Nissan Pathfinder bulb replacement license plate and backup reverse bulbs 2013 - 2020
Nissan Pathfinder this applies to all the models from 2013 to 2020 How to replace license plate and backup reverse with factory to LED bulbs.
Переглядів: 5 847

Відео

SUMP PUMP how to replace and clean drain tub basin - Troubleshooting SUMP PUMP not working
Переглядів 1832 роки тому
If you are having issue with SUMP PUMP not working, check the power connection, circuit breaker first then test the pump if it is not kicking off. So, If no sound or noise from the pump most likely you need a new one to be replaced. Typically they last 4 to 7 years depending on the maintenance and how hard it has been working. Test your SUMP PUMP every year, with simple 5 gal. bucket of water i...
Furnace Troubleshooting Code 33 and 13 no heat inducer motor wont start
Переглядів 75 тис.6 років тому
You have continues blower motor running no power to the inducer and you're getting a error code 33 which is limit circuit fault and then it goes into code 13 circuit lockout. Check your vents your filter blockage drain any air circulation issues the first thing you should replace in this case rollout switch if it was tested bad with multimeter on ohms setting.

КОМЕНТАРІ

  • @btmauto2459
    @btmauto2459 3 місяці тому

    I changed the rollout switch like you did and it finally fixed the problem for about 1 day. the next day I had a code 33 and 13 again. Do you think it's the heat exchanger that is cracked?

  • @larryyoung7620
    @larryyoung7620 Рік тому

    And

  • @Monarch.One.
    @Monarch.One. 2 роки тому

    Would you kindly tell me the switch name? I have the exact same problem and there are lots of different names for that. HH18HA452 - Carrier OEM Furnace Limit Switch L250 by OEM Replm for Carrier. Is this the right part number? Thank you ahead!

  • @chrissipple1018
    @chrissipple1018 2 роки тому

    please no more day's. Just replace all the parts

  • @centrumsolutions4744
    @centrumsolutions4744 2 роки тому

    The question is why does the switch trip?

  • @coltbennett518
    @coltbennett518 3 роки тому

    If the rollout is going ur flame is lifting off of the heat exchanger, these Bryant, carrier, and Payne products are notorious for having plugged secondary exchangers mainly due to the fact that when installed a lot of them weren’t sloped 1/4” per foot towards the front of the furnace. What scares me is the rust on the bottom of the furnace which he neglected to mention, this will happen when your secondary gets plugged and leaks rust. I pray to god that he has CO detectors in this house or that he got a certified tech to check the exchanger / take a CO reading at the vent. If you have no idea what your doing to tell people online to replace a switch that is tripping which in fact it is something else that is causing that switch to trip. You can be killing people man. BTW I am a gas technician and I work on these products daily

    • @masterofnoneon_call6652
      @masterofnoneon_call6652 2 роки тому

      Yes have the CO detectors all over the house including in the furnace room.

  • @newera4k333
    @newera4k333 3 роки тому

    Thanks for the help. MN resident here as well.

  • @jiismo
    @jiismo 3 роки тому

    You can view the code led through the clear view port on that bottom panel.

  • @williamswan7779
    @williamswan7779 3 роки тому

    thank you it was a big help

  • @khoailam
    @khoailam 3 роки тому

    Thank you for the video

  • @masterofnoneon_call6652
    @masterofnoneon_call6652 4 роки тому

    Thanks for useful comments, I am not a tech this was just an experiment on my own to learn and troubleshoot I have fixed similar issue on a different furnace where I had to replace the switch board which was bad with no power. I only purchased the inducer as an safety net if rollout switch wasn't the cause of this problem in this video. This model has the rollout switch located on the right side across the flame burners. Take all safety measures when dealing with electrical and mechanical components. This video is only for learning and troubleshooting purpose. Thanks for watching!

  • @handsomwhitedevil4213
    @handsomwhitedevil4213 5 років тому

    Why would the flame be rolling out, clogged vent?

    • @heshamos
      @heshamos 3 роки тому

      Clogged vent or more likely clogged exchanger!

  • @smilesmile6309
    @smilesmile6309 5 років тому

    First of all roleout switch is there for a reason. Carrier has history of secondary heat exchanger cracks . If that happens roleout switch goes of . The best way to check is to get it checked by co analyzer . If heat exchanger goes bad u will find crazy smell coming out if exaust pipe which can be detect outside. However if u r not a tech don't fix carrier furnace ur self for they have a bad history on heat secondary exchanger cracks. Don't kill ur self for few bucks

  • @mrgoal522able
    @mrgoal522able 5 років тому

    what was the problem? you bought several parts which one actually fixed it? it was the flame roll out switch?

    • @srmay7587
      @srmay7587 5 років тому

      I'm thinking it was the flame roll out switch.... same issue here and the high limit switch replaced worked fine for a day then code 33 to 13 again now going to replace roll out switch and see if problem persists... stay tuned will comment again soon 👍

    • @masterofnoneon_call6652
      @masterofnoneon_call6652 5 років тому

      Flame rollout switch.

    • @stevecrawford333
      @stevecrawford333 3 роки тому

      @@masterofnoneon_call6652 still working after that?

  • @tracyk3567
    @tracyk3567 5 років тому

    Best video of Bryant code 33 yet! Thank you. Quick question, is the reset button (rollout switch) right there, on the right side or is it inside by the burners?

  • @5822huron
    @5822huron 6 років тому

    Are you a tech? Because you are just buying parts.. you have replaced alot of Shit without testing..lol. I'm a tech

    • @tl2135
      @tl2135 5 років тому

      Ur a tech but looking at his video?? Lol

    • @hardkore360
      @hardkore360 5 років тому

      dude, he saved money and learned some diy skills on his own furnace, he posted to HELP others. whats the problem AND what have you done to HELP humanity?

    • @hardkore360
      @hardkore360 5 років тому

      BTW code 33 has a laundry list of causes that can go wrong, including blower motor and capacitor, he chose to attack the cheaper parts and got it fixed on his own

    • @hardkore360
      @hardkore360 5 років тому

      @@tl2135 he probably wants to learn what the causes of code 33 are and how to fix it, while "fixing" a client's furnace, FML hahahahah a