Electrical Express
Приєднався 23 бер 2015
Channel contains the Practical and Technical knowledge in all aspects (Protection, Testing, Commissioning, Schemes, Theory, Safety and Emergency Plan) in the field of Power Generation, Transmission and Distribution
Let's Learn Together
Let's Learn Together
Circuit Breaker Arc Phenomenon| Method of Arc Extinction| Restriking Voltage in Circuit Breaker
After watching this Video, We'll learn about
What is Arc in Circuit Breaker
Principle of Arc Extinction
Method of Arc Extinction
Restriking Voltage in Circuit Breaker
You can also watch the following Videos:
Circuit Breaker CRM Test - ua-cam.com/video/btVVPfyQflc/v-deo.html
Circuit Breaker Timing Test - ua-cam.com/video/VD3gYf-gV88/v-deo.html
Circuit Breaker Nameplate details - ua-cam.com/video/cUM6kYm0Lzc/v-deo.html
Operating Sequence of Circuit Breaker - ua-cam.com/video/Vw-gOLmvWDk/v-deo.html
Local Breaker Backup Protection - ua-cam.com/video/FCh7VKiIXTc/v-deo.html
What is Arc in Circuit Breaker
Principle of Arc Extinction
Method of Arc Extinction
Restriking Voltage in Circuit Breaker
You can also watch the following Videos:
Circuit Breaker CRM Test - ua-cam.com/video/btVVPfyQflc/v-deo.html
Circuit Breaker Timing Test - ua-cam.com/video/VD3gYf-gV88/v-deo.html
Circuit Breaker Nameplate details - ua-cam.com/video/cUM6kYm0Lzc/v-deo.html
Operating Sequence of Circuit Breaker - ua-cam.com/video/Vw-gOLmvWDk/v-deo.html
Local Breaker Backup Protection - ua-cam.com/video/FCh7VKiIXTc/v-deo.html
Переглядів: 27
Відео
Bus Bar Differential Protection| Busbar Protection| Blind Zone Protection| Dead Zone
Переглядів 1,2 тис.2 місяці тому
After watching this Video, We'll learn about Bus Bar Differential Protection in Power System Zone in Bus Bar Blind Zone/ Dead Zone Protection You can also watch the following videos on Power System Protection: Reverse Zone Protection - ua-cam.com/video/f4wRFFtNkqQ/v-deo.html Power Swing Block - ua-cam.com/video/KnK0SXWEERE/v-deo.html Operating Sequence of Circuit Breaker - ua-cam.com/video/Vw-g...
SFRA Test of Transformer| Transformer SFRA Test| Sweep Frequency Response Analysis Test
Переглядів 1,8 тис.2 місяці тому
After watching this Video, We'll learn about What is SFRA Test Importance of SFRA Test How to perform SFRA Test SFRA test result You can also watch following videos: Transformer Vector Group Test - ua-cam.com/video/sZP3QBI9vGM/v-deo.html Transformer Voltage Ratio Test - ua-cam.com/video/FJKmDfC2kTQ/v-deo.html Transformer No Load Test - ua-cam.com/video/MGClLiTlRgc/v-deo.html Switching Impulse W...
How to Draw Transformer Vector Group| Vector Group connection| Transformer Dy11 Dy1 Dy5 Yd11 Yd1
Переглядів 2,5 тис.4 місяці тому
After watching this video, We'll learn about Transformer Vector Group How to draw Transformer Vector group Dy11, Dy1, Dy5, Yd11, Yd1 You can also watch following videos: Transformer Vector Group Test - ua-cam.com/video/sZP3QBI9vGM/v-deo.html Transformer Voltage Ratio Test - ua-cam.com/video/FJKmDfC2kTQ/v-deo.html Transformer No Load Test - ua-cam.com/video/MGClLiTlRgc/v-deo.html Switching Impul...
