Daikin VRV Commissioning Tips & Tricks Part 2 | Addressing & Field Settings - 9-10-2022
Timestamps:
Video Notes @ 01:16
Nav Controller @ 02:35
Madoka Controller @ 14:39
Daikin One Smart Thermostat @ 21:08
In this video we'll be wrapping up the Tips and Tricks series with a video on addressing equipment and setting the field settings. The goal of this video is not to give you the list of settings to program but rather give you some tips to make the programming process go smoother.
I will be discussing how to set Group Addresses, Indoor Unit Airnet Addresses, and Field Settings on 3 of Daikin's most commonly used controller types - The Navigation Remote Controller, The Daikin Madoka Controller, and the Daikin One Smart Thermostat.
Brand NEW to the Channel we finally have Super Thanks!!! If you find this video helpful and would like to send support over, click that Super Thanks button under the Video Description and choose the amount you'd like to send my way. I greatly appreciate it plus it's a great way to say thanks without having to become a member!
Speaking of Members...
Support the channel by becoming a Member today!
Multiple member tiers are available which all receive exclusive perks and features, plus early access to videos and much more!
Click the link below or simply click on Join from the main channel page:
ua-cam.com/channels/t7AJsCk99vryPxL1LwJguA.htmljoin
Merch Store - Coming Soon!
You can also support the channel directly through PayPal @InverterAlways
Follow me on Twitter @InverterAlways
I appreciate all your support and hope you find the content helpful!
Thanks for tuning in and watching Inverter Always, I hope you all have an awesome day!
Disclaimer:
All content, material and commentary in this video and on this channel is my sole opinion and perspective only. None of my content is approved as Factory Authorized Training, nor training of any kind. Always refer to the installation manuals shipped with equipment and contact the factory or local technical support of the vendor in the event of needed support.
The content on this channel is for educational and entertainment purposes only and may be incorrect or outdated at any time. It is the sole responsibility of the viewer to do the proper research before designing, sizing, installing or servicing any equipment. Always refer to a local professional for additional support.
As I've mentioned many times on this channel, I am just a guy on youtube sharing my thoughts and experience with you all to best spread knowledge of Inverter Technology to the World.
#Daikin
#VRV
#Inverter
Music via Streambeats.com
Переглядів: 4 776

