Grounding Techniques for Two Wire Decoder Irrigation Systems
The components used in irrigation control systems, particularly those in decoders, are very vulnerable to voltage surges.
Proper grounding is required for any surge protection to work. Good grounding dissipates the surge to a path to ground. The grounding path has less impedance than the path through the irrigation equipment. Redirecting the surge to the ground protects the equipment.
Poor grounding frequently leads to unnecessary component failures, system down time and customer complaints.
Since lightning and surge damage is never covered by manufacturer warranty, it is in the installer’s best interest to follow these guidelines to install the most resilient system.
Several different methods of grounding might be used. This video reviews common techniques and installation methods. For further assistance contact Regency Wire and Cable at www.RegencyWire.com
Переглядів: 6 446

Відео

Proper Wire Splicing for Two Wire Decoder Irrigation Systems
Переглядів 17 тис.4 роки тому
The difference in a decoder-based irrigation system that operates reliably and one that doesn’t is frequently in the quality of the waterproof wire splices. Because of the sensitive electronics used in a decoder system, the smallest short circuits will cause a malfunction. Follow the wire splicing procedures in this video - and the manufacturer’s guidelines - to avoid damage to the system AND t...
Get to Know Regency Wire
Переглядів 2,2 тис.6 років тому
Since 1985 Regency Wire has focused our entire product offering, manufacturing investments and customer support in other words, our entire business around service the needs of America's green industry. Regency means made in America!
Troubleshooting Decoder-Based Irrigation Systems
Переглядів 50 тис.7 років тому
Learn how to troubleshoot basic decoder-based irrigation system problems.
Resolving Specific Decoder-Based Irrigation Control System Problems
Переглядів 27 тис.7 років тому
Know how to resolve various problems that are specific to decoder-based irrigation systems.
Regency Wire Distributor Testimonial
Переглядів 7668 років тому
Wire is an important component to your installation. See how the folks at Regency Wire can help you make your customers happy.
Cómo hacer empalmes a prueba de agua para sistemas de riego
Переглядів 133 тис.9 років тому
En este video, vamos a revisar la manera equivocada y la manera correcta de hacer empalmes eléctricos de irrigación.
Solución de problemas eléctricos en la válvula de riego
Переглядів 173 тис.9 років тому
En este video, vamos a revisar algunos pasos para solucionar eh identificar la causa del problema ye ayudarlo a que lo resuelva.
Solución de problemas de una zona de riego que no se activará
Переглядів 263 тис.9 років тому
En este video, vamos a revisar los pasos para identificar problemas y la causa de una zona que no se activa.
Solving Electrical Problems with an Irrigation Valve
Переглядів 80 тис.9 років тому
In this video, we demonstrate how to check for electrical issues at your irrigation valve. Typically, this can help you avoid replacing equipment and spending more money. Subscribe to our channel for more troubleshooting tips.
How to Make Waterproof Wire Splices for Irrigation Systems
Переглядів 145 тис.9 років тому
See how to create effective, waterproof wire splices perfect for outdoor environments. Subscribe to our channel for more troubleshooting tips.
Troubleshooting an Irrigation Zone that Won't Activate
Переглядів 641 тис.9 років тому
What steps should you take when a zone on a sprinkler system won't turn on from the controller? An irrigation zone that won't activate can be frustrating, but by using the steps in this video you can reduce your stress and easily pinpoint the issue. Subscribe to our channel for more troubleshooting tips.

КОМЕНТАРІ

  • @RealBVR
    @RealBVR 4 місяці тому

    I tested the control panel for incoming AC voltage at the transformer it had the correct amount. Each of my 4 zones do not show any AC power leaving the box. I then tested the solenoids from the box, and they all show they are good (42 Ohms. What does this mean for my system? All the screws for the common and zone wires are secure. Any ideas?

  • @timschmidt3784
    @timschmidt3784 5 місяців тому

    This is a clear, concise video to help diagnose why your sprinkler valve is not operating. I used it to test the controller and the voltage at the valve itself. I determined that the connection of the common wire to two valves was inadequate. I stripped the wires and reconnected them and the problem was fixed! Thank you for an outstanding video!

