- 292
- 759 929
HVAC SUPPORT TECHIE
India
Приєднався 31 жов 2019
HI everyone, this is a HVACr related UA-cam channel. where i try to post all my day to day HVAC related video which i troubleshoot .
IF you have any HVAC related issue can comment me i shall help You fixing it , specially.
Chillers
AHU dx type
AHU chilled water
VRFs and VRV
Inverter AC split and central system
package ACs
Hydrogen sensor panel
Auto sequential panel
Fire damper controll panel
Chilled water Actuators and thermostat wiring
AHU starter panels
FAPA interlocking with AHU and Controll panels
Exhaust wet scrubber
exhaust dry scrubber
Walk in chillers
walk in freezer
and more.
For any queries msg on Instagram
IF you have any HVAC related issue can comment me i shall help You fixing it , specially.
Chillers
AHU dx type
AHU chilled water
VRFs and VRV
Inverter AC split and central system
package ACs
Hydrogen sensor panel
Auto sequential panel
Fire damper controll panel
Chilled water Actuators and thermostat wiring
AHU starter panels
FAPA interlocking with AHU and Controll panels
Exhaust wet scrubber
exhaust dry scrubber
Walk in chillers
walk in freezer
and more.
For any queries msg on Instagram
Artic Master / Green Liquid Receiver Tank / liquid Receiver Tank ka video hindi aur urdu mein.
"Arctic Master Liquid Receiver: Efficient Refrigerant Management for HVAC Systems"
*Description:*
"In this video, we take a closer look at the Arctic Master Liquid Receiver, a high-performance refrigerant management solution designed for HVAC systems. With its advanced features and robust construction, the Arctic Master Liquid Receiver provides efficient and reliable refrigerant storage, separation, and flow control.
Key benefits and features:
- High-capacity liquid storage and separation
- Efficient refrigerant flow control and management
- Robust construction with heavy-duty steel and corrosion-resistant coatings
- ASME certification for safety and reliability
- Customizable designs and configurations for specific applications
Whether you're an HVAC professional, engineer, or facility manager, this video provides valuable insights into the Arctic Master Liquid Receiver's capabilities and benefits. Watch to learn more about how this innovative solution can improve your HVAC system's efficiency, reliability, and performance."
*Tags:* Arctic Master, Liquid Receiver, HVAC, Refrigerant Management, ASME Certification, Efficient, Reliable, Robust, High-Performance.
Here are the explanations:
*Vertical Receiver Tank:*
A vertical receiver tank is a type of liquid receiver tank that is installed vertically, with the inlet and outlet connections typically located at the top and bottom of the tank, respectively.
In a vertical receiver tank:
- The refrigerant enters the tank through the inlet connection at the top.
- The liquid refrigerant settles at the bottom of the tank due to gravity.
- The vapor refrigerant remains at the top of the tank.
- The outlet connection at the bottom of the tank allows the liquid refrigerant to flow out of the tank.
*Whirlpool (or Whirlpool Baffle) in Arctic Master:*
A whirlpool, also known as a whirlpool baffle, is a internal feature designed to improve the separation of liquid and vapor refrigerant within the receiver tank.
In Arctic Master vertical receiver tanks, the whirlpool is typically a curved or spiral-shaped baffle located inside the tank. Its purpose is to:
- Reduce turbulence and mixing of the liquid and vapor refrigerant.
- Improve the separation of the liquid and vapor refrigerant by allowing the liquid to settle at the bottom of the tank.
- Enhance the overall efficiency and performance of the refrigeration system.
The whirlpool baffle helps to create a calm and stable environment within the tank, allowing the liquid refrigerant to settle and separate from the vapor refrigerant more effectively. This results in better system performance, increased efficiency, and reduced risk of liquid refrigerant carryover into the compressor.
