Growatt Inverter Troubleshooting Guide
Growatt Inverter Troubleshooting Guide
  • 14
  • 176 506
Growatt Inverter Warning Code 401 Troubleshooting Guide
Troubleshooting guide for Warning code 401:
1.Check the communication cable connection:
For Min 2.5-6K TL-X inverter, syscom pin 7 to meter Pin 10 RS485A, syscom pin 8 to meter pin 9 RS485B
For Min 7-10K TL-X inverter, syscom pin 7 to meter pin 9 RS485B, syscom pin 8 to meter pin 10 RS485A
For Min 2.5-6K TL-XH inverter, syscom pin 5 to meter pin 10 RS485A, syscom pin 6 to meter pin 9 RS485B
For Mod three-phase inverter with SDM630 three phase meter, syscom pin7 to RS485A, syscom pin 8 to RS485B
2. Check the inverter's setting for export limitation:
Gesture: single tap to choose, double tap to confirm, triple tap to go back.
Set parameter -- advanced -- password 123 -- export limit on -- choose meter -- choose SW -- set export limit ratio
3. Check the CT's position and direction:
Position: put it before all the loads, for example, put it before the main circuit breaker of the house or put it before the electricity meter.
Direction: the arrow towards the load, the letter L is facing the load.
4. Check the syscom connection and meter settings:
Please connects the plug to syscom port, not DRM port
Переглядів: 4 852

Відео

Growatt wifi monitoring app configuration
Переглядів 9 тис.7 місяців тому
Growatt wifi monitoring app configuration
Growatt SPH EPS Port Cover Installation Tutorial
Переглядів 3169 місяців тому
Growatt SPH EPS Port Cover Installation Tutorial
Growatt wifi dongle configuration tutorial
Переглядів 38 тис.Рік тому
Tutorial video for Growatt dongle Shinewifi-X and Shinewifi-S
ARK 2.5H-A1 Batteries Troubleshooting guide
Переглядів 2,3 тис.Рік тому
ARK 2.5H-A1 Batteries Troubleshooting guide If the batteries cannot turn on after you have checked the wiring and the settings. Please measure the voltage for each battery as shown in the video. The normal voltage range for each battery is around 50-53V, if the voltage drops below 48V, the battery might be running out of power and cannot be charged via the inverter. In that case, please contact...
Growatt SYN-50-XH box upgrade instructions
Переглядів 1,9 тис.Рік тому
This video only applies to old SYN-50-XH boxes, the newly manufactured boxes do not require an upgrade. The easiest way to distinguish the old/new model is by looking at the manual or instructions in the box. If there is no manual or instructions in the SYN box, then the box needs to be upgraded. Otherwise, the upgrade is unnecessary. Please contact your installer or Growatt technical support t...
Growatt XH/XA series inverters setup tutorial in the AC Coupled system
Переглядів 6 тис.2 роки тому
Growatt XH/XA series inverters setup tutorial in the AC Coupled system. For single phase property, we recommend installing 1 Eastron SDM630 CT meter, for the specific wiring diagram, please contact the Growatt team for details. For three phase property, we recommend installing 1 Eastron SDM630 CT meter to monitor only one phase given the consideration of the complexity of installing 2 three-pha...
Growatt inverter PE Abnormal troubleshooting guide
Переглядів 29 тис.2 роки тому
Growatt inverter PE Abnormal troubleshooting guide
Growatt Back up box setup tutorial
Переглядів 4,8 тис.2 роки тому
Growatt Back up box setup tutorial
Growatt Min-series inverters export limit setup tutorial
Переглядів 28 тис.2 роки тому
Growatt Min-series inverters export limit setup tutorial
Growatt Min-series inverters power sensor setup tutorial
Переглядів 3,7 тис.2 роки тому
Growatt Min-series inverters power sensor setup tutorial
Growatt SPH series inverter region setup tutorial
Переглядів 10 тис.2 роки тому
Growatt SPH series inverter region setup tutorial
Growatt MIN-series and MOD-series inverter region setup tutorial
Переглядів 35 тис.2 роки тому
Growatt MIN and MOD-series inverter region setup tutorial

КОМЕНТАРІ

  • @simonhutchinson8236
    @simonhutchinson8236 29 днів тому

    Followed the steps, have the flashing blue light yet still can't see the device on the app so no idea of what energy its producing. Any tips on how to see the device on the app?

