- 219
- 836 268
Station of education
India
Приєднався 5 лис 2017
Hello friends welcome to my channel- technic device, electric formulas, electric device diagrams and new formulas of electrical
Digital weighing scale weight settings.True scale calibration in Hindi
Digital weighing scale weight settings.True scale calibration in Hindi
Переглядів: 22
Відео
goods lift connection and circuit diagram.# JV Automation #LIFT.
Переглядів 5028 днів тому
goods lift connection and circuit diagram.# JV Automation Contact for new electric panel and old panel repairing and modifications JV Automation jvautomation1991@gmail.com 8607020460
Fuji drive connection and parameters settings
Переглядів 112Місяць тому
Fuji drive connection and parameters settings Aap hame contact kare new panel and old panel and old panel repairing ke liye. You can contact us for new panel and old panel and old panel repairing. jvautomation1991@gmail.com Bahadurgarh haryana 124507 8607020460
Cybelec controller 8 CYB touch 8 settings
Переглядів 2654 місяці тому
Cybelec controller 8 CYB touch 8 settings New panel and old panel ke liye hame contact kare JV Automation jvautomation1991@gmail.com Bahadurgarh HR 8607020460
Power saving.
Переглядів 615 місяців тому
power saving kaise kare jvautomation1991@gmail.com 8607020460
CT settings for actual ampere (current) in Hindi, multispan Ammeter settings
Переглядів 826 місяців тому
CT settings for actual ampere (current) in Hindi, multispan Ammeter settings
Returnable timer programming Delta PLC in Hindi
Переглядів 447 місяців тому
Returnable timer programming Delta PLC in Hindi
Delta VFD connection and parameters settings in Hindi(MS300)
Переглядів 6 тис.7 місяців тому
Delta VFD connection and parameters settings in Hindi delta VFD MS300 jvautomation1991@gmail.com
Two pressure and two pump circuit.pressure switch.
Переглядів 1578 місяців тому
Two pressure and two pump circuit.pressure switch. two pressure switch ko circuit mai kaise lgay aur pump ko standby mai kaise rakhe? dono pumpo ko ek sath kab chalana h. pressure switch settings ki video apko hamare channel pr bahut si mil jayegi New panel, modify panel and repair ke liye hame contact kare JV Automation jvautomation1991@gmail.com 8607020460
Automatic/Manual 3Phase phase changer panel.JV automation bahadurgarh HR +91 79836 39264
Переглядів 9310 місяців тому
Automatic/Manual 3Phase phase changer panel.JV automation bahadurgarh HR 91 79836 39264
Single phase preventer best connection /motor safety relay.preventer लगाने का सही तरीका।
Переглядів 153Рік тому
Single phase preventer best connection /motor safety relay.preventer लगाने का सही तरीका।
delta plc programming/PLC programming/first class PLC programming in Hindi
Переглядів 56Рік тому
delta plc programming/PLC programming/first class PLC programming in Hindi
digital timer settings and connection kaise kare/how to connection and settings digital timer
Переглядів 267Рік тому
digital timer settings and connection kaise kare/how to connection and settings digital timer
APFC controller settings/power factor 0.99kaise kare/KVAR settings in Hindi
Переглядів 132Рік тому
APFC controller settings/power factor 0.99kaise kare/KVAR settings in Hindi
Delta VFD connection.single phase connection VFD.Delta drive connection.
Переглядів 272Рік тому
Delta VFD connection.single phase connection VFD.Delta drive connection.
Kansa thali therapy machine contact to buy 7983639264
Переглядів 142Рік тому
Kansa thali therapy machine contact to buy 7983639264
water 💦 tank control system. automatic water pump.2 tank control system (receiver and delivery tank)
Переглядів 239Рік тому
water 💦 tank control system. automatic water pump.2 tank control system (receiver and delivery tank)
Panel manufacturers.Electrical panel manufacturing and modified
Переглядів 112Рік тому
Panel manufacturers.Electrical panel manufacturing and modified
Humidity controller? Programming, settings and connection in Hindi.
Переглядів 308Рік тому
Humidity controller? Programming, settings and connection in Hindi.
digital timer connection and settings in Hindi.
Переглядів 348Рік тому
digital timer connection and settings in Hindi.
