APT Power Technology serves the electrical power industry with innovative testing and diagnostic solutions. APT products are used to assess the condition of primary assets, and to test protection and measurement equipment.
APT Power Technology is a Chinese Manufacturer, Exporter & Leading Supplier of Electrical test equipment,Measure instrument,Resonance test system,Resonance test series,Vacuum interrupter tester,Induced over-voltage withstand test,DVDF test set,Primary Current Injection,primary injection testing,Hi Pot Test,hipot tester,TTR test and Transformer turn ratio.
APT Power Technology is a Chinese Manufacturer, Exporter & Leading Supplier of Electrical test equipment,Measure instrument,Resonance test system,Resonance test series,Vacuum interrupter tester,Induced over-voltage withstand test,DVDF test set,Primary Current Injection,primary injection testing,Hi Pot Test,hipot tester,TTR test and Transformer turn ratio.
12KV Capacitance & Dissipation Factor Test Set
Dissipation Factor Test Set,Power factor/Tan Delta instrument www.xaapt.com/Products/DIELECTRIC-LOSS-MEASURING-EQUIPMENT/12KV-Capacitance-&-Dissipation-Factor-Test-Set-DF902A?id=19
Переглядів: 3 444
Відео
50KV Fully Automatic AC Hipot Test Set
Переглядів 9124 роки тому
Hipot test sets,Dielectric Withstand Test sets,AC/DC Hipot test sets www.xaapt.com/Products/AC_DC-Hipot-Test-Sets/50KV-Fully-Automatic-AC-Hipot-Test-Set?id=29
Model SI313 Three Phase Relay Tester
Переглядів 1014 роки тому
relay testing kit, relay test set,protective relay tester,protection relay tester www.xaapt.com/Products/Relay-Test-Set/3X40A_4X300V-Three-Phase-Relay-Tester-SI313?id=41
MODEL SI313 THREE PHASE RELAY TESTER
Переглядів 1174 роки тому
Outputs 3 x40Acurrents and 4X300 V independently. Designed for three phase relay test.
Introduction of 80kV VLF high voltage testing equipment
Переглядів 1,2 тис.7 років тому
80kV VLF HV test set/80kV very low frequency high voltage testing equipment -VLF80kV/0.5μF is the best for bigger capacitance specimen testing, such as 35kV XLPE power cable testing, generator testing, power capacitor testing.The load capacity of 80kV VLF high voltage testing equipment is 0.1Hz/0.5μF,0.5Hz/1μF,0.02Hz/2.5μF. We also provide 30kV/40kV/50kV/80kV/90kV/120kV series portable testing ...
How 80kV VLF HV testing equipment to test power cable
Переглядів 15 тис.7 років тому
very low frequency cable testing equipment, VLF testing system www.xaapt.com/Products/VLF/80KV-VLF-Test-Set-VLF80?id=40
90kV VLF High-voltage testing with APT VLF90kV/0.5μF
Переглядів 4757 років тому
APT VLF90kV/0.5μF is an idea substitute of those bigger capacitance specimens, such as 35KV XLPE power cable, Generators, Power Capacitors, their HV dielectric strength test at main power frequency. it need much small test power capacity, about 1/500 in theory and its size & weight also is decreased greatly.We provide 30kV/40kV/50kV/80kV/90kV/120kV series portable test set. More details of test...
AR function(Auto-reclosing) in APT SI616B1 Six-phase Protection Relay Tester
Переглядів 2427 років тому
relay testing kit, relay test set,protective relay tester,protection relay tester www.xaapt.com/Products/Relay-Test-Set/6X30A_6X300V-Relay-Tester-SI616B1?id=23
how to test a distance relay in APT SI616B1 Six-phase Protection Relay Tester
Переглядів 2527 років тому
Testing of distance protection relays is one of the key requirements to ensure their correct operation under short circuit faults during abnormal system conditions. Since protection technology is becoming more and more complex, with protective relays evolving to multifunctional devices with integrated pre-programmed control logic and additional functions like metering, fault and disturbance rec...
Inverse-Time Overcurrent Relay with APT SI616B1 Six-phase Protection Relay Tester
Переглядів 4247 років тому
More details of tester: www.xaapt.com/Products/Relay-Test-Set/6X30A_6X300V-Relay-Tester-SI616B1?id=23 Overcurrent Inverse Protection is the simplest of the ways to protect a line and it owes its application from the fact that in the event of fault the current would increase to a value several times greater than maximum load current. APT SI616B1 Six-phase Protection Relay Tester also could be us...
zero sequence test x264 001
Переглядів 7277 років тому
Zero sequence relay in APT SI616B1 Six-phase Protection Relay Tester Now, we are going to introduce how to use Any test mode to do the zero sequence relay, enter into the Any interface, choose shot then set prefault, max fault and postfault. If the zero sequence of the protective device has direction, we need to set prefault. Because the zero sequence of our protective device has direction, so ...
Differential Relay Protection in APT SI616B1 Six-phase Protection Relay Tester
Переглядів 8637 років тому
As we know, differential relay is one of the most important functions of the 616B1 relay tester. Now, we are going to introduce how to do differential relay with our tester. First, let’s look at the current terminals. As we know, our tester has six phase current. Differential relay can be done by only three phase current, but it requires the operator be familiar with his protective device and k...
TTR test - transformer turns ratio test by APT TTR773
Переглядів 2,5 тис.8 років тому
TTR test confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. APT TTR773 Transformer Turns Ratio Tester are designed to measure the turns ratio of power, instrument, and distribution transfor...
TTR test by APT TTR771F Transformer Turns Ratio Tester
Переглядів 2668 років тому
Transformer Turns Ratio Tester, Transformer turms ratio meter,TTR tester www.xaapt.com/Products/Transformer-Test-Sets/Transformer-Turns-Ratio-Test-Set TTR771F?id=42
Transformer winding resistance tester
Переглядів 1,2 тис.8 років тому
Transformer winding resistance tester
how to test Capacitance | Dissipation | Tan delta factor
Переглядів 2,3 тис.8 років тому
how to test Capacitance | Dissipation | Tan delta factor
How to test transformer winding resistance by APT TO712C transformer Ohmmeter
Переглядів 5 тис.8 років тому
How to test transformer winding resistance by APT TO712C transformer Ohmmeter
Easy way to do wire resistance measurement
Переглядів 1248 років тому
Easy way to do wire resistance measurement
is it available to India?
How is Shunt Reactor transformer testing working ten delta
Designed for transformers or PTs turns ratio test. Exported to many countries.
80KV VLF is designed for Very Low Frequency Test of 35KV and below power cable with extruded insulation.
SI616B1 could output 6 phase currents independently, each up to 40A, is ideal relay tester for transformer Differential Protection
Outputs 3 x40Acurrents and 4X300 V independently. Designed for three phase relay test.
Designed for 50KV AC Dielectric test. Fully automatic, and can be controlled by external computer.
👍
nyc
Hello ! Can you make us a quotation? gmeatrafos@gmail.com Tanks
Congratulations!!
Awesome video.Thanks everyone :) really helpful
Awesome?
Voltage up to 80kV
Hi there. why not direct current device for insulation resistance testing?
Hi Jackson,Direct current device may damage the cable since the output is DC; but vlf is AC output and will not have any damage.
Good vid
Thank you very much for your great comments. APT Power Technology videos are normally associated with products, and this video is referring www.xaapt.com/2014/1026/280.html