  • @sampsontendaimutsago1935
    @sampsontendaimutsago1935 Місяць тому

    Sorry for asking kindergarten type of questions but is this the type of setup where one of the machines( hybrid) is used as a reference for the grid tie ( to wake up the grid tie by providing a reference for frequency and voltage)

  • @worldoffun2163
    @worldoffun2163 Місяць тому

    Please contact

  • @worldoffun2163
    @worldoffun2163 Місяць тому

    Please help

  • @worldoffun2163
    @worldoffun2163 Місяць тому

    I want help

  • @worldoffun2163
    @worldoffun2163 Місяць тому

    Bro

  • @worldoffun2163
    @worldoffun2163 Місяць тому

    Helo

  • @aymannoaimee
    @aymannoaimee Місяць тому

    Why I can not change max ac charge curent with shinephone apk ? It gives me parameter type null

  • @shaazy
    @shaazy 2 місяці тому

    What does Power Sensor do exactly?

  • @hamzahansari6900
    @hamzahansari6900 2 місяці тому

    So at 0% it will not export any energy right even if there is no ct? Means can i set it at 0% without connecting the ct?

  • @rightlight.communications1399
    @rightlight.communications1399 2 місяці тому

    Thanks sir

  • @saeedyeganeh1451
    @saeedyeganeh1451 2 місяці тому

    Please go to 5:53 in video Click on advanced. Then it ask for a password. Do you know what is it?

  • @saeedyeganeh1451
    @saeedyeganeh1451 2 місяці тому

    Do you know what is password for unlock advance setup of dongle?

  • @tahirakram9852
    @tahirakram9852 2 місяці тому

    If export set to zero and there no power supply on day time, in that case will it generate power or it will shutdown?

  • @ajaybnl
    @ajaybnl 2 місяці тому

    What is the role of battery input in Growatt 5Kw Min inverter (on grid)

  • @larsiversen7297
    @larsiversen7297 2 місяці тому

    Where do I buy the eps plug?

  • @jastoor007
    @jastoor007 3 місяці тому

    Thank you it works, Growatt inverter error 111 clear by using above technique

  • @energiasolarperu3292
    @energiasolarperu3292 3 місяці тому

    Alguien ya soluciono su problema del PE abnormal ??? que se hace si hay más de 30V ??? indicar los pasos. saludos

  • @maxbiagi3091
    @maxbiagi3091 4 місяці тому

    Guys, i already try 2 days, with so much YT videos but unfoturnetly, even i Connect to dongle hotspot, the Growatt app never set it. Just sill report some problem

  • @hermanmacedo2540
    @hermanmacedo2540 4 місяці тому

    Hello hi need hour hello l

  • @Deepurajgorakhpurno.1
    @Deepurajgorakhpurno.1 4 місяці тому

    Bhaiya mere me pvv Jo dikha raha hai 10w se Jayda nahi ho raha hai kya kare please solve sir

  • @ShubhamGupta-qo7ly
    @ShubhamGupta-qo7ly 4 місяці тому

    I have shinex.... it stuck on connecting to server even routet internet speed is 200mbps

  • @shanedrew6029
    @shanedrew6029 4 місяці тому

    omg, I can't even scan the code to configure to get started for some reason

  • @sjhshah1542
    @sjhshah1542 4 місяці тому

    My new growatt inverter 15kw showed an error message 409 at the time of installation and then could not operate. What should I do?

  • @chevaliercognac8757
    @chevaliercognac8757 5 місяців тому

    You are my saviour! Many thanks!

  • @davronjonmuhammadjonov5624
    @davronjonmuhammadjonov5624 5 місяців тому

    plz help me i installed 5000w grid inverter it is showing error 303 saying PE Abnormal. what to do can i contact you

  • @tahayt6142
    @tahayt6142 5 місяців тому

    Dose this inverter have islanding feature meaning direct AC from solar without connecting to grid or batteries?

  • @daskatubewell
    @daskatubewell 5 місяців тому

    How we can set region for pakistan ?

  • @nobody-xt3zg
    @nobody-xt3zg 6 місяців тому

    Hi. How i update XH inverter in EU region?? There is no videos or support in nordic country and app in end-user mode cant check&update the update. Still update is available to xh model.

  • @hardyrooms
    @hardyrooms 6 місяців тому

    Hi there, i can’t login back to my account? And try to forgot password waiting for email, didn’t come through. And try to make new account, waiting for verification code didn’t come through as well. Why is so hard?

  • @nicu_danciu
    @nicu_danciu 7 місяців тому

    All-in-all os a good presentation, but you are misleading so much by having a home wifi called "inv". Nobody will understand a thing.

  • @usuariouser224
    @usuariouser224 7 місяців тому

    2v and 1.9 v N Ground

  • @anantjariwala6792
    @anantjariwala6792 7 місяців тому

    What to do if there is no light on the dongle?

  • @sweetjuns120
    @sweetjuns120 7 місяців тому

    Where is region A B and C?