Відео

Daikin VRV Commissioning | Tips and Tricks Part 1 | Power-up and Test Operation - 9-3-2022
Переглядів 8 тис.2 роки тому
Timestamps: Before You Power On Equipment @ 02:09 Powering up the Indoor Equipment @ 03:04 Powering up Branch Selector Boxes on Heat Recovery Systems @ 04:24 Powering up Outdoor Units @ 05:56 Error Codes during Power-up @ 10:30 Verifying Proper Communication with Indoor Units @ 11:23 Verifying Proper Communication with Branch Selector Box Ports @ 15:24 Forced Fan Diagnostic @ 17:09 Additional R...
Daikin VRV PRE-Commissioning Tips & Tricks | Things to Look Out for, Make Sure YOU Do THIS 8-27-2022
Переглядів 1,9 тис.2 роки тому
In this video we'll be discussing the important things to check for BEFORE you commence power-up and start-up/commissioning of a Daikin VRV System. There are lots of things that can go wrong that will cost you a lot of money when a VRV System fails. Make sure you're following the proper procedures to ensure a proper installation of equipment. Here are a few things I commonly see go wrong that k...
Daikin VRV Installation | Tips and Tricks and Things to Look Out For! | 8-20-2022
Переглядів 1,9 тис.2 роки тому
In this video I wanted to share with you all some tips and tricks and things to look out for when installing VRV equipment. A lot of these things can be transferred to other brands of equipment (generic things to consider when installing VRF), while a few of them are very much directly related to Daikin rules to follow. Hope you all enjoy the video. Brand NEW to the Channel we finally have Supe...
VRF Pipe Sizing MUSTS | Importance of Proper As-built Lengths and Sizes 7-30-2022
Переглядів 2,4 тис.2 роки тому
I hadn't planned on making this video this weekend but along came a spider this week that spun a web of chaos on a project - and I think this is a good lesson for everyone to learn. I cannot express just how important it is, that you need to follow the piping schematics during install, you need to get the sizes and lengths correct and accurate. Otherwise you will have problems, period. Brand NE...
Daikin Hero Simple Edge "Introduction DEEP DIVE" | Daikin CLOUD Monitoring!!! 6-11-2022
Переглядів 9212 роки тому
Hi Everyone, This video is a little longer than usual because I have so much information to provide you all with. Stick around for the whole thing if you can because we'll be taking a deep dive into what the Daikin Hero Simple Edge is and how it works - plus all the cool stuff available that changes EVERYTHING! Thanks Everyone, hope you enjoy the video. Brand NEW to the Channel we finally have ...
Daikin VRV Condensate Alarm | A3 and AF Error Codes - 4-17-2022
Переглядів 2,5 тис.2 роки тому
Sorry for the short video, my allergies have been kicking my butt, and with Easter Weekend in full swing the house is crazy right now. In this video I'll be discussing some common A3 errors that seem to happen a lot (especially lately). Most of the time it's one of two things, it's a fairly simple one to diagnose, and hopefully you aren't dealing with an AF - that one is always installation rel...
Daikin VRV Branch Box Settings | How to set Dip Switches on Daikin VRV Branch Boxes - 4-3-2022
Переглядів 7 тис.2 роки тому
Timestamps: • Branch Box Sizing and Board Configuration Overview @ 01:49 • Disabling Unused Ports @ 04:48 • Ghost Ports @ 10:57 • Twinning Ports @ 13:08 At 12:32 in the video when discussing ghost ports, I circled the wrong port on screen during editing, sorry. If you listen carefully I tell you the correct port, DS2 switch 4 on the right hand board, but I had a case of the Sunday's and didn't ...
HELP!!! Most Common Daikin VRV Start-up Errors 3-27-2022
Переглядів 6 тис.2 роки тому
Timestamps: • U1 @ 01:09 • UA-53 @ 03:01 • U4 @ 10:01 • UF @ 14:15 In today's video we'll discuss some of the most common error codes that show up during a Daikin VRV Start-up. You might be wondering where the U3 code is, I did a special dedicated video just for that in a previous video, here is the link. ua-cam.com/video/DeS_pZgk5BQ/v-deo.html I am constantly receiving calls when folks are try...
Daikin ITM Airnet Engineering Tool | Export Run Time & 24-7-365 Factory Monitoring - 12-24-2021
Переглядів 8132 роки тому
Timestamps: Before you Begin @ 01:00 Airnet Engineering Tool Commissioning Wizard @ 03:35 In this video we conclude the series by programming something on the back-end of the ITM using the Airnet Engineering Tool. This tool allows the ITM to export up to 5 days of performance data. This is a huge help when there's an issue on the job, it reduces service diagnostic time and can help the technici...
Daikin ITM Interlocks | Setting up Interlock Functions on the Daikin Central Controller - 12-24-2021
Переглядів 8722 роки тому
Timestamps: Setting up an Interlock 1 @ 01:41 Setting up an Interlock 2 @ 11:06 In this video we'll be setting up some Interlocks through the Daikin ITM Interlock Function Menu Option. This is a really handy feature when you need to monitor/control 3rd-party points and/or configure Daikin equipment to work in conjunction with other devices. In this video we set up 2 example interlocks. Your app...