Single phase motor automatic forward stop and reverse in Hindi
Переглядів 323Рік тому
Single phase motor automatic forward stop and reverse in Hindi
Forward reverse Stop one button. practical video. in Hindi
Переглядів 418Рік тому
Forward reverse Stop one button. practical video. in Hindi
Digital timer programming and prectical (XT246)
Переглядів 14 тис.Рік тому
Digital timer programming and prectical (XT246)
Reverse Forward star delta starter control wiring/PLC programming Reverse Forward starDelta starter
Переглядів 3482 роки тому
Reverse Forward star delta starter control wiring/PLC programming Reverse Forward starDelta starter
pressure switch connection in hindi/pressure switch/pressure switch circuit connection.
Переглядів 6342 роки тому
pressure switch connection in hindi/pressure switch/pressure switch circuit connection.
Star delta starter/ how to make Star delta starter in hindi
Переглядів 3062 роки тому
Star delta starter/ how to make Star delta starter in hindi
Heater connection single phase and double phase and load divided in hindi
Переглядів 4,9 тис.2 роки тому
Heater connection single phase and double phase and load divided in hindi
Is tarah se connection karne se HP pump Low pressure hoga to bandh ho jayega sirji
Nice
Where is neutral cabel
Sir main pump ko auto Start manually off kese setting kese kare
supar bhai
Niche blue wire kunsa lagaya
Amper का permiitre बताओ
Iss me time ko jyada yaa kaam kese kare sir
6 heater 3kw ko kaisa lagaye star mai ya delta mai ya fir 3 phase dived and nutral common de diya jaye
KYA HUM SINGLE PHASE DO HEATER ME BHI SAME APPLY KAR SKTE HAI STAR CONNECTION
My Kp 35 switch works properly at only one setting that is 40 psi Range and 30 psi differential.But at this setting water pressure is little low.Why on any other settings pump runs very frequently.
Ok
Thanks
Very good information ji
@@harman7328 thanks
Very good sir
Thanks ji
Sir lvdt ka videio banadana sir please ❤❤❤
Ok ji
Sir presar pump ka pa ni Kam jada hone ka kaya kaarn ho sakta h
NRV& pump
Very good teacher
Thanks ji
Sir societyme do(2) motor ho to maximum kitana pressure rakhna chahie???
3.5bar
Wire kitni hoti hai esme
Required ke hisab se lelo
Pressure pump chal raha h auto cut nahi ho raha h please reply
Pressure check kro
What is the maximum current the relay can opertate? I am looking for 10A to operate Microwave oven.
👍
Sir pote 10k pote ki vabe korbo aita to sob bujlam
Sir. 2500 lpd tank may kitna satting rakhna cheya ?
Low voltage ka interview kaise de
3 bathroom ke liye range aur differential kitna rakhe?
2.5-3.5 bar
Minimum kitna range ko rakh sakte h jis se moter start ho jaye automatic
Sir museg counter setting chairs
Good 👍
Tx
Good 👍
Thanks sir ji
Excellent
Nice explain 🎉
Muje pulse dene k bad 1 to 10 sec on karvana he to konsa timer best rahega How can I contact you?
Ho jayega
@@Stationofeducation kese konsa timer best rahega
6kw coil ke liye wire kaun si or mcb kaun sa use karana chahiye
4sqmm cu 32amps MCB
Contector wayaring bataiye is timer me
Video sahi nhi hai kuch dikhata kuch nahi
Ok ji aage koshish karenge aapko achha video Dene ki
Bro my pressure pump range is 70 differential up or down dono time pe pressure pump off hi nhi ho rha sirf chale ja rha hai?? Help
If we set range 3Bar then how much pressure we will put in pressure tank. Please reply, thanks.
240 kha se denge
240 kya h voltage h kya
Aap ne jo kiya wah sahi hay lakin mujhe shak hay ki kp35 water may theek se chalegi, kyuki danfoss company k hisab se kp35 gas k liye hay, water k liye kpi35 hay. Aap ne bhi video me shayad gas pressure diya hay, water pressure nahi diya.
Good
Main apko circuit btaya h
Nice
Tx
Laptron l700news
Very nice
Ghalat bata rhay ho
Minat me seting karna hai
Minutes mai kr do kya problem aarha h
Thanks for teaching us wonderful tips
Tx
Sir motor cut off nahi ho raha hai
Circuit check kro
Sar low voltage or medium voltage kahan per use Kiya jata hai... Yah doubt hai sar thoda clear karo
Thank you🙏