    • @growattaustralia1112
      @growattaustralia1112 7 місяців тому

      Please follow the video to set up the region, if the region ABC manual does not come up, please connect your inverter to the internet and contact Growatt technical support to upgrade the firmware, thanks.

    • @waywood
      @waywood 5 місяців тому

      I think they are asking what locations do the A/B/C regions refer to

  • @caspillorogeliojrvaldez570
    @caspillorogeliojrvaldez570 7 місяців тому

    Very nice your lecture I'm pilipino subscribe for you sir

  • @J0nesy17
    @J0nesy17 7 місяців тому

    Any advice what to do if you can't add the datalogger? I'm stuck on step 1. I can scan the datalogger, it tells me it has been added but won't move to step 2. Keep trying, same result. Can't find the datalogger in the list either.

    • @growattaustralia1112
      @growattaustralia1112 7 місяців тому

      Hi Jonesy, if you have configured the datalogger before, the message datalogger has been added may pops up, simply login your shine phone account, choose plant and from the top right, click +, from the dropdown list, find datalogger list, you will find your datalogger there, thank.

  • @johnnysnell43
    @johnnysnell43 8 місяців тому

    Is it possible to bypass the dongle and connect with usb to a computer

    • @growattaustralia1112
      @growattaustralia1112 7 місяців тому

      Hi Johnnysnell, currently it only supports datalogger for the online monitoring, thanks.

  • @allanazotesjr5972
    @allanazotesjr5972 8 місяців тому

    Hi, what is the other way if the ct of spm is not fit to the main feeder?, I need to enable the export control

    • @growattaustralia1112
      @growattaustralia1112 7 місяців тому

      For CT/meter instructions, please refer to the video in the links below ua-cam.com/video/ttSbxeWGRNk/v-deo.html

  • @Swenser
    @Swenser 9 місяців тому

    What happens people when you leave earth connection off and try and run inverter? Does error stay?

    • @growattaustralia1112
      @growattaustralia1112 9 місяців тому

      Hi, earth is required to connect to the inverter's ac plug, please refer to the inverter's manual and AU/NZS Standards.

  • @mikeChisina
    @mikeChisina 9 місяців тому

    We want to con figure: 1. Private IP address on each inverter and connect each also using rj45 cable to the local area network 2. public Port number range inorder to configure Port forwarding on the edge router to remote manage and monitor the inverters. Your assistance is greatly appreciated Mike

  • @ch0asnature
    @ch0asnature 9 місяців тому

    i have this idea, which is to connect a load of equivalent value outputed by the voltage between the neutral and ground :)..will try it and let you kow.

  • @nawazishkhan9271
    @nawazishkhan9271 10 місяців тому

    Good idea👍

  •  11 місяців тому

    Hi, do you know if a three phase inverter (MOD 3000 TL3-XH) is capable to push all it's capacity to one phase only if there is a high load on one phase, but no load on the other two phases?

    • @growattaustralia1112
      @growattaustralia1112 9 місяців тому

      hi, our mod-series inverters are three-phase output, the inverter will optimise the output based on the load consumption. However, it is still three-phase output.

  •  11 місяців тому

    Do you know if a three phase inverter can do zero export and load balancing? For example to push all it's capacity to one phase if needed?!

  • @tolbaysal
    @tolbaysal 11 місяців тому

    Hello, i am using growatt mod 5000tl3-x and eastron smart meter for measuring all consuming, i can see all info from my shinephone app for day time, but i couldn’t see infos after sunset till the sunrise, growatt says inverter sleep after sunset and you cant see the infos. Have you got an idea to see all day infos from shinephone app

  • @DiegoOrge
    @DiegoOrge 11 місяців тому

    Alô para os Brasileiros, entendendo o vídeo, 1 toque no painel altera as opções, 2 toques altera a função, 3 toques grava e sai da função, no caso do erro Warning 111 da Growatt, vc deve ir dando 1 toque até chegar na opção ExportLimit: ON e dar 2 a 3 toques até alterar para ExportLimit: OFF.

  • @BigidyBooh
    @BigidyBooh Рік тому

    I have the same inverter but no option for meter, CT Clamp etc

  • @munteanumihai3774
    @munteanumihai3774 Рік тому

    Then backup box set enabled, comunication with smartmeter disappear

  • @johanandersson2329
    @johanandersson2329 Рік тому

    If the voltage is different more than 0.5v how can you fix that? Is there any bms/charger you can fix it whit?

  • @cdsilva7555
    @cdsilva7555 Рік тому

    Hi, does this inverter have the ability to be set to import at certain times in the night and export at other times in the day.

    • @growattaustralia1112
      @growattaustralia1112 7 місяців тому

      Hi cdsilva, the inverter will automatically import/export based on the load consumption and solar generation, you cannot control the times, sorry for the inconvenience.