- 705
- 10 113 341
BE Technical
India
Приєднався 26 січ 2018
Hi friends.. Welcome to our channel. Myself D.Kalaiselvi working as an Assistant Professor in a reputed institution. I have more than 12 years of experience in teaching. My goal is to help the students to understand the concepts. It is my pleasure to share my knowledge with you guys through this platform.
I hope this will be helpful to build your career. Best wishes to all..
HAPPY LEARNING!!!
I hope this will be helpful to build your career. Best wishes to all..
HAPPY LEARNING!!!
Double Line to Ground Fault (L-L-G Fault) Derivation in power system analysis
Double Line to Ground Fault (L-L-G Fault) in power system analysis - Derivation
Переглядів: 547
Відео
Draw the transformer zero sequence equivalent circuits for the various winding connections.(N/D2013)
Переглядів 14228 днів тому
How to draw Zero sequence circuit of the Transformer in power system analysis. Draw the transformer zero sequence equivalent circuits for the various winding connections. (Nov/Dec-2013)
SINGLE LINE TO GROUND FAULT (L-G FAULT) Derivation - Power System Analysis
Переглядів 842Місяць тому
SINGLE LINE TO GROUND FAULT (L-G FAULT) Derivation
Two 11 kV,20 MVA, three phase star connected generators operate in parallel,.. L-G FAULT based prob
Переглядів 352Місяць тому
Two 11 kV,20 MVA, three phase star connected generators operate in parallel as shown in fig. the positive, negative and zero sequence reactance of each being respectively j 0.18,j 0.15,j .10 p.u. The star point of one of the generator is isolated and that of the other is earthed through a 2.0 ohm resistor. A single line to ground fault occurs at the terminals of one of the generators. Estimate ...
Determine the fault current and line voltage at 11KV bus under fault condition.
Переглядів 376Місяць тому
For the radial network shown in Fig. three phase Fault occurs at F. Determine the fault current and line voltage at 11KV bus under fault condition.
Calculate PU for the load. Draw the impedance diagram/ anna university solved problem / PSA
Переглядів 3972 місяці тому
Prepare a per phase schematic of the system in fig. and show all the impedance in per unit on a 100 MVA, 132 KV base in the transmission line circuit. The necessary data are given as follows. G1 : 50MVA, 12.2KV, X=0.15 pu. G2 : 20MVA, 13.8KV, X=0.15 pu. T1 : 80MVA, 12.2/161KV, X=0.1 pu. T2 : 40MVA, 13.8/161KV, X=0.1 pu. LOAD: 50MVA, 0.8 power factor lag operating at 154KV Determine the PU imped...
The one line diagram of the power System is shown in fig. the three phase power line-line Ratings
Переглядів 6742 місяці тому
The one line diagram of the power System is shown in fig. the three phase power line-line Ratings are given below. G1: 80 MVA, 22KV, X = 9% T1: 50 MVA, 22/220 KV, X = 10% T2 = 40 MVA, 220/ 22 KV, X = 6% T3, T4 = 40 MVA, 22/ 110KV, X = 6.4% Line 1= 200Kv X=121Ω Line 2= 110Kv X=42.35% Motor = 68.85MVA 20 Kv X=22.5% Load: 10 MVA, 4Kv. Draw an impedance diagram showing all impedance in per unit on ...
Draw the impedance diagram for the given fig. PSA / UNIT-1
Переглядів 4262 місяці тому
Draw the impedance diagram for the given fig. Power system analysis Unit 1 problem
Draw the reactance diagram for the power system problem 4 / Single line diagram
Переглядів 1,5 тис.3 місяці тому
Draw the reactance diagram for the power system shown in figure 11 (a) (ii). Neglect resistance and use a base of 100 MVA, 220 KV in 50 line. The ratings of the generator, motor and transformer are given below . Generator : 40 MVA, 25 KV, X" = 20% Synchronous motor : 50 MVA, 11 KV, X" = 30% Y Transformer : 40 MVA, 33/220 KV, X = 15% Y - Transformer : 30 MVA, 11/220 KV ( /Y ), X = 15% ....
OPEN CIRCUIT TEST FOR TRANSFORMER
Переглядів 973 місяці тому
Transformer no load test / open circuit test / OC test
Basic Logic gate 7432 practical experiment
Переглядів 953 місяці тому
practical IC experiment 7432 OR GATE
4 VARIABLE K MAP PROBLEM
Переглядів 2304 місяці тому
Reduce the following using karnaugh map f (A, B, C, D) = Σm (0,1,4,8,9,10)
Basic of Phase Locked Loop (PLL) Derivation of Lock in Range and Derivation of Capture Range
Переглядів 3114 місяці тому
Phase Locked Loop (PLL) Derivation of Lock in Range and Derivation of Capture Range
Three terminal Fixed voltage regulator
Переглядів 1204 місяці тому
Three terminal Fixed voltage regulator
VOLTAGE CONTROLLED OSCILLATOR / VOLTAGE TO FREQUENCY CONVERTOR
Переглядів 3534 місяці тому
VOLTAGE CONTROLLED OSCILLATOR / VOLTAGE TO FREQUENCY CONVERTOR
Design a digital Butterworth filter using Bilinear transformation method
Переглядів 2,5 тис.4 місяці тому
Design a digital Butterworth filter using Bilinear transformation method
DSP Most important topics 2021 regulation
Переглядів 6594 місяці тому
DSP Most important topics 2021 regulation
Ring main distributor based problem - Anna university solved problem
Переглядів 1304 місяці тому
Ring main distributor based problem - Anna university solved problem
Methods of improving string efficiency
Переглядів 1264 місяці тому
Methods of improving string efficiency
Nominal T method based problem - Anna university solved problem
Переглядів 3564 місяці тому
Nominal T method based problem - Anna university solved problem
Medium transmission line based problem- Anna University solved problem
Переглядів 2274 місяці тому
Medium transmission line based problem- Anna University solved problem
Bundle conductor based capacitance calculation problems
Переглядів 1254 місяці тому
Bundle conductor based capacitance calculation problems
Determine the capacitance of a 3 phase line operating at 50Hz and the conductors . Prob 1
Переглядів 1234 місяці тому
Determine the capacitance of a 3 phase line operating at 50Hz and the conductors . Prob 1