Automatic Motor Adaptation (AMA) on a Danfoss VFD. #vfd #autotuning #danfoss #ama
Переглядів 144Місяць тому
In this video explaining how to do Auto tunning or AMA of induction motor through Danfoss VLT drive Auto tunning of induction motor through Danfoss VLT FC 301 FC302 model VFD !! Danfoss VLT VFD Auto tunning kese kre Danfoss VLT VFD me AMA kese kre #vfd #danfoss #electrical #yaskawa #GA700vfd #GA700 #a1000 #electronics #ama Induction Motor Auto tunning through Danfoss VLT drive VFD #danfoss #vfd...
Auto tunning of induction motor through Yaskawa GA700 VFD !! Yaskawa GA700 VFD Auto tunning kese kre
Переглядів 125Місяць тому
Auto tunning of induction motor through Yaskawa GA700 model VFD !! Yaskawa GA700 VFD Auto tunning kese kre #vfd #danfoss #electrical #yaskawa #GA700vfd #GA700 #a1000 #electronics Induction Motor Auto tunning through Yaskawa GA700 VFD #yaskawa #vfd #electrical #drive #a1000 #GA700 VFD में Auto Tuning कैसे करें | yaskawa vfd auto tuning | vfd auto tuning | auto tuning in vfd | "Is video mein hum ...
Motor Auto tunning through Yaskawa A1000 VFD #yaskawa #vfd #electrical #drive
Переглядів 242Місяць тому
Induction Motor Auto tunning through Yaskawa A1000 VFD #yaskawa #vfd #electrical #drive #a1000 VFD में Auto Tuning कैसे करें | yaskawa vfd auto tuning | vfd auto tuning | auto tuning in vfd | "Is video mein hum yaskawa A1000 VFD ki auto tuning process ke baare me baat karenge. Auto-tuning ka use kar ke aap apne motor aur VFD ke performance ko improve kar sakte hai or Power saving kar sakte hai....
Induction motor full load ampere calculation #motor #ampere #fullload #calculation
Переглядів 114Місяць тому
Induction motor full load ampere calculation as per motor name plate data #motor #ampere #fullload #calculation
How reset warning W24 external fan fault in Danfoss VLT !! #vlt #danfoss #vfd #electrical #faults
Переглядів 593Місяць тому
How reset warning W24 external fan fault in Danfoss VLT !! drive #danfoss #vfd #electrical #faults warning W24 warning W34 External fan fault 24 danfoss VLT drive fault alarm reset Alarm 24 warning W24 kya hota hai warning W24 kese reset krte hai warning W24 kyo aata hai @electro139tech electrical inverter
Danfoss VLT drive FC 301/302 SCR IGBT Repairing #danfoss #vfd #electrical @electro139tech #igbt
Переглядів 322Місяць тому
Danfoss VLT drive FC 301/302 SCR IGBT Repairing #danfoss #vfd #electrical @electro139tech danfoss vfd repairing SCR IGBT Danfoss drive me SCR IGBT kese change kre Drive repairing How to replace 90KW Danfoss VFD SCR IGBT FC 301/302 How to replace danfoss VFD SCR How to replace danfoss VFD IGBT Repair danfoss inverter FC 301 SCR IGBT burn
VFD DC voltage calculation !! AC to DC voltage calculation in VFD !! @electro139tech
Переглядів 2462 місяці тому
AC to DC voltage calculation in VFD !! vfd ac to dc
Yaskawa Drive A1000 Rectifier & IGBT check through multimeter ! #yaskawa #igbt #vfd #rectifier
Переглядів 5032 місяці тому
Yaskawa Drive A1000 Rectifier & IGBT check through multimeter ! #yaskawa #igbt #vfd #rectifier igbt checking with multimeter igbt check karne ka tarika igbt module check karne ka tarika vfd igbt check drive igbt testing igbt kaise check karte hain vfd ka igbt kaise check kare
How to check 3 Phase Rectifier with help of multimeter
Переглядів 1213 місяці тому
How to check 3 Phase Rectifier with help of multimeter !! Rectifier testing kese kre Rectifier check kre Rectifier multimeter se kese check kre Rectifier testing Rectifier working Rectifier value checking 3 phase Rectifier kese check kre 3 phase Rectifier testing with multimeter Rectifier kesa dekhta hai Rectifier kya hota hai Rectifier kya kaam krta hai Rectifier kesa kaam krta hai Rectifier t...