  • @stephaniea3688
    @stephaniea3688 5 місяців тому

    Thank you!!🎉🎉🎉 I appreciate you

  • @nicolaslsoto
    @nicolaslsoto 5 місяців тому

    What if I hear water sounds and water running through the hoses when I activate my faulty zone, but no sprinkler heads come up and the sounds stop right after?

  • @josephkarl7080
    @josephkarl7080 6 місяців тому

    I have a station that won't work. It is getting power to the solenoid as I can hear it starting but no water... also have another station that won't turn off! Different junction for both (front and backyard are separate).

  • @robertocastaneda6714
    @robertocastaneda6714 11 місяців тому

    👏🏼👏🏼👏🏼👏🏼👏🏼👏🏼👏🏼👏🏼👏🏼👍🏼

  • @cashiousclay8743
    @cashiousclay8743 11 місяців тому

    I’ve been looking for a milliamp clamp meter that’s not over 200$, any suggestions?

  • @stownley2005
    @stownley2005 Рік тому

    What if the volt out put is AC 25.6 and ohms 27.3. However, they valve will not manually turn on at the valve box. The heads pop up try to start then drop back down. Then pop up again trying to start only to drop back down and nothing happens.

  • @brandonepps9984
    @brandonepps9984 Рік тому

    They use 3M Epoxy scotch cast now for splices

  • @robertdaniels1130
    @robertdaniels1130 Рік тому

    I have a Hunter system that was operating find 2 weeks ago... now zones 1, 2, and 3 are functioning as usual, but zones 4, 5, and 6 are not functioning at all. I have water pressure to these zones because I can turn the solenoid 1/4 - 1/2 turn and the problem zones will operate. Interestingly, the 3 zones that are not operating are all on the same power 'terminal strip', while zones 1, 2, and 3 are on a separate 'terminal strip'. I've gone as far as to move the leads from terminal positions 4, 5, and 6 to terminal positions 7, 8, and 9 (the next terminal strip up, and visually completely separate), but the zones are still not operating... even though the controller indicates that they're in operation. I've been through the steps that you demonstrate in your video, but I'm not getting the 20 - 60 ohms on terminal strips (4, 5, 6) or (7, 8, 9). Could both of these terminal strips have gone bad? Any suggestions are appreciated...

  • @teirayo
    @teirayo Рік тому

    Is that Ezreal?

  • @vanwahlgren8451
    @vanwahlgren8451 Рік тому

    Nice

  • @kmacdowe
    @kmacdowe Рік тому

    Nice video, thank you, but it would be great if you specified the part number and model of the connectors you recommended.

  • @ZDevelopers
    @ZDevelopers Рік тому

    Thank you

  • @ROYALFLUSHyyz
    @ROYALFLUSHyyz Рік тому

    Nicely laid out sir, my issue was a short, detected from your resistance test.

  • @st0nedcrusader417
    @st0nedcrusader417 Рік тому

    Push wire ALL THE WAY TO BOTTOM! Half way up can cause it to fail prematurely 👍

  • @r8rfateful2kx
    @r8rfateful2kx Рік тому

    Thanks to your video, I was able to find that my non-working station had an open circuit due to wiring being damaged by the family dog, and re-connected to an open wire that was not in circuit. 30 minutes of troubleshooting and one minute of re-connecting wires, and all stations are running correctly. Thank you so much! 👍

  • @josemartinez-rq9us
    @josemartinez-rq9us Рік тому

    Muy Buen video ...corto y efectivo GRACIAS AMIGO

  • @NotCarlDanger
    @NotCarlDanger Рік тому

    I'm lost for words at how straight to the point you got to each step of the process and how I'm still going to find a way to make this project be the bane of my existence through the weekend. If you see a massive jump in numbers for the views, it's probably just going to be me listening to this in my sleep for the next 4 days. Thanks for your effort in explaining everything like I'm a beginner, not an expert, and it being under 5 minutes to keep my attention. You're a gentlemen and a scholar good sir.

