Parr Instrument Company
Parr Instrument Company
  • 26
  • 66 436
Celebrating 125 Years of Innovation and Growth
Celebrating 125 years of developing high-quality laboratory research equipment, we honor our history and share an exciting glimpse into our future.
Переглядів: 291

Відео

Parr at ACHEMA 2024
Переглядів 685 місяців тому
Parr’s stand at ACHEMA 2024 has been bustling with activity! Come see us at Hall 4.1, Stands B71-77 to find out how Parr equipment can help with your high pressure, high temperature research needs!
25L Stirred Reactor System with Telescoping Stand
Переглядів 3199 місяців тому
Parr Reactor Systems are highly customizable to meet application or space requirements. Parr was recently asked to design a 25L Stirred Reactor System that could be easily rolled into the user’s walk-in fume hood for use, then rolled out for storage between experimental campaigns. The design includes: - Telescoping stand - Tilt-to-empty vessel assembly - Safety interlocks between pneumatic tele...
500 Firing Maintenance for Parr 6400 Automatic Isoperibol Calorimeter
Переглядів 1,8 тис.Рік тому
Follow this step by step video to learn how to replace the necessary O-rings and seals in Parr's 6400 Calorimeter as part of the 500 Firings Maintenance. Maintenance should be performed after every 500 firings, six months, or when there is any degradation in O-ring materials.
Parr 4878 Automated Liquid Sampler video
Переглядів 3803 роки тому
Learn about our 4878 Automated Liquid Sampler in our latest video! The 4878 allows for the extraction of multiple samples at user-defined intervals from any Parr reactor or pressure vessel while at operating temperature and pressures up to 5,000 psi and 500 ˚C. Learn More: www.parrinst.com/products/specialty-custom-systems/4878-automated-liquid-sampler/?UA-cam&UA-cam
Parr Reactor Fittings
Переглядів 6 тис.3 роки тому
In this short video we identify the standard head fittings available for Parr’s stirred reactors and discuss custom options available. Learn More: www.parrinst.com/products/stirred-reactors/
Parr Reactors Overview
Переглядів 6 тис.3 роки тому
See a quick overview of the breadth of Parr's Reactor and Pressure Vessel product lines. Learn about vessel size range, the difference between fixed and moveable heads, support stand options, and more! Learn More: www.parrinst.com/reactors-pressure-vessels/ 0:00 Vessel Sizes 0:29 Fixed vs. Movable Head Designs 0:58 Fixed vs. Moveable for Larger Vessels 1:27 Controllers 1:37 Custom Systems
Parr Series 8500 50L & 100L Stirred Reactor Systems
Переглядів 7053 роки тому
Parr Instrument Company is excited to announce a new series of large capacity, high pressure stirred reactors. Offered in 50 L, 100 L, and other large volumes, the new 8500 Series expand the available volume of our standard offering by more than five times, while retaining the easy-to-use features our customers have come to expect from Parr. Ideally suited for scale up or pilot work, the geomet...
Parr 1108 Oxygen Combustion Vessel 500 Firing Maintenance
Переглядів 2,5 тис.3 роки тому
Follow this step by step video to learn how to perform the 500 firing maintenance for a Parr 1108 Oxygen Combustion Vessel. Maintenance should be performed after every 500 firings, six months, or when there is any degradation in O-ring materials.
ParrEd Introduction
Переглядів 1,1 тис.4 роки тому
ParrEd is Parr's new educational video series which will describe how to use and service Parr equipment, discuss historical & special use cases, as well as answer frequently asked questions.
Manufacturing High Quality Pressure Vessels
Переглядів 6954 роки тому
Parr pressure vessels are manufactured in the USA in accordance with accepted codes and practices to ensure safe and high quality products. Machining pressure vessel cylinders from solid, hot-rolled bars or forgings results in smooth vessels without seams or welds, eliminating potential sources of weakness or localized corrosion. See some of the craftsmanship that goes into building a Parr vessel!
Continuous Flow Tubular Reactor with Touchscreen Control
Переглядів 1,1 тис.4 роки тому
Parr’s new Continuous Flow Tubular Reactor with Touchscreen Control was designed with researchers in mind. It offers a compact footprint, easy set-up, and integrated touchscreen control with alarm interlocks, all at a budget-friendly price. Whether for production, research, or teaching unit operations, this system has an impressive collection of capabilities. Learn more at www.parrinst.com/prod...
Tilt-to-Empty 5 Gallon Stirred Reactor
Переглядів 7924 роки тому
Parr's tilt-to-empty feature allows for easy removal of abrasive slurries, biomass particles, or other materials that are incompatible with bottom drain valves. A pneumatically operated tilt-to-empty mechanism is installed on this 5 gallon high pressure, high temperature stirred reactor system. Let us build one for you! www.parrinst.com/products/stirred-reactors/options-accessories/tilt-to-empt...
Tilt-to-Empty 30 L Stirred Reactor
Переглядів 6254 роки тому
Parr's Tilt-to-Empty feature aids in emptying large reactors and reactors containing abrasive slurries, biomass particles or other materials incompatible with bottom drain valves. See this feature in action on a 30 liter high pressure stirred reactor. Let us build one for you! www.parrinst.com/products/stirred-reactors/options-accessories/tilt-to-empty-feature/
Parr Tubular Reactor with 360° Tilt
Переглядів 6054 роки тому
Parr Tubular Reactor with 360° Tilt
Parr Footless Mag Drive Maintenance
Переглядів 2,8 тис.5 років тому
Parr Footless Mag Drive Maintenance
Parr Mag Drive Maintenance
Переглядів 8 тис.5 років тому
Parr Mag Drive Maintenance
Parr Hinged Split-Rings
Переглядів 8655 років тому
Parr Hinged Split-Rings
Parr Corporate Profile
Переглядів 1,4 тис.5 років тому
Parr Corporate Profile
Mechanical Tilt-to-Empty Feature
Переглядів 7426 років тому
Mechanical Tilt-to-Empty Feature
Parr Tubular Reactor Assembly Time-lapse
Переглядів 1,3 тис.7 років тому
Parr Tubular Reactor Assembly Time-lapse
Coal & Coke Burn Times
Переглядів 2,6 тис.7 років тому
Coal & Coke Burn Times
Parr 6400 Calorimeter Installation Guide
Переглядів 18 тис.10 років тому
Parr 6400 Calorimeter Installation Guide
Parr Instrument Company Custom Horizontal Reactor System
Переглядів 84510 років тому
Parr Instrument Company Custom Horizontal Reactor System
Parr Instrument Company Gas Entrainment Stirring Demonstration
Переглядів 2,5 тис.12 років тому
Parr Instrument Company Gas Entrainment Stirring Demonstration
Parr Instrument Company Custom Reactor System - 908422
Переглядів 5 тис.13 років тому
Parr Instrument Company Custom Reactor System - 908422

