Electrical Engineering in Real Life
Приєднався 12 чер 2022
A case of missing PT supply in 11kV metering. 04.12.2024 @ Umroi Airfield.
A case of missing PT supply in 11kV metering. 04.12.2024 @ Umroi Airfield.
Переглядів: 5
Відео
Energy Recorded by 3 Phase 4 Wire meter is same as recorded by 3 Phase 3 Wire Meter.
Переглядів 821 годину тому
Energy Recorded by 3 Phase 4 Wire meter is same as recorded by 3 Phase 3 Wire Meter.
Calculation of M.F in case of Primary Commisioned meters (Secure Apex 100) used for 132KV Consumers
Переглядів 1114 днів тому
Calculation of M.F in case of Primary Commisioned meters (Secure Apex 100) used for 132KV Consumers
Calculation of M.F in case of Primary Commisioned meters (Secure Apex 100) used for 132KV Consumers.
Переглядів 914 днів тому
Calculation of M.F in case of Primary Commisioned meters (Secure Apex 100) used for 132KV Consumers.
Testing of LT-CT 3x240V, /5A LT-CT HPL Smart Meter using Secure Accucheck LT+.
Переглядів 614 днів тому
Testing of LT-CT 3x240V, /5A LT-CT HPL Smart Meter using Secure Accucheck LT .
Testing (Accuracy check) of LT-CT 3x240V, -/5A Secure Meter using Secure Accucheck LT+.
Переглядів 1014 днів тому
Testing (Accuracy check) of LT-CT 3x240V, -/5A Secure Meter using Secure Accucheck LT .
Accuracy check of LT-CT 3x230V, 50/5A Secure Meter using Secure Accucheck LT+.
Переглядів 1014 днів тому
Accuracy check of LT-CT 3x230V, 50/5A Secure Meter using Secure Accucheck LT .
Accuracy Test for HT meter using Secure Accucheck HT+.
Переглядів 814 днів тому
Accuracy Test for HT meter using Secure Accucheck HT .
How to select the CT Ratio for a particular Contract Demand in 33KV Consumer.
Переглядів 1014 днів тому
How to select the CT Ratio for a particular Contract Demand in 33KV Consumer.
How to generate 12A & 14A of Circulating Current for Injection to primary of 11KV or 33KV CT-PT unit
Переглядів 214 днів тому
How to generate 12A & 14A of Circulating Current for Injection to primary of 11KV or 33KV CT-PT unit
How to generate 23A & 25A of Circulating Current for Injection to primary of 11KV or 33KV CT-PT unit
Переглядів 221 день тому
How to generate 23A & 25A of Circulating Current for Injection to primary of 11KV or 33KV CT-PT unit
Themisto TH-M88 Digital Clamp Meter 26.12.2024.
Переглядів 16121 день тому
Themisto TH-M88 Digital Clamp Meter 26.12.2024.
Calculation of Multiplication Factor (M.F) of 11KV Line Metering Unit.
Переглядів 302 місяці тому
Calculation of Multiplication Factor (M.F) of 11KV Line Metering Unit.
How to choose Between CT-PT Unit vs Energy Meter in 11kV & 33kV System Voltages.
Переглядів 243 місяці тому
How to choose Between CT-PT Unit vs Energy Meter in 11kV & 33kV System Voltages.
How to check the Accuracy of LT-CT meters using 1Ph power source. (Accu. Check LT+)
Переглядів 183 місяці тому
How to check the Accuracy of LT-CT meters using 1Ph power source. (Accu. Check LT )
How to test the correctness of CT ratio | homemade CT injection kit to test 50,100,150,200/5A CT.
Переглядів 294 місяці тому
How to test the correctness of CT ratio | homemade CT injection kit to test 50,100,150,200/5A CT.
An Overview of 11/.433kV Substation at Lumsohpetbneng date 26.07.2024.
Переглядів 154 місяці тому
An Overview of 11/.433kV Substation at Lumsohpetbneng date 26.07.2024.
15kW CLT of Apphira Thangkhiew, Mawlyngkhung. Inspection on 06.08.2024.
Переглядів 34 місяці тому
15kW CLT of Apphira Thangkhiew, Mawlyngkhung. Inspection on 06.08.2024.
PHE Pump House Mawsiatkhnam, near Presbyterian Church. Inspection on 08.08.2024.
Переглядів 214 місяці тому
PHE Pump House Mawsiatkhnam, near Presbyterian Church. Inspection on 08.08.2024.
Missing of PT supply/ Sec. current to any Ph, the power/ energy recorded in that Ph becomes "zero"
Переглядів 274 місяці тому
Missing of PT supply/ Sec. current to any Ph, the power/ energy recorded in that Ph becomes "zero"
How to use 3 Phase Meter in 1 Phase Supply | How to convert 1Ph metering into 3Ph metering.
