- 453
- 157 095
Javeed HVAC Technician
Приєднався 23 лис 2020
Javeed Ahmed
Created by:-
1)Antarctica HVAC Channel By Javeed Ahmed !
2)Javeed HVAC Technician
Working as a HVAC Service Field||Chiller||Ac||Make Bluestar||Carrier||Trane||Daikin||Maintenance||Field Work. Technician Since 2010 To Till Date
Contact :- 9008816066
Email Id :- javeedahmedjra06@gmail.com
Our Vision:-
1)To Help All The AC Operation & Maintenance Technicians,HVAC Field Employees To Gain The More Information about Related To Air Condition Products, Models Information through
My Vedios
2) Javeed Ahmed Vlogs
Facebook
Instagram
UA-cam
Created by:-
1)Antarctica HVAC Channel By Javeed Ahmed !
2)Javeed HVAC Technician
Working as a HVAC Service Field||Chiller||Ac||Make Bluestar||Carrier||Trane||Daikin||Maintenance||Field Work. Technician Since 2010 To Till Date
Contact :- 9008816066
Email Id :- javeedahmedjra06@gmail.com
Our Vision:-
1)To Help All The AC Operation & Maintenance Technicians,HVAC Field Employees To Gain The More Information about Related To Air Condition Products, Models Information through
My Vedios
2) Javeed Ahmed Vlogs
UA-cam
Low Economizer transducer Alarm fault Find out #chiller #electrical #hvac
Here are some potential causes and troubleshooting steps for a "Low Economizer Transducer Alarm Fault" in an HVAC system:
*Potential Causes*
1. Faulty or damaged economizer transducer
2. Incorrect transducer calibration
3. Low air pressure or flow rate
4. Clogged or dirty air filters
5. Incorrect wiring or connections
6. Sensor malfunction or drift
7. Incorrect configuration or settings
8. Low signal strength or noise interference
9. Transducer range or scaling issue
10. System software or firmware issues
*Troubleshooting Steps*
1. *Check transducer*: Inspect the transducer for damage, corrosion, or wear. Replace if necessary.
2. *Calibration*: Verify transducer calibration. Consult manufacturer's instructions.
3. *Air pressure and flow*: Check air pressure and flow rates. Ensure they're within recommended ranges.
4. *Air filters*: Inspect and clean or replace air filters as needed.
5. *Wiring and connections*: Verify wiring and connections are secure and correct.
6. *Sensor check*: Inspect sensors for damage or malfunction. Replace if necessary.
7. *Configuration and settings*: Review system configuration and settings. Ensure they match manufacturer recommendations.
8. *Signal strength*: Check signal strength and noise interference. Use signal amplifiers or filters if necessary.
9. *Transducer range*: Verify transducer range matches system requirements.
10. *Software/firmware*: Update system software or firmware if necessary.
*Alarm Reset Procedures*
1. Acknowledge the alarm.
2. Identify and address the root cause.
3. Reset the transducer or sensor.
4. Verify system operation.
5. Clear the alarm.
*Recommended Tools and Resources*
1. Manufacturer documentation
2. System schematics
3. Multimeter
4. Pressure gauge
*Safety Precautions*
1. Ensure system shutdown before performing maintenance.
2. Wear personal protective equipment (PPE).
3. Follow lockout/tagout procedures.
4. Verify electrical safety.
*Potential Causes*
1. Faulty or damaged economizer transducer
2. Incorrect transducer calibration
3. Low air pressure or flow rate
4. Clogged or dirty air filters
5. Incorrect wiring or connections
6. Sensor malfunction or drift
7. Incorrect configuration or settings
8. Low signal strength or noise interference
9. Transducer range or scaling issue
10. System software or firmware issues
*Troubleshooting Steps*
1. *Check transducer*: Inspect the transducer for damage, corrosion, or wear. Replace if necessary.
2. *Calibration*: Verify transducer calibration. Consult manufacturer's instructions.
3. *Air pressure and flow*: Check air pressure and flow rates. Ensure they're within recommended ranges.
4. *Air filters*: Inspect and clean or replace air filters as needed.
5. *Wiring and connections*: Verify wiring and connections are secure and correct.
6. *Sensor check*: Inspect sensors for damage or malfunction. Replace if necessary.
7. *Configuration and settings*: Review system configuration and settings. Ensure they match manufacturer recommendations.
8. *Signal strength*: Check signal strength and noise interference. Use signal amplifiers or filters if necessary.
9. *Transducer range*: Verify transducer range matches system requirements.
10. *Software/firmware*: Update system software or firmware if necessary.
