- 293
- 292 140
EI & Automation বাংলা - Engr. Pervez A Islam
India
Приєднався 27 жов 2021
Welcome to Engr- Pervez A Islam (EI & Automation)
Join and Subscribe to create a decent career in an industry as an Electrical, Instruments and Automation Engineer with technical skills and real time experience.
TOPICS:
1. MS Office, Excel, PP and Microsoft Visio & AutoCAD basic and advance for engineering drawing.
2. PLC & SCADA Panel Design & Programing on all kinds of Siemens PLC, Mitsubishi PLC, Allen Bradley Micro Logix PLC, FATAK PLC, and Selec PLC. All VFD, MFM & Others devices communication work with PLC.
3. VFD Panel Design, Drawing making and programing work for Siemens G120 and V20 VFD, Schneider VFD, ABB VFD, Allen Bradley VFD, LS and so on.
4. Substation Protection Relay Programing, Transformer Maintenance.
5. CEMENT & CABLE Manufacturing Machineries, chillers, Boilers, RO, heater, Sensors, Signal Isolator, ATS, Actuator, Temp. controllers, solenoid, Limit switch, TC, RTD, Phase Failure, Motor controller, Insulators, Lighting Arrester, FT, PT, RADAR etc.
Join and Subscribe to create a decent career in an industry as an Electrical, Instruments and Automation Engineer with technical skills and real time experience.
TOPICS:
1. MS Office, Excel, PP and Microsoft Visio & AutoCAD basic and advance for engineering drawing.
2. PLC & SCADA Panel Design & Programing on all kinds of Siemens PLC, Mitsubishi PLC, Allen Bradley Micro Logix PLC, FATAK PLC, and Selec PLC. All VFD, MFM & Others devices communication work with PLC.
3. VFD Panel Design, Drawing making and programing work for Siemens G120 and V20 VFD, Schneider VFD, ABB VFD, Allen Bradley VFD, LS and so on.
4. Substation Protection Relay Programing, Transformer Maintenance.
5. CEMENT & CABLE Manufacturing Machineries, chillers, Boilers, RO, heater, Sensors, Signal Isolator, ATS, Actuator, Temp. controllers, solenoid, Limit switch, TC, RTD, Phase Failure, Motor controller, Insulators, Lighting Arrester, FT, PT, RADAR etc.
How to Megger HT Monoblock / Bushing / Insulator and how to improve the Resistance
How to Megger HT Monoblock / Bushing / Insulator and how to improve the Resistance
#dcs #electrical #industrialautomation #siemens #electric #electronicmusic #engineering #industrialcontrol #machine #music #highvoltagedrama
#dcs #electrical #industrialautomation #siemens #electric #electronicmusic #engineering #industrialcontrol #machine #music #highvoltagedrama
Переглядів: 108
Відео
Intecont Plus Event /Alarm/ fault identification Shenck Process
Переглядів 187 годин тому
Intecont Plus Event /Alarm/ fault identification Shenck Process
Inside construction of a Silo system and air aeration distribution system
Переглядів 3121 годину тому
Inside construction of a Silo system and air aeration distribution system #dcs #industrialautomation #electric #engineering #industrialcontrol #machine #plc #siemens #electrical #siemensplc
আপনার Power Factor Meter সঠিক পরিমান ক্যাপাসিটর কি ধরাচ্ছে? This Video is your solution.
Переглядів 69День тому
APFC Panel এর পাওয়া ফ্যাক্টর মিটারের ভ্যালো 0.99 দেখায় এবং লোডের পরিবর্তনের উপর নির্ভর করে ক্যাপাসিটর ধরে এবং ছাড়ে। এভাবে করে পাওয়ার ফ্যাকটর এর ভ্যালো ০.৯৯ ম্যাইন্টেইন করে রাখে। কিন্তু মাস শেষে পওয়ার ফ্যাকটরের জন্য জরিমািনা আাসে। এর মানে হলো পাওয়ার ফ্যাকটর ঠিক কাজ করছে না। প্রশ্ন-১ঃ জন্য আমাদের চেকিং পয়েন্ট বা এর কারন কি হতে পারে? প্রশ্ন-২ঃ সঠিক পরিমান ক্যাপাসিটর ধরাচ্ছে কিনা পাওয়ার ফ্যাকটর তা ...
