucks are held up by the storm and everyone else is lined up to refill at the same time. One other note. Propane tanks get colder as the liquid evaporates. At 7000 watts, you're likely pushing the limit of how many cubic feet per hour you can get from a 20lb tank at zero degrees or below. You may need dual tanks, tank heaters or something larger. If the tank is larger, there are more rules about where it can be situated. If you don't want to worry about that tank running dry during the night, you'll want an auto changeover setup like on an RV. So I'm treating propane as the 3rd option with an inverter up first to cover the initial day, followed by the generator on NG and propane last. I agree about not cutting the frame. I used some angle iron to shift the engine mounts far enough horizontally to make room for the air box.

  • @favoritasdegeorge
    @favoritasdegeorge 4 роки тому +5

    Awesome info thank you very much !! Dealing with this power outage in NJ right now all this is a God's gift to us

  • @robertsummerford6368
    @robertsummerford6368 4 роки тому +3

    Great original build-out video and followup video. I had a few questions watching the first one, found the link to this one and you answered all of them. Thank you!

  • @cesarflores8450
    @cesarflores8450 3 роки тому

    wow never thought about hardened valves/seats for dry fuel. makes total sense. thanks.

  • @epochearth8966
    @epochearth8966 3 роки тому +1

    Thank you so much for such In-Depth information. All my questions were answered - and then some!!
    Now to get off my butt and get working!!
    Thanks again!

  • @dodgeramsport01
    @dodgeramsport01 4 роки тому

    What a lot of people dont understand is that a internal combustion engine will run on anything that is flammable! You did fine my friend!

  • @halfcentury1112
    @halfcentury1112 Рік тому +1

    This is the exact setup I have, only difference is my engine is a Yamaha - I have not had to really test it here in NJ yet - but i start it 2x a year just to make sure it works - Zero problems...Great video

  • @lawrencemiller3829
    @lawrencemiller3829 2 роки тому +1

    Thanks for discussing the valves on gas vs liquid and the possibility of valve conversion and motor oil.

  • @robertclymer6948
    @robertclymer6948 2 роки тому +2

    Thank you my Buckeye brother! Excellent info follow-up! Did not know about the possible valve and seat issues. I am not really that concerned as I hopefully only will run on NG for very short stints when power goes out. Thanks again for sharing. It is very much appreciated. Cheers from Michigan.

  • @wooddawg4868
    @wooddawg4868 4 роки тому +1

    I have the same conversion kit, and like you I like the conversion kit because your generator becomes tri-fuel instead of just propane and liquid gas models.

  • @joeclarke9782
    @joeclarke9782 5 років тому +3

    Good video. Learn something new every day like Natural Gas Motor Oil.

  • @CaptK-py8rq
    @CaptK-py8rq 10 місяців тому

    Thank you for the spot-on information. I'll be converting my Generac GP7000E first chance I get. Last outage we went through 20 plus gallons of gas at $3.88/gallon. At $160 for the conversion kit on amazon, (less the natural gas) I'll break even after 41.2 gallons of gas, plus the converting it over fun...plus, screw the refilling at 4am! You always have informative and useful videos, thanks again!

  • @crackermcwhitey1364
    @crackermcwhitey1364 5 років тому +4

    Thanks for the follow up

  • @copperaudio9664
    @copperaudio9664 4 роки тому +2

    Both videos are very informative - Thanks.

  • @bigtxbullion
    @bigtxbullion 4 роки тому

    Ha! Love that look at 6:20 "whats good!? Howd ya like that!" Dude you are a boss

  • @dave6501
    @dave6501 3 роки тому +3

    Thank-you for the videos they are both very informative and good information. As an electronics guy I'd note that although you are only slightly off of 60Hz this will cause items with clocks to be off or loose time as they run on your system. This coincidently is also why on Gass you noticed the Flickr of the lights it was further off from 60Hz I believe I noticed 57.xHz anyway having power and alternative methods of getting it is great and the main point. Thank-you and good work keep it going :)

    • @Pk3_Garage
      @Pk3_Garage 3 роки тому

      Good point. Three of our clocks speed up, when running on Gen power. From what I can tell, about 1 min. faster each hour on Gen power.

  • @cringecough638
    @cringecough638 2 роки тому

    Thank you for these videos, I'm taking the plunge and doing the same!

  • @villumschroeder1255
    @villumschroeder1255 3 роки тому +1

    Another excellent video. The best part is at 6:17

  • @ForeontheShore
    @ForeontheShore 3 роки тому

    Thanks for the video. I especially enjoyed the mic drop at 6:17.

  • @Bunkysworkshop
    @Bunkysworkshop 5 років тому +1

    Now I wish we had natural gas in my area and propane is very expensive so gas it is. Great video.

    • @loungelizard836
      @loungelizard836 4 роки тому

      You can make your own. And I don't mean by farting into a balloon! Look up Bio-gas generator (methane, i.e. natural gas, or CH4, is a byproduct of anaerobic digestion by bacteria).

  • @brucewilliams6292
    @brucewilliams6292 5 років тому +3

    Well done again.

