- 130
- 199 039
Power System Engineering Solution (PSES)
Приєднався 6 гру 2012
Power system protection control & Protection relay, equipment testing commissioning activities
MGTR GPS connected with Freja300 for end to end test
MGTR GPS connected with Freja300 for end to end test
Переглядів: 23
Відео
P546/P543 Distance Blocking scheme check
Переглядів 7114 днів тому
P546/P543 Distance Blocking scheme check
CT Secondary injection test in Freja300
Переглядів 29614 днів тому
CT Secondary injection test in Freja300
P546/P543 Current Reverse Protection DEF
Переглядів 10214 днів тому
P546/P543 Current Reverse Protection DEF
P546/P543 DEF/Aided DEF POR and Blocking scheme check
Переглядів 13514 днів тому
P546/P543 DEF/Aided DEF POR and Blocking scheme check
Micom S1 Agile software installation in PC
Переглядів 7314 днів тому
Micom S1 Agile software installation in PC
P546/P543 SOTF Externalplus Function test # Freja300
Переглядів 14521 день тому
P546/P543 SOTF Externalplus Function test # Freja300
P546/P543 SOTF Pole Dead Function test #Freja300
Переглядів 12821 день тому
P546/P543 SOTF Pole Dead Function test #Freja300
RTKUC625 Annunciator LED input contact settings changed
Переглядів 37Місяць тому
RTKUC625 Annunciator LED input contact settings changed
ISA CBA1000 CB timing test 380kV GIS @ABB
Переглядів 1222 місяці тому
ISA CBA1000 CB timing test 380kV GIS @ABB
ISA CBA1000 communication with PC and CB contact resistance test
Переглядів 892 місяці тому
ISA CBA1000 communication with PC and CB contact resistance test
Circuit breaker test @ABB HD4 13.8kv switchgear
Переглядів 1502 місяці тому
Circuit breaker test @ABB HD4 13.8kv switchgear
Busbar stability test @ABB 380kv_GIS by primary injection
Переглядів 2982 місяці тому
Busbar stability test @ABB 380kv_GIS by primary injection
REG-D AVR tap changer relay function check
Переглядів 1392 місяці тому
REG-D AVR tap changer relay function check
7UT633 relay communicate with PC #Siemens
Переглядів 1042 місяці тому
7UT633 relay communicate with PC #Siemens
7UT633 transformer protection relay by HMI setting review
Переглядів 1037 місяців тому
7UT633 transformer protection relay by HMI setting review
7UT632 Transformer differential relay Power supply issues repair #Siemens
Переглядів 2277 місяців тому
7UT632 Transformer differential relay Power supply issues repair #Siemens
MVAJ104 Trip relay testing procedure
Переглядів 1577 місяців тому
MVAJ104 Trip relay testing procedure
MRTP Pilot wire supervision relay #AREVA
Переглядів 797 місяців тому
MRTP Pilot wire supervision relay #AREVA
MGTR GPS connected with Freja 300 #Megger
Переглядів 1127 місяців тому
MGTR GPS connected with Freja 300 #Megger
Mimic panel for power distribution system
Переглядів 667 місяців тому
Mimic panel for power distribution system
RED670 relay to Media converter communication failure indication
Переглядів 817 місяців тому
RED670 relay to Media converter communication failure indication
BCU relay installation in LCC panel@ ABB
Переглядів 1408 місяців тому
BCU relay installation in LCC panel@ ABB
Pls upload full video of communication between freeja 300 and laptop
GOOD VIDEO SIR, can pls provide the copy of test report shown in the video.
Thanks for uploading informative videos .this type of videos help many people.good work .
Hi sir please send relay file
Very. Usefull video upload more videos.
Kindly explain what is I>>>, I>>, I> and Ip> and full form in Siemens siprotec relays
Sir i need testing procedures for p543 and red670 , p343 generator protection with settings guidance , protection fundamental concept or philosophy. Pls provide sir
Send me email id
Thanks for uploading video very informative and helpful video make some more videos to help others
What is the reason for this green power indicator flashing continuously
Very informative
Excuse me, what is the resistance of the opening triangle
which company the CT analyzer? Omicron?
COULD YOU PLEASE SHARE DOCUMENTS FOR SETTING
523 O'Hara Cliff
👍
Great
Boss you are great very informative make more videos plz
I will try my best
I started my career with ASEA, later ASEA Brown Boveri (ABB) at 18 yo in 1984 at Lilydale Victoria Australia. Around 7 years later, I joined the Service Dept and travelled most of Australia doing installation and service work. This was the best company I have worked for and the best experience I ever had. I only left because they moved their operations too far away. Great memories.
Hello, I'm very sorry to disturb you on the weekend. I have a question that has been bothering me: after changing the settings of the protection relay, do I still need to conduct a test? For example, the overcurrent protection has been changed from 5A to 6A. Do you still need to test the relay protection? Thank you.
Yes, when you change any settings, current or time, make sure relay works according or not
If recently tested, this relay is working fine then no need to test
@@Powersystemengineeringsolution Yes, the protection relay has been running normally, but due to load changes, the parameters of the overcurrent protection need to be modified. So the question is: How to ensure that the modified parameters are entered correctly?
Hi.. provide ur contact details
Thank you sir for increasing our information .
Thank you Soo much very informative video .keep make more videos upload .
Sure 👍
Thank you for good explain
I have a problem regarding power measurements the relay reads all currents and voltage correctly but power gives values that not match with injection
Check relay setting current and voltage and frequency and wiring connections, injection source measurements
Hello, what is the Zs? How we find 1.5 and 1. Can anyone explain?
Zero sequence filter, please read the manual
How you made connection in changeover contact (15,16)
It's in manual. Please read the manual also
Can I have the download link, please?
Yes, you can download it online
Can you connect two currents in parallel with different frequencies? I don't understand.
You can impose R phase into the Y phase current with different frequency, but phase angle should be same
Can someone take training at your workshop
Hello Sir where are you based ?
secondary of your VT is going input for your CPC 100 not voltage source , for clarification appreciated your demo as most of my testing is not allowed camera phones that's good demo anyways
Hi, Can u pls share the PSD graph creator or that psd graph file.
Very good Sir
Why we are taking 1amp and 2kv...on what factor is depend? Suppose my Ct is 3200/5 rating..then how much should i take voltage and current?
How can we measure the winding resistance of VT
Very Good Video Sir.
Is it on the secondary? How come
👍👌 good explanation
Pls upload more video about Siemens relay sir
7SD522 line differential testing video available in the list
What is make of relay kit
Freja300, megger company
Good job brother, how you are accessing CT primary in this GIS?
Thank you
In ABB GIS if you close the earth switch GIS primary make short circuit body with the help of one plate out side of the earth switch so you can access the primary by open the this plate and connect your cable
its LV system i guess
Now I am working junior testing engineer could you please share about mail id
Sir plz could you send me excel sheet. Thanks
Sir, can you give me the contact resistance standards of medium voltage circuit breakers?
I don't have you to compare it with the SAT report
Bro post videos in tamil if possible it will be easy to understand.
Good Explanation, but take care using safety hand gloves, one more thing during test CT secondary wire possible to remove while clamp meter insertion, it's dangerous sir
Thank you
Hi u r slang smilier to tamil