Lightning Arrester with early streamer emission air terminals method
Переглядів 5014 днів тому
Lightning Arrester with early streamer emission air terminals method
Siemens S7 400 Communication Processor Fault finding
Переглядів 13014 днів тому
Siemens S7 400 Communication Processor Fault finding
Vibrator Motor / Unbalanced Induction Motor working and Weight settings
Переглядів 3014 днів тому
Vibrator Motor / Unbalanced Induction Motor working and Weight settings
Siemens S7 400 Control Processor Unit (CPU) Fault finding
Переглядів 7021 день тому
Siemens S7 400 Control Processor Unit (CPU) Fault finding
Siemens S7 400 Power Supply Fault finding
Переглядів 16128 днів тому
Siemens S7 400 Power Supply Fault finding
Troubleshooting of Siemens S7-400 DCS PC Hard Drive and Power failure issue.
Переглядів 214Місяць тому
Troubleshooting of Siemens S7-400 DCS PC Hard Drive and Power failure issue.
Lightning Arrester: Conventional method vs collective method vs Early Streaming Emissions method.
Переглядів 76Місяць тому
Lightning Arrester: Conventional method vs collective method vs Early Streaming Emissions method.
HT Motor Chinese LRS starter modification work by Siemens S7 200 PLC
Переглядів 77Місяць тому
HT Motor Chinese LRS starter modification work by Siemens S7 200 PLC
Industrial marine painting mixing ratio with hardeners and thinner (Ratio - 2:1:0.2)
Переглядів 8Місяць тому
Industrial marine painting mixing ratio with hardeners and thinner (Ratio - 2:1:0.2)
IR Compressor IR Dryer A5 alarm & atco fault rectification
Переглядів 52Місяць тому
IR Compressor IR Dryer A5 alarm & atco fault rectification
IR Compressor IR Dryer Pb4 fault rectification
Переглядів 67Місяць тому
IR Compressor IR Dryer Pb4 fault rectification
IR ingersol rand compressor controller parameters settings
Переглядів 21Місяць тому
IR ingersol rand compressor controller parameters settings
Atlas copco compressor controller parameters settings
Переглядів 48Місяць тому
Atlas copco compressor controller parameters settings
mimilec Phase Failure Relay VSP D1 wiring & Specification
Переглядів 99Місяць тому
mimilec Phase Failure Relay VSP D1 wiring & Specification
Damage VCB Maintenance (Know How we improve Insulation Resistance)
Переглядів 622 місяці тому
Damage VCB Maintenance (Know How we improve Insulation Resistance)
Endress + Hauser Promag Wiring and programming with password
Переглядів 382 місяці тому
Endress Hauser Promag Wiring and programming with password
Masibus 408 Indicator Connection, configuration, Parameters and mA Adjustment
Переглядів 932 місяці тому
Masibus 408 Indicator Connection, configuration, Parameters and mA Adjustment
Rittal Panel AC details in Bangla (Gas circulation & Controller wiring)
Переглядів 1613 місяці тому
Rittal Panel AC details in Bangla (Gas circulation & Controller wiring)
Manually checking processes of tripping relay of IDMT Relay
Переглядів 374 місяці тому
Manually checking processes of tripping relay of IDMT Relay
ABB REJ 601 IDMT Relay Current & Earth fault settings
Переглядів 1414 місяці тому
ABB REJ 601 IDMT Relay Current & Earth fault settings
Siemens Smart 7KT Multifunction Meter Wiring and Parameters
Переглядів 2354 місяці тому
Siemens Smart 7KT Multifunction Meter Wiring and Parameters
11 KV VCB Panel checking by given external sources & sharing checking points.
Переглядів 1844 місяці тому
11 KV VCB Panel checking by given external sources & sharing checking points.
Single Phase Motor 1000RPM 24 Slot 6 Pole rewinding / Air conditioner outdoor fan motor rewinding.
Переглядів 1644 місяці тому
Single Phase Motor 1000RPM 24 Slot 6 Pole rewinding / Air conditioner outdoor fan motor rewinding.
Why heating is important plss rply sir
@@ramkrishanakundu1794 temporary heating during maintenance is a good practice to prevent moisture issues, but ensure it’s controlled and within safe temperature limits.
শুকরিয়া ❤
@@MDNurulIslamkhan-m5g ❤️
ব্রো ছুল্ টা তো ঠিক করে নিবেন
@@missjobaidaakter7052 ইঞ্জিনিয়ার দের চুল এমন ই থাকে 🥸
Please upload how to take intecont and gdc controller parameter back up
@@koushikkanp5515 ওকে চেষ্টা করব সময় করে দিব ইনসা আল্লাহ
Multimeter ta kothy connection korechen
Need configuration for 4 -20mA piezorezistive sensor
@@istiaqueahmedistiy104 দেওয়ার চেষ্টা করব ভাই
Палец вышел из чата
No, its work well
Use your eyes
😂
“If you’re using a ceramic fuse that’s transparent, you can usually check it visually to see if the fuse wire is broken. But if the fuse wire is broken from the cover and not visible, you can use this methods. If fuse glass is not transparent then visual inspection is not possible right?