#ArcticMaster
#LiquidReceiver
#HVAC
#RefrigerantManagement
#ASMECertification
#EfficientHVAC
#ReliableHVAC
#RobustConstruction
#HighPerformanceHVAC
#HVACSystems
#RefrigerantStorage
#RefrigerantSeparation
#FlowControl
#HVACR
#HeatingAndCooling
#RefrigerationSystems
*Description:*
"In this video, we take a closer look at the Arctic Master Liquid Receiver, a high-performance refrigerant management solution designed for HVAC systems. With its advanced features and robust construction, the Arctic Master Liquid Receiver provides efficient and reliable refrigerant storage, separation, and flow control.
Key benefits and features:
- High-capacity liquid storage and separation
- Efficient refrigerant flow control and management
- Robust construction with heavy-duty steel and corrosion-resistant coatings
- ASME certification for safety and reliability
- Customizable designs and configurations for specific applications
Whether you're an HVAC professional, engineer, or facility manager, this video provides valuable insights into the Arctic Master Liquid Receiver's capabilities and benefits. Watch to learn more about how this innovative solution can improve your HVAC system's efficiency, reliability, and performance."
*Tags:* Arctic Master, Liquid Receiver, HVAC, Refrigerant Management, ASME Certification, Efficient, Reliable, Robust, High-Performance.
Here are the explanations:
*Vertical Receiver Tank:*
A vertical receiver tank is a type of liquid receiver tank that is installed vertically, with the inlet and outlet connections typically located at the top and bottom of the tank, respectively.
In a vertical receiver tank:
- The refrigerant enters the tank through the inlet connection at the top.
- The liquid refrigerant settles at the bottom of the tank due to gravity.
- The vapor refrigerant remains at the top of the tank.
- The outlet connection at the bottom of the tank allows the liquid refrigerant to flow out of the tank.
*Whirlpool (or Whirlpool Baffle) in Arctic Master:*
A whirlpool, also known as a whirlpool baffle, is a internal feature designed to improve the separation of liquid and vapor refrigerant within the receiver tank.
In Arctic Master vertical receiver tanks, the whirlpool is typically a curved or spiral-shaped baffle located inside the tank. Its purpose is to:
- Reduce turbulence and mixing of the liquid and vapor refrigerant.
- Improve the separation of the liquid and vapor refrigerant by allowing the liquid to settle at the bottom of the tank.
- Enhance the overall efficiency and performance of the refrigeration system.
The whirlpool baffle helps to create a calm and stable environment within the tank, allowing the liquid refrigerant to settle and separate from the vapor refrigerant more effectively. This results in better system performance, increased efficiency, and reduced risk of liquid refrigerant carryover into the compressor.
#ArcticMaster
#LiquidReceiver
#HVAC
#RefrigerantManagement
#ASMECertification
#EfficientHVAC
#ReliableHVAC
#RobustConstruction
#HighPerformanceHVAC
#HVACSystems
#RefrigerantStorage
#RefrigerantSeparation
#FlowControl
#HVACR
#HeatingAndCooling
#RefrigerationSystems
Переглядів: 109
Відео
Bluestar New VI Plus (6plus) VRF Model.#hvacsupporttechie
Переглядів 200День тому
Hello everybody, welcome back to HVAC support techie Guys, as you can see on a screen we have a two different models of the VRF Blue Star make On the left hand side we have a new arrival of the 6 plus model On the right hand side we have a 5 plus model existing one So, you can see have a look on the 5 6 plus unit The dimensions are little bit compact and the height have been reduced And we have...
Daikin VRV 4 Mein Gas Pressure Kaise check karre हिंदी aur اردو mein. #VRF #VRV
Переглядів 17314 днів тому
The Daikin VRV IV is a variable refrigerant flow (VRF) system that provides heating and cooling for residential and commercial applications. It's available in heat pump and heat recovery configurations. Features Improved efficiency The VRV IV has an improved seasonal efficiency compared to the VRV III. It also has a heat-accumulating element that stores energy during heating to defrost the outd...
BlueStar/Gree VRF Auto Address Setting in हिंदी and اردو #Hvacsupporttechie.
Переглядів 19321 день тому
Test operation and debugging Notice: 1. After finishing the first installation or replacing the main board of outdoor unit, it is necessary to perform test operation and debugging. Otherwise, unit won't be able to work. 2. Test operation and debugging must ba performed by professional technicians or-gnder the guidance of professional technicians. Prepare the test operation and debugging (1) Do ...
