Festo North America
Festo North America
  • 369
  • 2 183 397
Flexible Architecture for IP65 Remote I/O and Valves
Put remote I/O and valves where you need them. Easily add digital I/O, IO-Link, and analog inputs to extend the functionality of your PLC across your machine or conveyor line. The CPX-AP product lines from Festo support up to 80 modules of additional I/O on one fieldbus module. And with CPX-AP-I distributed I/O and valves, you can place modules up to 50 m apart from one another.
Use your preferred PLC with EtherNet/IP, EtherCAT, PROFINET, and Modbus TCP fieldbus networks.
Festo CPX-AP-I for distributed remote I/O and valves, including the new VTUX valve manifolds.
www.festo.com/CPX-AP-I
Festo CPX-AP-A for centralized remote I/O and valves, including the new VTUX valve manifolds.
www.festo.com/CPX-AP-A
Переглядів: 623

Відео

Comment comparer les matériaux - Panier d'achat (FR)
Переглядів 17Місяць тому
Cette vidéo vous guidera à travers le processus de comparaison des matériaux dans le panier. Nous découvrirons les étapes à suivre pour comparer les matériaux: * Cliquez sur la case de sélection à gauche des matériaux à comparer. * Cliquez sur "Comparer". * Vous pouvez filtrer par les similitudes et/ou différences. * Vous pouvez télécharger la comparaison au format CSV. * Supprimez des matériau...
How to Compare Materials - Cart (ES)
Переглядів 18Місяць тому
Este video le mostrará cómo comparar materiales a través de los pasos del carrito de compras: 1. Vaya a su carrito y agregue materiales (si aún no hay materiales). Puede comparar hasta 12 materiales a la vez. 2. Marque la casilla al lado izquierdo del material a comparar, y presione el botón de "Comparar" 3. Filtre para ver las diferencias/similitudes en los atributos del material. 4. Descargue...
How to Compare Materials - Cart (EN)
Переглядів 17Місяць тому
This video will guide you through how to compare material via the shopping cart steps: 1. Go to your cart and add materials (if there are no materials yet). You can compare up to 12 materials at a time. 2. Mark the check mark next to the material to compare, and click the "Compare" button. 3. Filter to see differences/similarities in the material's attributes. 4. Download a .csv file. 5. Clear ...
Transfer 8-byte Datatype Values to and from CMMT drives and Rockwell PLCs
Переглядів 121Місяць тому
This video shows how to set up and utilize the CMMT Extended Process Data AOI for 64-bit data types within a Rockwell Studio5000 project. For the files associated with this video, please download from this public GitHub link: github.com/Festo-North-America/MTE-Videos/blob/71fca2eb8a295b7f3bdbca1fb1fc3f4367339d45/041_CMMT Extended Process Data AOI for 8-byte Datatypes in Studio 5000/99_CurrentFu...
Understanding Festo CPX Classic’s LEDs
Переглядів 1012 місяці тому
This video will discuss the LEDs on the CPX Classic and how to read the different patterns
Festo CDPX Software Overview
Переглядів 1792 місяці тому
This video will show the user Designer Studio and how to create HMI screens. We will also go over how to connect PLC variables to button layouts on the HMI Designer Studio: www.festo.com/us/en/support-portal-specific/?query=8155215&groupId=4&productName=Operator unit&documentId=647934
Festo CDPX Hardware Overview
Переглядів 1982 місяці тому
This video will discuss the hardware features about the Festo CDPX Human Machine Interface (HMI) Festo Documentation: www.festo.com/media/pim/831/D15000100121831.pdf
Setup and Test CMMT-AS Drive in ACS Controller Environment SPiiPlus MMI Application Studio
Переглядів 1452 місяці тому
This video shows how to set up a CMMT drive in the ACS Motion Control PC environment SPiiPlus MMI Application Studio. A simple point-to-point motion is executed. 0:04 - Introduction 0:15 - Adjust and save CTIME=1 in System Setup 0:37 - Add Non ACS EtherCAT Product List file to Controller 1:10 - Add CMMT-AS-MP ESI File 1:22- Automatic setup and controller reboot to load List file 1:40 - Test sim...
SMS Control via Modbus TCP with CPX-AP-I-EP-M12 using Pro-face GP-Pro EX
Переглядів 1983 місяці тому
This video shows how to control and SMS actuator via IO-Link using a CPX-AP-I-EP-M12 module connected via Modbus TCP to a Pro-face PLC/HMI. Software utilized is GP-Pro EX. Application Note - IO-Link Interface description Simplified Motion Series - www.festo.com/us/en/support-portal-specific/?query=8083433;8083424;8083493;8083470;8083398;8083383;8083425;8083471;8083384;8083426&groupId=18&product...