But still good idea
মেকার দিয়ে টেস্ট করার কত প্রকার ধরন আছে একটু এই বিষয় নিয়ে কিছু বলতেন
sites.google.com/view/pervez-ei-automation/instruments
মেকারের কত প্রকার টেস্ট আছে
sites.google.com/view/pervez-ei-automation/instruments
How can I change the recipe and target weight? in recipe
How can I change the recipe and target weight? in recipe
❤❤❤❤ nice sir
স্যার এই দুইটা মটরের রোটেশন কি একইভাবে ঘুরবে নাকি বিপরীতমুখী ঘুরবে
বিপরীত মুখী
ধন্যবাদ স্যার
স্যার বিপরীতমুখী ঘোরার কারণটা যদি একটু ব্যাখ্যা করতেন তাহলে ভালো হতো
how can i check to know the panel current rating and other factors?
You have to enter into the parameters to know the value. So, download a manual and find out what you need and go throughout. Soon ill upload a details video in my channel. Thanks
What's up number also
Please share your mail id plz
Pervez.cement@gmail.com
Very informative
Glad it helped!
why are you not using Linux at some point windows will definitely crash according to me it's a major risk.
What a bullshit
@@vadeo17 what’s wrong?
ধন্যবাদ স্যার ❤
Welcome ❤️
স্যার কম্প্রেসার রানিং অবস্থা যখন লোড হয় তখন নির্দিষ্ট একটাবার এ গিয়ে আনলোড হয় তখন কম্প্রেসার বন্ধ হয় কিন্তু স্যার আনলোড অবস্থায় যাওয়ার পরও কম্প্রেসারের বার অটোমেটিকলি বাড়তে থাকে এইটার সমাধান কি হতে পারে বললে একটু উপকৃত হতাম
@@rabbikhan4295 কম্প্রেসার যখন আনলোড অবস্থায় থাকা সত্ত্বেও বার (প্রেসার) বাড়তে থাকে, এটি একটি সিস্টেম ত্রুটির বা কনফিগারেশন ইস্যুর নির্দেশ করতে পারে। এর সম্ভাব্য কারণ এবং সমাধানগুলির মধ্যে কয়েকটি হলো: প্রেশার সুইচ বা সেন্সর ত্রুটি: কম্প্রেসারের প্রেশার সুইচ বা সেন্সর সঠিকভাবে কাজ করছে না। এটি লোড এবং আনলোড পয়েন্ট সঠিকভাবে পড়তে পারছে না। সমাধান: প্রেশার সুইচ বা সেন্সরের সঠিকতা পরীক্ষা করুন এবং প্রয়োজনে প্রতিস্থাপন করুন। চেক ভালভ (Check Valve) সমস্যা: চেক ভালভ ঠিকমতো কাজ না করলে, কম্প্রেসার বন্ধ থাকলেও সিস্টেম থেকে প্রেশার ফিরে আসতে পারে, যার ফলে বার বাড়তে থাকে। সমাধান: চেক ভালভ পরীক্ষা করুন এবং প্রয়োজন হলে মেরামত বা প্রতিস্থাপন করুন। এয়ার লিকেজ: কোনো লিকেজ থাকলে কম্প্রেসার বাড়তি কাজ করতে পারে। সিস্টেমের কোথাও এয়ার লিক আছে কিনা তা পরীক্ষা করা দরকার। সমাধান: পুরো সিস্টেমে লিকেজ চেক করুন এবং লিক থাকলে তা ঠিক করুন। অ্যান্টি রিসাইক্লিং টাইমার (Anti-recycle timer): অনেক সময় কম্প্রেসারে অ্যান্টি রিসাইক্লিং টাইমার সঠিকভাবে সেট না করা থাকলে, আনলোড হওয়ার পরও প্রেসার বেড়ে যেতে পারে। সমাধান: টাইমার সেটিংস সঠিকভাবে কনফিগার করুন। কন্ট্রোল সিস্টেম বা পিএলসি ত্রুটি: পিএলসি বা অটোমেশন সিস্টেমের ত্রুটির কারণে কম্প্রেসার আনলোড হওয়ার পরও সঠিকভাবে নিয়ন্ত্রণ করতে না পারে। সমাধান: কন্ট্রোলার এবং পিএলসি প্রোগ্রামিং চেক করুন। এই সমস্যাগুলো একবার পরীক্ষা করে দেখা উচিত। যদি নিজে সমস্যা সনাক্ত করতে না পারেন, তাহলে একজন বিশেষজ্ঞকে দিয়ে পুরো সিস্টেমের ডায়াগনস্টিক করতে পারেন।
❤
