Omron S8VK-X EtherNetI/P Connection
How to configure the S8VK-S and setup tag datalinks.
Переглядів: 375

Відео

Omron NXIO with an Allen Bradley PLC. EIC-202
Переглядів 1,6 тис.6 років тому
A quick tutorial on how to use NXIO with an Allen Bradley PLC. EDS file can be found here: industrial.omron.ca/en/products/nx-series#downloads The EIC-202 can be set with either a 192.168.1.XXX or a 192.168.250.XXX IP address through the physical switches. Anything beyond these two subnets will require the DHCP to be enabled on the EIC-202.
Sysmac NJ/NX and Compact Logix Ethernet/IP Communication
Переглядів 6 тис.6 років тому
Omron Sysmac PLC and Allen Bradley PLC Ethernet/IP Communication. Setup should be the same for NJ and NX as well as Control and Compact Logix. The 4 extra bytes of data may or may not be needed. Never hurts to make room for them.

КОМЕНТАРІ

  • @zaifengchen5135
    @zaifengchen5135 11 місяців тому

  • @anthony54720
    @anthony54720 2 роки тому

    Is it possible to exange string datas between nx102-9000 and compactLogix ? And how can I do it please ?

    • @rancid11999988
      @rancid11999988 2 роки тому

      Yes but Rockwell does strings differently than Omron

  • @sebastiangomezhurtado6329
    @sebastiangomezhurtado6329 2 роки тому

    hi, thank you for the video, so in my case, i added the a generic module but I'm getting an error of invalid segment type, which I consider that to be the connection parameters for the I/O and configuration. The data size for my I/O is I 4/504 [bytes] O 0/504 [bytes], any suggestions ?

  • @vishalgyanchandani4437
    @vishalgyanchandani4437 2 роки тому

    Can you also make video for CIP communication for same power supply as well?

  • @GreybeardGeek
    @GreybeardGeek 3 роки тому

    Very helpful, thank you. One nit to pick: You should always use the CPS instruction instead of the COP instruction when working with I/O buffers, to prevent invalid data if an I/O packet is sent or arrives while the COP instruction is running. The CPS instruction locks the source and destination memory areas to prevent interference from message traffic, I/O packets, or higher-priority tasks. CPS is otherwise identical to the COP instruction.

  • @reylepiten3722
    @reylepiten3722 4 роки тому

    Is it possible for omron CJ models?

    • @charliedosh6163
      @charliedosh6163 4 роки тому

      nope

    • @rancid11999988
      @rancid11999988 2 роки тому

      Absolutely. The datalink is made by network configurator though, not Sysmac. CJ1W-EIP21 cards or the built-in EIP work fine and require the 4 byte offset.