Depth of Electrical Earthing (urdu , Hindi)

Поділитися
Вставка
  • Опубліковано 16 кві 2021
  • Unicorn Energy Systems is a professional company in Lahore which provide following Services. Contact/WhatsApp 0335-4946498
    1: Solar PV system Installation
    2: Electrical Earthing Design and Services
    3: Power DB panels
    4: Pressure Pumps with VFDs
    3: Lightning Arrestor System Design and Installation Services, Surge Protectors
    4: Manufacturer/ Supplier of Earthing Chemical, Super Earthing GEL, Bentonite Earthing Chemical
    5: Earthing Equipments/ Material, Earthing Electrodes
    6: Electrical System Inspection Services
    7: Solar Panels and Electrical System Thermal Imaging Inspection
    8: Energy Audits
    9: Soil resistivity test/ Electrical Earthing Tests
    Contact/WhatsApp 0335-4946498
    www.unicornenergysystems.com
    #solar #earthing #lightning_arrestor #Solar_energy #solar_panles #electrical_earthing #electrical_grounding #bentonite_earthing #fawad_baig
  • Наука та технологія

КОМЕНТАРІ • 78

  • @AgroEngineer
    @AgroEngineer Місяць тому +1

    Main bhi Kafi pareshan tha depth k bare lekin aj tasalli ho gai hy thanks sir saty blessed

  • @arslanshakoor11
    @arslanshakoor11 Місяць тому +1

    Gypsum is poured because it has the ability to absorb moisture from soil to reduce the resistivity of soil. Depth is necessary to reach a water. reservoir to keep the earth moist

  • @MuhammadIqbal-hl6mx
    @MuhammadIqbal-hl6mx 2 роки тому +1

    Great, thanks 👍
    from Karachi

  • @ahmadkhalid2547
    @ahmadkhalid2547 2 місяці тому +1

    very informative video.

  • @gulahmed6875
    @gulahmed6875 3 місяці тому +1

    Well explained ❤

  • @shahidfarooq2070
    @shahidfarooq2070 3 місяці тому

    Excellent Knowledge 👍

  • @embeddedzone
    @embeddedzone Рік тому +2

    Very good sir,
    Appreciate🙏....
    Best wishes from India🇮🇳🇮🇳

  • @mumtazawan9458
    @mumtazawan9458 Місяць тому

    Very informative 👍

  • @causelistbranchdsjmardan614
    @causelistbranchdsjmardan614 2 місяці тому

    good information about earthing❤

  • @ishfaqahmad9001
    @ishfaqahmad9001 Місяць тому

    Informative video

  • @techchat370
    @techchat370 5 місяців тому

    bhai ghar main khuwan well hai and depth 26 feet hai and base main geeli matti agar main us main copper rod dal loin to kam chal jai ga? us kuwahin sya hum pani bhi use kartay hain trough plastic pipe through motor

  • @aqbaig0174
    @aqbaig0174 5 місяців тому +1

  • @faisalrazzaq5725
    @faisalrazzaq5725 3 місяці тому

    sir district sahiwal me kitny feet bore hona chshiye for earthing

  • @JawadKhan-et4rc
    @JawadKhan-et4rc Рік тому +3

    Very good

  • @HADI10764
    @HADI10764 2 місяці тому

    Brother Lahore kya charges le rahe hain aap for Solar System Earthing.

  • @tayyabimranmahatir
    @tayyabimranmahatir Місяць тому

    Bijli ke earthing kis liye ke jati?iska kia maqsad hota hai electrical earthing ka?

  • @wajidmalik4725
    @wajidmalik4725 Рік тому +3

    Thanks for information
    If you spread more knowledge,you will be rewarded more.plesse mention your name and qualifications

    • @unicornenergysystems
      @unicornenergysystems  Рік тому

      Jazak Allah
      I am Fawad Baig, i am Electrical Engineer and experience in electrical earthing system design

  • @tabassamtabassam1669
    @tabassamtabassam1669 3 роки тому +3

    Hello sir in Sialkot you can provide your service for earthing and what can be the cost

  • @muhammadrehan69
    @muhammadrehan69 6 місяців тому +1

    Earth jaga kee pillars men Laga sakty hen

  • @mohammaduzair88
    @mohammaduzair88 Рік тому +1

    Mera pc buhat earth marta ha kia m wall me keel thok k ground kr sakta ho?

  • @taimoorshah8230
    @taimoorshah8230 8 місяців тому +1

    agar app ne earth apne garden mai lagana hai to 10 foot ki rod zameen mai thok dou app ka earth lag jaye ga kyun k app apne garden ko wese bhi pani daite rethe ho to app ko 20 foot ka bore karne ki koi zaruat nahi.

    • @unicornenergysystems
      @unicornenergysystems  7 місяців тому

      Esy Earth theek kam nhi kary ga. Earth k liye pani sirf in 20% tak ehm hy. Baki 80 % or cheezen important hen

  • @ahmedbilal8837
    @ahmedbilal8837 3 місяці тому +1

    Sir fsd ma raad or boring kitna hona chaye

  • @raheelahmed9206
    @raheelahmed9206 7 місяців тому +1

    Sir earth ki capacity kya hona chaia

  • @iadilehsan
    @iadilehsan 16 днів тому +1

    Wrong info about length and diameter. The conductivity is increased two times more in case of diameter as compared to length

    • @unicornenergysystems
      @unicornenergysystems  16 днів тому

      Conductor resistance is different thing and earthing resistance ia different things
      At earthing resistance, formula for conductor resistance does not apply

  • @qaisershehzad
    @qaisershehzad 3 роки тому +3

    Pl review your statement reg rod length & diameter. As resistance increases with the increase of length while decreases with the increase of diameter.
    Hence lengthy conductor/rod reduces the current flow while larger dia of conductor/rod increases current flow...