Daikin ITM Wago Installation & Setup | Basic Input-Output Module - 12-24-2021
Переглядів 1,8 тис.2 роки тому
Timestamps: Wago Setup Prep - Points Creation Wizard @ 00:50 Programming Wago Points into the ITM @ 12:40 In this video we'll be discussing one of the coolest 3rd-party accessories that can directly integrate into the Daikin ITM without additional controls like BACnet required. The WAGO is a basic input/output module that allows the ITM to monitor and control 3rd-party devices. In this video we...
Daikin ITM BACnet Server Setup - 12-24-2021 [NOT the BACnet Client LOL]
Переглядів 2,4 тис.2 роки тому
Timestamps: Preparing Indoor Unit BACnet Data (Device Instance Numbers) @ 01:05 Exporting BACnet Spreadsheet for Programming @ 03:26 Programming BACnet Client Worksheet @ 04:17 Points List Discussion @ 06:38 Uploading BACnet Worksheet to ITM @ 13:33 Important BACnet License Information @ 14:50 In this video we'll be discussing how to setup the BACnet Server for the Daikin ITM. The BACnet Server...
Daikin ITM Web and Remote Access | Setting up the Daikin Central Controller Networking - 12-24-2021
Переглядів 3,6 тис.2 роки тому
Timestamps: Network Access Setup @ 00:36 Network Login Setup @ 04:10 Login Example and Concluding Discussion @ 06:28 In this quick video we'll go through setting up the ITM for local network access and remote access. Pretty simple video this time around, hope this helps you all out. Support the channel by becoming a Member today! Multiple member tiers are available which all receive exclusive p...
Daikin ITM Schedules | Setting up Schedules on the Daikin ITM Central Controller - 12-24-2021
Переглядів 1,9 тис.2 роки тому
Timestamps: Before you Schedule @ 00:34 Creating a Dual Setpoint Schedule @ 02:46 Creating a Single Setpoint Schedule @ 12:33 Concluding Notes and Discussion @ 17:02 In this video we'll be discussing how to setup schedules on the Daikin ITM Central Controller. This is a basic schedule setup with 2 actions per day. There are many ways to do this, always refer to the application that you're worki...
How to Use the Daikin ITM Central Controller | The Ultimate Daikin ITM User Guide - 12-24-2021
Переглядів 4 тис.2 роки тому
How to Use the Daikin ITM Central Controller | The Ultimate Daikin ITM User Guide - 12-24-2021
Daikin ITM Setup Part 2 | Menu-Icon Walkthrough and Finishing the Programming Process - 12-24-2021
Переглядів 3,8 тис.2 роки тому
Daikin ITM Setup Part 2 | Menu-Icon Walkthrough and Finishing the Programming Process - 12-24-2021
Daikin ITM Setup Part 1 | Programming Management Points (Units) into the ITM - 12-24-2021
Переглядів 8 тис.2 роки тому
Daikin ITM Setup Part 1 | Programming Management Points (Units) into the ITM - 12-24-2021
Daikin U3 Error Code | Tough Love | Winter Tips to Keep YOU Warm - 1-1-2022
Переглядів 3,9 тис.2 роки тому
Daikin U3 Error Code | Tough Love | Winter Tips to Keep YOU Warm - 1-1-2022
Daikin ITM Central Controller | Intelligent Touch Manager Intro-Power-Software Install - 12-24-2021
Переглядів 11 тис.2 роки тому
Daikin ITM Central Controller | Intelligent Touch Manager Intro-Power-Software Install - 12-24-2021
Daikin Back-up Heat Field Settings YOU NEED TO PAY ATTENTION TO on VRVS/VRV Life - 12-23-2021
Переглядів 1,5 тис.2 роки тому
Daikin Back-up Heat Field Settings YOU NEED TO PAY ATTENTION TO on VRVS/VRV Life - 12-23-2021
How to Open ALL the Valves on Daikin VRV | Refrigerant Recovery & Evacuation Mode - 12-17-2021
Переглядів 6 тис.2 роки тому
How to Open ALL the Valves on Daikin VRV | Refrigerant Recovery & Evacuation Mode - 12-17-2021
Daikin VRV Field Settings | Recommended Settings for Residential VRVS & VRV Life Systems 12-10-2021
Переглядів 4,3 тис.2 роки тому
Daikin VRV Field Settings | Recommended Settings for Residential VRVS & VRV Life Systems 12-10-2021
Channel Membership is LIVE!
Переглядів 6462 роки тому
Channel Membership is LIVE!
Daikin Nav Controller (BRC1E) Master Controller | Setting & Changing Master Controller - 12-3-2021
Переглядів 7 тис.2 роки тому
Daikin Nav Controller (BRC1E) Master Controller | Setting & Changing Master Controller - 12-3-2021
Daikin VRVS/VRV Life Test Operation | Daikin VRVS Install & Commissioning Series Ep.11 - 11-26-2021
Переглядів 3,5 тис.2 роки тому
Daikin VRVS/VRV Life Test Operation | Daikin VRVS Install & Commissioning Series Ep.11 - 11-26-2021
Forced Fan ON & Resetting Addresses on Daikin VRVS (Quick Troubleshooting) | VRVS Startup 11-19-2021
Переглядів 4,9 тис.2 роки тому
Forced Fan ON & Resetting Addresses on Daikin VRVS (Quick Troubleshooting) | VRVS Startup 11-19-2021
VRVS Start-up Steps 1 & 2 | Proper Power-up Process & Verifying Communication - 11-12-2021
Переглядів 4,5 тис.2 роки тому
VRVS Start-up Steps 1 & 2 | Proper Power-up Process & Verifying Communication - 11-12-2021
How to Use VRVS Outdoor Buttons | VRVS Install & Commissioning Series Ep.8 - 11-5-2021
Переглядів 5 тис.2 роки тому
How to Use VRVS Outdoor Buttons | VRVS Install & Commissioning Series Ep.8 - 11-5-2021
How to read Daikin VRV LED Lights on Outdoor Units - VRVS Install & Commissioning Series 10-29-2021
Переглядів 5 тис.2 роки тому
How to read Daikin VRV LED Lights on Outdoor Units - VRVS Install & Commissioning Series 10-29-2021

