Rewiring a SmartDrive motor for hydro/wind generator

Поділитися
Вставка
  • Опубліковано 25 гру 2024

КОМЕНТАРІ • 239

  • @sashapomogaev9327
    @sashapomogaev9327 4 роки тому +3

    Great job! There is a one more option how to cool it down. It's been checked by one guy who ride for 3000km on the "open motor". The idea is to rotate windings powered through sliding contacts, exchanging one side cover of the motor to thrust bearing. As you can see I've removed more than a half of winding (better for temperature) changing winding scheme from 27/30 poles ratio to 12 winded of 27/26 (from 333 x 333 x 333 moved on 120 degrees to 9x9x9) leaving only paired adjacent coils in one phase placing as far as possible in the border of 9 stator teeth for better torque. The electric scheme can be more powerful because of the degree of the distance between paired adjacent coils in 1phase. The more degree is, the more energy efficient torque appears between a diametrically opposed paired adjacent coils. The most efficient angle is 180", where pairs of adjacent coils are situated directly opposite each other (greatest leverage). The most powerful schemes (of most expensive motors)(rotor stator poles combinations) are 16/18 ("ultra motors" ) , 38/42 (the most efficient Japan bldc for flying models "U pro") , 12/14 ,24/26; 36/34 (all these schemes provide 180 disposition between paired adjacent coils belonging to one phase) So you'll empty the middle teeth , but edging teeth of the phase must have a paired adjacent coils, because those linking areas when ends one phase and begins the other must be winded, they are "torque places" .You can remove windings by dropping teeth thereby increasing the angle of lever force in one phase. Running (rotating) windings of the stator , instead of rotor cools by empty and non-empty teeth. These teeth "grab" the air because of their rotation and this system can be easily improved by adding 5w fan directed to open windings. Thus giving a great temperature and power effiency. Every 30 degrees above the design temperature of copper resistivity (20 degrees) is 10% loss of efficiency for the resistance of the wires. For example, 1 kilowatt motor is 100 W losses at 50 degrees. And at temperatures above 90 degrees, the resistance gradient is much higher. I've changed construction bearings (sliding contacts) to industrial ones. I'm working on belt drive one side open motor with wooden pulleys and square woden motor holder with construction studs and bolts with nuts for e-bike like in this video.. ua-cam.com/video/Xk_rqGVw0f0/v-deo.html

  • @EnterTheRealm
    @EnterTheRealm 3 роки тому +2

    I love these motors. They are the best 👌

  • @JahanZeb1976
    @JahanZeb1976 5 років тому +9

    Wonderful. You have provided great tutorial. I am also working on machines.

  • @نصرمراد-ف7ض
    @نصرمراد-ف7ض 2 роки тому +1

    Thank you, you are clever. My question to you is what is the benefit of this connection, why don't you leave it as is? Is this connection better for voltage and braking? Thank you.

    • @stefanstoove9254
      @stefanstoove9254  2 роки тому

      Its useful to reduce the voltage output and increase the maximum current for a low voltage generator.
      Cheers

  • @Stoic-of-Rome
    @Stoic-of-Rome 3 роки тому

    Excellent. Best yet how to for these. Well lit, in focus and referencing diagram. thank you.

  • @TAGUPNBLUE
    @TAGUPNBLUE 7 років тому +12

    They do make rosin core solder low temperature 25 watt iron should do wonderfully The solder should flow right into the copper wire not look like a lump that's what you call good solder joint

  • @Daa253
    @Daa253 3 роки тому +1

    To read amps off a multimeter, put a load on the motor and put the multimeter probes between the motor and the load :)

  • @suparnobolang3685
    @suparnobolang3685 2 роки тому

    terimakasih videonya kak sangat bermanfaat untuk menambah ilmu saya... 👍👍👍

  • @jpmurray01
    @jpmurray01 2 роки тому

    If the place of comsumption is far from the source, it's better to let the generator has is, bring the high 3 phases voltages up to the end. Then convert directly the 3 phases high voltage to DC high voltage with diode bridges. Then use a converter like a Flexmax, Sunnyboy or Chinese high dc voltages MPPT tracking normaly use for solar and it will step down to the voltage you want. Mostly 48 volts.
    That may appear more costly but I'm pretty sure it get better depending how far the production and comsumption are.
    This way, running cable diameter stay small (copper aren't cheap). Power on 3 phases travel well better too.

  • @military_power
    @military_power Рік тому

    bro, can you share a visual about the wiring diagram? I looked at the blog and couldn't find it. respects.