    • @unicornenergysystems
      @unicornenergysystems  3 роки тому +1

      Electrical Earthing Resistance is different than conductor resistance.
      You are correct in term of conductor resistance.
      But in case of electrical earthing Resistance decrease by 40% as length gets double

    • @unicornenergysystems
      @unicornenergysystems  3 роки тому +1

      Think in terms of contact area of conductor and earth soil. As length doubles contact area doubles and hence decrease in contact resistance.

    • @qaisershehzad
      @qaisershehzad 3 роки тому

      @@unicornenergysystems yes if earth strip or bare conductor touches the soil it becomes earth but what about diameter???

    • @qaisershehzad
      @qaisershehzad 3 роки тому

      Actually it depends upon Followings:::
      Type of soil.
      Clay, sand, clay with sand mix etc
      Clay has 40, sand has 2000, clay & sand mix has 100 soil resistivity. U ve to dig till achieving the type of soil that has low value of resistivity.
      Soil resistivity reduces by...
      Soil moisture means wet soil.
      Depth of soil.
      Adding salt contents ( copper/magnesium sulphate or sodium chloride.

    • @qaisershehzad
      @qaisershehzad 3 роки тому +1

      If you use copper earthing conductor of 35mm2 it has 0.55ohm/ km whereas if u use 50mm2 it had 0.39ohm/km.
      Earthing conductor may of bare/strip/rod.

  • @atiqrahmanlodhi4709
    @atiqrahmanlodhi4709 Рік тому +1

    agr zamein k upper upper hi rakh dein tu eath ho jay ga

  • @malikgulshan3271
    @malikgulshan3271 2 роки тому +2

    آواز بہت کم ہے

    • @imac786
      @imac786 Рік тому +1

      Sounds fine on my phone. Check your speaker

  • @blackmouse2248
    @blackmouse2248 3 роки тому +5

    How to verify home earthing?

    • @unicornenergysystems
      @unicornenergysystems  3 роки тому +1

      You can verify earthing with earth testing meter. But usage of earth testing meter is complex and only trained person can use it

    • @qaisershehzad
      @qaisershehzad 3 роки тому

      If your earth resistance is lower than 3 Ohm or 5 Ohm to some extent, it means your earthing is good. Value can be measured by earth resistance meter. My opinion, it should be less than 3 Ohm for power earthing.

    • @unicornenergysystems
      @unicornenergysystems  3 роки тому +1

      @@qaisershehzad it is not matter of opinion. International standards are made after multiple industrial and environmental testing effects.
      One person opinion doesn't matter.
      Value of resistance is important. And lower value is mostly required according to reason of earthing.
      In some applications high resistance earthing is recommended.
      Unless you get reading of Electrical Earthing science and engineering point of views of NEC and IEEE, you will confuse electrical engineering formulas and concept with this different science.

    • @qaisershehzad
      @qaisershehzad 3 роки тому

      @@unicornenergysystems
      Sorry to say...
      Every person has its right to give it's opinion on the basis of his experience & education and exposure. I have IEEE standards. I ve made lot of not only power earthing but also telecom earthing.
      Thanks for replying.... stay blessed

  • @naveedashraf7491
    @naveedashraf7491 9 місяців тому

    sir rahem yar khan main ketne fet pe bor ho

  • @ulfatphotostate7081
    @ulfatphotostate7081 4 місяці тому +1

    Pani tak khod dian to ?

    • @unicornenergysystems
      @unicornenergysystems  4 місяці тому

      Chemical ki life kam ho jaey gi

    • @ulfatphotostate7081
      @ulfatphotostate7081 4 місяці тому

      ​@@unicornenergysystems Pani tak lay gy hen 4 foot ka road adha pani mien thak deya adha uper hy 40 foot bad pani nickal copper road k sath copper ke pati means tar use ke sari kia ya earthing standered ho gyee?

  • @umararsalan5408
    @umararsalan5408 2 роки тому +2

    sir me ne ELCB lagaya hai apnay ghar par but wo kaam nahi kar raha.
    what you suggest me.

    • @unicornenergysystems
      @unicornenergysystems  2 роки тому

      How do you know k wo kam nhi kar rha. How you tested

    • @umararsalan5408
      @umararsalan5408 2 роки тому

      @@unicornenergysystems sir mujhe current laga hai ek dafa Lekin wo trip nahi howa

    • @unicornenergysystems
      @unicornenergysystems  2 роки тому

      Change kar k orignal company ka 30mA ka lagaen

    • @umararsalan5408
      @umararsalan5408 2 роки тому

      @@unicornenergysystems which company suggests you

    • @unicornenergysystems
      @unicornenergysystems  2 роки тому

      @@umararsalan5408 any company is equally good. Just buy forn orignal dealer

  • @fahadshaikh865
    @fahadshaikh865 2 роки тому +1

    Buhat lambi kardi.ya bhe tu batao karna kiya ha bhai...

  • @DieselGeneratortraining
    @DieselGeneratortraining Рік тому +1

    Jis jis bhai nay diesel generator ki training videos dekhni hai wo power learning channel per aa kar subscribe karlay free offer hain 😄 😀😀😀😀😀