КОМЕНТАРІ

  • @CRYOF230
    @CRYOF230 27 днів тому

    And congratulations

  • @CRYOF230
    @CRYOF230 27 днів тому

    Hello dear sir any vacancy for instrument calibration technician

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 26 днів тому

      Hello, we do not have any openings for that position currently. You are welcome to review our current openings at www.parrinst.com/company/employment-opportunities/.

  • @65saleemahmed
    @65saleemahmed Місяць тому

    On behalf of the M/s. Ghiath M Kaki Est., Saudi Arabia, CONGRATULATIONS to the whole team of Parr Instruments Company for celebrating the completion of 125 years. My company feels proud to be with Parr for more than four decades and myself to be around 34 years.

    • @ParrInstrumentCompany
      @ParrInstrumentCompany Місяць тому

      Thank you Mr. Ahmed. We are grateful to you and to M/s. Ghiath M Kaki Est. for our successful collaboration.

  • @soumyabapu3457
    @soumyabapu3457 Місяць тому

    How to disable start

    • @ParrInstrumentCompany
      @ParrInstrumentCompany Місяць тому

      Thank you for your comment. I assume that you are trying to get the START button active. The START and START PRETEST buttons are deactivated if the heater and pump are off or if the jacket temperature is out of tolerance. The tolerance for the jacket temperature is 29.5 to 30.5 C. Once the jacket temperature reaches that range it will take an additional 15 minutes before the buttons becomes active to make sure that the temperature is stable. To disable the START button, just turn off the heater and pump. If you need any additional information please feel free to call us at (309)-762-7716 or or send an email to parr@parrinst.com and one of our Calorimeter Technical Representatives can assist.

  • @energialibreisrael
    @energialibreisrael 2 місяці тому

    our company need reactor for methanol producer

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 2 місяці тому

      Please contact us at parr@parrinst.com so we may get further details and your contact information.

  • @energialibreisrael
    @energialibreisrael 2 місяці тому

    i write to this company but no have answer need laboratory reactor for methanol

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 2 місяці тому

      Thank you for your interest in our products. Please contact our exclusive representative in Israel for further information or if you would like to place an order. Medent Ltd. 110 Mordey Hagetaot Street 84206 Beer-Sheva, Israel 972 8 6237984 info@medent.co.il Best Regards, Parr Instrument Company

  • @sanusiakintunde9548
    @sanusiakintunde9548 Рік тому

    Please make a video of how to couple the reactor parts together for new customers for easy access. 4560 is my desire

    • @ParrInstrumentCompany
      @ParrInstrumentCompany Рік тому

      I'm sorry we are not able to make such a video at this time. We often use Swagelok fittings on our reactors, their website www.swagelok.com might be of use for you. You may also email us at parr@parrinst.com for further assistance.

  • @barbarabrkovich1988
    @barbarabrkovich1988 Рік тому

    Why is it so loud

    • @ParrInstrumentCompany
      @ParrInstrumentCompany Рік тому

      Hello Barbara, Thank you for your comment. There are many components of the 6400 that can cause noise in the system. Depending on the age of the instrument, this can either be a sign of a component that needs to be replaced or normal operation. The exhaust of the pressure from the inside of the combustion vessel can be somewhat surprising at first. 450psi of oxygen is being release from a 3/8” diameter tube into a smaller collection vessel. The vessel is also rinsed/washed a few times to ensure that everything is clean. This uses the same 450psi of oxygen pressure. If this is an issue, the tubing from the exhaust and vent connections for the back of the calorimeter can be plumbed to a larger container or to a space outside of the lab. If you need any additional information please feel free to call us at (309)-762-7716 or or send an email to parr@parrinst.com and one of our Calorimeter Technical Representatives can assist.

