Randel Baldove
Приєднався 4 лис 2018
i°dea(C°/F)Videos tm*
HOW TO CHECK RUNNING CAPACITOR IF GOOD OR DAMAGE
HOW TO CHECK RUNNING CAPACITOR IF GOOD OR DAMAGE
Переглядів: 47
Відео
SIDE DISCHARGE V8 START UP AND COMMISSIONING
Переглядів 10814 годин тому
SIDE DISCHARGE V8 START UP AND COMMISSIONING
HOW TO REPLACE COMPRESSOR &INVERTER PCB OF V8 VRF SYSTEM
Переглядів 21514 днів тому
HOW TO REPLACE COMPRESSOR &INVERTER PCB OF V8 VRF SYSTEM
1 Hd/E1 ERROR BUSHER ALARM OUTDOOR UNIT NOT WORKING..
Переглядів 12414 днів тому
1 Hd/E1 ERROR BUSHER ALARM OUTDOOR UNIT NOT WORKING..
WRONG WIRING CONNECTION CAN CAUSED PCB DAMAGE.
Переглядів 143Місяць тому
WRONG WIRING CONNECTION CAN CAUSED PCB DAMAGE.
REPLACEMENT OF CONTACTOR RUUD 30TONS RTU.
Переглядів 39Місяць тому
REPLACEMENT OF CONTACTOR RUUD 30TONS RTU.
INSTALLER SAID,INDOOR EVAPORATOR PIPE IS BLOCKED
Переглядів 59Місяць тому
INSTALLER SAID,INDOOR EVAPORATOR PIPE IS BLOCKED
3TONS TOP DISCHARGE COMPRESSOR REPLACEMENT.
Переглядів 128Місяць тому
3TONS TOP DISCHARGE COMPRESSOR REPLACEMENT.
MINI VRF OUTDOOR FAN MOTOR NOT WORKING( Eb ERROR. )
Переглядів 2,3 тис.Місяць тому
MINI VRF OUTDOOR FAN MOTOR NOT WORKING( Eb ERROR. )
ATOM MINI VRF OUTDOOR E9 ERROR CODE ..
Переглядів 2392 місяці тому
ATOM MINI VRF OUTDOOR E9 ERROR CODE ..
RUUD CONCEALED 5TONS COMPRESSOR STUCK UP..
Переглядів 2362 місяці тому
RUUD CONCEALED 5TONS COMPRESSOR STUCK UP..
MINI VRF OUTDOOR NOT WORKING(P1 PROTECTION CODE)
Переглядів 5522 місяці тому
MINI VRF OUTDOOR NOT WORKING(P1 PROTECTION CODE)
P4 PROTECTION CODE ROOFTOP UNIT 30TONS.
Переглядів 1422 місяці тому
P4 PROTECTION CODE ROOFTOP UNIT 30TONS.
INDOOR UNIT E6 ERROR , OUTDOOR UNIT H7 HOW WE FINED THE PROBLEM.
Переглядів 2193 місяці тому
INDOOR UNIT E6 ERROR , OUTDOOR UNIT H7 HOW WE FINED THE PROBLEM.
New installed mini vrf not working(E2/P2 Error)
Переглядів 5863 місяці тому
New installed mini vrf not working(E2/P2 Error)
PC 02 PROTECTION CODE INVERTER WINDOW TYPE MIDEA.
Переглядів 2313 місяці тому
PC 02 PROTECTION CODE INVERTER WINDOW TYPE MIDEA.
E9 ERROR CODE NON INVERTER 3TONS MIDEA SPLIT UNIT.
Переглядів 4283 місяці тому
E9 ERROR CODE NON INVERTER 3TONS MIDEA SPLIT UNIT.
HOW TO INCREASE CFM FOR 25TONS RTU MIDEA(PULLEY ADJUSTMENT)
Переглядів 604 місяці тому
HOW TO INCREASE CFM FOR 25TONS RTU MIDEA(PULLEY ADJUSTMENT)
How to clearing ODU addressing/no. of idu
@@PraveenKumar-wt2vp menu sitting N441 then after it's showing add.clr wait until it's finish you start again address sitting.
No 1
I am also working in midea Qatar
🎉
Takecare always ❤❤❤
Really nothing special
Can you explain properly
Hello
Hi - i dont have C9 it jumps to C2(lower 4) - control unit number KJR-90W/BK - i cannot find hte manual can you share it
@@KillerN3CR0 for KJR-90W/BK some function is not available, WDC-86E/KD And WDC-86E/D have static pressure sitting. Thanks
Sir trane error E9 same LNG DN b s midea?slmt
@@tony-of7pi upo sir same lng po communication error.
@@randelbaldove8996 thank you sir
Good job 👍🏻
Thanks 😁
How did you reset the H4 error?
turn off your power supply for 5 mins and power on again and wait for compressor running and check the voltage if dropping,,its low voltage protection.
@@randelbaldove8996 Thanks it worked.