    • @stefanstoove9254
      @stefanstoove9254  Рік тому

      Try www.thebackshed.com/windmill/FPRewire.asp otherwise could generate a shareable link for wiring diagrams

  • @eddieco
    @eddieco 3 роки тому +1

    For those of us NOT in NZ, what US washing machines will use a motor with this kind of stator? I'd love to do this but am not sure how to find a washer that has this...

    • @stefanstoove9254
      @stefanstoove9254  3 роки тому +1

      hmm I'm not sure, maybe try search direct drive washing machines, there's got to be something out there
      Cheers

    • @kevinbrown1629
      @kevinbrown1629 3 роки тому +1

      I work in a scrap yard and see them all the time. I can't tell you what brand they are because we just smash them and move on. I wish I had the time to save them.

    • @eddieco
      @eddieco 3 роки тому

      @@kevinbrown1629 How painful to hear they're being smashed. Ugh, wish you were near me. I'd rescue a bunch of them.

    • @stefanstoove9254
      @stefanstoove9254  3 роки тому +1

      same here, I stripped almost 10 at our recycling place today as we just getting too many of them, I've tried setting them up as small kit sets for people to buy from our shop, which hasn't had much success sadly.
      Cheers

    • @eddieco
      @eddieco 3 роки тому +1

      @@stefanstoove9254 I think those of us who are willing to do this kind of thing are in the rarity.

  • @Luong_Thien_Hung1988
    @Luong_Thien_Hung1988 5 років тому +2

    Thank you. Your video is very cool and useful. My name is Thien Hung, I am in Vietnam. Glad to be friends with you.

  • @منوعاتعربيةوعالمية-ض1ع

    what is the best rewired for low rpm plz ..i have the motor and the turbine but a bad amp ..thank you for this project sir

    • @stefanstoove9254
      @stefanstoove9254  Рік тому

      You need adequate power in (torque and speed of rotor) to generate power out. Low speed input may require step-up gearing to improve amperage output with a rewired stator. Factory winding with 0.6mm diameter copper can only produce a maximum of a few amps before saturation.

  • @Dazdigo
    @Dazdigo 4 роки тому +4

    Might be good to add a common to the Wye wiring and use that to ground everything.

  • @luizantoniobravim8303
    @luizantoniobravim8303 2 роки тому +1

    hello good morning, your projects are fantastic. I'm here from Brazil, watching and making one for myself, I live in a place that has a lot of water. The source you used for this project is how many amps. Thank you if possible.

    • @stefanstoove9254
      @stefanstoove9254  2 роки тому +1

      That's great to try! www.thebackshed.com/windmill/FPRewire.asp
      has various diagrams and explanations of the outputs of each stator configuration.
      Cheers

    • @luizantoniobravim8303
      @luizantoniobravim8303 2 роки тому

      @@stefanstoove9254 Thank you, I like your projects.

    • @stefanstoove9254
      @stefanstoove9254  2 роки тому

      Thanks appreciate the feedback 😃

    • @marcelomartim8761
      @marcelomartim8761 2 роки тому

      @@stefanstoove9254 Hi Stefan, the link isnt working. There is no image too. Just some text (when opened with cache) , thats why we are trying get some information with you and other guys. Thanks !

    • @stefanstoove9254
      @stefanstoove9254  2 роки тому +1

      ​@@marcelomartim8761 Hi not sure why that is - maybe try a VPN to another country? Cheers

  • @messengerofgod2788
    @messengerofgod2788 Рік тому

    I wired a alluminium stator and used crimping connector that works peffectly.

    • @stefanstoove9254
      @stefanstoove9254  Рік тому

      Good idea, make sure to waterproof connections or they may galvanically corrode.

  • @reelMn
    @reelMn 2 роки тому

    Hi again Stefan, I've come to the conclusion that I need to rewire my 6x2C 36 pole stator again - down to 12x1C - I'm still getting too many volts for my 250V charge controller. Have you seen any instructions for this? Thanks again!

  • @jayceeblack5974
    @jayceeblack5974 3 роки тому

    were can we buy this windmill turbine alternator ?

    • @stefanstoove9254
      @stefanstoove9254  3 роки тому

      You can find them in old Fisher and Paykel washing machines. LG also have a variant of these in their direct drive washing machines.
      Alternatively, you may find them second hand online.
      Cheers

  • @marinellahobbyfarm-manongb4891
    @marinellahobbyfarm-manongb4891 3 роки тому

    great vid, Stefan would you know what model or branduses this type smart or direct drive motor in the US. thank you.