КОМЕНТАРІ

  • @davecoolaircon
    @davecoolaircon 23 години тому

    👍

  • @thecoolguy23
    @thecoolguy23 День тому

    So for the high voltage on indoor units if i have only one breaker how i power the rest of the indoor units? Daysi chain too? Im installing a 4 head vrv and i was going to run independent line for each into a secondary panel with 4 15amp breaker

  • @bjaquez27
    @bjaquez27 4 дні тому

    Can we just make the ITM to be a view only option. I know there’s a Master/Slave switch on the itm. If I do this, would it just eliminate auto from the ITM. I think it just make sense to allow the BRC to do the Auto feature and show the differential at the BrC. I understand using the settings but the end user always ends up changing them regardless.

  • @melakukassye1789
    @melakukassye1789 6 днів тому

    How can we make correct setting of DIP switch for this specified model?

  • @melakukassye1789
    @melakukassye1789 6 днів тому

    Dear Dana i hope you're doing well ! I am one of your channel follower and a fan. Firstly, i am really greatful about you kind support ! You also helped me out before. I also need your support now. On the Daikin VRV III ...Unit model RXYQ-P9W1B, i was replacing a faulty main pc board. After i did the rewiring and plugged all terminals, when i start the unit it show PJ alarm on the remote diaplay. When i check for the PJ error code It is for 'Faulty field setting after replacing main pc board' Can you please support me on how to configure the new board or can you share me a service manual for the configuration procedure, i couldn't find a right service manual for my specific model on the daikin official website. Thanks, Melaku

  • @SRI-il2wu
    @SRI-il2wu 9 днів тому

    Bro I need VRV X commissing

  • @chokolatt8803
    @chokolatt8803 9 днів тому

    I just started learning VRV/VRF systems and your video has the best explanation for Daikin VRV's important settings so far. Thanks a lot and you really earned a like and a subscribe.

  • @VincentLamantia-z7w
    @VincentLamantia-z7w 10 днів тому

    Want videos on trouble shooting mini splits by daikin

    • @VincentLamantia-z7w
      @VincentLamantia-z7w 2 дні тому

      Have a RZQ18PVJU9. Where’s the S2 connector located.don’t see it and the small board has no additional connection places. Please respond

  • @hamitavcoglu9813
    @hamitavcoglu9813 10 днів тому

    Hi, Dana. I have a new question about ITM) Can we actually connect 2 pcs. ITM to each other and use webserver to show all the indoor units which connected to both itm ? If its possible are we using D+ D- plus adp terminals ?

  • @carolgirard3158
    @carolgirard3158 15 днів тому

    Blah blah blah. Just want to k ow how to turn on ac and the dan.

  • @hamitavcoglu9813
    @hamitavcoglu9813 20 днів тому

    Hello colleague, i got a error message from out itm. Shows ''A system error has occurred, and “In safe mode SD card failure” and an error dialog are displayed.'' this error. what can i do ? and why this error can occur ? Thanks.

    • @InverterAlways
      @InverterAlways 18 днів тому

      Kill power. Remove flash card from back. Re install flash card. Apply power. Sometimes they come loose. Hopefully that resolves your issue.