Siemens MCCB/ Molded Case Circuit Breaker Replacement. #Hvacsupporttechie
Переглядів 396Місяць тому
Molded Case Circuit Breakers (MCCB) is a required component of electrical systems, providing overload protection and short-circuit protection. In most cases, MCCBs are installed in the main power distribution board of a facility, allowing the system to be easily shut down when necessary. #MCCB #MoldedCaseCircuitBreaker #ElectricalProtection #CircuitBreaker #ElectricalSafety #PowerDistribution #...
Aspen Drain Pump Hi-Flow हिंदी aur اردو mein. . #hvacsupporttechie #AspenDrainpump
Переглядів 195Місяць тому
Max Hi-Flow CONDENSATE REMOVAL PUMP The best in class Max Hi-Flow tank pump carries on the Aspen Pumps tradition of build quality & high performance. With the lowest dB(A) rating & best IP rating (IP24 splash proof) of any tank pump, the & Max Hi-Flow is the quietest & safest pump in its class. 550 Lh max. flow KEY FEATURES SUITABILITY 5m max. rec. head (flow rate 55L/h) IP24 - Splash proof Eas...
Bluestar VRF में Solenoid Valve क्या Kaam करता Hai हिंदी aur اردو mein./ Valves In 5plus VRF.
Переглядів 662Місяць тому
Solenoid valves use electromagnetism to electrically control the opening and closing of valves. They serve an important function in the automatic control of refrigerants, water, natural gas and other liquids in the HVACR industry. Solenoid valves work by creating an electromagnetic field that moves a plunger to open or close a valve. In a Variable Refrigerant Flow (VRF) system, solenoid valves ...
Accumulator Kya kaam karta hai Air conditioner mein हिंदी اردو mein.#Hvacsupporttechie #VRF #DryAll
Переглядів 358Місяць тому
An accumulator's purpose in a Variable Refrigerant Flow (VRF) system is to prevent liquid refrigerant from entering the compressor, which can cause damage and reduce efficiency: Protects the compressor Liquid refrigerant can cause severe damage to the compressor, which is designed to handle vapor. This is known as "liquid slugging". Maintains refrigerant charge The accumulator stores excess ref...
Bluestar Side Discharge VRF हिंदी aur اردو mein // VRF Kaunsa Best Hai ?
Переглядів 1462 місяці тому
Bluestar Side Discharge VRF हिंदी aur اردو mein // VRF Kaunsa Best Hai ?
Danfoss Compressor Mein Motor Protection Relay Kaise kaam karta hai हिंदी aur اردو mein.
Переглядів 4903 місяці тому
Danfoss Compressor Mein Motor Protection Relay Kaise kaam karta hai हिंदी aur اردو mein.
Chilled water Actuator wiring हिंदी aur اردو mein. #HVAC #Thermostat #Actuator #Chilledwaterunit.
Переглядів 4723 місяці тому
Chilled water Actuator wiring हिंदी aur اردو mein. #HVAC #Thermostat #Actuator #Chilledwaterunit.
Hydrogen Detector Controller For Battery Room हिंदी aur اردو mein. #hvacsupporttechie
Переглядів 1973 місяці тому
Hydrogen Detector Controller For Battery Room हिंदी aur اردو mein. #hvacsupporttechie
Contactor Kaise kaam karta hai हिंदी aur اردو mein / Contactor Wiring Easy | HvacSupportTechie.
Переглядів 1784 місяці тому
Contactor Kaise kaam karta hai हिंदी aur اردو mein / Contactor Wiring Easy | HvacSupportTechie.