    • @stefanstoove9254
      @stefanstoove9254  3 роки тому +1

      Hi - I'm not entirely sure what direct drive washing machines are in the US - maybe try a searching for brushless motors, direct drive washing machine motors.
      LG uses the same design on their direct drive machines.
      Cheers

    • @marinellahobbyfarm-manongb4891
      @marinellahobbyfarm-manongb4891 3 роки тому

      @@stefanstoove9254 thk u, i am trying to build a hydro powered turbine prototype in the US, then if it works I will send it to the Phillipines to power a small remote lot next to a river in the Phillipines.

    • @stefanstoove9254
      @stefanstoove9254  3 роки тому

      @@marinellahobbyfarm-manongb4891 That is really cool to hear - they definitely form a good foundation for a lot of generator setups.
      Thanks

    • @Peace-r5b
      @Peace-r5b 2 роки тому

      Stefan how much to buy one from you

  • @engineerkohat
    @engineerkohat 5 років тому +4

    بہت ہی اچھا ٹیوٹوریل اپلوڈ کیا ہے جناب۔ فری انرجی تقریبا ہر بندے کی ضرورت ہے۔ فری انرجی ہر گھ کی ضرورت ہے۔ میرے چینل پر 160 کلو واٹ فری انرجی جنیریٹر کی ویڈیو موجود ہے۔ ہر بندہ سپورٹ کرے۔ شکریہ۔

  • @tomeks666
    @tomeks666 2 роки тому

    What if instead of rewiring the stator just use the original wiring, rectify whatever voltage it makes with 6 diode bridge and feed PC style SMPS power supply from it? I did not try that, but some say these power supplies will start with on DC, any voltage 90-250V. SMPS should should be possible to adjust to 14volts suitable for charging a battery bank.

    • @stefanstoove9254
      @stefanstoove9254  Рік тому

      These stators can go well above 1000VAC and higher rectified DC when an unregulated turbine drives the rotor. Would suggest having accurate load control and appropriate safety systems in place if you were to wire in to a DC system on factory winding.

  • @axnbjsbdudbydvydubu9355
    @axnbjsbdudbydvydubu9355 6 років тому +1

    you should do a step by step video. Very cool project. should the stator poles be of opposite directions ?

  • @volkansuner2621
    @volkansuner2621 4 роки тому

    So beautiful. I will have a few questions. DC generating current or AC current? How many Volts of power does it produce in how many cycles?

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Thanks, the motor itself produces 3 phase alternating current, which can be rectified to DC through a 3 phase full bridge rectifier.
      Voltage is around 12 to 24V after rewired in this scheme at a couple hundred RPM. Cheers

    • @pehlivan4935
      @pehlivan4935 3 роки тому

      Slm volkan 05353469350 konuşalım

  • @japerez1968
    @japerez1968 4 роки тому

    When rewiring, why not connecting the centers of the different stars? Doing this would create a short circuit or would improve electrical stability?

    • @japerez1968
      @japerez1968 4 роки тому

      @@stefanstoove9254 I mean interconnecting the centers of different stars. Can this be done? Or would it be dangerous?

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Hi there!
      I'm not sure, the motors are originally wound in star, with the 3 phase ends interconnecting at a main termination point.
      Cheers

  • @Matt-bd2or
    @Matt-bd2or 4 роки тому

    Do you happen to know where I can get a full diagram of wiring it in 7 phase 1x6c? I did find a partial pic on The Bach Shed, but it only show the 1st step.

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      I've never actually done the 7 phase conversion before, I've heard it's good but haven't had much time to look into it The most you can find is on the back shed website.
      Sounds like 6 coils in series, so I'm assuming it will be similarly wound but every 7 steps for the 7 wires on the 42 pole stator?
      The star termination point will have the 7 ends joined together.
      Thanks

    • @daisy5644
      @daisy5644 4 роки тому

      Wow, you really helped me out, I truly appreciate it! I just joined the back shed, what an awesome site. Thanks again.

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому +1

      Thanks and good luck! I'll try my best to help if you have any questions :)

  • @yasinerol3799
    @yasinerol3799 5 років тому +1

    Hello Is it possible to provide the coil winding diagram of the 48 volt 250 watt hub motor?

  • @brahyanpalacio8436
    @brahyanpalacio8436 4 роки тому

    Buen vídeo, te pregunto que diferencia hay en trabajar con la configuración original y hacerlo con la configuración que realizo?

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому +1

      La nueva configuración reduce el voltaje y aumenta la salida de corriente (al poner más bobinas en paralelo),
      Esto lo hace más adecuado para un sistema de 12V / 24V.
      Gracias,
      Stefan

  • @wolfgangbottcher1338
    @wolfgangbottcher1338 5 років тому +1

    Abwarten die Idee ist Super

  • @dachez69
    @dachez69 3 роки тому

    Would it work as a low voltage motor as well?