  • @ch.furtado8888
    @ch.furtado8888 2 роки тому

    please record a video explaining how to operate the supercritical Parr Model 4790STAND?

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 2 роки тому

      Thank you for your video suggestion. We will add it to our list. In the meantime, please contact us at parr@parrinst.com if you would like one of our technical representatives to assist with your operating questions.

  • @aitzazahmad5347
    @aitzazahmad5347 2 роки тому

    Sir, I have Parr Bomb Calorimeter Instrument of Model No.6200. When I am operating this instrument for analysis then come to face a problem of touchscreen hanging and system hanging. How to Troubleshoot this error of instrument ? How to get rid of this problem ? There is no such instruction or guidance in the Manual for this error / issue. Instrument Name : Parr 6200 Isoperibol Calorimeter

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 2 роки тому

      Hello Mr. Ahmad, we would be happy to help. Please email us at parr@parrinst.com.

  • @KAyabGC
    @KAyabGC 3 роки тому

    How to reset the controller?

  • @Dineshkumar-sf5xv
    @Dineshkumar-sf5xv 3 роки тому

    Andrei, can i set a password to switch on my Parr 6400 calorimeter, for safety,,

  • @filmi_12
    @filmi_12 3 роки тому

    hello i have parr 6400 inactive start buttons

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 3 роки тому

      Hello Samvel, please contact us at parr@parrinst.com so that we can help you.

  • @jeffbobson9459
    @jeffbobson9459 3 роки тому

    Hello, would it possible if you could upload a guide on how to use the parr temperature controller 4848 as I see it in all of your videos,

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 3 роки тому

      We don’t have a 4848 operation video currently, but we could certainly create one in the future. In the meantime, the 4848 operation manual can be found at: www.parrinst.com/products/controllers/4848-reactor-controller/documents/. You’ll need to log in to access the manual. And don’t hesitate to contact Parr customer support with questions at parr@parrinst.com!

    • @jeffbobson9459
      @jeffbobson9459 3 роки тому

      @@ParrInstrumentCompany Thank you very much, and I look forward to seeing your video!

  • @kevins8753
    @kevins8753 3 роки тому

    What is function of vent line?

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 3 роки тому

      Hello! Thank you for your question. The vent line is used to depressurize the oxygen fill line inside the instrument. After the oxygen filling is complete the oxygen fill solenoid is de-energized and the tubing vents out the vent line. When this happens the pressurized gas inside the vessel causes a check valve to seal the chamber.

  • @65saleemahmed
    @65saleemahmed 3 роки тому

    Quite nice video with important information about the basic configuration for first time users.

  • @NeurinRo
    @NeurinRo 3 роки тому

    Great content!

  • @elghonemyeg3003
    @elghonemyeg3003 3 роки тому

    hi sorry for requesting, but it will be very helpful if there an video about calibration, for parr 6400

  • @NeurinRo
    @NeurinRo 4 роки тому

    Great content!

  • @pattisrinivasrao
    @pattisrinivasrao 4 роки тому

    Useful video..

  • @rederrafiq4287
    @rederrafiq4287 4 роки тому

    Question please why the coke last longer? Is it due to number of carbons and other elements to Burn?

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 4 роки тому

      It is hard to tell why exactly those cokes burned longer than coals. Generally the rate of combustion is defined by many things, however primarily it is driven by rates of combustion of the components in the sample, as well as the available surface to the oxygen. Provided that both of those samples have the same particle size, our guess here is that coal burns faster due to higher organic content, whereas coke in comparison is mostly carbon, which burns slower.

    • @rederrafiq4287
      @rederrafiq4287 4 роки тому

      Well, thank you for responding update.

  • @rajeshvaghela5743
    @rajeshvaghela5743 4 роки тому

    Congratulations!!!

  • @rajeshvaghela5743
    @rajeshvaghela5743 4 роки тому

    Hello, I need a Video of the 6200 Bomb Calorimeter Unbox & Installation.

    • @ParrInstrumentCompany
      @ParrInstrumentCompany 4 роки тому

      Hello Rajesh, We currently do not have an installation video for our 6200. The best source for installation is our 6200 Operating Instructions that may be downloaded from our Instruction Manuals page at www.parrinst.com/support/downloads/manuals/. We would be happy to provide further assistance as needed, please contact us at www.parrinst.com/contact/parr-usa/.

  • @JacekThomann
    @JacekThomann 4 роки тому

    That's the content I was really looking for. Andrei I see a new movie star is being born :)

  • @FelipeAquino34
    @FelipeAquino34 4 роки тому

    Congratulations! Wish great Success!!!

  • @amg2022
    @amg2022 12 років тому

    Whoa.