Controlling Festo CMMT with LabVIEW
Переглядів 2643 місяці тому
This video will show the user how to control our Festo CMMT with LabVIEW Festo Automation Suite: www.festo.com/us/en/support-portal-specific/?query=festo automation suite-&groupId=4&productName=festo automation suite-&documentId=648077 LabView CMMT Application: app.box.com/s/a6itu1h7klh3r6ttjqj07ue5kfg8z9ky
It's So Easy to Expand Your Remote I/O System
Переглядів 1193 місяці тому
When you need to add an I/O module to your machine, do it the easy way with the combination of CPX-AP-A and CPX-AP-I remote I/O systems from Festo. Every CPX-AP-A bus interface comes with an expansion port on it, which can be connected to additional remote I/O modules and valve terminals. In this simple example, a six-module CPX-AP-A terminal is expanded with a CPX-AP-I module, increasing the n...
Which Power Connector do You Prefer?
Переглядів 653 місяці тому
The CPX-AP-A family of remote I/O terminals offers several power connection types to choose from: M12 L-coded 5-pin (one or two connections per sub-base), AIDA push/pull, 7/8" 5-pin, and M18 4-pin. All support power zoning and are rated IP65/67 for use outside the control cabinet. Learn more about CPX-AP-A here (click the Product Highlights tab): www.festo.com/us/en/p/automation-system-id_CPX_A...
Take Control of Power Zones in Your Machine
Переглядів 693 місяці тому
Power zones in remote I/O systems allow you to control the power to groups of actuators, for example if you want to power off (disable) one group of actuators in your machine while leaving the rest powered on (enabled), all while maintaining uninterrupted monitoring of inputs, status, and diagnostics in your system. Festo makes this easy by offering the flexible creation of power zones in remot...
It's Never Been Easier to Add Valves to Your Remote I/O System
Переглядів 753 місяці тому
When you need to add a valve manifold to your machine and want to mount the valves close to the pneumatic actuators (#bestpractice), do it the easy way with the combination of CPX-AP-A and CPX-AP-I valve systems from Festo. Every CPX-AP-A bus interface comes with an expansion port on it, which can be connected to a remote valve terminal. In this simple example, a six-module CPX-AP-A terminal is...
I/O Modules for Every Machine
Переглядів 1483 місяці тому
I/O Modules for Every Machine
Place the Bus Interface Where You Want It
Переглядів 803 місяці тому
Place the Bus Interface Where You Want It
The (Beautiful) Marriage of Remote I/O and Pneumatic Valves
Переглядів 793 місяці тому
The (Beautiful) Marriage of Remote I/O and Pneumatic Valves
Gentle and secure transport of wafers
Переглядів 1333 місяці тому
Gentle and secure transport of wafers
Behind the Scenes: The Extensive Testing that Festo Products Endure
Переглядів 3464 місяці тому
Behind the Scenes: The Extensive Testing that Festo Products Endure
Easy Integration of Remote I/O, Valves, and Motion Control
Переглядів 3234 місяці тому
Easy Integration of Remote I/O, Valves, and Motion Control
Innovative Electromechanical Actuators from Festo
Переглядів 1,8 тис.4 місяці тому
Innovative Electromechanical Actuators from Festo
Manually Teach SPAE Sensor Pressure Setpoint
Переглядів 3134 місяці тому
Manually Teach SPAE Sensor Pressure Setpoint
Êtes-vous prêt pour votre audit de certification en matière de sécurité alimentaire ?
Переглядів 194 місяці тому
Êtes-vous prêt pour votre audit de certification en matière de sécurité alimentaire ?
¿Está preparado para su auditoría de certificación de seguridad alimentaria?
Переглядів 234 місяці тому
¿Está preparado para su auditoría de certificación de seguridad alimentaria?
Are you ready for your food safety certification audit?
Переглядів 444 місяці тому
Are you ready for your food safety certification audit?
Économisez de l'énergie grâce à nos 10 meilleurs conseils !
Переглядів 154 місяці тому
Économisez de l'énergie grâce à nos 10 meilleurs conseils !
¡Ahorra energía con nuestros 10 mejores consejos!
Переглядів 554 місяці тому
¡Ahorra energía con nuestros 10 mejores consejos!
Save energy with our top 10 tips!
Переглядів 514 місяці тому
Save energy with our top 10 tips!
Fully automated end-of-line testing of battery packs with Hahn and Festo
Переглядів 2404 місяці тому
Fully automated end-of-line testing of battery packs with Hahn and Festo