    • @stefanstoove9254
      @stefanstoove9254  3 роки тому

      Yep, as there are a lot of windings, they need to be rewound with thicker wire or with all coils in parallel - 48v at 1000rpm from my experience.
      Any quicker, and the switching frequency of the controller will begin to limit the maximum speed.
      Cheers

  • @منوعاتعربيةوعالمية-ض1ع

    good morning sir 36 poles 6×2C can give us good amp at a mid wind >>> thank you

  • @epianguiano7880
    @epianguiano7880 4 роки тому

    Hello, thanks for the video. Can you tell me what kind of rectifiers you used for this generator? like what part number or such. thanks

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      3 phase bridge rectifier from Aliexpress.
      Or you can create a bridge rectifier from large diodes, but they do need some kind of heat sink if you run a lot of amps through them.
      Cheers

  • @closertothetruth9209
    @closertothetruth9209 7 років тому +2

    2 coils per phase seems the best for low voltage systems with the 42 pole stator, theyre not a huge power house but good for low rpm output.
    i like the samsung stator also

    • @closertothetruth9209
      @closertothetruth9209 7 років тому +1

      yeh i learnt the same , i split the stator in half then thirds then quarters then into 7. but you need some good rpms to see good amps.
      have you looked into diy axial flux pmas like Hugh Piggotts

    • @jregamey
      @jregamey 2 роки тому

      So 3 phase (3 groups) which have total 6 poles?

  • @Sahil-vn1tk
    @Sahil-vn1tk 4 роки тому

    Does this configuration require to rearrange the magnetic poles on rotor???

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Hi, the rotor stays the same unless you use a different number of poles stator. As this is only changing coils from series to parallel, there is no need to change the rotor. Cheers

  • @maxhewitt4381
    @maxhewitt4381 4 роки тому

    Im having trouble finding a fisher and paykel smart drive machine anywhere near me. If i were to order the parts individually to make this generator from scratch what would all the parts i need be called? Advice would be much appreciated. Cheers.

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Hi there,
      In New Zealand, there are often plenty of washing machines at the tip or recycling stations which you can take these motors from. I was lucky to have a community based shop called CREW, they have helped me source many of these Smartdrive motors to use in my projects.
      If you are overseas, you might be able to find them listed online, but will be a cost as shipments and business come into it.
      Thanks and Good luck!

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Most important parts would be:
      - The motor - also known as, Gentle Annie Motor, SmartDrive Motor, F & P motor, Fisher and Paykel motor, BLDC washing machine motor, etc.
      - Stator mounting flanges/plates - helps secure motor to drum.
      - The rotor - two versions, one for older 42 pole motor and one for newer 36 pole motor.
      - The shaft (25mm Dia. stainless, splined at each end: 2 versions - 1 with external threaded ends and the other with internal threaded ends which is newer version.)
      - The thin shaft nut (to retain bearings)
      - Two bearings (6005RS) , sealed are recommended in weather conditions.
      The motor mount can be built manually or taken out of the washer drum as you might have seen.
      Many thanks and Good Luck!

  • @MjrTraumaVictim
    @MjrTraumaVictim 4 роки тому

    Do you know of the make and model you got the bdc motor from? i have a river running past my home with only 20 mtrs to my supply and want to do something like this to drop my useage
    whilst offgrid in a forest

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Yes - it is a Fisher and Paykel 'SmartDrive' motor.
      This is a 0.6mm copper wound 42 pole stator.
      Commonly known as F&P motor, BLDC Washing Machine Motor, Gentle Annie Motor and SmartDrive motor.
      Hope this helps, cheers and good luck!

  • @nikrous5996
    @nikrous5996 5 років тому +1

    Firstly thanks. I have three questions, 1. The winding of the 42 coils is on the same direction?
    I mean are all of them clockwise? 2. The winding system of the 42 poles is the stator sysem?
    3 At the 3.44 to 3.45 second when you insert the cover it has all around a intrinsic metal cover (if am i not wrong) is this a magnet and does this consist the rotor system? In case the anwer is yes just because is enough difficult to find a such circular magnet , Is it possible to replace it with a sery of accessive linear magnet in the interior of the cover? .

    • @nikrous5996
      @nikrous5996 5 років тому

      @@stefanstoove9254 Dear Stefan thanks from my heart you are really superbe.

