- 49
- 342 347
HYMAX USA
United States
Приєднався 16 чер 2014
HYMAX designs and manufactures innovative coupling and repair clamp solutions for water and wastewater applications.
The revolutionary HYMAX coupling products are used worldwide with more than 2 million installations in North America alone. Krausz holds more than 100 international patents for a range of water piping repair and coupling solutions that are durable, easily implemented and minimize installation time.
In 2018, Krausz Industries, the manufacturer of HYMAX, was purchased by Mueller Water Products.
Mueller Water Products, Inc. (NYSE: MWA) is a leading manufacturer and marketer of products and services used in the transmission, distribution and measurement of water in North America. Mueller’s broad product and service portfolio includes engineered valves, fire hydrants, pipe connection and repair products, metering products, leak detection, and pipe condition assessment.
The revolutionary HYMAX coupling products are used worldwide with more than 2 million installations in North America alone. Krausz holds more than 100 international patents for a range of water piping repair and coupling solutions that are durable, easily implemented and minimize installation time.
In 2018, Krausz Industries, the manufacturer of HYMAX, was purchased by Mueller Water Products.
Mueller Water Products, Inc. (NYSE: MWA) is a leading manufacturer and marketer of products and services used in the transmission, distribution and measurement of water in North America. Mueller’s broad product and service portfolio includes engineered valves, fire hydrants, pipe connection and repair products, metering products, leak detection, and pipe condition assessment.
HYMAX VERSA 78" ZOOM case study
Denny Setzer, HYMAX Regional Sales Manager, interviews Dan Temple from A&B Irrigation, Rupert, ID, on a HYMAX VERSA 78" installation.
Переглядів: 316
Відео
HYMAX GRIP SwivelJoint case study AZ
Переглядів 1854 роки тому
HYMAX sales manager Stan Pachorek interviews Operations Mgr. Don Bohiler from Prescott Valley, AZ, about using the Swiveljoint
CASE STUDY, HYMAX GRIP T - Charlottesville, VA
Переглядів 1524 роки тому
Case Study - Using the HYMAX GRIP T. Vince Mc Caffrey, HYMAX territorial sales manager, interviews Jason McIlwee, P.E., Utilities Engineering Manager, Department of Utilities, City of Charlottesville, VA
HYMAX GRIP SWIVELJOINT® case study
Переглядів 7064 роки тому
Marty Watts, Assistant Superintendent, City of Cumberland, MD, speaks about using the HYMAX GRIP SWIVELJOINT as a solution for difficult field pipe repair situations. Interviewed by Vince McCaffrey, HYMAX Territory Sales Manager.
KRAUSZ REPAMAX "Deserted Island" video
Переглядів 1804 роки тому
Short promotional cartoon-style video featuring the KRAUSZ REPAMAX unique wide-range coupling (40-1800 mm)
HYMAX GRIP installation video
Переглядів 17 тис.4 роки тому
3D animated installation video for the HYMAX GRIP coupling restraint by KRAUSZ.
Hymax Versa "Deserted Island" Promo
Переглядів 1,2 тис.4 роки тому
What if you had to take only ONE pipe repair product to a deserted island? What product would you choose? The answer in this enchanting cartoon-style video.
HYMAX Digital Application Selection Guide - DASG
Переглядів 4894 роки тому
DASG is a useful tool that enables users to find the optimal HYMAX solution to their field situation - anytime and from anywhere!
HYMAX 2 Installation Video
Переглядів 8 тис.4 роки тому
Step by step installation of the HYMAX 2 wide-range coupling (1.5"-12") with the FLIP GASKET. For exact instructions refer to the written instructions supplied with the product. For product specifications and full product selection go to - krauszusa.com/products-main/hymax-2
HYMAX VERSA Encapsulation 1.5"-3"
Переглядів 1 тис.4 роки тому
Short product overview - HYMAX VERSA Encapsulation Wide-range wraparound coupling
HYMAX GRIP® Cut in Sleeve
Переглядів 9 тис.5 років тому
HYMAX GRIP® Cut in Sleeve CONNECTS AND RESTRAINTS plain pipe to MJ applications such as valves and hydrants, with only one bolt to tighten on the pipe
Hymax Grip Cut in Sleeve installation
Переглядів 1,3 тис.5 років тому
Installation of a 6" HYMAX GRIP Cut-in Sleeve, connecting plain pipe to water hydrant. Time of installation about 30 minutes from start to finsh.