Hello I have H4 error Code on Midea Heat Pump how to delete it
H4 is appeared when L0/ L1 triggering 3 times L1 means low voltage first check your Voltage is dropping when the compressor is running if in stable Voltage,manually turning off you circuit breaker and wait 5mins power on again.thanks
@@randelbaldove8996 I did exactly that just pull the fuses and wait now it works thanks!
👍🏻
Fake 🤬🤬🤬🤬🤬🤬🤬🤬
give me a reason.why its fake i will teach you how.
Nice job po sir 👏 👏 👏
It’s a good machine ? I will buy same midea spilt unit central plz answer me
Its good machine but this model is out stock,you can choose another model.
@@randelbaldove8996 we have same this model , I’m from Kuwait, I want your advice for it and thank you very much 🌹
@@randelbaldove8996 can you tell number of new model or I buy the old model?
I need you
Where are you in wich country.. Please respons
@@eaem01 im in KSA..
Nice work sir
@@MohammadLuqmaan-z6q thanks bro..
Bir saat cihaza ulaşmanın bekliyoruz
Hi boos how are you
Im fine how are you too..
Thank you so much it worked 👍
Thermal paste Or thermal silicone Is there a specific type? Is it when we put silicone Wait until it dries completely?
@@shehabshams007 after applying no need to dry it,,you can install immediately, thermal silicone &thermal paste its the same use.
@@randelbaldove8996 Is the malfunction code PC02 Is the repair method always the same? Or the problem may be in another part
Sem model hai sir 30 mint chal raha hai fir band ho jaa raha hai
Check error code..
How I can conntact you @@randelbaldove8996
Sem sem makina 30 mint good work offf outdoor
Work good
Good warka
how to set pressure on Midea vrf VC pro
@@franckdanielbandolo894 menu sitting n41 to n48 you can select what you want for pressure..
good evening I subscribe to your page and I really like what you do and I wanted to know I have a Midea VCpro installation which has 12 Units how to adjust the swish
Thanks for watching..If one outdoor unit only you set ENC3 for how many indoors qauntity connected.. for example you have 12 indoors you select C means 12.
Me muestra error U41
You can go to menu sitting, check dry contact function nc(1)02
Disculpa yo no paso del STP1, como le hace para que llegue hasta el 4
If there is problem you cannot go until stp7 to finish start up.
Does it actually work?
@@veter_kg yes its work.
Sir baka ma chat kayo SA messenger about sa mga VRF VRV new subciriber Po.
Nice job well done thank you
How I can lock and unlock the touch screen remount controller? I need your help many thanks
Only centralized controller can activate the lock function of this thermostat model.
Thanks cooling is not good melting things in freezer door in saudia
Check your compressor if working
Yes you have only fixed and now we are maintenance in same place NMDC have more problems due to have your team wrong work, almost have the same thermostats having miss wiring now maintenance team suffering so these are your team works
Call service center for service.
Sir pano po kita makontak? may icoconcern lang po ako. Thanks
Ok lng sir,kahit dto po kayo magmessage.
@@randelbaldove8996 May iiinstall kasi ako AHU-50tr connected to 3 ACCU vc pro. meron po ba kau maireccommend na installer
Doesetnt vork 4 me
If not responding removed the power cable and plug in again to make reseting again.
Sir pwede Po ba mag by pass sa mga VRF York na high pressure switch at panu po?
Pwedi po sir pag na check nyo yung parameters reading normal yung pressure pwedi nyo muna lagyan ng jumper for emergency, dapat palitan nyo rin ng bagong h/p for safety.
@@randelbaldove8996 panu maglagay ng jumper sa gantong nakasalpak sa mismong main board na high-pressure switch?
مانغع
"(LIQUID LINE FROSTING)" Usually means low refrigerant... Where's the leak?
Yes sir you are 90%right almost same case lack of refrigerant,but we find the problem is clogging the orefice cause of high ampere and compressor stop..thanks
@@randelbaldove8996 Yes, I made the comment before watching the vide just based upon the title which is why I put the word "usually" first and yes not only high current but also the high side pressure should have been going through the roof and shut down the compressor if it has a high pressure cutoff switch. That still leaves two questions... Where did the particulates come from to clog the fixed orifice? Maybe compressor or flakes from the inside of the tubes? Second question: Why didn't they make it with a filter dryer? I didn't see if you installed one post orifice replacement. Thanks.
My video not completely because of my cellphone is dead thats why viewer not see we replace the orifice...thanks
Conciled ac f0 what problem
For kjr120c1/b model of thermostat, FO is communication error between thermostat & indoor pcb
Media thermostate display Ed error show how to fix it
Ed means Outdoor detect the system have malfunction, Check the Outdoor display first what error he show thanks.
Nunca se deve usar agua cn javon para revisar fugas en AC de ningun tipo...especialmente en linia de succion xqe succionara el agua enjavonada y tendera humedad dentro del systema...Injenuo...pareses nuevo!!!!
You need to off the ac if you use soap for leaktest
The solution is the scope of the indoor unit board?
If not working please try to Replace first indoor pcb.
Take care always ❤❤❤
Ayos to much learning while watching😊
Salamat sir.
Can you please speak english
Ok sir i try,caused my English is not good.