Dielectric Frequency Response Analysis| DFR Test| Frequency Domain Spectrum| FDS Test| Transformer
Переглядів 1,3 тис.5 місяців тому
After watching this video, We'll learn about 1. What is DFR or FDS Test of Power Transformer 2. Purpose of DFR Test 3. How to perform DFR Test 4. Result of DFR/ FDS Test You can also watch following videos: Transformer Vector Group Test - ua-cam.com/video/sZP3QBI9vGM/v-deo.html Transformer Voltage Ratio Test - ua-cam.com/video/FJKmDfC2kTQ/v-deo.html Transformer No Load Test - ua-cam.com/video/M...
Transformer Vector Group Test| Vector Group of Transformer| Dy11
Переглядів 4,4 тис.6 місяців тому
After watching this video, We'll learn about What is Vector Group in Power Transformer Different Vector Group Vector Group Test of Transformer You can also watch following videos: Transformer Voltage Ratio Test - ua-cam.com/video/FJKmDfC2kTQ/v-deo.html Transformer No Load Test - ua-cam.com/video/MGClLiTlRgc/v-deo.html Switching Impulse Withstand Test - ua-cam.com/video/Nd7zmRWtWnw/v-deo.html Li...
Transformer Voltage Ratio Test| Turns Ratio Test of Transformer| TRM Test
Переглядів 8 тис.6 місяців тому
After watching this video, We'll learn about What is Voltage Ratio of Transformer What is Voltage Ratio Test IEC standard of Voltage Ratio Test of Power Transformer You can also watch following videos: Transformer No Load Test - ua-cam.com/video/MGClLiTlRgc/v-deo.html Switching Impulse Withstand Test - ua-cam.com/video/Nd7zmRWtWnw/v-deo.html Lightning Impulse Withstand Test - ua-cam.com/video/Q...
What is CT Burden| Current Transformer Burden Calculation
Переглядів 1,8 тис.8 місяців тому
After watching this video, We'll learn about What is CT Burden CT Burden Calculation Importance of CT Burden in Power System You Can also watch following videos: What is ISF and ALF in Current Transformer - ua-cam.com/video/fj6WJV6tNrY/v-deo.html Current Transformer Nameplate Details - ua-cam.com/video/Uu30vqSME0c/v-deo.html Power Transformer Nameplate Details - ua-cam.com/video/zbQIMGjqOpY/v-d...
What is ISF and ALF in Current Transformer| Instrument Security Factor| Accuracy Limit Factor of CT
Переглядів 1,2 тис.8 місяців тому
After watching this video, We'll see about Accuracy Limit Factor ISF CT Core Saturation You can also watch following videos Current Transformer Nameplate Details - ua-cam.com/video/Uu30vqSME0c/v-deo.html Power Transformer Nameplate Details - ua-cam.com/video/zbQIMGjqOpY/v-deo.html Circuit Breaker Nameplate Details - ua-cam.com/video/cUM6kYm0Lzc/v-deo.html Thank you for watching the videos
Current Transformer Nameplate Details| CT Nameplate Details| ISF and ALF of CT
Переглядів 3,1 тис.8 місяців тому
After watching this video, We'll learn about CT nameplate details Insulation Level ISF/ ALF CT Ratio CT Cores Rated Voltage of CT You can also watch Power Transformer Nameplate Details - ua-cam.com/video/zbQIMGjqOpY/v-deo.html Circuit Breaker Nameplate Details - ua-cam.com/video/cUM6kYm0Lzc/v-deo.html Thank you for watching the videos
Full Load Test of Transformer| Short Circuit Test of Transformer| Percentage Impedance Calculation
Переглядів 3,2 тис.9 місяців тому
After watching this video, We'll learn about the Full Load/ Short Circuit Test of Power Transformer Importance of Full Load Test How we perform Full Load Test Calculation of percentage Impedance You can also watch the following Video: Transformer No Load Test - ua-cam.com/video/MGClLiTlRgc/v-deo.html Switching Impulse Withstand Test - ua-cam.com/video/Nd7zmRWtWnw/v-deo.html Lightning Impulse Wi...
No Load Test of Transformer/ Open Circuit Test| No Load Current of Power Transformer
Переглядів 4,4 тис.9 місяців тому
After watching this video, We'll learn about What is No Load Test of Power Transformer Why we perform No Load Test How to perform No Load Test No Load Test Result and Calculation You can also watch the following Video: Switching Impulse Withstand Test - ua-cam.com/video/Nd7zmRWtWnw/v-deo.html Lightning Impulse Withstand Test - ua-cam.com/video/Q0L KJ2sa8/v-deo.html Tans Delta Test Explanation a...