КОМЕНТАРІ

  • @Rebold1987
    @Rebold1987 11 днів тому

    How are you online in FAS and TIA at the same time??? 🙂

    • @FestoNorthAmerica
      @FestoNorthAmerica 11 днів тому

      Hi, thanks for reaching out! For any questions you may have, feel free to get in touch with our specialists through this link: www.festo.com/us/en/e/contact-id_59297/ Best regards.

  • @Sabine29_08
    @Sabine29_08 21 день тому

    hello i can ask material use in adaptive finger, thank you.

  • @NancyMartinez-r8j
    @NancyMartinez-r8j 26 днів тому

    Zita Trace

  • @YaelAlcantar
    @YaelAlcantar Місяць тому

    Thanks!! Very useful. Is it possible to create recipes using the HMI itself. For example, having a Create Recipe buttom?

  • @Labbot
    @Labbot 2 місяці тому

    Hi! I'm a student researcher, and I'd love to know what software/method you used to simulate the fin ray grippers for this video.

    • @FestoNorthAmerica
      @FestoNorthAmerica Місяць тому

      Hi, thanks for your comment! We recommend checking out our PDF on this system at the following link: www.festo.com/media/pim/049/D15000100122049.PDF Alternatively, feel free to visit our website for more information. Regards.

  • @DonneDorothy-k5t
    @DonneDorothy-k5t 2 місяці тому

    Anthony Branch

  • @RPSun-yf3gm
    @RPSun-yf3gm 2 місяці тому

    well

  • @EngineerAt_UTAC
    @EngineerAt_UTAC 2 місяці тому

    I downloaded your code and running with a Demo unit borrowed from your local distributor. My setup is using Application class 1 ( Telegram 1). I am able to turn the motor on and start running but i do not have control over velocity and acceleration. The same connection is working well when used from Festo Automation Suite. Any idea what may not be set correctly?

    • @FestoNorthAmerica
      @FestoNorthAmerica 2 місяці тому

      Hello, thank you for your message. You can send a message to our experts through the following link, and they will provide you with specific information about your issue as soon as they receive the request. www.festo.com/us/en/e/technical-support-id_646900/ Regards.

    • @EngineerAt_UTAC
      @EngineerAt_UTAC 2 місяці тому

      @@FestoNorthAmerica Thanks for your response. I changed the setup to broadcast Telegram 111 and your LV Code is working for me.

  • @paulgunter9189
    @paulgunter9189 2 місяці тому

    Hello, im trying to run the edcon-gui but its not working. Maybe you can give some short introduction. Thanks a lot!

    • @FestoNorthAmerica
      @FestoNorthAmerica 2 місяці тому

      Hi Paul, You can contact our specialists directly using the following link. They will guide you in resolving your issue. www.festo.com/us/en/e/technical-support-id_646900/ Regards.