Hymax Grip Cut in Sleeve installed
Переглядів 1,8 тис.5 років тому
Installation of a 6" HYMAX GRIP Cut-in Sleeve, connecting plain pipe to water hydrant. Time of installation about 30 minutes from start to finsh.
HYMAX BY KRAUSZ - IRRIGATION-GOLF VIDEO
Переглядів 6855 років тому
Promotional video that summarizes the benefits of HYMAX and HYJOINT product lines for the golf and irrigation markets.
Installation comparison - HYMAX coupling VS. MJ product
Переглядів 4 тис.6 років тому
Installation comparison - HYMAX coupling VS. MJ product
HYMAX 2 Next Generation Coupling Coming Soon!
Переглядів 1,6 тис.7 років тому
HYMAX 2 Next Generation Coupling Coming Soon!
HYMAX Large Diameter 14"-60" with only 4 bolts
Переглядів 2,7 тис.7 років тому
HYMAX Large Diameter 14"-60" with only 4 bolts
HYMAX Clamp Installation Instructions
Переглядів 3 тис.8 років тому
HYMAX Clamp Installation Instructions
Bonne technique d'installation facile
Without gasket how it will seal
Are you explaining this to 5th grader?
Ductile iron genius
Sizes of asbestos 200mm
Sir please send me your number where are you from and which city are you from?
How long can you use that size pipe before it gets worn out?
No shoring?
The way they dug the dirt, it didn’t need shoring.
Hi, Are you interested in pipe repair clamps/ sleeves?
Try to keep alignment for neat job.
Proper alignment is needed to fix the coupling ends of the pipe piece.
Collars of the pipe piece ends tighten by means of nut and bolts.
Amazing line of products in underground repairs of our Water Systems...so inovative,Tks Tom!!😀
How long do they Hymax's last under ground?
Do you have 30.25 inch like this one Jamal@adoc.ae
Do you have 30.25 inch for steel pipe Send me to Jamal@adoc
Is this type of clamp is applicable for 30.25 inch O.D. I want to use it to store the water leakage in the pipe gaps the gaps is about 25 mm and the flange size is equel to the pipe of. Both are same old. If ok please send me all data sheet and max. Pressure and temp.
Hrmmm. Seems relevant now. Wonder if there's more seismic activity than anyone wants to chat about?
Great commentary except for one part..The first one that was taken out wasn’t a butterfly valve. It was a gate valve. Butterflies are identifiable by the inside of the pipe and the offset valve nut.
Good thing Hymax was there to save the day, we sure know the city couldn’t do anything
lol . . . omg!😀
City council waterworks crews have been doing this type repairing long before fucking contractors don't comment on stuff you know fuck all about
That old Pipe Value was a GATE VALVE not a Butterfly Value......The RED PART on the New Pipe is BUTTERFLY Value..And on the Two ends of the New Pipe those things are Called DRESSER COUPLINGS....You slide the Dresser Coupling on the Pipe then put the Pipe in place then slide the coupling to the Center of the end of the Pipe...Then start tightening the bolts....The coupling is Tapered and has a Rubber Gasket in it....You just keep tightening it and the coupling will Squeeze the Rubber part Making a tight Seal..
We wrap the couplings with plastic sheeting to protect the gaskets from corrosion before backfilling
Lol sorry that was an old gate valve
Ye clamp kaha pr milega kitne ka hai mera whatsapp no. 9453130242 pe detel bheje please
How does the water stopper allow services not to be interrupted? There are services that are fed between the valves.
Well that was a ton of fun
You could do the Hymax even faster with a 20 volt impact and long socket 👍👍👍
i am working from water pipe line maintenance from qatar.. anybody can let know me any job same like that. i am site supervisor +97466696577
Lar c
Wheres the PPE? LOL FACE SHEILD GLOVES EAR PLUGS. AND PROPER SAW
According to American water that is the proper saw. They actually ban the use of a chop saw. While these chainsaws have their special uses I believe they are just as dangerous as a chop saw. Take it from someone who uses both,
Certain water company’s will not alow a demo saw at all not even on a cart to saw cut a road if its there job Ics saws are just as if not moor dangerous then a demo saw
get back in the office lol
Grew up near there and now doing a video on water utilities in St Louis. Nice job and nice video. (Have a drink for me at Ruddy’s)
That was interesting. Indiana PA checking in
Although the manufacturer does not recommend these can be used on ACP. Just torque with care and don’t go any tighter than needed to seal.