Single Line Diagram Power System| Power System SLD| Substation
Переглядів 2679 місяців тому
After watching this video, We'll learn about the Power flow for Generation to Transmission to Distribution Power System Single Line Diagram Substation and Switchyard Single Line Diagram (SLD) Power Transformer Current Transformer Lightening Arrestor Isolator You can also watch the following videos for Single Line Diagram and Bus Bar arrangement: Substation Single Bus Bar System - ua-cam.com/vid...
Circuit Breaker Contact Resistance Measurement Test| CRM Test of Circuit Breaker
Переглядів 2,4 тис.10 місяців тому
After Watching this Video, We'll Learn about What is CRM Test Why we do CRM test of Circuit Breaker Procedure and Connection of CRM Test Question You can also watch the following Videos: Circuit Breaker Timing Test - ua-cam.com/video/VD3gYf-gV88/v-deo.html Circuit Breaker Nameplate details - ua-cam.com/video/cUM6kYm0Lzc/v-deo.html Operating Sequence of Circuit Breaker - ua-cam.com/video/Vw-gOLm...
Reverse Zone Protection| Distance Protection| Zone4 Protection| Bus Differential Backup Protection
Переглядів 2,1 тис.11 місяців тому
Reverse Zone Protection| Distance Protection| Zone4 Protection| Bus Differential Backup Protection
Transformer AC Voltage Withstand Test| Power Frequency Test| Hi-POT Test of Power Transformer
Переглядів 1,2 тис.11 місяців тому
Transformer AC Voltage Withstand Test| Power Frequency Test| Hi-POT Test of Power Transformer
Under Frequency Load Shedding Scheme| Under Frequency in Power System| Grid Blackout
Переглядів 95411 місяців тому
Under Frequency Load Shedding Scheme| Under Frequency in Power System| Grid Blackout
SF6 Gas Purity Check| Rapidox Kit| Circuit Breaker SF6 Gas Purity Check
Переглядів 708Рік тому
SF6 Gas Purity Check| Rapidox Kit| Circuit Breaker SF6 Gas Purity Check
Switching Impulse Withstand Test of Power Transformer| Impulse Voltage Withstand Test of Transformer
Переглядів 1,8 тис.Рік тому
Switching Impulse Withstand Test of Power Transformer| Impulse Voltage Withstand Test of Transformer
Local Breaker Backup Protection| LBB Protection in Power System| 50Z| Breaker Failure Relay
Переглядів 3,2 тис.Рік тому
Local Breaker Backup Protection| LBB Protection in Power System| 50Z| Breaker Failure Relay
Circuit Breaker Timing Test| Opening Time and Closing time of Circuit Breaker
Переглядів 3,2 тис.Рік тому
Circuit Breaker Timing Test| Opening Time and Closing time of Circuit Breaker
Power Swing Block Protection in Power System| Concept of Power Swing Block in Relays
Переглядів 4,9 тис.Рік тому
Power Swing Block Protection in Power System| Concept of Power Swing Block in Relays
Difference between Electromechanical Relay and Numerical Relay
Переглядів 570Рік тому
Difference between Electromechanical Relay and Numerical Relay
Lightning Impulse Test of Transformer| Impulse Voltage Withstand Test of Transformer| 1/50 Wave test
Переглядів 5 тис.Рік тому
Lightning Impulse Test of Transformer| Impulse Voltage Withstand Test of Transformer| 1/50 Wave test
Transformer Magnetic Balance Test| Magnetic Balance Test of Transformer in Star and Delta connection
Переглядів 3,2 тис.Рік тому
Transformer Magnetic Balance Test| Magnetic Balance Test of Transformer in Star and Delta connection
Transformer Oil Gas generation| Why OTI/ WTI alarm set on 90 deg Cel
Переглядів 1,4 тис.Рік тому
Transformer Oil Gas generation| Why OTI/ WTI alarm set on 90 deg Cel
Tan Delta Test UST and GST Mode| Ungrounded and Grounded Specimen Test| UST & GST mode of Tan Delta
Переглядів 16 тис.Рік тому
Tan Delta Test UST and GST Mode| Ungrounded and Grounded Specimen Test| UST & GST mode of Tan Delta
