Pentair Mastertemp 400 Igniter Troubleshooting and Replacement
Pool heater failing to ignite gas. Easy troubleshooting and repair.
Переглядів: 46 113

Відео

Troubleshooting a high limit sensor error (HLS) on a Pentair Mastertemp 400 gas pool heater.Troubleshooting a high limit sensor error (HLS) on a Pentair Mastertemp 400 gas pool heater.
Troubleshooting a high limit sensor error (HLS) on a Pentair Mastertemp 400 gas pool heater.
Переглядів 51 тис.4 роки тому
Pentair Mastertemp 400 gas pool heater cycling due to a high limit sensor error. Three potential causes addressed: High limit sensor, thermal regulator, bypass valve. Testing high limit sensor, replacing thermal regulator.
Troubleshooting Pool Heater Thermal Regulator (Thermostat)Troubleshooting Pool Heater Thermal Regulator (Thermostat)
Troubleshooting Pool Heater Thermal Regulator (Thermostat)
Переглядів 10 тис.4 роки тому
Temperature testing the thermal regulator from a Pentair Mastertemp 400 gas pool heater. Addressing a problem with the heater cycling and throwing a high limit sensor light code. See related video of addressing the overall problem with the heater.

КОМЕНТАРІ

  • @redneckbird2121
    @redneckbird2121 3 місяці тому

    Awesome video! Thank you! Got mine up and running today! 👍

  • @crglass67
    @crglass67 5 місяців тому

    Ordered the part on amazon for about $50 (pool store wanted $99 for OEM), installed in 20mins and now I got some hot in my hot tub! Thanks for making a very detailed video!

  • @jeffnorris5357
    @jeffnorris5357 5 місяців тому

    I realize that you posted this quite a while ago but just wanted to say that my heater is performing exactly like what you described and I am ordering an igniter today. Thank you for taking the time to post such a detailed video!

  • @ScottKovacs-i2p
    @ScottKovacs-i2p 10 місяців тому

    Thanks for this video! I removed my Thermal Regulator and the issue of "on/off" cycling was immediately fixed. I've got the new Thermal Regular part on order and will replace it. My question is why wouldn't I just leave the Thermal Regulator out all the time? As long as water is flowing through and heating what's the purpose of the part. Does the thermal regulator act as a back flow to stop water coming backwards through the system when the pump is off? Thanks!

    • @GoldenPenniesProspecting
      @GoldenPenniesProspecting 10 місяців тому

      Great question. Sorry, I don't know the answer. I suspect is may have something to do with efficiency, but that is just a guess.

  • @richarddelaney9593
    @richarddelaney9593 Рік тому

    Whats the purpose of the thermal bypass valve? How does it work?

  • @impalass412
    @impalass412 Рік тому

    Thank you 🙏

  • @ThatMattGuy
    @ThatMattGuy Рік тому

    My Mastertemp 250 would not even try to fire when turned on, straight to service heater light. Hot wired the switch wires and it fired right up. Ordered replacement on Amazon and was back up and running in 2 days. Thank you for the help. Your video gave me insight into what my heaters HLS system was looking for.

  • @bsatchel705
    @bsatchel705 Рік тому

    Hello. I have an HLS light. The spa heats to approx 91, then shuts off for 2 minutes and comes back on for 90 seconds then repeats itself. The heater runs fine when I am in pool mode. I've replaced my thermistor, HLS and thermal regulator, and I still have the HLS light and all the same symptoms. No rattling or odd noises. It's a 3 year-old heater. Any ideas? Thanks

    • @bradgalles3139
      @bradgalles3139 Рік тому

      Please let me know if you've figured anything out. I have the same exact issue and have replaced the same parts you have and the issue is still happening. I did take the manifold apart and checked the bypass valve and that looked fine - not sure if you checked that. I'll let you know if I figure it out on my end. Take care and good luck

  • @ja72737
    @ja72737 Рік тому

    Thank you very much! The symptom matched my issue perfectly, and I had already replaced the HLS.

  • @billscaggsify
    @billscaggsify Рік тому

    What is the part numbers?

  • @markgrounds759
    @markgrounds759 Рік тому

    Good video, except I was getting an AGS Light. After troubleshooting AGS, determined it was the high limit sensor that you pointed too & disconnected. I bypassed HLS with a wire, turned system on and heated to 99. No service light. Will replace HLS. Just a FYI

  • @carlosaceves8186
    @carlosaceves8186 Рік тому

    Super video Thank you

  • @the.trollgubbe2642
    @the.trollgubbe2642 Рік тому

    What if it doesn't turn on at all, no lights, nothing ?

  • @jamescoulter267
    @jamescoulter267 Рік тому

    That gasket didnt leak water?

