Frymaster - booming - heat failure

Поділитися
Вставка
  • Опубліковано 13 гру 2024

КОМЕНТАРІ • 15

  • @justanoldhandyman
    @justanoldhandyman 15 годин тому +2

    You are good about proving what the problem really is.👍

  • @lewiemcneely9143
    @lewiemcneely9143 20 годин тому +1

    Surprises, surprises! Blessings

  • @harrydickson4575
    @harrydickson4575 20 годин тому +2

    👍👍👍

  • @scmxrider613
    @scmxrider613 10 годин тому +1

    i carry 8-10 relays for those and group change them when they look bad.i also find the turning vanes on the blower wheels get clogged up and need to be cleaned so you get full airflow and not late or no ignition. nice work

  • @quertize
    @quertize 20 годин тому +2

    Good catch. At least those relays are in sockets, that could easily be a board replacement.
    gj

  • @PremierApplianceServices931
    @PremierApplianceServices931 14 годин тому

    Nice find on the relay

  • @CubbyTech
    @CubbyTech 16 годин тому +1

    Fasco makes decent motors - there's a Fasco in my furnace being the inducer fan.

  • @Ishmaellllllllllllll
    @Ishmaellllllllllllll 12 годин тому +2

    I had this same problem before and swapped the relays and solved it as well. How I checked the fan on mines as well I just hooked it up to a 110v outlet and she started to spin 😂. Could’ve also just jacked it into the other side with the fan working

  • @jvcajw1
    @jvcajw1 15 годин тому +3

    Curious, why you didn't check the voltage going to the fan motor before removing the fan?
    Is there a preventive maintenance on those fryers? To catch all the grease getting sucked in and accumulating on the fan intake?

    • @restaurantrepairs
      @restaurantrepairs  15 годин тому +1

      Statistical history… correct thing would have been testing voltage first you are absolutely correct. I find them failed or operable. Never partially, so when it was kicking but not starting I got ahead of myself. There obviously isn’t any preventative happening on THIS fryer but I’ve ordered all three relays and we’ll remove and clean all three fans as well. That’s a system ripe for causing cracked burners which will be a 1300 repair

  • @thinkpad4
    @thinkpad4 14 годин тому +1

    Please at least wipe off those fan blades. It's killing me seeing them like that

  • @Hudson12339
    @Hudson12339 21 годину тому +3

    Eww a fry master 💩

    • @restaurantrepairs
      @restaurantrepairs  21 годину тому +2

      Facts…

    • @Hudson12339
      @Hudson12339 21 годину тому +1

      @ Henny Penny all day long 🫡..The worst is changing the heating elements on frymasters