  • @ericensley2427
    @ericensley2427 3 роки тому

    Awesome video... got to love those "experts"

  • @kwmiked
    @kwmiked 5 років тому +1

    Fair enough, good review

  • @lbamm
    @lbamm 5 років тому +2

    I have done the conversion but I don't use gasoline. It is good to know that I can. I have a powerhorse 7,000 and also have my natural gas connection outside and my breaker box outside.

  • @CeC0DE
    @CeC0DE 2 роки тому +3

    Hey RG, thanks for the video. I've been looking for info on maintinance for LP/propane generators. I understand your point regarding the hardened valve seats you mentioned. But I don't use my generator too often to worry about that, but it sits in storage for extended periods of time and I'm not sure if I need to do anything to make sure it's going to work when I need it. Thanks for the help in advance.!

  • @THERIGGEDONE
    @THERIGGEDONE 4 дні тому

    Superb video, thank you.

  • @edwinmcnew4389
    @edwinmcnew4389 4 роки тому +1

    Great video!

  • @deanrhodenizer938
    @deanrhodenizer938 5 років тому +3

    Two Comments:
    Vacuum leak - Will not affect the fuel/air ratio when running on gasoline as it is external to the carburetor and the vacuum leak sensitive portion of the intake system. That said, it is possible to draw some unfiltered air into the engine through the (now) open natural gas connection so that would be bad.
    So, valve you installed has a purpose.
    Power Back on Detector - I use a device from Relaince (the same folks who made your power meter) called a PowerBack (Utility Power Return Alert). It is battery powered and can be armed when you turn on your backup generator. It monitors the incoming mains and sets off a (disturbingly) loud alarm when the utility power is back on. I expect it is extra loud to be heard over generator noise. You can find it on Amazon by searching for PowerBack.

    • @SomnoNaut
      @SomnoNaut 4 роки тому

      You could also just alligator clip a cheap 120V siren/alarm ($13.50) and when the power comes back it will go off even though the rest of the box is off line power.
      www.amazon.com/Industrial-110dB-MS-190-Alarm-Buzzer/dp/B00IJ678Q6/ref=asc_df_B00IJ678Q6

    • @CSL33
      @CSL33 4 роки тому

      @@SomnoNaut Neither a great nor safe idea and surely against any north american electrical code. (Gauge of any wire must be able to safely take the entire load of the breaker that it's connected to, otherwise it's a fire risk). The PowerBack noted above use an induction coil or similar to connect to the mains. i.e not a direct connection)

  • @deibertmichael
    @deibertmichael 2 роки тому

    Great mechanic.

  • @jerrysmay9303
    @jerrysmay9303 2 роки тому +2

    I know I am 3years late telling you this but with most of your comments. Including valve recession. The only comment I want to add is valve recession is only a problem with cast iron valve seats. Most overhead valve engines used in generators have aluminum heads and already have hardened valve seats.

  • @got2b918
    @got2b918 3 роки тому

    Good info. I don't want to be that 1 in a million. Thanks for responding to "constructive criticism. "

  • @stclairstclair
    @stclairstclair 3 роки тому +1

    I just scored a new-ish 5000w generator from my neighbor because is was leaking gas, I converted it to tri-fuel for the same price
    as carb overhaul parts, I ran it on NG out of my garage line, Oh it's so nice, Never having to haul gas home, No gas going bad each year,
    I don't have to add fuel stabilizer, No gunking carb, I'm just going to stick with NG and propane.

  • @JoelPowell84
    @JoelPowell84 3 роки тому

    This is awesome.

  • @briflemn
    @briflemn 4 роки тому

    I liked your review. I do have a technical question that I've wondered about and haven't found an answer to. That's this; purpose built backup generators such as Generac and Kohler have deeper oil sumps with replaceable oil filters and sometimes oil filters. They are able to run for very extended times without changing the oil. On the other hand, portable generators require frequent oil changes. Have you heard of a way to connect an external oil supply and/or cooler to a portable generators in a semi-fixed position?

    • @RepairGeek
      @RepairGeek  4 роки тому +3

      You can't add a filter to a portable unit. The portable uses a splash lubricated system. So the crankshaft and connecting rod dip into the oil and splash it around inside the motor.
      You can't splash oil through a filter. Engines with filters have oil pumps and have pressure lubrication. They are 2 totally different systems. In any case your oil will stay much cleaner on NG or propane than what they would gasoline.

    • @briflemn
      @briflemn 4 роки тому +1

      @@RepairGeek Kinda what I thought. I couldn't figure a way to keep the proper level of oil in the crankcase for the splash lubrication to work as designed.
      Thanks for the quick reply tho'.

  • @lusrodriguez8769
    @lusrodriguez8769 3 роки тому

    great video

  • @raymondjackson6069
    @raymondjackson6069 3 роки тому +1

    After converting mine, a HF Predator 8750, I started reading about "valve recession", because unless the valves are hardened, the lack of lubrication and cooling from the gasoline, wear and tear will be added at a considerable rate. As for me, I still like the idea, but next time I will get an engine that can be converted. HF's are very basic and hardened valves are not available for it.

  • @bigtxbullion
    @bigtxbullion 4 роки тому +1

    You have a giant shop with lift. Holy cow Im jealous

  • @dawinner777
    @dawinner777 2 роки тому

    I have a dual fuel generator! Both fuels work. The propane is less of a hassle and cleaner burning and better on oil changes and cleanliness of the oil. You don’t have the mess of gasoline and propane is cheaper to run. Fork trucks have been on propane for decades and much safer while working inside a warehouse!