    • @babic.s2496
      @babic.s2496 4 роки тому

      @@stefanstoove9254 hello if i did the pole by which you connected why i have no effect, does it have what role 42 and 36 coils play and what role does diode play

  • @wolfgangboettcher3126
    @wolfgangboettcher3126 5 років тому

    Auch eine Idee,hab ich gar nicht nachgedacht . Danke

  • @ИМЙАСЕРГЕЙ
    @ИМЙАСЕРГЕЙ 4 роки тому +2

    😉растешь чувак в моих глазах .удачи в делах тебе

  • @shanewalker6948
    @shanewalker6948 5 років тому +1

    How ma power does it put out and at what rpm

  • @radipula
    @radipula 4 роки тому

    My 36 pole Smart Drive was wound with aluminium wire. What now? Must I march it to the dustbin Stefan?

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Hi there!
      The aluminium stators are definitely more difficult to work with as they do not solder with regular lead-free or leaded solder.
      I heard of an idea to use crimp connectors to clamp rewired stator connections together?
      Another method could be to strip off aluminium wire and replace with thick stranded enameled copper wire, (this skips the rewiring process but takes a long time to strip and rewind stator).
      Cheers and good luck!

  • @dugagjindervishaj3440
    @dugagjindervishaj3440 6 років тому +1

    can you guy's explain why you rewiring this motors?

  • @marcosbomfim4691
    @marcosbomfim4691 5 років тому

    friend can generate how many amps? I want to do to put helices

  • @mauro659
    @mauro659 5 років тому

    Hi, I saw some of his videos about the wiring of the stators, I visited the F&P link and I got a little lost and disoriented, not being an electricity expert, I kindly wanted to ask you,
    not having RPM problems, which wiring indicated by F&P should I use to have the maximum amps? Thanks.

    • @mauro659
      @mauro659 5 років тому

      @@stefanstoove9254 SALVE, THANKS FOR THE ANSWER, AS I SAYED IN MY PRESENT E-MAIL I ARE NOT VERY COMPETENT IN THIS FIELD, I WOULD BE VERY NICE IF YOU SEND ME A SCHEME OF HOW TO CONNECT THE STATOR REELS TO HAVE THE MAXIMUM OF THE HA, CONSIDERING ONE 36 POLE STATOR. ILMIO E-MAIL ADDRESS IS THE FOLLOWING: p.pianelli@libero.it.
      WAITING FOR YOUR GOODNESS REPLY YOUR GREETING.

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому +1

      Hi!
      Maximum current can be achieved by putting all the coils in parallel in each phase.
      Another method is to completely strip wire and use a much thicker copper stranded wire to wind the stator, but this process is very time consuming.
      Cheers

  • @elnitido07
    @elnitido07 4 роки тому

    hello how are you I hope you are available today 2020 I need to know if it is metal or plastic where the coil wire is wrapped?

    • @elnitido07
      @elnitido07 4 роки тому

      ook thank you very much I have not found that washing machine motor but I will do it in acrylic then put metal bars on it and likewise coat it with acrylic thanks again from the Dominican Republic I will review the video very well to know the turns of wire and all the truth I do not know much English but google helps me

    • @elnitido07
      @elnitido07 4 роки тому

      if i will see you
      how many turns does each coil have and what number of wire did you use?

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Hi! The coils on this stator are fully insulated with plastic and have an iron laminated core like most stators.
      Cheers.

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      That is all good :)
      Good luck with your project!
      Cheers

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      On the first stator I rewound completely, I used 8 strands of 0.8mm copper, wound in 2P x 6C star. This gives a much lower voltage at a high current (typical for higher speed low voltage BLDC motors).
      Cheers

  • @filipeteo2342
    @filipeteo2342 6 місяців тому

    In this closing, it becomes lighter to run? Sorry for the question, I don't understand your language 100%.

  • @subashkumarchary253
    @subashkumarchary253 4 роки тому

    Good morning sir I have the LG direct drive motor 36pole stator aluminium winding is their. I want to make the air wind generator.how to do the generator winding please help me urgent please show me the diagram pic

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      36 pole motor wiring can be found on thebackshed.com under Fisher and paykel motor rewiring.
      Generally, aluminium is not suitable for soldering, so a copper stator is better, but I have heard of using crimp terminals to do wiring connections.
      Cheers.

    • @subashkumarchary253
      @subashkumarchary253 4 роки тому

      @@stefanstoove9254 sir thebackshed.com is not working the site

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      www.thebackshed.com/Windmill/FPRewire.asp
      Sorry hopefully that should work now, has lots of diagrams and useful info on this page. Cheers

  •  7 років тому

    help me friend with my garador he has 36 coil, and the detail is that the wire is not copper but aluminum. I want to make the same connection I bought connectors so I did not have to solder.

  • @lostspace5811
    @lostspace5811 4 роки тому

    Hi so why is it necessary to rewire it?

    • @lostspace5811
      @lostspace5811 4 роки тому

      Is it for voltage?

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому +1

      Hey there! Yes, rewiring does reduce the voltage output and increases maximum current. This makes it more suitable for 12/24V systems.
      Cheers.