Yaskawa A1000,T1000,V1000 Basic programming parameters settings for motor #programming #vfd #yaskawa
Переглядів 1,9 тис.3 місяці тому
Yaskawa A1000,T1000,V1000,H1000 Basic programming parameters settings to run motor #programming #vfd #yaskawa !! Yaskawa A1000 drive parameter settings Yaskawa T1000 drive parameter settings Yaskawa V1000 drive parameter settings Yaskawa H1000 drive parameter settings VFD programming VFD parameters settings VFD programming kese krte hai VFD parameters settings kese krte h VFD parameters setting...
Yaskawa drive Local mode selection for motor run #vfd #yaskawa #local
Переглядів 923 місяці тому
Yaskawa drive Local mode selection for motor run #vfd #yaskawa #local
Yaskawa drive LF alarm explained in detail #vfd #yaskawa #electrical #alarm #faults
Переглядів 914 місяці тому
Yaskawa drive LF alarm explained in detail #vfd #yaskawa #electrical #alarm #faults
Fault alarm history details check in Danfoss VLT drive #danfoss #vlt #vfd #alarm #history
Переглядів 3924 місяці тому
Fault alarm history details check in Danfoss VLT drive #danfoss #vlt #vfd #alarm #history
How to change Danfoss VLT drive language settings
Переглядів 2104 місяці тому
How to change Danfoss VLT drive language settings
How to Delete Danfoss VLT drive LCP display parameters
Переглядів 324 місяці тому
How to Delete Danfoss VLT drive LCP display parameters
Danfoss VLT 360 Drive parameters copy paste function through LCP display !! @electro139tech #vfd
Переглядів 3074 місяці тому
Danfoss VLT 360 Drive parameters copy paste function through LCP display !! @electro139tech #vfd
Yaskawa Drive parameters copy paste function through LCP !! @electro139tech #yaskawa #vfd #a1000
Переглядів 1924 місяці тому
Yaskawa Drive parameters copy paste function through LCP !! @electro139tech #yaskawa #vfd #a1000
How to reset warning W34 Fieldbus fault in Danfoss VLT drive #danfoss #warning #W34
Переглядів 4 тис.4 місяці тому
How to reset warning W34 Fieldbus fault in Danfoss VLT drive #danfoss #warning #W34
How to factory reset (initialisation process) in Danfoss VLT drive
Переглядів 2674 місяці тому
How to factory reset (initialisation process) in Danfoss VLT drive
SECURE ELITE 300 MULTI FUNCTIONAL METER PROGRAMMING @electro139tech #elite #schneider #meter #300
Переглядів 7578 місяців тому
SECURE ELITE 300 MULTI FUNCTIONAL METER PROGRAMMING @electro139tech #elite #schneider #meter #300
How to run yaskawa VFD in mannual mode !! @electro139tech #yaskawa #local #vfd #electrical #T1000
Переглядів 1149 місяців тому
How to run yaskawa VFD in mannual mode !! @electro139tech #yaskawa #local #vfd #electrical #T1000
How to start motor on hand mode using danfoss VLT drive #vfd #danfoss #electrical #reference
Переглядів 4 тис.Рік тому
How to start motor on hand mode using danfoss VLT drive #vfd #danfoss #electrical #reference
How to check Danfoss drive identification data @electro139tech #danfoss #electrical #vlt #vfd
Переглядів 44Рік тому
How to check Danfoss drive identification data @electro139tech #danfoss #electrical #vlt #vfd
How reset KWH reading of conserv EM1200 Schneider electric energy meter
Переглядів 801Рік тому
How reset KWH reading of conserv EM1200 Schneider electric energy meter
How to program different meters in electrical panels
Переглядів 37Рік тому
How to program different meters in electrical panels
How to check Danfoss VLT FC-302 Drive identification
Переглядів 1,6 тис.Рік тому
How to check Danfoss VLT FC-302 Drive identification
L.A (Lightning Arrester ) changing on 33KV line.