  • @walterlewis6202
    @walterlewis6202 4 роки тому +3

    What size (diameter) natural gas line will I need to run natural gas 35 ft. to my generator 3/8", 1/2", or 3/4"?

  • @9111logic
    @9111logic Рік тому

    I was just about to modify my brand new generator (never used so far) to natural gas but I am concerned about the fact that gas runs the engine very dry, especially valve seats and stems. I must come up with an answer to that or I will face some parts of the engine running hotter than they should. In the old days, we used to have lead in the fuel which would deposit on the valve seats and guides creating a protective coating, with the advent of unleaded they have come up with some substitute additives but with gas, we would non benefit from either of those. I appreciate your comment on this as I have not seen mention of this problem in any of the videos online so far

  • @chrisdeanndavison3626
    @chrisdeanndavison3626 3 роки тому

    Thoughts on being able to operate this INSIDE a well-ventilated garage while on natural gas? A ventless heater up to 35k BTU can be used indoors, so I guess it would depend on the amount of natural gas being burned by your setup.

  • @alandecorte2962
    @alandecorte2962 2 роки тому

    Very helpful, thank you. A question - I have new Champion 7500w Dual Fuel (gasoline/LPG) Portable Generator. I also have natural gas to my home and therefore accessible for use in place of LPG. What modifications must I make to my generator to allow it to run on natural gas, and can I easily switch back and forth between LPG and natural gas if needed? Thanks

  • @snaperoger9588
    @snaperoger9588 4 роки тому +1

    So when You are setting the RPM with your fuel mixture, Should you set that a zero load, full load, or half load? Seems like setting it at half load or higher may give you better performance at those loads.

  • @darrellblair5818
    @darrellblair5818 4 роки тому

    Good video.

  • @eddylee587
    @eddylee587 3 роки тому

    Thanks for the updated video. I viewed your first video at the beginning of the year, 2020. Glad to come across your update on this mod. I purchased a 9K gen and I'm also converting to NG by the fall. Great content. I'm not personally worried about the valve recession issue. Like you said it'll take 1K if hours to notice a run issue. Didn't know of specialized oil for NG or Propane. But, makes sense for autos that are exclusive to this type of fuel supply. I'll definitely change over to that oil once I check the additive package difference's. I wonder if Zinc percentages were increased? Do you use cap covers over your quick connects when stored? Thanks for contributing, Subscribed!

    • @RepairGeek
      @RepairGeek  3 роки тому +1

      I bought some of the oil. The packaging doesn't state anything about high zinc. I haven't had any outages since the oil change. If I get some good run time on the oil I may send it out for analysis. I've got about 8 hours runtime on the NG conversion over 2.5 years. Not a ton but, that's all the outages I've had. Works well, no regrets at all.

    • @eddylee587
      @eddylee587 3 роки тому

      @@RepairGeek Excellent. I've only had to fire up the the gen 2 times sense buying it. I run it 2 times a month for about 10-15 minutes just to keep the fuel moving and fresh. All of course using a fuel stabilizer. I'm slowly reducing adding fuel in prep for NG conversion.
      I imagine you keep the tank empty until gas is need for what ever reason. But, during seasonal changes you will have condensation build up in the tank. What do you use to compensate for moisture within the tank? I'm considering a moisture pack. Large ones like used in shipping containers to reduce or eliminate that issue. We certainly don't want our tanks to rust.
      Suggestions or ideas?
      Thx.

    • @RepairGeek
      @RepairGeek  3 роки тому

      @@eddylee587 I dont do anything. I just drained all the gasoline and drained the carburetor bowl and ignore it. I've had no issues. You could use the generator's fuel tank as a gas can if you wanted just to cut down on moisture but its rather inconvenient. Or just leave the fuel cap loose so air can go in and out.

  • @xcalibre222
    @xcalibre222 4 роки тому

    Nice hose. Where did you get the hose? :) I have a 3/8" ID hose on my 3500 watt generator but thinking about going to a bigger 7000 watt one so will need a 1/2" hose. Thanks for the Vid

  • @HighVoltage1935
    @HighVoltage1935 5 років тому +1

    Actually if you go back to the previous Video where you installed the convertion kit the generator without the kit was surging running on Gas, alone with the kit installed please notice the dryer on low as before it is not surging the meters are holding steady .

    • @RepairGeek
      @RepairGeek  5 років тому +1

      HighVoltage 1200 correct. It was much warmer outside when I shot this video. In the previous video, the generator was running slightly lean due to the colder more dense air during the winter. This video was shot about a week ago.

  • @drewstoy2258
    @drewstoy2258 4 роки тому

    Thoughts on reducing the noise, maybe a different muffler

  • @bobralph5072
    @bobralph5072 3 роки тому

    Pretty dern good information. Dual fuel anything is a good idea in today's world.

  • @BryanTorok
    @BryanTorok 5 років тому +13

    Someone expressed a concern about running out of natural gas and having to return to gasoline. If your natural gas supply is pumped to your house, it won't run out for months or years. Natural gas comes out of the ground under pressure. The gas companies store surplus by pumping it into huge underground reservoirs sufficient for months or years. The distribution systems are controlled electrically, but the gas companies have generators fueled by (wait for it) natural gas. If you get your gas (natural or propane) is delivered by truck, chances are good those trucks are fueled by the same type of gas they are delivering.