  • @TC-bj8pu
    @TC-bj8pu Рік тому

    Great video! What was the igniter part number you used? Do you have a favorite place to buy these parts? Thanks again!

  • @craigrobison9766
    @craigrobison9766 2 роки тому

    Haha, my 400 failed at year 4. They suck

  • @j3d3d1ah
    @j3d3d1ah 2 роки тому

    Curious, what is that Rubbermaid deck box next to the heater for?

  • @j3d3d1ah
    @j3d3d1ah 2 роки тому

    Saved me $1,000 repair (quoted by a local repair technician). Very good and helpful video.

  • @markhannigan8510
    @markhannigan8510 2 роки тому

    I was able to replace my thermal regulator without using the clip (I noticed it in the box after I installed it). Is it absolutely necessary to have the clip installed or does just hold onto the spring? Thanks for the great video.

  • @reservoirdog1099
    @reservoirdog1099 2 роки тому

    So if it wasn't your thermal regulator. Then what was your problem with your heater. Mine is doing the same thing and I have replaced the regulator, gas sensor and HLS sensor to no avail.

    • @georgecox5297
      @georgecox5297 2 роки тому

      Same here. New manifold with new HLS, GSS and thermal regulator. Heater works fine without thermal regulator. Thermal regulator opens in very hot water. I'm wondering if it doesn't open at 140 degrees/early enough/proper temperature and that is why it still rattles and cuts off the system with an HLS error message. I'll check the temperature at which the thermal regulator is supposed to open and test with water at that temperature.

    • @risforrichards4856
      @risforrichards4856 Рік тому

      Has anyone figured this out, I am in the same position. My regulator functions correctly, heater turns on then off 30 sec at a time continuously. Heats the water but something is going on and I can’t figure it out.

    • @timothypruitt6257
      @timothypruitt6257 8 місяців тому

      @@risforrichards4856did you ever find the issue? I’m currently having some of the same issues

  • @justinreynolds3935
    @justinreynolds3935 2 роки тому

    Worst heaters ever. I replace so many regs on these things it's rediculous. Also the control panels are source of issues too. Half the time the error code lights aren't exactly the problem. Get Hayward. Lol

  • @noahcross1490
    @noahcross1490 2 роки тому

    I really appreciate your channel. I hope you get more subscribers, likes and shares. Great info and instruction. 👍

  • @MigsNSX
    @MigsNSX 2 роки тому

    What is the Part Number for the MasterTemp 400 Igniter? Solid Video!

  • @evomatic
    @evomatic 2 роки тому

    Great video, I had trouble loosening the cap to replace the thermal regulator. Turns out a better tool (that didn't bend) and some two handed elbow grease did the trick (one hand twisting cap, the other on end of tool). The old regulator ended up getting stuck inside as I feel they make the clip ends a touch too long which catches on the inside threads. Took about 10 minutes of shimmying to get er out. Once out, the old one was indeed corroded and rusted. Guy at the pool shop had suggested doing the HLS switch first as that was the error code on flipside of panel so I bought both parts and did the HLS first to no avail. In hindsight probably should have tried the thermal regulator replacement first. Thanks again for the great video!

    • @evomatic
      @evomatic 2 роки тому

      Another thought, since the old one was corroded, should I have attempted to clean on the inside? Would have been tough to access in there but any advice on that?

  • @tracybradley4448
    @tracybradley4448 2 роки тому

    Hi. Ours is this way only it doesn’t do 3 attempts. The first attempt it kicks a breaker /circuit. I had a trap at man freak and run when he smelled the gas. I believe we have a mouse ruined wire but need help!!

  • @earlevery5288
    @earlevery5288 2 роки тому

    AGS. Erra. Reading

  • @NewHomeRealtor
    @NewHomeRealtor 2 роки тому

    THANK YOU so much. With your video I was able to troubleshoot one of the HLSs. I shorted out each one until I found the culprit. Cleaned the connectors and it works now. I guess I was lucky. Thanks so much!!

  • @guillermopalmisano8957
    @guillermopalmisano8957 2 роки тому

    Thank you so much for this video. Luckily that was the case and I was able to pull it off of an old parts one I had

  • @woodenhallconcerts4677
    @woodenhallconcerts4677 2 роки тому

    Hi there - great video which identified the problem. BUT - there's water in the combustion chamber! I assume that's really wrong, do you have a video or recommendation to fix?

  • @MS4323
    @MS4323 2 роки тому

    Thank you. Informative and helpful.