SOTF Protection| Switch On to Fault| SOTF and ARR
Переглядів 3,5 тис.Рік тому
SOTF Protection| Switch On to Fault| SOTF and ARR
Transformer Winding Resistance Test| Winding Resistance Test of Transformer
Переглядів 15 тис.Рік тому
Transformer Winding Resistance Test| Winding Resistance Test of Transformer
Operating Sequence of Circuit Breaker| Duty Cycle of Circuit Breaker| Auto Reclosing ARR
Переглядів 2,1 тис.Рік тому
Operating Sequence of Circuit Breaker| Duty Cycle of Circuit Breaker| Auto Reclosing ARR
If fault in Q section Z1 towards R as you explained, then how not carrier send to P section relay to trip, what is scheme pls explain sir
No load current can be resolved into two components viz. 1. Component Iw (iron loss component) which supplies iron loss and very small copper loss Iw = Iocos(fy0) 2. Component Im (magnetising component) which produces mutual flux in core Im = Iosin(fy0). Thanks for explanation bhai keep uploading more videos related testing 🙏
🙏
bhai ya to English bol de ya to Hindi bol de chotyon ki tarha samja raha hai
Unused CT core should be short circuited not the terminals. If the other terminals of a used core remain open nothing will happen. Please rectify the concept.
Suppose the breaker stuck in 22kV substation where lbb is not provided then transformer LT associated with that feeder will get trip.
Yes
Nice explanation....
Thank you 😊
SIR CT voltage 5v And the CT Burden is 25va
Amazing explanation. Thank You sir for making such video.❤
Thank you 😊
Kitna value accepted hoga wrm k liye?
It depends on transformer specification and previous values
💯 marks for explanation
Glad you liked it
jab moving part nechy wala hay tho upar connection kion lagana hay
Both moving and Fixed Contact are in upper stack only
Nice explain sir
Keep watching
VAn=VAc+VNc VBb~VBc Vcb>VCc
Sir agar transformer ki winding agar short hai to kya resistance km hoga ya jayada
Voltage across secondary ct is 5v & burden is 25va. Kindly tell me this is right?
खतरनाक bade bhai aapne bahot hi achhe se samghaya aapka bahot bahot आभार....tahe dil se bade मिया 😊😊😊😊
Thanks
Fault hone ke bad trip hote hai
Rccb
Iec or ieee symbol
132/33KV??
Agar FAT test report nhi hai mai site Mai sfra test karke analysis kaise karenge without test report reference
Bro plz guide about Detanking of the transformer and strip down
Excellent bro plz send your email
I'm glad you found the video helpful!
Intresting video bro ❤
Thank you
Pls make video on ABB REF615 Numerical relay all current and voltage setting calculation and meaning of all settings??
Ok 👍
51 relay will not trip , why not trip
VAN=VAc+VcN VAC>VCc VBb~VBc
Thank you
Can you please share your contact number?
Local breaker backup protection (50BF)
Secondry voltage 5 V BURDEN -25 VA
Very good explanation Thanks
Thank you
Thank you for the detailed explanation, brother.
Thank you
Impedance is a constant parameter& free from voltage value and can not varry as per voltage variation
he is talking about the impedance seen by the relay. Relay calculates impedance based on V and I it is getting as input
Z=R+X as X always varies so it means Z can't b constant
Impedance of both side to be same
good sir
Thank you
Good job
Thank you
Very good.
Thank you
Very nice explanation bro
Thank you
Nice explanation
Thank you
Excellent Explanation
Thank you
Voltage- 5 V Burden- 25 VA
Nice
Thank you
Very nice explain sir👍👍
Thank you
Wrong apne jab LV ha HV ka test kiya then HV kiya so LV and ground ko short karna chahiye
For IR test, we can go for different combinations
Very good teaching
LBB protection
👍
1 and half why...you do not know & Knowing
Vaccum ३० Sf६ ६० Air १००