*Alarm Reset Procedures*
1. Acknowledge the alarm.
2. Identify and address the root cause.
3. Reset the transducer or sensor.
4. Verify system operation.
5. Clear the alarm.
*Recommended Tools and Resources*
1. Manufacturer documentation
2. System schematics
3. Multimeter
4. Pressure gauge
*Safety Precautions*
1. Ensure system shutdown before performing maintenance.
2. Wear personal protective equipment (PPE).
3. Follow lockout/tagout procedures.
4. Verify electrical safety.
Переглядів: 159
Відео
How to Troubleshoot Low oil level alarm in 30Xa carrier chiller #maintenance #chiller
Переглядів 3474 місяці тому
If a 30XA Carrier chiller displays low oil pressure immediately after startup, it may indicate: 1.Low oil level: Check the oil level and top it off if necessary. 2.Clogged oil filter: Inspect and replace the oil filter if it's dirty or clogged. 3.Faulty oil pump: The oil pump might be malfunctioning or failing to generate sufficient pressure. 4.Worn or damaged bearings: Bearing wear or damage c...
How to replace Oil Filter in 30XA Carrier Chiller #maintenance #chiller.
Переглядів 2464 місяці тому
To find out if the oil filter is blocked in a 30XA Carrier Chiller Compressor, follow these steps: 1. *Check the oil filter indicator*: Look for an oil filter indicator on the chiller's control panel or near the oil filter housing. If it's illuminated or shows a warning, it may indicate a blocked filter. 2. *Monitor oil pressure*: Check the oil pressure gauge or sensor reading. Low oil pressure...
30XA model Carrier Chiller Compressor Enable Desable Procedure #maintenance #chiller #hvac
Переглядів 1445 місяців тому
30XA model Carrier Chiller Compressor Enable Desable Procedure #maintenance #chiller #hvac
How to Check LG Split AC Compressor Pumping & Winding Failure #maintenance #Split ac#Meggar test
Переглядів 6855 місяців тому
How to Check LG Split AC Compressor Pumping & Winding Failure #maintenance #Split ac#Meggar test
30XA Carrier Chiller High Pressure Alarm Generated #maintenance #chiller
Переглядів 3325 місяців тому
30XA Carrier Chiller High Pressure Alarm Generated #maintenance #chiller
Chiller 630Amps MCCB installation done #maintenance #chiller #electrical #carrier.
Переглядів 556 місяців тому
Chiller 630Amps MCCB installation done #maintenance #chiller #electrical #carrier.
30XA Model Carrier Chiller Alarm Generated Rectify the Complent Quickly#chiller #maintenance.
Переглядів 1147 місяців тому
30XA Model Carrier Chiller Alarm Generated Rectify the Complent Quickly#chiller #maintenance.
30XA Carrier Chiller CFM Winding Check with meggar #maintenance #hvac #electrical #chiller
Переглядів 1377 місяців тому
30XA Carrier Chiller CFM Winding Check with meggar #maintenance #hvac #electrical #chiller
30XA Carrier Chiller CFM Bearing 6205 DE/NDE Replace Done.#maintenance #hvac #carrier #chiller
Переглядів 407 місяців тому
30XA Carrier Chiller CFM Bearing 6205 DE/NDE Replace Done.#maintenance #hvac #carrier #chiller
How to Parameter Units Change in 30XA Carrier Chiller Unit #maintenance #hvac #chiller.
Переглядів 1798 місяців тому
How to Parameter Units Change in 30XA Carrier Chiller Unit #maintenance #hvac #chiller.
How to Communication Issues rectified 30XA Carrier Chiller #maintenance #hvac #chiller.
Переглядів 1799 місяців тому
How to Communication Issues rectified 30XA Carrier Chiller #maintenance #hvac #chiller.
How to fault finding Rotary Compressor tripping issue #ac #maintenance #hvac#troubleshooting
Переглядів 1259 місяців тому
How to fault finding Rotary Compressor tripping issue #ac #maintenance #hvac#troubleshooting
Digital Thermometer Repair #maintenance #hvac #AC#Chiller
Переглядів 579 місяців тому
Digital Thermometer Repair #maintenance #hvac #AC#Chiller
How to Solve 30XA Carrier Chiller Communication Issues #hvac #chiller #maintenance.
Переглядів 9919 місяців тому
How to Solve 30XA Carrier Chiller Communication Issues #hvac #chiller #maintenance.
FAHU Blower Bearing Block dismantling work #hvac#maintenance#Low side Equipment
Переглядів 4410 місяців тому
FAHU Blower Bearing Block dismantling work #hvac#maintenance#Low side Equipment
How to Check Solenoid Coil Faulty #Hvac#Carrier Chiller #maintenance.
Переглядів 1,5 тис.10 місяців тому
How to Check Solenoid Coil Faulty #Hvac#Carrier Chiller #maintenance.