  • @pulodogato3888
    @pulodogato3888 2 роки тому

    Ótimo vídeo 🇧🇷👍🏼

  • @bobvanepps7517
    @bobvanepps7517 2 роки тому

    This video was very helpful. Now I need a little advice to confirm my troubleshooting. I removed the thermo-regulator and the heater stopped cycling on and off. I heated some water in the microwave and put the thermo-regulator in the water. It opened as expected. This tells me that the thermo-regulator is working properly. Am I correct to assume that the likely source of my problem is the high limit switch? Assuming yes, I can buy a new switch and replace the old one. Is there anything else that I may be overlooking? Finally, as a shot term solution, is it generally safe to run the heater without the thermo-regulator for a short period of time so my family can continue to use the spa until I get a replacement HLS switch? I would ask the same question about purposely shorting the HLS temporarily. Thanks in advance for any advice.

    • @RoBjOb48
      @RoBjOb48 2 роки тому

      You can test your HLS with a volt meter, set to check continuity and see if there is continuity between the two connection pins; if your HLS is good and your thermostat (thermal regulator) is still good but still having a problem it may be the Internal Bypass Valve has failed and may need replaced.

  • @markromero930
    @markromero930 3 роки тому

    I watched this video and then troubleshot my heater. I thought it was the igniter, maybe it still is so I ordered one. Then I got an air flow sensor fault so I ordered that. I removed the igniter while the heater was trying to light and it was red hot so I assumed it was good. I installed the new afs a minute ago and still no ignition. I still may need the igniter. What else could it be?

    • @GM-pm4hm
      @GM-pm4hm 3 роки тому

      Rats loved to get inside these thing. There is a rubber tube that goes from your afs switch to the fan area. If rats or anything chewed a hole in it, you can change the switches all day long but with a hole in the tube it still won't light.

  • @dazit2833
    @dazit2833 3 роки тому

    Thanks so much for your knowledge. It helped me alot.

  • @michaelmays7004
    @michaelmays7004 3 роки тому

    My problem is that it lights, only stays on for a few seconds maybe 20-30 and makes a loud noise . shuts down and service heater light comes on. Not sure what it could be, any ideas. It is a mastertemp 250

  • @12OneLovee
    @12OneLovee 3 роки тому

    I pulled the igniter out and there was water in there is that normal?

  • @mikeconnor7394
    @mikeconnor7394 3 роки тому

    Hi - I wanted to say this video SOLVED my Pentair Propane heating issue and saved my summer - I was shocked when i opened my heater - We installed it 3 years ago on my pool - we never had one and we did over the liner and some retaining walls - we basically rebuilt our pool - but for 3 years this heater performed amazing and it died near the end of last season and I figured I would fix it next summer - I browsed this video and followed the steps - good thing I opened the unit to my surprise - Inside I found a nest of leaves and debris - man it looked like my new heater was rotting - then I opened the control box and found two dead chipmunks that chewed threw all my 24v wires - man What a repair - but the hardest thing I had was getting my igniter out - one of the 1/2' nuts lock froze and I had to break the post - I have a metal shop in my barn and quickly welded a new bolt to the hood and reseated the igniter - the igniter I got from Amazon and it came with a 1 time use only gasket (I thought it was like made out of cotton? seemed very flimsy but the igniter went in just like the video said - the unit was so cheap I saved a ton - the gas company was gonna charge me 250 to do the work I did it all in like 4 hrs - it was quite a day and I enjoyed a night swim with a warm pool - Thanks guys! this a 10 star! two thumbs up video - any DIY'er that owns a pool and propane heater should catalog and bookmark this video

  • @SteichenFamily
    @SteichenFamily 3 роки тому

    Any idea what the normal resistance range is on these igniters? I have the exact same symptoms on a Pentair Mastertemp 125, but instead of an open circuit, I'm showing 100 ohms.

    • @TheNYgolfer
      @TheNYgolfer 3 роки тому

      pause the video at 11:37 for the answer that you were too lazy to find yourself

  • @adrianchavez8949
    @adrianchavez8949 3 роки тому

    Hello, if you can help please. I just changed the Thermal regulators and that did not cure the problem of it shutting on then off at a two minute Intervals when it reaches 87 degrees. Any ideal what should I change out next. It would be much appreciated. Thank You!

  • @jeffbonzerpeterson
    @jeffbonzerpeterson 3 роки тому

    How about checking voltage going to the igniter safely with the gas valve off when the system calls for heat and you hear the gas valve open?

    • @TheNYgolfer
      @TheNYgolfer 3 роки тому

      Installed a new Pentair 250 today and it wouldn't ignite. Checked for voltage to the igniter and got 60 VAC during the ignition cycle. Was going to condemn the ICM but fortunately I read the troubleshooting guide. It said "The ICM will convert 240VAC/120VAC to an intermittent pulse to the igniter. Digital meters don't read this type of signal well. Analog meters do a better job." The igniter was bad. So don't rely on voltage readings to the igniter.