Well so I just a hymax fail on a commercial job with a 6” water main pipe. Probably $20k in damages plus whatever the owner decides to sue me for, let’s see how good of a “warranty” Krausz you have.
So what ended up being the cause of the failure. I’ve installed hundreds of these and never had one fail
The best fix for our situation is a three inch encapsulation fitting, but no one that I can find makes that in a three inch size, they start out at 4" and up, be cool if someone would design a stainless wrap style repair that would wrap around the bell and seal off
Jared Franklin ford meter make those they are the od of the bell for half of the warp around the y make them for pipe as small as 3/4 galvanized to work on leaks at coupling
OK, we are trying to find some kind of wrap that will place over the leaking bell, due to valve distancing and an extremely long flush route, we don't want to open the pipe, much better for us to leave pressurized with no interruption of service or water loss
Was wondering if the versa will wrap around a leaking bell joint and seal off
Hi Jared, the Versa will not wrap around a leaking bell joint, you need to saw the bell first and use the Versa to connect. Please go to krauszusa.com , see "ask our expert" on top of the page and leave any question you may have.
Please send me the details of the installation and the installation protocol and I will give you a working solution.
Ive never seen that style of sleeve before, is it retained on the DI nipple? Why not use megalugs or another mechanical joint style fitting?
See this video that explains the advantages of using this large diameter product - ua-cam.com/video/GY6_dFgk0lU/v-deo.html
Much easier to use 2 bolts to tighten, but yes it could slip.
Don't see any bends or fittings nearby...so, if you make oal of the valve and nipples as close as possible to the space you have....what can move?????.. if you fuck up ...use a spacer
Cool animation, very good job!
So much easier to use than the damn mechanical couplings
what a shame that job was using wood to support a ductile main city workers too Lol
It’s a gate valve not butterfly!
jijiji kijiji No that’s a butterfly valve it’s a gate valve yes but when it’s on the side it’s a butterfly valve
What do you expect from Kevin Lynn?
it is a resilient wedge valve. Butterfly has nothing to do with orientation. It is a type of valve where the disc turns to open instead of rising out of the way into the hump.
That's how it's done!!....good job by all
we still use the pvc bump coupling repair, very seldom tho because of the efficiency of the hymax, speeds things up considerably,
hey Josh, was wondering if the hymax non restraint can be reused after being in service then taken back out, had a situation where the hymax leaked, but was due to poor backfill, pipe settled and put the coupling in to much of a bind, installed all new materials to fix leak, hated to not be able to reuse after initial tightening
Hi Jared. Thanks for your question. Let me check with the experts at Krausz and I'll get back to you here.
They can be re used I had a 12 inch Hymax that we had in use for about a month and we dug it back up on the one side and connected straight into the valve and it sat in inventory for a few months and then got used again in a shopping center on its watermain. Worked like a champ. One thing I’ve learned with these couplings is to not tighten them any more then needed to seal or you can bend the ears where the bolts grab. Also these can be used on ACP but use at your own risk and torque carefully
excellent product, we use this product very often in our distrabution system, has never failed, easy to install, very very good product
Thanks Jared. We're glad you're enjoying the benefits of HYMAX GRIP.
Hi Jared - You can re-use the non-restraint HYMAX coupling for additional installations with the following condition: you must install the product on pipe with same Outside Diameter (OD) or smaller. If you have removed the inner layer gasket (in a product that has a 2-layered gasket) on either side of the coupling, you need to make sure that the new pipe's OD falls within the working range of the coupling. The HYMAX coupling's gasket has different working ranges for pre- and post-removal of the inner layer gasket, and in some cases you may remove the layer on one side of the coupling while leaving it on the product on the other side (depending on what pipes you are connecting). Visit this link for installation instructions for the long-body HYMAX (1.5" - 12") and pay special attention to step 5. krauszusa.com/wp-content/uploads/2016/09/II0033_B_Hymax_and_Long_Body_1.5-12_LETTER_LOW.pdf Can I ask you what pipe types and ODs you are working with?
Mostly pvc from 2 inch up to 12 inch, thank you much for helping me out with this
Great explanation . It is very helpful when troubleshooting a customer's needs that they know the OD for us and not the diameter. May I link your video to our youtube channel ?
+H R Prescott & Sons, Inc We're glad you enjoyed the video. Please feel free to link this to your UA-cam channel. All the best.