Heavy Capacity FAHU Fault Finding #hvac #AC maintenance #chiller
Переглядів 22311 місяців тому
Heavy Capacity FAHU Fault Finding #hvac #AC maintenance #chiller
Economizer Function explained. how to Work #chiller #hvac maintenance # AC technician
Переглядів 72511 місяців тому
Economizer Function explained. how to Work #chiller #hvac maintenance # AC technician
DDC Panel CPM Board Communication Issues#Chiller#hvac maintenance #Pumps
Переглядів 83Рік тому
DDC Panel CPM Board Communication Issues#Chiller#hvac maintenance #Pumps
Compressor T Joint O Ring Replacement Work #Chiller#maintenance#hvac
Переглядів 1,5 тис.Рік тому
Compressor T Joint O Ring Replacement Work #Chiller#maintenance#hvac
Chiller Main MCCB tripping issues Solved #hvac#Chiller#Maintenance#javeedhvactechnician
Переглядів 191Рік тому
Chiller Main MCCB tripping issues Solved #hvac#Chiller#Maintenance#javeedhvactechnician
Split AC Universal PCB installation #maintenance #ac #hvac #repair job
Переглядів 61Рік тому
Split AC Universal PCB installation #maintenance #ac #hvac #repair job
Temperature (T1 & T3) Details of Carrier Split Unit#AC#Maintenance# Javeedhvactechnician.
Переглядів 343Рік тому
Temperature (T1 & T3) Details of Carrier Split Unit#AC#Maintenance# Javeedhvactechnician.
FAHU Heat recovery Wheel Not work properly
Переглядів 461Рік тому
FAHU Heat recovery Wheel Not work properly
Carrier 30XA Model#Oil transducer alarm issue Rectified#Chiller hvac@javeedhvactechnician7760
Переглядів 310Рік тому
Carrier 30XA Model#Oil transducer alarm issue Rectified#Chiller hvac@javeedhvactechnician7760
hvac Preventive maintenance #Primary Pump Bearing Sound Issue Resolved#chiller maintenance
Переглядів 259Рік тому
hvac Preventive maintenance #Primary Pump Bearing Sound Issue Resolved#chiller maintenance
hvac Preventive Maintenance#Air Cooled Chiller Maintenance #Blue Star Make
Переглядів 37Рік тому
hvac Preventive Maintenance#Air Cooled Chiller Maintenance #Blue Star Make
DDC Panel UTC Carrier Make#hvac chiller maintenance # analog digital parameters
Переглядів 62Рік тому
DDC Panel UTC Carrier Make#hvac chiller maintenance # analog digital parameters
Honeywell Digital Thermostat Unlock Procedure#ac maintenance #hvac maintenance #javeedhvactech.
Переглядів 127Рік тому
Honeywell Digital Thermostat Unlock Procedure#ac maintenance #hvac maintenance #javeedhvactech.
India me
Dubai
Sir mujhe chiller plant me job Krna he company ka name batao
Kon se country me krna hi sir apko
Good working sir
Thanks
Running inhibit so many time in display
Thank you ❤
Welcome sir
Bhai ek cooler freeze protection ke bare mei bana do ya mujhe reply karke bata do solution kya hai is alarm ka
Ji zaroor bhai
🎉🎉🎉
Thank
No nc kahan hai ismein
Bhai ye model me NO NC ni rehta hum log adon block use krke use krlena
Carrier 30xa All transducer same DC voltage ?
Yes
Nice information
Thank
Not bad
🙏
Chiller kA compressor direct chalo kar sakte hai
Ha sir chalu karsakte hai. Magar compressor safety ni hai kyu ki electrical area me 3 phase power supply ke wajah se heat zyada ho jayega aur cables melt hone ke chance bhut hote hai.
@javeedhvactechnician7760 Ok sir agar Pura video banaiyega to tura acha hum logo ko be learn kar skate hai chiller ki bare me
@jai.shree.Ram-sena108 Ha sir zaroor banaunga.
brother how to on&off chiller system and manua&auto system plz make video
Ok sure sir
Super bro ❤
Thank you sir
Ap ispe ek aur video banaiye kaise kaise check karna hai kitna kya reading show karega to kharab hai kitna kya reading show karega to sahi hai aisa bhi video banaiye to aur easy ho jayega check karna
Mere site par skm chiller hai uska bhi low amps ka alarm aa raha hai usme bhi same check karne se problem solve ho jayega ya aur bhi kuch check karna padega
CT check kro, gas bi check kro
Cable connection tight kro
@@javeedhvactechnician7760 thik hai karke dekhta hu
@TATABIRLA0001 Ok done
@@javeedhvactechnician7760 agar ap presonaly guide kar sakte hai whstasp se to mai apna number du kya Same problem hai mere chiller me but kaise kaise check karna hai iske bare me idea nhi hai
Nice video , But in thermostate do we have both option to use it either with actuator or blower fan speed of fcu is it correct
Ya
Any thermostat we can use both actuator & fan Speed. But in this Vedio, this actuator used for dampers open/closed purpose
Sir compressar hi ampyer ya obehar lod aa raha hai tip kar raha hai kay problam hai
Gas leak hai kya check kro
@@MohitM-j9t compressor ka amps check kro, sb power & control wiring ko tight kro
Sir cr kay hai
Cutoff ratio
Assalam alaikum sir carrier model mai vaccume kage tab display mai suction aur discharge ki reading kya honi Chahiye thanks.
