Reletrica
Приєднався 7 лют 2016
Como comunicar em Modbus RTU - N4D3E16 e TM200ce24r CLP Schneider - IHM GXU3512
Vídeo dinâmico de comunicação modbus RTU entre placa genérica N4D3E16 e CLP Schneider.
Переглядів: 1 783
Відео
Modbus TCP/IP - Temporizador - Magelis HMIGXU3512 Schneider e LOGO! Siemens.
Переглядів 8362 роки тому
Calibração analógica Machine Expert - Basic TM200 SCHNEIDER.
Переглядів 3753 роки тому
Essa calibração permite definir um valor mínimo e um máximo de variação para a referência analógica do CLP.
LOGO! Siemens - Temporizador via Display
Переглядів 3053 роки тому
Programando temporizador via display LOGO! Siemens.
Temporizador - IHM e CLP Schneider - Vijeo Designer e EcoStruxure Machine Expert Basic.
Переглядів 1,2 тис.3 роки тому
HMIGXU3512 e TM200CE24R
Schneider HMIGXU3512x Vijeo Designer e LOGO Siemens - Comunicação ModBus TCP/IP
Переглядів 6 тис.4 роки тому
LOGO Siemens e IHM Schneider GXU3512x Vijeo Designer - Comunicação ModBus TCP/IP
RTC - Machine Expert Basic & Vijeo Designer Basic - acionando saída através do relógio interno.
Переглядів 6554 роки тому
RTC - Machine Expert Basic & Vijeo Designer Basic.
Thankyou sir You save my time God bless you 🙏
Bonjour Comment convert fichier vda to file system c'est à dire de fichier vda vers fichier vdz (vigeo disigner) Merci
Hello friend, could you record a video on how to connect this module with the Siemens Logo controller or how to set the Modbus address for the Siemens Logo controller?
Boa tarde Ja fez com o plc da china FX3U ? Estou tentando, não estou conseguindo
bom dia peofessor ! otimo video gostei muito, poderia fazer um video acionando as saidas da placa N4D3E16 ? obrigado
Hi, I would like to ask you a simple info. Do you know if is possible to use both inputs and outputs at the same time? From what I've read it just says the you can't command the outputs from the inputs, but it's not clear if through Modbus is possible to use both inputs and outputs. Also, there aren't video showing them working simultaneously. Thanks
yes it is possible to trigger both inputs and outputs
@@reletrica5075 thanks for the clarification mate 👍
Please share your document :D
look in the video description -> ua-cam.com/video/1UGyitrOI0s/v-deo.html
could you share the N4D3E16 word file (the RS485 command), please?
Hi, could you be more specific?
@@reletrica5075 the word file at 00:49. i have no idea how to receive the input status and how to trigger the output status by RS485. Because i can not search the word file on google, i do not know the N4D3E16 register address.
@@張昕哲-k1s Hello, the slave's first word is destined for word 129, which corresponds to input 1, and goes from 129 to 144, each one corresponding to an input. regarding the output, the word is 112, and each bis of this word corresponds to an output on the slave.
@@reletrica5075 thanks for your help. I solved the input ststus scan and success to triger output ^ ^
Bom dia, você teria contato estava precisando de uma ajuda e alguma informação em relação esse software de ihm grato
Obrigado pelo compartilhamento do conhecimento, comecei recentemente a estudar programação e através do seu vídeo economizei muito tempo .