    • @hamitavcoglu9813
      @hamitavcoglu9813 18 днів тому

      @@InverterAlways thx Mr. Dana, i will try

  • @alichtman
    @alichtman 23 дні тому

    Hi Dana. I saw your daikin VRV self test clip and I have the following question: I worked today on my home daikin VRV unit to reset an E3 fault (was due to power outage) and then started a test run which I did not complete (took too long and actually is not really needed as I did reset the E3 fault). Now all units are working fine but I have U3 displayed on the indoor units. What would be the easiest and quickest way to eliminate the U3 ? Will total reset (20 sec) do the trick? If not - I understand that there is a "quick test" mode which takes much less time than the 30-45 minute full test - what is the sequence to activate this "quick test" mode, and will that be sufficient to eliminate the U3? Thanks very much, Arik Lichtman

    • @InverterAlways
      @InverterAlways 18 днів тому

      Did you replace outdoor board? If you have a flashing green light on nav with active u3 just run the test from outdoor and let it complete. Easiest way. If the nav green light isn't blinking then your code is just an old code probably stored in nav.

    • @alichtman
      @alichtman 17 днів тому

      Thanks for the reply. Yes the green light was blinking. No, I did not replace anything. I did run the test but after one hour and twenty minutes I stopped it because it was much longer than the quoted 30-45 minutes. I finally had a technician come here. He initiated a SHORT COMMUNICATION TEST, that apparently exists (only tests comm from external unit to the indoor ones). This took just 10-15 minutes and once it ended - the U3 error was gone. He used just 2-3 clicks to initiate this "Short Test". Do you know what click sequence it is? It may come handy if I get the U3 error again in the future

    • @InverterAlways
      @InverterAlways 17 днів тому

      Hm... not sure what sort of short test he would have been running other than just resetting the internal addressing. Interesting. I'll have to look into this.

  • @computertech9032
    @computertech9032 23 дні тому

    Sir translate in hindi

  • @عبدالمجيدالعك
    @عبدالمجيدالعك Місяць тому

    huge effort are paid from you thank you from Syria

  • @clarkdimla1628
    @clarkdimla1628 Місяць тому

    Hi Dana, greetings, just want to ask if upon using the ITM maintenance mode, will the system still produce the U4-01 error if the indoor power breaker is turned off but it is in maintenance mode? also what is the main purpose of maintenance mode

    • @InverterAlways
      @InverterAlways Місяць тому

      Funny you should ask. I never use maintenance mode. I'm pretty sure you'll still get an error. The only reason from my understanding is to show its in a maintenance mode so users don't get confused when it errors. I would have to intentionally throw some units in and play with it a bit to refresh my memory. 1,000 itm controllers and counting, zero times used it on a job site lol.

    • @clarkdimla1628
      @clarkdimla1628 Місяць тому

      @@InverterAlways Thanks for the response. Hoping to get a feedback whenever you try it. Thank you for your videos.

  • @عبدالمجيدالعك
    @عبدالمجيدالعك Місяць тому

    Hallow it's abdulmjed from Syria and I'm really interested in vrv system, i have a question could any inverter split unit work on vrv odu? and thanks a million for all this effort it's really useful.

  • @mustafaelhaddad3193
    @mustafaelhaddad3193 Місяць тому

    Hello, the air conditioning symbol does not appear when programming the remote control, i.e. it gives all the options except the air conditioning symbol. Why?

  • @octavcotet8832
    @octavcotet8832 Місяць тому

    Great video!Many thanks

  • @shamsheralam8862
    @shamsheralam8862 Місяць тому

    Great, answer..starinded wire for comm wiring

  • @shamsheralam8862
    @shamsheralam8862 Місяць тому

    Answer: nitrogen purging...but at what pressure?

  • @Josaysahn3409
    @Josaysahn3409 Місяць тому

    VRV IV compressor replacement.

  • @rideordie3390
    @rideordie3390 Місяць тому

    Any idea why my mode 20 comes up as 2-02 as factory and not 2-01 like the manual says?

    • @InverterAlways
      @InverterAlways Місяць тому

      Yes, some indoor models default to return air for control out of the box. Most default to 01. And fxtq defaults to 03.

  • @ryanhamstra49
    @ryanhamstra49 Місяць тому

    Hey Dana, is there any talk of a Hero that can do an entire bank of outdoor units instead of just one to one? We have the job you worked with us on where we have 7 systems, it would be nice if we didn’t have to buy 7 of them.

    • @InverterAlways
      @InverterAlways Місяць тому

      Hero pro, coming probably end of year at this point. It's behind schedule but doing some testing on it. Hope you've been well!!