Valekumassalam, carrier chiller me -30 tak dikhata hai uske baad hum microns gauge laga ke check krlena hi
Aap bi notice kro jb mi vacuum krne ke timenotice kiya -30 to 50 tk dekha tha
Sir aik mukamal trane k display pa video bnayo
Ok sir
Stop batan puse Karne ke bad chillar band ho gya ab Chalu karna hai to kya kare
Release kro start hojayega
ek me jyada continioti jyada Bata raha 536 ooo kharab hai please Jawad dijiye
good sir
Thnks
I have Alarm under voltage power 1 failure how to reset plz answer
First you check the line voltage. Standard imbalance voltage is 2 V if higher than this voltage dont start the machine need electrical maintenance
I have also same issue. loss of communication with fan board alarm
Very informative thank you
Aap Jo Bata rahe sahi hai lekin ek aur doubt tha ki non inverter AC mein Kitna length Tak pipe ho sakte hain inverter AC mein kitne len Tak pipe poochh sakte kar sakti hai use kar sakte hain maximum
Acccha sir
Sir is display me kaise tem set karte hai or suscon pressar and discharg pressar kaise chak karte hai
If you need to get this repaired then contact me.
Ok sir How much cost
Bhai sf problam aa raha hai kay kare
@@MohitM-j9t Agar photo raha to sent karo bhai
@@javeedhvactechnician7760 bhai mobile le jana alau nahi hai
@MohitM-j9t Accha to ok aap lek kr rakho
What is the range?
50psig range discharge & oil pressure
In kpa 344
Ok thanks
what is the range between Oil pressure -suction pressure
ODP =op-sp is the formula right
5×1 kaise aya?
5 temperature ka delta difference hi aur 1 ake specific water of constant pressure ka hi
Ye to multiply mai hoga?
@amzadali9142 Poora vedio me iska calculation hi
Link please
Mass flow rate ki value?
Bhai jee ye batau ki Mera chiller me 4 compressor hai 2 chaeta hai 2 band hai kaise pata chalega ki q band hai
Tandom circuit hai kya
Mera air tipe chiller hai or scrol compressor hai isci tipe ka display hai to usme 4 compressor hai 2 chaeta hai 2 band hai to kaise pata chalega ki compressor kis karn se trip hai
@@javeedhvactechnician7760 nahi samja aap kay Bata Rahe hai
@MohitM-j9t Aap password put karo aur compressor ka status check kijiye
Aap ek kaam kijiye pehle compressor running me chal rahe the kya
Ya digram hai to send Kar do
Bhai is display ka Pura video Bana ki dekho kon sa batan kay Kam karta hai
Bhai scrol compressor ka Susan or discharge kitna hota hai
Aap pressure ki baat kr rahe ho kya
@@javeedhvactechnician7760 susonpresser and discharge presar
@MohitM-j9t Pressure to refrigerant based hota hi Like R22,R134a, R410a etc
@@javeedhvactechnician7760 r 407 ka
@MohitM-j9t Suction pressure:65-70psig Discharge pressure:250 to 350psig Standing pressure:150psig
Bhai display ka para miter ka full video banau
Zaroor banaunga
Very informative video
Thnks you
Sir Trane ke Brine chiller ka display data per video banaiye please
Ha zaroor
Pls MVN7510 k connection bath sakthe ho
Ye model ka to 0 to 12 v ka step-down transfermer use karlena hai humko
Sir if error shows High EWT and compressor trip , whats the solution
Replace it
Sensor
Sir hamare yaha child water line par ye valve laga hai but vo yato off ho jata ya fir band ho jata hai temp ke according kaam nahi karta hai
Check kijiye
@@golu61350 Ye valve fcu ke chw line me laga hi kya
LLSV working with video
Brother please show symbols sign on valves and acthators using pxm20
In this chiller temperature error coming what may be the reason
Sensor faulty check properly
Running limit alarm? Reason ? solution?
Chiller capacity
@@javeedhvactechnician7760 300 TR
@@mehmoodulhassan9442 evry chiller 5or 6 alarm reset option so more than 6 factory authorised required
❤❤❤❤
Good
Bahut Khub
Thnks sir