  • @marlenemendezmartinez3351

    Podrás decirme porque una válvula que funcionaba bien ahora ya no tiene precion ? Yo cambie el solenoid y el diagfragma y sigue sin precion

  • @alber_gar
    @alber_gar Рік тому

    Agradezci este video que hizo darme cuenta lo que pasa en mi riego, luego de haber sacado la bomba de agua para repararla, me ayudó a resolver el problema. Gracias.

  • @Massenko
    @Massenko Рік тому

    Hola, que significa la letra “C” al activarse una estación? Me ocurrió que comenzó tarde y con esa letra abajo de la duración

  • @jorgesantana2932
    @jorgesantana2932 Рік тому

    Tengo un sistema(Rainbird ESP-TM2) que se estan quedando todas las valvulas encendidas aun apagando y desconectando el sistema. La unica opcion que me funciona es cerrando la llave de pase de agua. Le ha sucedido a varios vecinoa en la comunidad. Sera que el sistema salio malo de fabrica o problema de instalacion o alguna otra? Ya que dudo que las 4 valvulas esten dañadas.

    • @noeliapasquale3443
      @noeliapasquale3443 Рік тому

      y la bomba no para? O es un sistema común al barrio donde la bomba es externa al domicilio?

    • @jorgesantana2932
      @jorgesantana2932 Рік тому

      @@noeliapasquale3443 hasta que no cierre la llave de paso.

  • @RafaelMartinez-ts8qw
    @RafaelMartinez-ts8qw Рік тому

    Un control I core hunter y un control rainbird pueden trabajar con solo una mastervalve oh tiene que tener una máster valve para cada control? Porque ambos marcan error y no se si sea el problema por la master

  • @carlossantana7487
    @carlossantana7487 Рік тому

    Gracias ❤

  • @edwardchristopher6447
    @edwardchristopher6447 Рік тому

    Good information thanks

  • @enriqueserrano3958
    @enriqueserrano3958 2 роки тому

    riega zona 1. Empieza la 2, a su debido tiempo, la 1 no se cierra estan regando 1y 2 a la vez. Se cierra la 2 y se abre la 3, zona 1 sigue regando. Lo mismo con la 4, es decir 1y 4 riegan a la vez. se apaga la 4. La zona 5 riega con la 1, despues se añaden 6 y 7. Cuando se riega la zona 7 se estan regando 1+5+6+7. Alguien puede decir cual es el problema.

  • @rayg9618
    @rayg9618 2 роки тому

    Great job - very informative and helpful!

  • @AlfredoHernandez-mo5xd
    @AlfredoHernandez-mo5xd 2 роки тому

    Que sucede cuando una válvula se queda un poco abierta y sigue tirando agua o se también abre cuando se abre otra válvula?

  • @truesonofliberty3267
    @truesonofliberty3267 2 роки тому

    You lost me at volt meter....

  • @edgarbernardonavarro7462
    @edgarbernardonavarro7462 2 роки тому

    Saludos buen día una pregunta al encender el control en la zona 1 también se acciona la zona 3

  • @thomasjones-yc8lf
    @thomasjones-yc8lf 2 роки тому

    Very helpful. Tanks

  • @sp00f34
    @sp00f34 2 роки тому

    I hope my comment helps someone. Check the unit! I thought A B C were the zones... but there are ZONES WITHIN ZONES, like A1234, B1234 etc... not just A B C... there are subsets in each letter. TA DA

  • @sethpotter9592
    @sethpotter9592 2 роки тому

    My zone 6 was working fine yesterday after turning on my sprinkler system, but now I have a trickle of water coming out at the sprinkler at the 1st head and nothing else.

  • @richardpaul495
    @richardpaul495 2 роки тому

    i hade 17 volts ,and you are the only one to tell me it a controller,thanks thanks

  • @mrsokool99
    @mrsokool99 2 роки тому

    Very nice video as I was able to figure out my issue with the wiring on one of my zones. Appreciate your time to post this. Thank you.