আসসালামুয়ালাইকুম স্যার স্যার শিল্ড ক্যাবল কেন ব্যবহার করা হয়?একটু বললে ভাল হতো।
@@rabbikhan4295 মূলত দুইটি কারণে বাবহার করা হয় । ১. Any external mechanical আগাত থেকে রক্ষা করার জন্য । ২. এক্সটার্নাল ইলেকট্রোমেগনেটিক ইন্টারফারেন্স যেন না হতে পারে সে জন্য ।
একটু বুঝিয়ে বললে ভাল হত
@rabbikhan4295 তাহলে একটি ভিডিও বানিয়ে দেওয়ার চেষ্টা করব । যেন ক্লিয়ার বুজানো যায় ।
Hi sir always use sketch drawings for your explanation many dont understand Gujarat
Ok brother
ভাই মেইন মিটারে বিল বেশি আসে কেনো
@@mrsujonyt420 check the wiring, confirm the wiring is as per the drawing in meter.
@@Pervezaislam কাজ আরেক জনে করছে ১০/১৫ হাজার বিল আসে pfi বন্ধ করে দিছে মালিক, তবুও বিল বেশি আসে এখন কি মেইন মিটার চেঞ্জ করবো যতটুকু বুঝলাম আর ইঞ্জিনিয়ার ধারা চেক দিছে কিন্তু কোনো সমস্যা নেই আমি এখন বলতেছি যে মেইন মিটার চেঞ্জ করে দিই শুধু মটর চলে আর সিঁড়ি ঘর আর নিচের এক ফ্লাট চলে মাসে মেইন মিটারে বিল আসে ১৫ হাজার টাকা কি করবো এখন ?
Same video Hindi me bnao na sir
@@MukeshVerma-so3me ok
❤❤❤
Hi
নব কখন কত ভোল্টে রাখতে হবে?
@@sharifhossain8830 always 5000?
5000v
@@Pervezaislam মোটরের ক্ষেত্রে কততে রাখতে হবে?
@@sharifhossain8830 For three phase motor 1k for single phase motor 500v /1k
Tnx ❤️
Wonderful ❤❤
Thanks bhai
Thank you bro
@@jaheerjamadar5200 welcome
Can you share software configview download Please eng
@@user-yd1ij2tp6d you can download from online
Boss kuno load na thakleu ki manually doranu jabe
Yes brother
Boss capacitor option gular to ace na @@Pervezaislam
Please send your phone number
Hi can y help me Default #13 What is this problem
Local me chal Raha hai but remote me nahi chal Raha hai please help me
@@susantakar3193 you have to change some parameters for remote run. AI setting check and then try
@@Pervezaislam kaise korte hai
Details me boliye ji
@@susantakar3193 ua-cam.com/video/oyijdSOZ5T8/v-deo.htmlsi=WrKr_4yBQ1ULOP95
हिंदी में एक बार कर दीजिए सर 👏
ok
Hindi me batana chahiye tha n Bhai Sahab ye kon sa language h sir
@@jiyaulhaque9313 bangalaa
Thanks ❤
Welcome ❤️
What is the line thickness?, L+,N, V1,2,3 , Il etc...
I’m not sure what you wanted to know?
@@Pervezaislam wire SQ(awg)
1.2 RM or 1.5RM Will be good
@@Pervezaislam every wires 1.25 or 1.5 SQ?!
@user-me3do7gh7q hmm no issue
Encoder
Yes
हिंदी भाषा में बताइए
Ok
Thanks sir
Tomar kachhe kaj paya jabe Ami akhon benglore ACB,vcb, service korchhi megger kaj korchhi inshallah ❤️ West Bengal theke apni
Im from Bangladesh
Good video
@@EI-sd9uy thanks
Para que tipo de maquina es
Compressor
Assalamualaikum vai apnar WhatsApp number ta dile valo hoto.
আপনার নাম্বারটি দেন
Setting password ki? Blur korsen kno?
১২৩৪৫৬
@@Pervezaislam thank you so much
CT capacity koto?
1000/1A
Sir iske bare m detail m video bnaye..
ok