    • @RepairGeek
      @RepairGeek  5 років тому +2

      All good info. In my area the majority of the houses are heated by natural gas. Natural gas outages are like you said slim and outages in the winter are almost noon existent. The comments in these videos are full of 'internet engineers'. So, thank you for injecting some common sense.

    • @crossbow3539
      @crossbow3539 5 років тому +2

      Repair Geek I was wondering since your using natural gas if you should use a drop leg at the gas inlet on the generator to catch any sediment that may come through the gas line There should be a drop leg on a nat. Gas furnace and gas water heater on a portable generator I don’t really know. Just to keep crap out of your engine. Good video.

    • @RepairGeek
      @RepairGeek  5 років тому +4

      @@crossbow3539 I have a drip leg inside the wall before the quick connect fitting on the gas line.

    • @Attitudeadjust3r
      @Attitudeadjust3r 5 років тому +6

      As a natural gas company tech I can tell you that not all companies have natural gas fired back up generators. I worked a huge outage in New Mexico years ago and people were without gas for weeks. I know it’s crazy but it’s reality. Second if the power grid goes down and the compressors are not working to maintain pressure in the distribution lines, the gas in the lines will be depleted quickly ( in hours) by furnaces etc running on gen power. Once the existing gas pressure is below a pound or two it will start sucking air into the distribution piping. Once that happens you won’t have gas in the lines again until we purge the air out and replace it with gas once the grid is up again.

    • @JodBronson
      @JodBronson 4 роки тому +2

      Where I live, for the past 16+ years. Anytime we have Power Outage, we ALWAYS have Gas. The Company that supply our Gas, have Gas Generators Back Up.... Hahahahahaha, they are the Gas Company! LOL

  • @igor1467
    @igor1467 5 років тому

    Thank you for the video. Nicely done. I do have a couple of questions about the setup. At 1:30 you are telling about putting a shut off valve that will prevent pulling vacuum into the atmosphere. - Can you please explain what is atmosphere and how does it suck vacuum? what do you mean by vacuum? To my understanding the ball valve could be there to prevent dusty air from entering the engine while running on gasoline as the pressure inside the carburetor is less than atmospheric - a dust cap would be better idea. Another question is why did you mount the regulator upside down? there is a reason why there is an arrow UP showing how it should be mounted. Is there is something other than personal preference that guided you to make that decision. The are tri-fuel generators on the market so people can buy something instead of altering gasoline generators

    • @RepairGeek
      @RepairGeek  5 років тому +2

      You are correct it has the potential for contaminates to enter the governor regulator unless you install a valve or a cap on the auxiliary fuel connection. I'm sure even duct tape would work. I keep my valve closed when the generator is in storage- again to keep contaminates out of the governor regulator. No reason you can't use a cap but, you can't loose a ball valve.
      I have a Garretson KN regulator. Mine does not have an arrow on it. As long as the diaphragm is mounted vertically on mine the orientation does not matter.

    • @igor1467
      @igor1467 5 років тому +1

      @@RepairGeek Duct tape yeah! On Garretson KN 039-122 on the side where prime knob is there are "TOP" letters. I honestly don't know the reason for top, but it might have something to do with gases coming up in the regulator, some element of the valve opening adjusted certain way for gravity, or something simple like you are exposing the two breather holes to rain drops. There was a video with very good explanation how regulator works ua-cam.com/video/CfM6D65MC_w/v-deo.html

  • @maryn4606
    @maryn4606 3 роки тому

    What elbow did you use? To connect the shut off to the convertor?

  • @garyo4456
    @garyo4456 4 роки тому

    So I installed the snorkel kit from US corporation. I planned natural gas to the unit. I’ve drained the gas tank of gas, because I don’t anticipate using gas further. This is my question… Do I simply turn the gas shut off… to Off...(To prevent a vacuum leak?) Thereafter, I assume I’m sad to transition over to natural gas in tune the block adjustment. Thanks to repair geek for the detailed video!!

    • @RepairGeek
      @RepairGeek  4 роки тому +1

      Yes just turn the gasoline valve off.

  • @raymondjackson6069
    @raymondjackson6069 4 роки тому

    Hello, great video, very clear and instructive. When you have a minute, is there a problem, natural gas wise, of running the average house gas furnace and the natural gas fed generator off the same natural gas supply to the home?

    • @RepairGeek
      @RepairGeek  4 роки тому

      That depends on your home. In my situation I have no problem running both but, it's dependant on the size of your main, size of the furnace, layout of your piping, size of your generator, and amount of load in the generator. Basically, you need to make sure your system has enough capacity to run both. There are too many variables for me to make a blanket yes or no answer but, it is possible.

    • @raymondjackson6069
      @raymondjackson6069 4 роки тому

      @@RepairGeek thanks, it doesn't seem to be a common problem, but could be. I will keep aware. Thanks again.

    • @danreise8720
      @danreise8720 3 роки тому

      Does it make a diff if you have 5lb gas meter instead of 2lb..have large meter for pool heater

  • @fredwest5396
    @fredwest5396 4 роки тому +2

    I have converted 3 different gasoline generators from 6k to 86k to 15k watts to natural gas over the years and still can default to gasoline if necessary.

