Snapgas
United Kingdom
Приєднався 24 бер 2020
New (ish) gas engineer
Wanting to share my week by week jobs and help new guys learn what I have had to learn over the last couple of years
Gear reviews
Tool kit walk throughs of what I use
New tools as I buy them and will review as I use
Baxi, Worcester Bosch, veissmann, vaillant, atag, main, megaflo, ferroli, ravenheat, navien, grundfoss, wilo, heatgeek, intergas, talon, heatrae sadia, adey, boiler repairs, boiler servicing, boiler installation, new boilers, powerflushing, magna clean, adey chemicals, faulty pump, faulty pcb’s, diverter valve, balancing, efficiently, gas engineers, plumbing, Honeywell, Drayton, 2 port valve, 3 port valve, top up pressure
Wanting to share my week by week jobs and help new guys learn what I have had to learn over the last couple of years
Gear reviews
Tool kit walk throughs of what I use
New tools as I buy them and will review as I use
Baxi, Worcester Bosch, veissmann, vaillant, atag, main, megaflo, ferroli, ravenheat, navien, grundfoss, wilo, heatgeek, intergas, talon, heatrae sadia, adey, boiler repairs, boiler servicing, boiler installation, new boilers, powerflushing, magna clean, adey chemicals, faulty pump, faulty pcb’s, diverter valve, balancing, efficiently, gas engineers, plumbing, Honeywell, Drayton, 2 port valve, 3 port valve, top up pressure
Co alarm activation (virtual assessment)
First in this series related to IGEM G11 unsafe situations
I hope it’s useful
Below is the link so you can download and keep this with you
ua-cam.com/video/ecSaRKC5gVc/v-deo.htmlsi=lCUAf-Bn0bcrcAN7
I hope it’s useful
Below is the link so you can download and keep this with you
ua-cam.com/video/ecSaRKC5gVc/v-deo.htmlsi=lCUAf-Bn0bcrcAN7
Переглядів: 487
Відео
A job in my day as a gas engineer
Переглядів 8608 місяців тому
#gasengineer #diverter #leaking #leaks #plumber #vaillant #worcester #worcesterbosch #boiler #boilerfix #baxi
Vaillant boiler service & pressure loss
Переглядів 6448 місяців тому
#gasengineer #gasengineer #diverter #leaking #leaks #worcester #worcesterbosch #vaillant #boiler #boilerfix #boilers #boilerservicing #plumber #plumberjobs #plumbing #plumbinghacks
Vaillant turbo max diverter valve replacement
Переглядів 6599 місяців тому
Vaillant turbo max diverter valve replacement
Worcester greenstar flow manifold replacement
Переглядів 1,1 тис.9 місяців тому
Worcester greenstar flow manifold replacement
Vaillant diverter cardtridge replacement
Переглядів 4709 місяців тому
Vaillant diverter cardtridge replacement
Written off boiler from an aav #boiler #boilerservicing #gassafe #gassafety
Переглядів 989Рік тому
Written off boiler from an aav #boiler #boilerservicing #gassafe #gassafety
Viessmann heat exchanger replacement! Absolute pain
Переглядів 3,9 тис.Рік тому
Viessmann heat exchanger replacement! Absolute pain
Apps to help with fault finding & plumbing jobs
Переглядів 1,5 тис.Рік тому
Apps to help with fault finding & plumbing jobs
A day in the life of a gas engineer #28
Переглядів 3,9 тис.Рік тому
A day in the life of a gas engineer #28
A day in the life of a gas engineer #27
Переглядів 2,1 тис.Рік тому
A day in the life of a gas engineer #27
A day in the life of a gas engineer #27, magic box
Переглядів 3,8 тис.Рік тому
A day in the life of a gas engineer #27, magic box
A day in the life of a gas engineer #26
Переглядів 2,6 тис.Рік тому
A day in the life of a gas engineer #26
A day in the life of a gas engineer #25
Переглядів 2,1 тис.Рік тому
A day in the life of a gas engineer #25
A day in the life of a gas engineer #24
Переглядів 2,2 тис.Рік тому
A day in the life of a gas engineer #24
A day in the life of a gas engineer #23
Переглядів 2 тис.2 роки тому
A day in the life of a gas engineer #23
Are you ex BG?
Should serv mode be always at 100?
If your gas safe and have done your course, all appliances need to be tested at max and minimum rates
Excellent
Funny to year you say “new Viessmann” because I just had a new 100-w installed and this thing looks very dated 😂
This is an old video 👍
No draining required?
Please contact a plumber as they will be able to help you
Chnaged that becuase was heating but not hot water?
I’ll be honest with you that was a long time ago now, I can’t fully remember
@snapgas9832 no I understand. I looked at the baxi 80e boiler today, they have hot water only when heating is on, but no hot water without the heating. Any idea?
Is the nerrard spanner a 32mm or 54mm?
Think it’s 32mm mate
Great find.
You help us so much with ur vids top man👍🏻👍🏻
Good video
Really good ideas
Get rid of the music, I can't hear a word you are saying.
Free free four i fink
Had this a few weeks back too, nightmare lol 😆
Easy done
Yeah mate very easily done! Spend ages looking for something that was right infront of you, cheers for watching
Looking online for the main heat exchanger assembly seems they come without the left and right bottom feed pipes - just wondering how you the old ones were swapped to a new heat exchnager...