  • @shamsheralam8862
    @shamsheralam8862 Місяць тому

    Thanks for very informative videos, please make vedioes on how to do pressure testing and vaccuming..and also on electrical connection from I/d to u/d unit

  • @JustinBright-u9p
    @JustinBright-u9p Місяць тому

    valves are way cheaper than recovering and pulling a vacuum to replace a leaky coil

  • @shamsheralam8862
    @shamsheralam8862 Місяць тому

    Great thanks very informative

  • @shamsheralam8862
    @shamsheralam8862 Місяць тому

    Great, thanks for sharing... please make more such vedioes...Ans for the question...Mode button.

  • @RichTincher
    @RichTincher Місяць тому

    Thanks for the video. You mentioned the ITM requires a unique network number. Did you mean it requires a unique Device ID? It seems to me all devices in a group would belong to the same bacnet network.

    • @InverterAlways
      @InverterAlways Місяць тому

      The itm itself needs a unique network number, I usually use 100 as a default these days but it just has to be unique to the itm. The itm also needs a unique decide instance number, as do all your indoors and outdoors on the spreadsheet. I believe yes, you're right, they are on the same network from the itm perspective and ip/subnet, but the itm needs a network number. It's default is 53 so sometimes that might work and folks just don't realize it was a thing maybe.

  • @lorettaearle3362
    @lorettaearle3362 Місяць тому

    Thank you! I've just had an ASHP system installed but wasn't given any instruction on how to operate the system. The wifi card wasn't installed so I couldn't connect to the app but I hope that will be resolved later today when a Daikin engineer is due to visit. Thanks to your videos I now have a better understanding of what I'll be able to do when the system is finally set up properly. It's particularly good when you show that things don't always work as expected. 🙂

    • @InverterAlways
      @InverterAlways Місяць тому

      The madoka never works as expected lol.. kidding, not kidding. It's cool, just has some quirks.

  • @tonymilligan4086
    @tonymilligan4086 Місяць тому

    How do you assign it as the master controller i.e. cooling/heating masterhood?

    • @InverterAlways
      @InverterAlways Місяць тому

      It's in the settings menu you have to select it as master.

  • @ltxchuyin9219
    @ltxchuyin9219 Місяць тому

    Thanks for your videos dana I’m new to vrvs but are helping me out a lot , I was wondering when adding refrigerant to a new vrv and new piping am I supposed to have the service valve closed ? Or open or should I add the refrigerant with the valves closed then open them up then set it into test more ???

    • @InverterAlways
      @InverterAlways Місяць тому

      I prefer to use the vacuum the line set is in when I'm done evacuating, it pulls in the charge. On a new install your outdoor service ports are closed at this stage. Add charge. Then open service valves. Then go through power up procedures.

  • @ricks3469
    @ricks3469 2 місяці тому

    Hey Dana, Four years ago, I chose a Daikin inverter system, RMXS 48LVJU, two branch boxes, three indoor units each. This is a residential install. Overall been extremely happy, but I’ve had some unexplained issues, would like some guidance. • at 18 months after install an unexpected high pressure rupture at an elbow inside the outdoor unit. Total loss replaced by my installer and Daikin. • over next 12 months recurring F3 and F5 faults. Installed a recorder to gather data, installer sent to Daikin engineering. Communicated over the next 3 to 6 months. Determination was overcharged, directed to release a half pound at the time until system stabilizes. That seem to occur with the last release being September 23, 2023. • through fall and winter system operated very well with occasional A5 fault showing up. • June 2024 and 100 degree days, air conditioning was not performing as previous three summers. Would not hold temp anywhere close to desire. Installer came out evacuated refrigerant to determine current charge and compared to design of 7.77 pound requirement. Almost exact. • he has stated, and I agree that he has reached his limit of knowledge of the systems, and the study of data acquired. I am currently recording data. • my ask is, can you advise on someone to at least look at the data recordings, and have some conversation to see if there’s a path forward that is realistic. And I know nobody works for free!!!!!

  • @TheMontyferdowsi
    @TheMontyferdowsi 2 місяці тому

    do you guys provide paid support services on Daikin VRV?

    • @InverterAlways
      @InverterAlways 2 місяці тому

      Well, sort of. I haven't charged anyone yet on the channel. But folks have sent complimentary donations for my helpful commentary when it has been helpful for them. What do you have going on? The whole point of the channel is to help folks learn so if I can help I will.