  • @hazcat640
    @hazcat640 5 років тому

    RG, The only question I have is re: gas / propane pressure. Isn't natural gas at your house at a much lower pressure than propane from a bottle? Would I need to put an additional regulator between a propane source and the gas regulator on the genset to account for this?
    Thanks and I am glad I found these gen mod videos. They are very informative and easy to follow.

    • @RepairGeek
      @RepairGeek  5 років тому +2

      Yes you're correct check the other video at about 21:40
      ua-cam.com/video/nO839Sayci0/v-deo.html

    • @hazcat640
      @hazcat640 5 років тому

      Thanks, I missed that some how.

  • @RobMasek
    @RobMasek 5 років тому

    a couple of questions on the long-term stability of that 3d printed adapter.
    1. what is the long term chemical compatibility with NG, Propane, gas/ ethenal, and engine oil?
    2. fdm 3d prints often have certain amounts of porosity. does this system have any way to deal with this?

    • @RepairGeek
      @RepairGeek  5 років тому +1

      Those questions are best directed at Nash Fuel who sells the kit. Since this kit is being sold on a large level I would image they would've done the proper research and engineering to sell this kit.

  • @rickyanonsen1018
    @rickyanonsen1018 2 роки тому

    Hey there, great videos, thank you. I have a pulsar 9500/12000 dual fuel (LP and Gasoline). My generator states that while on LP, the power output drops to 8,650 watts and it still runs the house including the 4 ton Central Air. I can convert it to Natural Gas for about $120 and I have easy access to a Natural Gas line. My Million Dollar Question is..... How much power loss from the original 9500 watts on gasoline will Natural Gas knock it down to? Thank you and keep the great videos coming :)

    • @11ORTIZ11
      @11ORTIZ11 2 роки тому +1

      I just bought a trifuel champion generator and when I was shopping i noticed that there's a 1000 watt difference between gas, propane, and natural gas.

  • @jamesadams8572
    @jamesadams8572 5 років тому

    Is it ok to run the oil u recommended ins generator small engine as it is rated 15w40 ? Seems thick ok for large I
    Engines? And I live in mi where in winter it can get to -20 to -35 below sometimes though rarely. I also have well pump like you. Thanks for the great information and videos. Really well done. Also, manuals on the Honda’s and other small engines call for oil changes like every 24 hours of use or more whats your opinion on that? And do you suggest synthetics for these types If engines ? If so right off the bat or after some breakin? Same question in regards to spark plug change and valve adjustment schedules?
    Thanks again

    • @RepairGeek
      @RepairGeek  5 років тому +1

      I wouldn't stress about the weight of the oil that much. Most small engines require a straight 30 weight oil. A 15w-40 flows like a 15 weight when it's cold and flows like a 40 weight when it's hot. Personally I just use a normal 10w-30 that you can get anywhere. I may switch in the future but, I only have about 2.5 hours on natural gas. If you're truely concerned, just run the oil recommended by the manufacturer.
      I know you can extend out your oil change interval using natural gas. The oil stays much cleaner because the fuel burns much cleaner. The same goes for spark plug changes. What those intervals are I have no idea. It depends on the engine and # of hours etc. The best way to determine if you can use an extended interval is have the used oil analyzed by Blackstone.
      I would probably just check the valve adjustment after about 100 hours or so. I doubt you'd have a valve issue before 1000 hours. You'll know when it needs to be adjusted. The engine will be hard to start or run like crap.

  • @analogblues9606
    @analogblues9606 Рік тому

    I’m running a Predator 9500 on natural gas but I can’t get it to run unless I run it on gasoline for a couple of minutes first. Then if I shut it off while running on natural gas I have to repeat the process again to get it to work again. Any thoughts would be appreciated. Thanks

  • @thewds
    @thewds 4 роки тому

    Great original video and follow up. Sorry if I missed this one, but what amount of natural gas pressure are you getting from your line? Low +/-4 inches of pressure seeme to be a problem with some conversions (LP to NG). Thanks.

    • @RepairGeek
      @RepairGeek  4 роки тому +1

      The regulator on my meter is 6-8” W.C.

    • @thewds
      @thewds 4 роки тому

      @@RepairGeek Thanks! That data will drive my project. Keep up the good work. (The garage looks good with sheetrock). Cheers.

    • @RepairGeek
      @RepairGeek  4 роки тому

      @@thewds haha it's a little more finished now than in this video. Thanks for watching.

  • @gtindetroit
    @gtindetroit 2 роки тому

    Awesome video, im just about to convert my generator, but one question i had is, what would happen if the generator stalls for some reason, say it senses a low oil pressure and stops running, does the gas continue to flow?

    • @RepairGeek
      @RepairGeek  2 роки тому

      The governor regulator on the generator stops flow if the engine stalls.

  • @dirtyd9792
    @dirtyd9792 2 роки тому

    Is there any lack of power when pulling a load with the natural gas versus gasoline ?

  • @mojodrum3215
    @mojodrum3215 Рік тому

    I have a duel fuel champion generator which is gas and propane would this generator come with harden valves and seats because of the propane feature?