  • @Bhimaraya1267
    @Bhimaraya1267 4 роки тому

    Where is get this part and how much cost I will try to best

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Hi!
      This is a Fisher and Payekl 'SmartDrive' motor.
      Very common in New Zealand but might be able to find some overseas on Ebay possibly?
      It is a type of BLDC motor.
      Cheers

  • @Armyforever-xi8ou
    @Armyforever-xi8ou 6 років тому +1

    Pls make diagram for clear understanding

    • @dalaylamasana
      @dalaylamasana 5 років тому

      www.thebackshed.com/windmill/FPRewire.asp

  • @robertlong2531
    @robertlong2531 3 роки тому

    If you only want DC out, how about avoiding having to convert to single phase by simply rectifying the 3 phase output. You only need 6 diodes to do it (Google 3 phase rectifier).

  • @ErCanEverything
    @ErCanEverything 3 роки тому

    Nice work

  • @paolopianelli
    @paolopianelli 5 років тому

    Salve , grazie per la risposta, cosa mi consiglia di quello che c'è in commercio per quando riguarda la mia esigenza.Grazie.

  • @geral4variedades8
    @geral4variedades8 6 місяців тому

    parabéns valeu a explicação...

  • @paolopianelli
    @paolopianelli 5 років тому

    salve, ottimo, una domanda, potrebbe caricare tre batteria da accumulo da 12 volt con un totale di 400 ampere., Grazie.

    • @paolopianelli5301
      @paolopianelli5301 5 років тому

      @@stefanstoove9254 salve, grazie per la risposta, mi potrebbe gentilmente dire lo spessore del filo da utilizzare e quanti metri dovrei utilizzare per ogni bobina. Grazie

  • @mhdsajeerpm7834
    @mhdsajeerpm7834 4 роки тому

    Please help me to make generator for VAWT at low rpm and low starting torque. using direct drive motor

    • @mhdsajeerpm7834
      @mhdsajeerpm7834 4 роки тому

      @@stefanstoove9254 Thank you For your recommend stefan stoove

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Hello! The factory motor produces around 12/24V at low RPM. This is at a low current, but could be good for a small easy VAWT.
      The best method would be for a larger VAWT, to use step up gearing on a rewired motor (so that it is spinning faster) to produce more power.
      Cheers.

  • @nicoslider
    @nicoslider 5 років тому +1

    from where is coming this 42 legs motor? thanks

  • @muhammadmohib971
    @muhammadmohib971 Рік тому

    Very nice 👍

  • @ferdinandpredi3301
    @ferdinandpredi3301 5 років тому +3

    Thanks ;great help!

  • @homozilla3515
    @homozilla3515 5 років тому +2

    So good !

  • @ruturajtambe2664
    @ruturajtambe2664 4 роки тому

    Why do we need to rewire the motor?

    • @FullyGored
      @FullyGored 4 роки тому

      Because they way its wired up, it uses power to create the stator to spin. This rewire is using the spinning stator to generate power!

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Rewiring the motor by putting more coils in parallel reduces the voltage to make it more suitable for a 12 - 24V generator.
      The quicker the motor spins, the more voltage on the output.
      Therefore, for higher RPM applications such as high speed pelton water turbines, more coils should be put in parallel to reduce voltage, and increase current output.
      Once rectified to DC through a 3 phase full bridge rectifier, this can be used to charge 12 - 24 - 48V deep cycle batteries.
      Hope this helps and good luck!
      Thanks

  • @ltv2390
    @ltv2390 4 роки тому

    Nice experiment

  • @alperyldz4846
    @alperyldz4846 5 років тому

    Bu şekilde yaparak voltajı mı yükselttiniz amperimi bi açıklama yaparmısınız teşekkür ederim

  • @karinavelasco2288
    @karinavelasco2288 5 років тому

    Donde puedo encontrar éste generador y cuánto cuesta, gracias por sus video estoy en Colombia,

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      ¡Hola!
      En Nueva Zelanda, hay muchos motores de lavadora viejos en las estaciones de reciclaje.
      Tal vez intente eBay? Sin embargo, probablemente costará mucho más.
      Gracias

  • @advanceg2116
    @advanceg2116 6 років тому +3

    I was thinking that an easier route to go would be put each phase through a Full wave bridge rectifier then merge the 3 phases once converted to single phase in parallel providing higher amp.

    • @Dynasty125
      @Dynasty125 6 років тому

      My exact idea after watching this. Pretty sure by doing what was done you just lost 1/3 the output

    • @hubrisnaut
      @hubrisnaut 4 роки тому +1

      Seems like a good idea. Any links to someone doing it? There are many videos about "rewiring" these motors. Your idea seems simpler and could produce more power...