  • @suhailalvi3545
    @suhailalvi3545 2 місяці тому

    Dear Dana, How to stop setback setting in Daikin ITM. I removed setback from the unit but it is coming back.

    • @InverterAlways
      @InverterAlways 2 місяці тому

      Setback can be disabled on the main screen by clicking settings. Make sure your units are selected first because the settings you change will only affect the selected unit or layer/group. Also keep in mind that you will need to check any schedules that have it programmed and disable in the schedule. Also if you are using itm bacnet server the bacnet side may re-enable it by setting the units to unoccupied mode. Unfortunately one of daikins biggest bacnet flaws is how they handle on/off. Since there is no simple on/off command in the bacnet software, setting a unit to unoccupied will shut it off and enable setback simultaneously. I always try to tell the integrator to keep the unit in occupied mode and just change occupied setpoints for daytime and nighttime schedules.

  • @JoelNove
    @JoelNove 2 місяці тому

    Thank you for the video. Did you tuck the WiFi adapter in the unit side part or does the adapter stay outside of the unit? Thanks!

    • @InverterAlways
      @InverterAlways 2 місяці тому

      I've seen folks tuck it inside but depending on the install you may not have room. On wall heads I just set it on top usually, unless there's an end user who has an issue with that then you need to get creative. Keep in mind tucking it inside something may affect it's connection strength too though.

    • @JoelNove
      @JoelNove 2 місяці тому

      @@InverterAlways awesome. That makes sense. Thanks! Turns out I got the wrong WiFi adapter. I have a Daikin Inverter but can’t seem to find the right item on Amazon? Any suggestion where to buy it online?

  • @polpatrol1
    @polpatrol1 2 місяці тому

    Hello, How do i get the 'Operation Data Export' logo on the iTM?

    • @InverterAlways
      @InverterAlways 2 місяці тому

      You will need to run the airnet engineering tool to allow the itm to provide operation data (performance data). If you don't do this then clicking data export only gives you things like on/off and setpoint changes. The icon should populate by default if you have some of the latest versions 2.06 I think or later. I can't remember if earlier versions had it.

    • @polpatrol1
      @polpatrol1 2 місяці тому

      @@InverterAlways thx allot for your answer. European market here.

  • @justinlynch6691
    @justinlynch6691 2 місяці тому

    Daikin software is beyond hot garbage. It is completely unintuitive, needlessly cryptic, Bluetooth is incredibly unstable, they don't have wireless ota updates, almost $500 for a thermostat and controller that can't even connect to WiFi. If they weren't good at refrigeration this would be criminal. I wouldn't wish this dumpster fire on my worst enemy.

    • @InverterAlways
      @InverterAlways 2 місяці тому

      Should not be spending 500 bucks on madoka. Not even close. It's not advertised as a wifi option either. If you want wifi go daikin One Touch, it's closer to 500 but has all the goods if that's what you need. Otherwise if you just want wifi use a dkn adaptor with a regular nav and you're good to go.

    • @justinlynch6691
      @justinlynch6691 2 місяці тому

      @@InverterAlways it was $465 CAD plus tax (15%). I know what it's advertised as. I used to design electronics and write firmware both embedded Linux (yocto) and CMSIS-ROTS2. I just know for that price what it should be. I'm ok with it being not good and affordable but that price is absolutely insane. Couple that with the installer lockouts, anti right to repair. I couldn't even set it to use my thermostat instead of return air thermistor without having a friend who was a tech and told me the magic words. A company this big with this kind of engineering department putting out this for the price they do, and calling it award winning is embarrassing.

  • @greglauer3576
    @greglauer3576 2 місяці тому

    Glad your back Dana

    • @InverterAlways
      @InverterAlways 2 місяці тому

      Thank you. Glad to be back, but I am itching to post new content. Hopefully soon.

  • @bebitonenita65
    @bebitonenita65 2 місяці тому

    Thank you - it helped !!

  • @jchabs111
    @jchabs111 2 місяці тому

    Any info on why indoor unit won’t connect to airzone WiFi adapter?????

    • @InverterAlways
      @InverterAlways 2 місяці тому

      A variety of reasons, plugged in/wired wrong, incompatible unit, issue with device or indoor board, incorrect setup, sorry there's a lot of potential reasons. Kill power check all connections, power back up the unit. Make sure indoor and outdoor talk, then use your phone app to connect to the adaptor and go through setup process.