  • @ResponseDigitalMedia
    @ResponseDigitalMedia 2 роки тому

    Do you think you could make a dual fuel generator (Gas/LP) run on Natural Gas by using the LP Gas input on the generator instead of inserting at the carb? Using a Natural Gas regulator...

  • @CarlosDelaoGunEngraver
    @CarlosDelaoGunEngraver Рік тому

    what if you want to run propane where would you find the orifice or change it out

  • @ranjzurbano138
    @ranjzurbano138 3 роки тому

    Can't seem to find an NG conversion kit for Powerstroke 7500/6000 generator. Any suggestion?

  • @yuxinsong1544
    @yuxinsong1544 Рік тому

    I tried to use this conversion kit for dry methane (over 85%). The generator could be kicked off but couldn't run continuously. Do you have any suggestions for that? The methane is the main part of natural gas. Thx!

  • @franksausa8812
    @franksausa8812 4 роки тому

    What size gas line did you use?

  • @villumschroeder1255
    @villumschroeder1255 3 роки тому +2

    Valvoline Premium Blue One Solution 9200 SAE 10W-30
    What are the pros and cons of using this oil when
    running on natural gas?
    Anybody used it with a 7000W Champion Inverter? Thanks!

  • @japrogramer
    @japrogramer 2 роки тому

    My generator runs on gas and propane. Can I use a natural gas regulator meant for propane grill conversions so they run on natural gas to feed natural gas into the propane intake of the generator? Since it is made to run on propane I don't think valve recession would be an issue 🤔

  • @ngarber
    @ngarber 4 роки тому +1

    Can you make a video or comment on how to run this generator on LP gas? Is it just another regulator on the LP tank? Thanks.

    • @jon_byler
      @jon_byler 4 роки тому

      Yes. And you probably have to adjust your air fuel ratio like he did at the beginning. I have a $30 Chinese version of this that I have planned to connect to my lawn mower, and I think they have some sort of switch that adjusts the orafice size between propane and natural gas built in.

  • @michaelpotter3055
    @michaelpotter3055 4 роки тому

    How can the same regulator be employed for both natural gas and LP when the pressure of LP, when purchased in a tank, is significantly greater than the 7 in. WC of residential natural gas. Great video BTW.

    • @RepairGeek
      @RepairGeek  4 роки тому +1

      A propane setup needs another regulator on the tank. It's the same regulator that's on your propane grill.

  • @the1spyderryder
    @the1spyderryder 4 роки тому

    What about spraying a light oil into the intake from time to time, wouldnt that help

    • @RepairGeek
      @RepairGeek  4 роки тому +1

      Yes that's basically what a lubricator does. The lubricators put out drops per minute. So time to time probably won't help much unless you want to babysit the generator and spray the intake every 3 to 5 minutes.

  • @douggolde7582
    @douggolde7582 3 роки тому +1

    I'm guessing an occasional run on gasoline would give us those wonderful deposits and mitigate valve recession.

  • @eddiebooten4437
    @eddiebooten4437 Рік тому

    I have a tri fuel generator. Just started it using natural gas. It will run on choke, but when I turn it to run it dies out. Should I let it run on choke for a while, or is something wrong?

  • @michaelcox595
    @michaelcox595 4 роки тому

    FYI if there is a Royal King store near you they carry those gas cans

  • @hazcat640
    @hazcat640 5 років тому

    RG, I keep think about this application because I have a need for a tri-fuel system in my future. I already have a genset and need to convert it.
    Question: Would a two stage regulator like the type used in Oxy/acetylene welding do the trick? It is adjustable to allow for pressure regulation.. What do you think?

    • @RepairGeek
      @RepairGeek  5 років тому +4

      I'm sure that style of regulator should work but, natural gas isn't the place to tell your self, "This should work". Honestly I would only use something designed for this application.
      The regulator that I showed in the video will shut off all gas flow if the engine stalls for some reason. I doubt that style of regulator would do the same thing.
      Will it flow enough natural gas to let the engine run properly?
      It seems like to many safety issues and unknowns just to save $50 to me.

    • @jon_byler
      @jon_byler 4 роки тому +1

      You need to be looking at what the regulator looking thing he attached to the generator is doing. It’s a “demand” regulator that uses intake vacuum to control gas flow into the engine. A pressure regulator won’t be helpful, since it won’t change with demand from the engine intake. Pressure regulator is needed to take high pressure LP gas and drop it to the pressure that the rest of the system works at. Too much pressure, and that demand regulator will no longer work right and you won’t have control of your air/fuel mix. Propane conversion kits tend to come with a simple regulator like on a bbq grill that drops pressure for you at the appliance to 1/2 psi, which is about what natural gas pressure in your house is (anywhere from 1/4 to 1/2 psi in most cases).

  • @davidcloward9518
    @davidcloward9518 4 роки тому

    Excellent videos - thank you. I am trying to prepare for an outage due to an earthquake and thus, I want a tri-fuel conversion kit assuming NG might not be available. I am doing a portable instead of a whole home standby because of that reason and I can stockpile some propane. According to Generac, propane will produce clean power for electronics without an inverter. Otherwise, they said to buy a generator with an inverter/clean power for electronics. I am wondering how far of a hose I can use for natural gas? Did you also try switching from gas and NG to propane? I am looking at a Powermate (generac built) dual fuel propane and gasoline and it will require less conversion to add natural gas. Or I will buy a tri-fuel for a generac generator just because they are so much cheaper than Honda, but better than the rest. Any recommendations?