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому +2

      Sounds similar to a Delta connection? But maybe each phase is isolated from another. It might affect output at low RPM, as you are pulling power from a single coil set rather than through 2. Delta would achieve similar results, but voltage will be less due to voltage being from a single phase.
      Could be worthwhile investigating
      Cheers

    • @hubrisnaut
      @hubrisnaut 4 роки тому +1

      @@stefanstoove9254 I am going to subscribe. Look forward to your investigation of this possibility. Have a great day.

  • @borgessolar285
    @borgessolar285 4 роки тому +2

    Ligações de estrela para delta e melhor e um controlador mppt verás a diferença👍👍👍

  • @dominicnobel8709
    @dominicnobel8709 4 роки тому

    2c means...?

  • @ميميميمو-ق4ف
    @ميميميمو-ق4ف 5 років тому

    ملاحظة ممكن ان نولد كهربا 220vمستمر بهزا الموتور وهو يوجد ببعض الإساءات بحال وجدنا شيء وبركه بسرعة معينة او على إسقاط ماء مثل شلال نضع له فراشات دفع ممكن توليد كهرباء ولن مستمر وليس متردد ب بليب

  • @rajgj7041
    @rajgj7041 5 років тому +1

    I wanna use it as a motor ,(for ebike) with how much voltage i shuld run it after your modifications ?

    • @rajgj7041
      @rajgj7041 5 років тому

      @@stefanstoove9254 how can i wire the motor in delta ?!

    • @rajgj7041
      @rajgj7041 5 років тому

      @@stefanstoove9254you told me that in delta i will get a better performance, but will it be harder for the motor ( will he overheat or sth ) ?

    • @rajgj7041
      @rajgj7041 5 років тому +1

      @@stefanstoove9254 thanks alot for the help 🙂

    • @Tera4m
      @Tera4m 4 роки тому

      The Mechanic #tonystark

  • @GeorgeKingakaDruidKing
    @GeorgeKingakaDruidKing 4 роки тому

    Why on earth would one go to the risk and trouble to rewire an ac producting motor used as a generator to lower its voltage and increase amperage whit a simple cheap step down transformer does this so well? If issue is frequency because most transforms are 50/60 Hz magnetic cores. Just wind your on on a switching a power-supply, etc toraroid core.

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому +1

      It is safer and likely more efficient method of bringing voltage down and increasing current for 12/24V systems.
      In some cases, yes, it would be logical to leave as high voltage 3 phase AC if you are transmitting power over a longer distance so as to reduce voltage drop. This should only be done by someone experienced.
      Its fairly straightforward to rewire once you understand the fundamental workings of the BLDC motor.
      Thanks,
      Stefan

  • @pugalstech
    @pugalstech 4 роки тому

    Nice vedio and very useful

  • @blackmusiccover6847
    @blackmusiccover6847 5 років тому +1

    👏👏👏 muito bom

  • @51-FS
    @51-FS 6 років тому +1

    i dont think this will fix my washer

  • @Laurentius_Studio
    @Laurentius_Studio 4 роки тому

    My Gosh!
    Ya need to do a better job on the soldering buddy.
    Need to add flux to the wire(s) & Have a proper type of solder as well!
    There are ways of configuring the phases.
    Not sure if you knew of the simple rule
    Wye produces good volts while amps aren't that great
    Delta produces set volts while amps are AWESOME
    Godspeed

  • @sandipdas9411
    @sandipdas9411 3 роки тому

    I am from INDIA 🇮🇳 haw to banifet in paralal. Voltage dawn🤔 app 🤯🤯 amper dawn🤔 app. Plis replly.

  • @joymaker5
    @joymaker5 4 роки тому +1

    I saw the video well
    I am a rate my video
    Thank you beginner UA-camr
    Please

  • @Zamot1100
    @Zamot1100 4 роки тому

    In wirig diagram dide wrong polarity .

  • @gurutv6241
    @gurutv6241 4 роки тому

    Genera 110 v ? O 12 v ?

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      For 12/24V low rpm systems once rectified to DC (maybe 200 to 300rpm on input).
      Thanks,
      Stefan

  • @Zamot1100
    @Zamot1100 4 роки тому

    "Wind generator" have a korekt wiring diagram

  • @khaliffoster3777
    @khaliffoster3777 2 роки тому

    Can add closed caption.

  • @elcreador6675
    @elcreador6675 5 років тому +2

    Excelente 🇩🇴🇩🇴🌎

  • @nguyeninhminh2696
    @nguyeninhminh2696 4 роки тому

    24v???ampe.