AHU EC Fan हिंदी aur اردو mein / Belimo ENERGY Valve #hvacsupporttechie #AHU
Переглядів 2074 місяці тому
AHU EC Fan हिंदी aur اردو mein / Belimo ENERGY Valve #hvacsupporttechie #AHU
Ductable AC Full Wiring Seekhe हिंदी aur اردو mein 3TR,5.5TR,8.5TR,11TR AC #hvacsupporttechie
Переглядів 5024 місяці тому
Ductable AC Full Wiring Seekhe हिंदी aur اردو mein 3TR,5.5TR,8.5TR,11TR AC #hvacsupporttechie
ABB VFD programming -ACH531 || VFD setting हिंदी aur اردو mein. #hvacsupporttechie #ABBvfd
Переглядів 1614 місяці тому
ABB VFD programming -ACH531 || VFD setting हिंदी aur اردو mein. #hvacsupporttechie #ABBvfd
Belimo Damper Actuator | Actuator ko manually kaise khole हिंदी aur اردو mein. #hvacsupporttechie
Переглядів 1,1 тис.4 місяці тому
Belimo Damper Actuator | Actuator ko manually kaise khole हिंदी aur اردو mein. #hvacsupporttechie
Single Phase Preventer connections Full Video | SPPR ki wiring kaise kare हिंदी aur اردو mein.
Переглядів 3794 місяці тому
Single Phase Preventer connections Full Video | SPPR ki wiring kaise kare हिंदी aur اردو mein.
Bluestar Ductable Outdoor AC Mein Remote Controller ki full wiring Seekhe हिंदी aur اردو mein.
Переглядів 5185 місяців тому
Bluestar Ductable Outdoor AC Mein Remote Controller ki full wiring Seekhe हिंदी aur اردو mein.
ABB VFD Not Working || Start button se hi ON hotie hai VFD. || #ABB #VFD #Drive
Переглядів 2415 місяців тому
ABB VFD Not Working || Start button se hi ON hotie hai VFD. || #ABB #VFD #Drive
Bluestar IVRF mein communication cable kaise karre | GREE VRF || Hvac Support Techie
Переглядів 6875 місяців тому
Bluestar IVRF mein communication cable kaise karre | GREE VRF || Hvac Support Techie
AC sound level checking || DB meter || Use in HVAC field || Hvac Support Techie.
Переглядів 1585 місяців тому
AC sound level checking || DB meter || Use in HVAC field || Hvac Support Techie.
Error kaise Theek karre | Bluestar First Inverter VRF | Gree VRF #hvacsupporttechie
Переглядів 2,2 тис.6 місяців тому
Error kaise Theek karre | Bluestar First Inverter VRF | Gree VRF #hvacsupporttechie
Samsung Windfree Technology || VRF Samsung Hi-wall || No Air Technology ||Hvacsupporttechie.
Переглядів 3156 місяців тому
Samsung Windfree Technology || VRF Samsung Hi-wall || No Air Technology ||Hvacsupporttechie.
How To A Check Bad Fuse ? || खराब Fuse कैसे Check करें || Hvacsupporttechie
Переглядів 3846 місяців тому
How To A Check Bad Fuse ? || खराब Fuse कैसे Check करें || Hvacsupporttechie
How to connect Thermostat to Actuator | Belimo Thermostat | 10tr CSU | Hvacsupporttechie.
Переглядів 9466 місяців тому
How to connect Thermostat to Actuator | Belimo Thermostat | 10tr CSU | Hvacsupporttechie.
ABB VFD ACS310 Parametes Not Showing|| ABB vfd की सेटिंग || 2.2kw starter #Hvacsupporttechie
Переглядів 1576 місяців тому
ABB VFD ACS310 Parametes Not Showing|| ABB vfd की सेटिंग || 2.2kw starter #Hvacsupporttechie
Replace VRF Compressor Like a Pro || VRF का कंप्रेसर कैसे बदले || VRF 5plus || ANB78FVSMT SCI
Переглядів 4376 місяців тому
Replace VRF Compressor Like a Pro || VRF का कंप्रेसर कैसे बदले || VRF 5plus || ANB78FVSMT SCI
3phase AC full wiring | Bluestar Ductable AC wring 8.5tr seekhe |3 फेज वायरिंग आसान से सीखें
Переглядів 4597 місяців тому
3phase AC full wiring | Bluestar Ductable AC wring 8.5tr seekhe |3 फेज वायरिंग आसान से सीखें
F3 Error Bluestar VRF 5plus | F3error kaise solve karre.