    • @RepairGeek
      @RepairGeek  4 роки тому

      The size of your hose depends on the size of your generator and the around of load it's under. Larger diameter hose will allow you to run larger units at longer distances from the meter but, the answer to that question is not simple. You need to check the sizing charts listed in the description of the original video.
      To run a generator that was designed to run on propane on natural gas you need to increase the fuel flow. How you go about doing that? That depends on what you're working with. I bought a standard generator and a tri-fuel kit because I knew it would work. Could you get a dual fuel to run on natural gas, sure. But, without making those modifications myself I can't really speak on how to do it.

    • @davidcloward9518
      @davidcloward9518 4 роки тому

      @@RepairGeek Thanks for the quick reply. I will check out the table and also check with the gas contractor. Did you switch from propane and NG without any issues with a tri-fuel? Did you consider whether there is an effect of the quality of the clean electric power of the different generator models or different fuel as claimed by Generac? They said propane was clean power or I needed to buy the Generac models that had their clean power.

    • @RepairGeek
      @RepairGeek  4 роки тому

      @@davidcloward9518 to run propane you need an additional regulator on the bottle to reduce the bottle pressure. Most people use a regulator designed for a propane grill. I've never ran mine on propane just because I don't have a reason to. The rest of the setup is the same. You will have to adjust the fuel bolt on the outlet of the governor regulator each time you want to go from propane to NG. (The energy per cubic foot is different.)
      As far as clean power, mine has a harmonic distortion of less than 6%. Your utility power is less than 5%. An inverter will almost always put out cleaner power than a traditional generator but, with an inverter, your maximum wattage will be much lower for the same money. I think Generac is claiming the power is "cleaner" because the engine runs smoother on alternative fuels than gasoline. That in it self would reduce the spikes in the AC sign-wave and any generator would run smoother on alternative fuel. Generac or not. You can find clean power models for cheaper than what Generac wants for one. If you need more information send me an email: repairgeek365@gmail.com

  • @0066c
    @0066c 2 роки тому

    I bought a tri fuel generator but now I need a pressure regulator. How do I choose the proper regulator?

  • @jaredrrrr5074
    @jaredrrrr5074 Рік тому

    Amsoil makes an oil specifically for small dry fuel engines

  • @prettygirlus9008
    @prettygirlus9008 3 роки тому

    Are you using a 3/4-inch NG hose? How did you decide on the NG hose diameter? I'm using a 10-foot, 3/8-inch i.d. NG hose on my Sportsman TRIGEN9K tri-fuel gen and it works fine .

    • @RepairGeek
      @RepairGeek  3 роки тому +1

      I used 1/2" id. It depends on the length and the size of the generator.

  • @stevehall22
    @stevehall22 3 роки тому

    Does a brand new (never used yet) generator need to run on gas for a few hours first before you start running on nat gas? Or can you immediately start using nat gas. Not sure if engine needs to break in before conversion. Thank you

    • @RepairGeek
      @RepairGeek  3 роки тому

      Yes. I would do the break in on gasoline.

  • @daveharnden3734
    @daveharnden3734 4 роки тому

    When you convert an engine to Nat.Gas, Does the throttle and governor still work?

    • @RepairGeek
      @RepairGeek  4 роки тому

      Yes it works exactly the same.

  • @FrustratedBaboon
    @FrustratedBaboon 4 роки тому

    Why are there no videos on riggs & Stratton 8kW Home Standby Generators ?

  • @EnergySeeker
    @EnergySeeker 5 років тому +1

    if you are running on Propane , i would like to know how much of propane it will take to run the generator for one hour ?

    • @JodBronson
      @JodBronson 4 роки тому +2

      It's all depend on the " Usage ". If you use more " Electric ", then more Propane use. If you use less, then less Propane. The Regulator is designed to " Fluctuate " according to usage. On an average for us, it's about 15lbs for 2-6 Hours during Power Outage.

  • @alteregos8949
    @alteregos8949 4 роки тому

    Gennies are now being sold prebuilt to run on both now. Much more expensive but easier.
    My question is, when you crafted that shim for the airbox. Not everyone has a lathe to crc an adapter, do they sell the adapters online or at a store for particular models so you can remount the airbox or do they sell modified air boxes to fit with the conversion?

    • @RepairGeek
      @RepairGeek  4 роки тому +2

      They don't but, Nash Fuel is aware of my videos and are making revisions to their kits based on what I ran into.
      You could make that spacer using wood if you want too. I had the means and the tools so I used aluminum. Wood will burn just like the plastic airbox would so I wouldn't worry about using a material that would burn.

    • @alteregos8949
      @alteregos8949 4 роки тому

      Thanks for the reply, I too was thinking a wood spacer of sorts or something similar. But you seem to think a lot like I do myself and want it to look like it was made for the machine and has a clean look. I’m a perfectionist too!

    • @jon_byler
      @jon_byler 4 роки тому +1

      @@alteregos8949 Wood, soak it in fuel resistant epoxy to stabilize it.