  • @nickbax5237
    @nickbax5237 3 роки тому

    This video was very helpful. Great explanation, thank you for this one and the others!!

  • @mckeedesigns2426
    @mckeedesigns2426 3 роки тому

    You mentioned in the video that cycling 3 times and kicking in the service heater light is usually a bad igniter, but what if it does that same thing but the igniter is good? I used my Pentair 125 pool heater 1 day and it worked fine. It fired, heated up to temperature, turned itself off. When the pool water dropped below the set point it tried to turn on and now I am getting exactly what symptoms you show in your video. I checked the igniter and I have 59.9 ohms. Gas pressure is good. I hear the 3 clicks in the gas valve but do not smell gas during ignition sequence. Any suggestions?

    • @mikeconnor7394
      @mikeconnor7394 3 роки тому

      I bet the air flu or pressure switch has a blocked tube - check for air intake and outtakes blocked I found hornet nests in mine

    • @pulodogato3888
      @pulodogato3888 2 роки тому

      Existe uma válvula selanoide que dá passagem para liberar o gás.

    • @stevengraham6842
      @stevengraham6842 2 роки тому

      @@pulodogato3888 Yes, I repaired a clothes dryer by replacing the gas valve solenoids. Good call!

  • @daryomartynezalbarez2570
    @daryomartynezalbarez2570 3 роки тому

    Lo e cambiado varias veces aquel se debe que sea continuo la falla que daña la pza

  • @Eric-ot1fn
    @Eric-ot1fn 3 роки тому

    I’m having the same problem with a master temp 400 that’s only a month old, but I’m getting a 128 and r14 code I’ve change the water temp sensor that goes in the pvc and the temp sensor for the air but still I’m getting the same codes They also have a jandy rs control pad in the house I’ve reset the value on that pad to get rid of the existing programs And I think it reset the temp values also Would that be a reason why the heaters is not igniting?

    • @dorse72
      @dorse72 7 місяців тому

      hi have a friend w the same issue, did u every figure out the root of the problem? thanks

    • @Eric-ot1fn
      @Eric-ot1fn 7 місяців тому

      @@dorse72 it he needed a bigger gas regulator, so the gas company had to come out and change it

  • @russchiappa4870
    @russchiappa4870 3 роки тому

    Now this was a very worthwhile video it gave me some DIY tips that I can investigate on my own thank you very much

  • @dictumfactum7784
    @dictumfactum7784 3 роки тому

    Get your motor fixed

    • @tdkdjmasksolutions2174
      @tdkdjmasksolutions2174 3 роки тому

      Yep. Very loud. It's actually not the motor, it's the blower. Been like that for nearly 2 years. I figure once it stops working on replace it for the meantime it's not in the place where the noise bothers anyone

  • @Ambersol09
    @Ambersol09 3 роки тому

    Any issues with running the heater without the regulator? I'm on myrd rd one in 2years and the price has jumped by 400% in the last two months.

    • @tdkdjmasksolutions2174
      @tdkdjmasksolutions2174 3 роки тому

      Sorry, I don't know the answer. I did run mine for a while without the regulator, and it ran fine. I think the issue is that it runs more often and doesn't heat as efficiently, but that is only a guess.

    • @officerkrupke4966
      @officerkrupke4966 2 роки тому

      The thermal regulators main function is to prevent condensation on outer surface of heating coils which causea them to rust. You can safely operate without one if you can manually close off inlet and outlet of heater via bypass valves if you have them, and manually reopen them before using heater. Pentairs newest version of their heater has the capability of automatically opening and closing of a bypass valve whenever the heater is operated.

  • @yolandareyes7435
    @yolandareyes7435 4 роки тому

    Please help me whit traducción in spanish

  • @markhillsborough5661
    @markhillsborough5661 4 роки тому

    Have the same issue with my brand new Pentair MasterTemp 400 heater. Pretty disappointed. Had my old heater for 23 years with no major issues. This one has issues in the first week of operation!

    • @WMDxLogic
      @WMDxLogic 4 роки тому

      Mark Hillsborough hey so what did u end up doing? I’m having exact same issue

    • @markhillsborough5661
      @markhillsborough5661 4 роки тому

      I had the thermostat replaced and it worked fine the entire summer. It’s a shame that a brand new unit had a defective thermostat but that was it.

    • @WMDxLogic
      @WMDxLogic 4 роки тому

      Mark Hillsborough Same mine was a brand new unit and I keep getting a HLS error and when I do the jumper it works properly

    • @dictumfactum7784
      @dictumfactum7784 3 роки тому

      Master dumpster

    • @tdkdjmasksolutions2174
      @tdkdjmasksolutions2174 3 роки тому

      I apologize for not seeing your post much much sooner. Glad to see that fixing the thermostat fixture problem. Is it still working well?