  • @marcelogarcia7318
    @marcelogarcia7318 2 роки тому

    Buenas tardes, consulta arme un sistema de riego con controlador HUNTER 2 ESTACIONES estaba funcionando correctamente ahora resulta que arranca el primer sector 3 minutos funciona bien y cuando arranca el segundo debería funcionar 3 minutos pero solo funciona 1 minuto 30 para la bomba y me indica que esta regando e inclusive el solenoide llega tensión y a los 15 segundos vuelve a arrancar hasta completar los 3 minutos. Ya probé de todo desde cambio de flotante eléctrico y nada cambio de contactor y nada, puede ser falla del controlador hunter x core nunca me había pasado

  • @arielcastiglioni
    @arielcastiglioni 2 роки тому

    hola tengo el riego activado para unas hora pero pasa que arranca a hora que nunca se progamaro me ayudarian gracia

  • @joseantoniomenchen212
    @joseantoniomenchen212 2 роки тому

    Una pregunta. Los conectores con grasa tienen capacidad para 3 cables. Si tengo 5 electroválvulas, el cable común debo unirlo a 5 cables. ¿ Cómo lo hago ?Gracias

  • @daveinmontana77
    @daveinmontana77 2 роки тому

    Use Splice-Kote Heat Shrink Insulation Sleeves for all electrical connections... RCV's, Decoders, Low Voltage Lighting, Submersible Pumps, Truck, Auto, & Trailer Wiring, etc.

  • @jasonparkinson7621
    @jasonparkinson7621 2 роки тому

    Good video.

  • @gabriellavinsantelices3125
    @gabriellavinsantelices3125 3 роки тому

    Al girar el solenoide un cuarto de vuelta no abre la valvula...que podría estar pasando?!!!

  • @robertbrandywine
    @robertbrandywine 3 роки тому

    I have a Rainbird SST600IN. The voltage across the input wire to the common wire reads 14.5 V until I turn on a valve and then it jumps to 28.5 V. Is this normal? Why is it doing this?

  • @alcantar06
    @alcantar06 3 роки тому

    Hi guys hope someone can help. I have a 2 zone Node. The zone 1 is not activating (run time is OK, checked and confirmed by total run time) however if I start the zone manually it will turn on. Thanks.

  • @williamvergara2326
    @williamvergara2326 3 роки тому

    Hola, a qué le llaman 1, 2, 3 zonas?

    • @sergiopelegriperez8597
      @sergiopelegriperez8597 2 роки тому

      En terrenos grandes se divide en zonas. Primero se riega 1 zona, luego Salta el riego en la 2a zona... Etc

  • @swiftbiscuit455
    @swiftbiscuit455 3 роки тому

    Fixed my sprinkler system in 10 minutes. Thank you for this video.

  • @andytang5187
    @andytang5187 3 роки тому

    Hello there. Just want to share my problem with my sprinkler now. I have a multiple-zone sprinkler and every station is working properly except one. This station will works when you run it manually for “second time”. For example, if you run that station manually the first time, heads will not pop out. Then turn it off and run second time, it will start working. Then, if you turn off it and try to run third time, not working. Basically it’s like one time working and the other will not, looping… Do you have any thoughts what will be problem?

  • @sandhyarajesh2953
    @sandhyarajesh2953 3 роки тому

    Sir while put on the controller to the Run mode, it's shows on display that DEC 24 alarm and other station also... Please tell about it... What is the problem

  • @sprinklerautomation3085
    @sprinklerautomation3085 3 роки тому

    ua-cam.com/video/HEgyyMqn4Jc/v-deo.html

  • @MsGrandunion
    @MsGrandunion 3 роки тому

    Any suggestions for a system that won't launch properly? The first two rotors splutter out water, and the rest do nothing. If I intervene, and pull on the second rotor slightly to help it launch, then the whole system springs into life! I've replaced the second rotor several times, assuming that the fault is in the individual rotor, but the problem persists.