Переглядів 5197 місяців тому
F3 Error Bluestar VRF 5plus | F3error kaise solve karre.
👍
Sir unit zyada highly pressure prblm ara Tu lagate na ye
Even that is the reason too.
CF0 error कैसे सॉल्व करे
Send me outdoor model number and Exact error.
Thanks Bhaiya❤❤
Thank q sir
superb, shall we connect for one of my project?
Sure, you can sir.
Pura video bhjo ne
Bahut achha video hy bro😊
VRF lite ?
No, 6plus.
Super
Sir ji is ka key kai say use kerna sir
Whatsapp me your doubts.
@hvacsupporttechie ok sir
Bro isko debugging ke liye software kon sa aata hai aur kya mobile tab main support krta hai
Licensed software hai, laptop mein support karta hai. Converter bi inbuilt driver ke saath ata hai.
❤
Unit kaise change karte bro
Do u have sequence programmed.
Good
Kaunsa refrigerant use horai system me
R410a
Same as west point VRF
Sir yah model Blue Star Mein Band Ho Gaya kya sir Kuchh Bhi PCB spare parts available nahin hai bol rahe hain
We had stock.
Excellent video..
Carrier VRF xpower ki pcb milegi?
Sorry not available.
Packages
Master unit 1 C3 and slip mein 1 C3 error aa rahe master unit 12 HP ka hai slip 28 HP ka hai
Pls msg me in insta.
Aap number chaye ham ko ek blue Star ka vrf system mein indoor C2 and outdoor mein C3 error aa rahe hain
Msg me on Instagram. Link in description.
I want to talk u urgent
Communication cable mai kitna volt aata h dc ya ac
Dc variable volt.
@mujeeb7100 dc voltage kitna 15 se 20 dc volt ya jyada master remote ke liye outdoor se wire jaata h ya indoor se hi conect hota h please
Outdoor master ke a2 b2 se central remote ke liya jata hai.
Communication cable 2 wire hota h ye aap 4 wire bta rhe ho master and slave loop conection nhi hota kya is machine mai
Slave outdoor mein A2B2 4 wire connect honge. Master mein A1B1 mein sirf 2 wire connect honge.
Bhai tawel switch wiring plz bataye
Two points wala mein neutral control hota hai, aur 4point wale mein neutral phase in aur neutral phase out hota hai.
F5 error what problem
Odu model number
❤
C9 kya aa rha hai
Communication error across indoor.
Ac remote nai chal ra hai
Thanks you. Happy new year 🎉.
Sr somnath se bapu 02 arr aata he free ho to col krna
How to check gas pressure on display side this unit
Sorry sir. This model does not have pressure sensors.
❤😊😊😊😊 thank q bhiya ❤❤❤❤
DLT temp kitna hona chahiya normal condition me
75c for TCN model.
Black wlaa transducer
watts w-ar2m-16 actuators to htw-wfo1-fc-mn connection diagram Please
DM me on insta gram , link on BIO. Send me the Picture too
watts w-ar2m-16 actuators to htw-wfo1-fc-mn connection diagram
Bhai pani naha dho k baher aata 😅😅😂
Aise aur karname hai humare paas project walo ke. Dikhae toh naraaz hojate unno.
Shukriya Bhaiya For Making This Video Its Useful For Us tqsm ❤❤
So nice of you
Allah aap ki kamai mein aur aapki Aulad mein barkat aur Allah aapko Allah Ke Ghar Aane Ki taufiq da Ameen ❤
Ameen❤❤
Ameen❤❤
Jazak allah khairan jaza
thank you bhaiya aapki followers ki request per aapane yah video Banai Mera bhi bahut jyada doubt tha yah solenoid valves ke uparMagar aapki yah video Dekhkar clear Ho GayaMagar aapki yah video Dekhkar clear Ho Gaya
super
Check out other videos as well.
super😮
super😮
😮
Good knowledge sir your video informative
Dont forget to check other videos too.
😊😊😊 thank you bhai aapka kimti Waqt nikal kar yah Khair ka kam kar rahe hain
Ac voltas or dc
Dc