    • @stefanstoove9254
      @stefanstoove9254  4 роки тому

      Amps at 24V in this configuration would be somewhere between 10 and 15A peak.
      Cheers.

  • @TAGUPNBLUE
    @TAGUPNBLUE 7 років тому

    Y NOT USE 63 VOLTS CHANGE TO DC WITH CAPS THIS DRIVE DOWN AMPS AND A CHARGING CONTROLLER.600V ON DOWN IN PUT. OUT PUT 12/24/48 VOLTS OUT DC. COILS WILL RUN COLDER

  • @Zamot1100
    @Zamot1100 4 роки тому

    File name; Wind generator with LG ddm 0001 -see my modfy generator

  • @MrOprawca1978
    @MrOprawca1978 4 роки тому

    Generatory napedzane wiatrakiem czy kolem wodnym, robione z bylych silnikow, maja o wiele za niskie obroty, wiec by pracowal on sprawniej, cewki musza byc polaczone szeregowo, by generator dawal jak najwyzsze napiecie, wtedy prad bedzie maly, a im jest mniejszy, tym slabiej beda sie cewki grzac, a to jest duzy mankament tych konstrukcji. No i slabe, ferrytowe magnesy w rotorze tego silnika powinny byc zamienione na porzadne, silne magnesy neodymowe, wtedy to dopiero ma jakis sens. Niemniej jednak, z takiego bylego silnika od pralki najwyzej, co da sie osiagnac, to gora 300W, choc te silniki sa wolnobrotowe, to i tak, by pracowal sprawnie, musi obracac sie z obrotami okolo 1000 rpm, a smiglo powietrzne da gora 1/3 tej wartosci.
    Generators driven by a windmill or a water wheel, made of former engines, have a much too low speed, so for it to work more efficiently, the coils must be connected in series, so that the generator gives the highest voltage, then the current will be small, and the smaller it is, the weaker the coils will heat up, and this is a big drawback of these structures. And the weak, ferrite magnets in the rotor of this motor should be replaced with decent, strong neodymium magnets, then it makes sense. Nevertheless, from such a former washing machine motor, the highest that can be achieved is up to 300W, although these motors are slow-running, in order to work efficiently, they must rotate at about 1000 rpm, and the air propeller will give up 1 / 3 of this value.

  • @studio4598
    @studio4598 4 роки тому +1

    Good ❤️🌹

  • @kavajamusic5411
    @kavajamusic5411 4 роки тому

    from the river, you can get free energy, forever

  • @TAGUPNBLUE
    @TAGUPNBLUE 7 років тому +3

    CRAPPY SOLIDER JOINTS TO COLD

  • @hasan-qe3vs
    @hasan-qe3vs 3 роки тому

    ممتاز

  • @rosembergrodriguesdossanto7711
    @rosembergrodriguesdossanto7711 5 років тому

    Bom dia meu canarada manda ai esse seu projeto do eólico detalhado

  • @mehmedmehmedov5901
    @mehmedmehmedov5901 4 роки тому

    bravo

  • @pauljanssen2624
    @pauljanssen2624 5 років тому +2

    Good diagram bad soldering skill

  • @daviddavids2884
    @daviddavids2884 5 років тому +1

    some late info. though the source is a trusted one, the wisdom of this mod is suspect. in most parts of the world, interconnecting Adjacent coils in a pma, is NOT recommended. why is this true. ALL the coils in a PHASE should be energized Equally and SIMULTANEOUSLY. this cannot happen where adjacent coils are interconnected. for Any STATOR, phases should consist of groups of Three, equally spaced coils, connected in Series. in the context of a pma application, a stator like this should be considered a 16-phase stator. the primary goal of any power system is not battery charging. it is putting WATTS into a Power processing device/circuitry/charge controller. googletranslate

  • @lionelroger626
    @lionelroger626 5 років тому

    SUPER!!!!!!!

  • @oqueedeuseoquechamadodeus5346
    @oqueedeuseoquechamadodeus5346 5 років тому +1

    legal

  • @игорьслюсаренко-ъ7щ

    молодца. поставить такую катушку на генератор серла можно поди 5000 квт срезать сразу.

  • @bobosaeed
    @bobosaeed 4 роки тому

    بسیار عالی

  • @mxsteven
    @mxsteven 4 роки тому

    The whole video only the bike caught my eye....

  • @abdul-q-khan
    @abdul-q-khan 4 роки тому

    👍

  • @SERGEY-KACHAN
    @SERGEY-KACHAN 5 років тому

    Вечный двигатель БТГ ua-cam.com/play/PLlEX99xZE8qOnAHYFeLMyJfAVF7KFIexW.html