Переглядів 384 місяці тому
How to use 3 Phase Meter in 1 Phase Supply | How to convert 1Ph metering into 3Ph metering.
14th December, 2017 at Killing Substation.
Переглядів 44 місяці тому
14th December, 2017 at Killing Substation.
28th February 2018 at Killing Substation
Переглядів 14 місяці тому
28th February 2018 at Killing Substation
ua-cam.com/video/6ywgHHIdlZo/v-deo.htmlsi=jg_WtwIQDwaOLDEy
bro i want to buy a metrocil so please suggest a vendor
Is there any power factor shown in the meter??
Prepaid ne bro
Kren da khasi leh bro
Bhaiya apka safety kaha he ???
Khot bylla lang noh iangi da long
60,000. not 600,000 .
This problem are phase to it install in PC please sir its solutions provides -Run time error 339 and component 'MSCOMCTL,OCV' or one of its dependencies not correctly registered a file is missing or invalid plese sir provide its solution
Hello sir 132kv substation par opretar banne ke liye kya eligibility chaiye please Reply sir 🥺
diploma electrical engineering
If red wire in on one and third but by mistake yellow and blue is on 1 and 2 then what will happen?
@@varshaprajapat4646 nothing will happen...but meter reading will be false reading
How to convert a 3 ph 4wire meter into 3ph 3 wire connection please explain
@@biangbornongrum4171 use 2 cts instead of 3
Yo
How much voltages comes at out put end.... If that's is not shown wt the benefit of making video
Dear sir, congratulations on the video. I have LGT8258B Preheating start electronic ballast. So far it has worked with 2 T8 2x58W neon tubes - without starter. Suddenly he started flashing and after 5/10 seconds he was dead. I bought 2 V-TAC LED tubes mod. VT-1577.T8.G13.20W I cut off the power supply on the requested side, after installing nothing to do they don't work. To see if the ballast is working, what voltage or current should I find in the output terminal block that powers the tubes? Thank you, thank you very much. Can you help me, thanks.
CT meter,
Just to be clear there wasn’t no lightning strike…. R/clickbait
Thank you sir for your videos, always something to learn from you.
Why don't you have safety equipment?
Yes we do have
@@electricalengineeringinrea5338ok then why don’t you use it.
@@electricalengineeringinrea5338 No you dont bro
safety flip flops
@@jotreitz Lmao I just sat on my ass for 1 minute laughing
Hello Sir, how do you clean them ? I would like if you can explain it, as I am a studying electrical engineer and want to work in the field.
Just clean with Transformer oil.
Is there a way you can tighten or loosen up the reading?
I dont get u
Sir Did you top up the gas, afterwards, during charged condition?. Helpful sir thank you. Make some more video on scheme diagrams and fault clearing practical secessions
Thank you Sir. I'm wondering why the radiators are separated from the main tanks.
To allow better circulation of oil.
@@electricalengineeringinrea5338 ok sir, I like your detailed explanations. I want to learn more on transformers, switchgear , reactors, NER, protection of power systems, specifications for electrical equipments. Thank you sir
@@noelfaithfulkari2857 good
@@electricalengineeringinrea5338 I've subscribed to your channel to learn more
It's for measurements and for protection right??.
Yes...but in LT, they are used only for measurement...
Thanks alot.
Plllzzz share pdf drawing
U can top up during charged condition also...but u have to off the dc supply to gas compartments
Plllzzzzzz sir share pdf drawing..
Sharing???
😥 Promo sm
Fascinating electricity video but why is there such an alarming lack of safety equipment and personal protective equipment no hard hats being worn and no protective footwear or any other personal protective equipment that I can see
Sir can I have your phone no please.....
Why is this on my feed
itni late kyu upload kara bhai
Why was this suggested to me?😅
Maal he isliye
2012 graduated video 2024 mein kese ?
✨️Nostalgic✨️
Wah what a quality I salute you 🫡
Yeh sab bhai log kya kar rahe honge 🤔
Who's watching in 2024 👍
You
Funfact posted in 2024😂
Technology was limited, no wars,no insta, moderate inflation. People uses to talk to each other than texting on WhatsApp. Life was good ❤
no eletrical explosion
Sir, if i remove generating Transformers soild nutral ground, than how to block fault current, vactor group YDn1
Fault current cannot be limited beyond a certain limit...if we remove solid grounding then return fault current will be routed through neutral of transformer....it will affect the transformer then
N g r earthing two earthpipe used
Yes, one is for on service, the other is during maintenance of reactor...to ground the main reactor
Sir supply .and errection and electric earthing material and civil total project and power tran s for mer and line work pls call me
Sure....
Sir please make a video how to start drop out fuse horn gap fuse air break switch selling business and which department buy this product
Sorry, im specialized in Power system...power substation
Stay safe.
Phi sah shaei bro 👍👍
Mawlai