Переглядів 175Рік тому
L.A (Lightning Arrester ) changing on 33KV line.
Fluke 62 Max IR Thermometer laser on/off and other settings
Переглядів 2,7 тис.Рік тому
Fluke 62 Max IR Thermometer laser on/off and other settings
Hi sir, i have Yaskawa Varispeed 626vm3 and i have error code, F-604 how to fix please?
Turn off drive power and check following. check first loose connection in your drive or check fuse inside the it may be loose or derated Also check power card connection
@@electro139tech I have read the instructions in the book, and I have checked them all. here. ok but the problem remains
Hello Sar Mujhe Jankari chahie Motor Mechanic ka kya
Kesi jankari
❤
🙏
hello sir, 14-10 me 0 ( No function) ya 6 ( Alarm ) .. dono me se konsa set karna hoga vo kispe depend karta hai ?
According to your application Or kya aap ki drive load sharing kr rhi hai If VFD pr load sharing nhi hai to aap 0 (NO function) set kr skte h
👏
🙏
Nice भाई मैं भी कोशिश कर करू पर चैनल केटेगरी किया रखे
बताओ ना
As per your topics
@@electro139tech आप ने किया रखा है केटेगरी
if we want to increase these Kw how to increase?
By changing power card with higher rating with respect to existing
Nice
Thanks
Is this the same as thermal imaging camera?
No it's working with infrared ray
सब समझ में आगया सर.
👌👍
Bhai during this type ,which position the selector switch should be?
Selector switch should be on Local mode selection
Value kitna aana sshiyw mini mum
It's depends upon semiconductor material Mostly 0.3 - 0.6 V
Accha ha bhai
Thank you 🙏
Alarm 24
ua-cam.com/video/cjtPBCradSM/v-deo.htmlsi=dd91b3ycLSgSSi_P
Apni application ke according ka mtlb kya h sir hamare usme alarm aa rha h setting set krte time
Application means according to working process of machine or else Please share alarm
Well 👍 I m your new subscriber
Thank you
Nice
Thank you
But when I do something like you, the error is cleared, but the engine does not start. What is the reason?🎉
Check further settings regarding your application
So check further settings regarding your application
Good 👍 work
Thank you so much 😀
How do you calculate the filter?
According to harmonics level
Nice👍
Thanks ✌
Discharge kaise karte hai taki jhatka na lage
Megger ki dono pins ko short kr ke discharge karte hai
Does fluke max 59 also has laser?
Yes
Sab rectifier value check kiye to yahi reading same reharethai alag alag rehate batao
Rectifier value depends Silicon diodes: 0.6-0.7 volts Germanium diodes: 0.2-0.3 V aap jab bhi Rectifier check kre tab teeno phase me almost same reading hona chahiye
Good explain
Thank you
Easy explation
Thank you 👍
Very informative video
Thank you 👍
Good information
So nice of you
Easy to understand
Thank you 👍
Good job
Thank you 👍
❤❤❤❤❤
Thank you 👍
Nice 👍
Sir demand set value only kw ?
Yes
Doubt? Igbt value ok , what about converter value i mean diode value????
Drive input is known as Rectifier (converter) side
1 kw connection 1.69 ho gaya hai
Change Upper and lower demand limit
Digital meter me kaise hoga
Meter make....?
sir drive repair video best hai
Thank you 👍
Very nice explain and Very informative videos keep it up. Thank you very much sir
Thank you 👍
Thanks for knowgable video sharing.
Thank you 👍
What app number
Meco mitar 3510phw par or video banao
Okay 👍
Aap ne bola positive negative short hoga to problem hoga. Multimeter se check karne par countinuity bata raha hai fir tum bol rahe ho ok hai
Please watch clearly In short circuit multimeter show zero (0) reading or giving continue continuity bipe alarm and here you can see clearly diode value show in multimeter
Nice sir ji no. Please
Thank you
Waoo keep it sir loooove you..
Thanks
English please
Very soon
Sir please batiya ki double lap ki cleabration kise kartan hani
Aap ke pass carding model kon si h
It still not 0 sir.?
I believe you are doing this in load running condition
How to plc verson change
Go for software update
Very good. Thanks 🙏🙏🙏🙏
Most welcome
Reading view
Yes