Hi mate, yeah the heat exchanger will just come literally as that, With regards to how they refit back in after I normally would order up new seals for them bits and grease them up Failing that I would just really grease them up and see how it goes
Welcome back but the subtitles are distracting af
Apologies mate I’ll ditch those then 😂
Do you work for a company then mate or for your self? Love the videos btw the boiler breakdown down stuff especially 👍
I work for a company mate, but actually trying to move into management now as getting a bit older and fed up of driving around 😂
Great to see you back chris, just wanted to know you were going to open up a training centre any news on that or have you given it a miss? Keep the videos comming ive learnt alot from them thanks
Good vid Chris!
Cheers toddo
Good video pal, just wondering are you not still working on BG contract?
Cheers mate, no I left that coming up to a year ago mate
Glad your back!
Thank you mate! Will be more coming
Great job buddy. Keep the videos coming
Appreciate that mate
Hello mate, I was lead to be believe we need a separate ticket to investigate a CO being activated CMDDA1. ?
Hello mate, I will look into this now. I’ve been to plenty for British Gas, would get them weekly
@ if you could that be great. They mentioned it when I done my last assessment.
Ya left shitish gas pal
It's true, you're supposed to be qualified to do a proper assessment. I get them every so often (social housing), I "check out" the appliances, change the CO alarm. And give them ventilation / evacuation instructions and fuck off. It's always been faulty alarms, but sending untrained people is a cop out.
I had this last week, if you follow the chart in igem11 it says if you are happy to turn back on do so but if not escalate to someone with CMDDA1.. in December gas safety mag there is a question asking if you need cmdda1 to investigate an alarm, their reply says no.
Great to see you back...
Thank you mate
Welkom back,
Thank you mate! Hope it’s useful
Great idea mate. Can be a bit vague sometimes..
Absolutely cheers I will do them
Don’t bother registering pal, it’s a load of shite.
Wish we had that option mate but unfortunately we don’t, but there’s a lot to keep on top of with unsafe situations etc
Think it’s a great idea
Completely useless video, can’t see what your adjusting,
How can you not see what is being adjusted? There are close ups of it….. Also this is for gas safe engineers to do
I’ve had the same on a baxi solo a couple of times now, change the door seals and sorted.
Yeah I think alot of different boilers have this issue, I had it on a Baxi solo aswell with the door seals and the sump seals blowing onto the overheat stat on the fan Cheers for watching
P 02 what is this??
If you don’t know I’m not sure your gas safe, please get a gas safe engineer to help you
stop the stupid annoying music.
This was my first few videos and was extremely nervous, apologies
I saw your videos, your video quality is good but not properly SEO. Your SEO score is very poor. That's why your channel is not growing organically. SEO means Search Engine Optimization. I think you understand, for views, subscribers, and comments your video should be ranked on top of UA-cam, Proper SEO that means keyword session ( low competitor keyword selection) can help your channel to rank on the top. Thank You
Ok thanks for that, not sure what all that means but appreciate your comment
Im loosing pressure but when connected air pump to the vassel valve...water leaked from the valve....what does this mean...there is water in the tube?
Please contact a gas safe engineer
Music so loud it’s a waste of a good video!
Apologies was 1 of my first videos and was very nervous
Brilliant explanation
Glad you liked it
I had this E133 on a baxi duotec fault today the gas valve isnt passing.. Ive hooked u gauge to inlet 23mbar does not drop im thinking gas valve faulty any ideas
Thank you , what can I spray on the pin to help release it , 👍
Wd40 or something similar gt86 for example
Brilliant - clear and concise. Great video.
Glad it was helpful!
Dont suppose this happens on a 4000 30kw model does it ?
It could do as they have the square type of heat exchanger, I had it on an old cdi the gasket at the front had gone and was blowing heat to the over heat stat next to it
To anyone watching be careful. The brass valve snaps off if you apply too much force obviously. 😢
True this can happen
Great info. Got exactly this problem. Cheers.
Your a good lad. Love your video,s. Thank you for your time.
Thanks Greg
Worcester have a technical bulletin about the red seal. They should be telegan’d everytime to check if they are failed and if products of combustion are leaking into the combustion chamber. Also changed every 5 years at least I think it was too.
Yeah mate they did, and yes you are right! Reason I put this video out was that it stumped me and couldn’t work out why it was showing over heat with no sign of the boiler over heating! Everydays a school day in this game
@@snapgas9832 yeh some good videos mate started watching through them and followed! As you say every day a school day
Hi, in what situation or fault of the boiler for this hydraulic assembly replacement?
Hi, what I found was there multiple blockages and was unable to clear them from memory
Cheers, exactly what was needed, improved the continuity with a piece of emery and it all worked as it should
Currently got this problem on a two year old install and im absolutely stumped.
Open vent, 3 port, new pump 🫠
If the co2 doesn't adjust within range is it a faulty gas valve?
Not necessarily mate, could be that the gas valve needs adjusting Or could be the heat exchanger is blocked up etc
The tapper just blitz it instead of taking weeks over it
I'd have refused to fix it until they put a new battery in their smoke alarm!!