  • @Drocka69
    @Drocka69 2 місяці тому

    How do you adjust the fan speed?

    • @InverterAlways
      @InverterAlways 2 місяці тому

      In the settings, or you can touch the airflow icon on main screen and get to it from there as well.

  • @tombudington5255
    @tombudington5255 2 місяці тому

    I have a 6 port Branch Box A-B ,C-D are twin pipe together E is straight Piped F is not begin used I have 2 Boards how do I set my dip switches Left board DS-1 DS-2 Right board DS-1. DS-2 I would appreciate any help !

    • @InverterAlways
      @InverterAlways 2 місяці тому

      Left board ds2 switches 1 and 2 on. Right board ds1 switch 2 on, ds2 switch 4 on.

  • @Jonathan-li1xh
    @Jonathan-li1xh 2 місяці тому

    Dana , I am a big fan of your videos and the quality of the contents . Missing new videos and hopefully you will return with new videos .

    • @InverterAlways
      @InverterAlways 2 місяці тому

      I'll be back, at some point. I miss posting. I appreciste the support!!!

  • @tharonlynnn1430
    @tharonlynnn1430 2 місяці тому

    These things are junk lol half the time they don’t have parts but we shouldn’t need parts for something that is a few months old I hope we stop selling these

    • @InverterAlways
      @InverterAlways 2 місяці тому

      A system is only as good as it's install. When installed correctly most systems out there operate pretty well. There's very few brands that just have plain crap equipment. Based on the over decade now working on daikin I would confidentially say, compared to other brands Daikin has a very good quality of equipment. I would challenge and encourage you to get all your guys properly trained on the installation of these systems, and it would also be good to get good service training. Lots of trainings out there that don't really do a good job of covering the details. Everything mechanical will break at some point and although Daikin may not always have an available spare part locally for you, they do a pretty good job of keeping them stocked at the factory for the most part. But in some cases when a part is not available, I agree it can be frustrating. That doesn't make a brand junk though. Just my thoughts. Any time a unit is having issues or if you or a team member is having a challenge with a series of units it is always good to step back and try to determine the root cause of the issue. Over 95% of issues come down to the installation of a unit. It's rarely just a bad unit. I'm sure this doesn't help you but I always try not to just blame the equipment and instead look deeper into the causes of failures and issues.

  • @benharris2051
    @benharris2051 3 місяці тому

    Did you ever get an answer from them about locking it out and losing Bluetooth connection? I accidentally function locked the RC fro the app. Now it won’t let me put it in pairing mode to change it, is there a manual reset of the controller? Thanks for the video!

    • @InverterAlways
      @InverterAlways 2 місяці тому

      I am not aware of a manual reset. If you walk up to the controller though and try to reconnect from the app will it not reconnect? I've noticed in the past, though it's been a while, that once you make that first connection you can just walk up to it and reconnect. Maybe that doesn't work anymore.

  • @benharris2051
    @benharris2051 3 місяці тому

    I accidentally function locked the RC fro the app. Now it won’t let me put it in pairing mode to change it, is there a manual reset of the controller? Thanks for the video!

  • @dishes808
    @dishes808 3 місяці тому

    Thank you for the content IA. Wondering if you can add a commercial inline ceiling exhaust fan, with an EC motor to the iTM? Local rep is quoting me basically a whole control system just for the fan. Almost 8k- parts only. I have plenty of ports available. Are there any add-on pieces I need to integrate a standard EF? Many thanks for the help. - Best

    • @InverterAlways
      @InverterAlways 3 місяці тому

      You can with a wago yes, depending on how much control you need either di/do or ai/ao type contacts may need to be added to the wago.

  • @lukeforeman625
    @lukeforeman625 3 місяці тому

    Can you stack refnets ontop of eachother?

    • @InverterAlways
      @InverterAlways 3 місяці тому

      Sure, if they are flat and level 👍

  •  3 місяці тому

    What controller can I use to act like a nest thermostat, I think this one is fairly useless as you cant set different cooling temps for time of day, home/away functions, or controlling from another location

    • @InverterAlways
      @InverterAlways 3 місяці тому

      The Daikin One has similar features as a nest. But inverter heat pumps are not designed to constantly have different setpoints. Ideally it's most efficient to leave it alone and let it maintain. But if you wanna schedule it to change just use a Daikin One.