  • @propellerhead9197
    @propellerhead9197 5 років тому

    Excellent, thanks for the info. Makes things easier for me when I decide to do this. We loose power frequently here and I'm sick of it. Question. Are you running 240V or 120V to the panel..??

    • @5thGenNativeTexan
      @5thGenNativeTexan 4 роки тому +1

      You can see he's plugged into the 220v outlet on the generator, and you can also see that the transfer breaker in the panel is a 220v breaker. Plus he said that he's running a well, which is most likely 220.

  • @tom95521
    @tom95521 11 місяців тому

    Did you split the difference on the different spark plug gaps between gasoline and NG?

    • @RepairGeek
      @RepairGeek  11 місяців тому

      I never touched the plug. It's been fine.

  • @proxybox
    @proxybox 3 роки тому

    Saw your chart for gas sizing but curious what size gas line you're running for your generator? Thanks

    • @RepairGeek
      @RepairGeek  3 роки тому

      1" I'm running a 80,000 BTU garage heater off the same line as the generator. I don't use both at the same time. Could have gotten by with just 3/4" but the price difference was like $.10 a 10ft stick and I'd rather go overkill than chance it when the price difference is that cheap.

    • @proxybox
      @proxybox 3 роки тому

      @@RepairGeek Thanks! I'm contemplating sharing the 3/4" line off my tankless water heater for the same purpose. Since the generator would only be used for outages I think this will be perfect.. I'm fortunate because the 3/4 off the 1 1/4" mainline isn't too far so I think I'm ok but I'll double check with the charts you posted. BTW, your garage is nice with the lift etc. Appreciate your content.

  • @MrSkunks
    @MrSkunks 4 роки тому

    I have a WPro8500. It has an auto choke. Would this system not work?
    Does the choke need to be fully open or closed when on natural gas?

    • @RepairGeek
      @RepairGeek  4 роки тому

      Fully open all the time. Sorry for the late reply I was never notified.

  • @benjaminhardwick8378
    @benjaminhardwick8378 3 роки тому

    Great video - I'm planning to do almost exactly what you did. I can't find any links to where you got the ports/fittings into and out or the house for the gas and electric. Did I miss that?

    • @RepairGeek
      @RepairGeek  3 роки тому

      They are in the description of the original video.

    • @benjaminhardwick8378
      @benjaminhardwick8378 3 роки тому

      @@RepairGeek Hey yes I've clicked on every link but I don't see the white covers that go over your siding to make the connections look like yours. Are those just generic items? I see they resemble those used for mounting lighting to your house but not quite

    • @RepairGeek
      @RepairGeek  3 роки тому

      @@benjaminhardwick8378 oh the panels. I'll get you the link give me some time. Thanks.

    • @benjaminhardwick8378
      @benjaminhardwick8378 3 роки тому

      @@RepairGeek Awesome - thanks!

    • @RepairGeek
      @RepairGeek  3 роки тому

      @@benjaminhardwick8378 amzn.to/3hjo52C
      You will have to cut your own holes to get the wire and the piping through.

  • @poolsinfinite7055
    @poolsinfinite7055 2 місяці тому

    I have a 17500 watt gen, on gasoline works great for my home 4ton Ac, but on NG, wont pick up the Ac, can i add a little bit of gasoline together to compensate the lack of power?

    • @RepairGeek
      @RepairGeek  2 місяці тому

      Nope sorry it doesn't work that way.

  • @elmowyresidence2739
    @elmowyresidence2739 4 роки тому

    I have a question which many sorts of people haven't been able to answer hope someone can help. I am running a small food truck and have two appliances that need to be running off of my generator. Bought a EF2800i Yamaha generator it does the job when its stationary as it is a carburetor engine but as soon as I drive the petrol is obviously jumping around and the appliances are turning off as im assuming that power is being cut out due to the engine type. Spoke to a professional and he recommended a fuel injected petrol generator, spoke to lawnmower repair guy and he reckons that a gas operated generator will eliminate the fuel issue and will allow the appliances to run without turning off. My question is if a gas generator is in motion meaning while im driving will it continue tio run my appliances without then turning off?

  • @gilbertshumway2036
    @gilbertshumway2036 8 місяців тому

    You have not addressed starting the motor with a natural gas regulator. Someone else said a person needs to
    push the little spring on the back of the regulator while trying to start it. Is this true? If so, it's very hard to do if you're trying to pull a cord

  • @tonylongo3412
    @tonylongo3412 Рік тому

    I have a ETQ generator that been working on all 3 types of fuel for years. Now it runs on gasoline but doesn’t run on natural gas. Any ideas?

  • @joeshearer1247
    @joeshearer1247 5 років тому

    With the valve recession thing I don't understand how it could be a big issue since for the exhaust valve it will never get any raw fuel cushioning it in a gas motor either.

    • @RepairGeek
      @RepairGeek  5 років тому +1

      You do not burn 100% of the gasoline in the combustion chamber. That was part of the reason why the catalytic converter invented.

    • @danraby4344
      @danraby4344 5 років тому +1

      When the time comes, you need stylite inserts in the heads. They are harder and for natural gas or propane they will last much longer.

    • @joeshearer1247
      @joeshearer1247 5 років тому

      Repair Geek I understand that point but I still say no unspent gasoline would be considered dry fuel in the exhaust stream in a properly running efficient motor.