  • @balajivan
    @balajivan 3 місяці тому

    I have upcoming project with this similar application, could someone provide the correct contact information to kickstart. I send an email to canada support team no respond so far.

    • @FestoNorthAmerica
      @FestoNorthAmerica 2 місяці тому

      Hello, thank you for contacting us. Please find the link below for various contact options in Canada: www.festo.com/ca/en/e/contact-id_59297/ Additionally, here is the page where you can find more information about those systems, which might be useful to you: www.festo.com/ca/en/e/solutions/collaborative-engineering/handling-systems-id_4462/ Regards.

  • @JRB-l5u
    @JRB-l5u 3 місяці тому

    You are talking about the máximun flow rate, but what is the flow rate when using the narrower base of 10.5 mm width?

  • @huynhminhang1020
    @huynhminhang1020 4 місяці тому

    Thanks you so musch for your helpful. Can you please share me the file.7z you link to GXwork. Thanks you so much

  • @Philip-4
    @Philip-4 4 місяці тому

    Where did you find the AOI used in this video, I need such for a project

    • @FestoNorthAmerica
      @FestoNorthAmerica 4 місяці тому

      Hi Philip - send an email to marketing.us@festo.com and we can send you the AOI files.

    • @Philip-4
      @Philip-4 4 місяці тому

      @@FestoNorthAmerica Done! Thank you.

  • @DmitriiVasilev-sb4kv
    @DmitriiVasilev-sb4kv 5 місяців тому

    Really great unboxing and clear explanation! Thanks Tom!

  • @MrKevinbat
    @MrKevinbat 5 місяців тому

    I'm having a problem when xf1 isn't recognizing or responding to python. I have the drive set to mudbus tcp, telegram 111 and configured my ethernet port to work with the ip address I have set for the port.

    • @MrKevinbat
      @MrKevinbat 5 місяців тому

      I'm using a cmmt-as-cs-11a-p3-mp-s1

    • @FestoNorthAmerica
      @FestoNorthAmerica 4 місяці тому

      It’s important that you Restart the CMMT drive after setting the XF1 port to Modbus. Once this is done, you should get online with the drive once again with Festo Automation Suite and confirm you are in Modbus TCP mode and that the Active network settings are the desired ones (IP address, Subnet, etc.). You can check this under Fieldbus > EtherNet/IP -Modbus > Active. If the problem persists, we suggest you contact Festo Tech Support in your country so they can further assist troubleshooting.

  • @aleksmalamis3505
    @aleksmalamis3505 8 місяців тому

    PLC screen is very small and it's not possible to see what is there.

  • @tanervatansever1003
    @tanervatansever1003 8 місяців тому

    Hello, why is there an air outlet from outlet 2 and 4 together?

  • @tanervatansever1003
    @tanervatansever1003 8 місяців тому

    Hello, why air comes out of number 2 and 4 at the same time

  • @ucronotopia1988
    @ucronotopia1988 9 місяців тому

    Helpful video!

  • @rodolfobassi4655
    @rodolfobassi4655 11 місяців тому

    Cómo se desarman ?

    • @FestoNorthAmerica
      @FestoNorthAmerica 11 місяців тому

      Hello, thanks for reaching out! For any technical questions, please contact: technical.support.us@festo.com

  • @SunilSK-s9n
    @SunilSK-s9n 11 місяців тому

    Hi... How to configure Festo servo(cmmt-as-c2-3a-pn-s1) profinet with twincat 3. Can u help me please. thank you

    • @FestoNorthAmerica
      @FestoNorthAmerica 11 місяців тому

      Hello, thanks for reaching out! For any technical questions, please contact: technical.support.us@festo.com

  • @marcosaraujo4081
    @marcosaraujo4081 Рік тому

    Amazing, I would like a portuguese PT-BR version

  • @Seagull.Lord127
    @Seagull.Lord127 Рік тому

    Great video! But im totally stuck on my errors... Could you make a video on the different kind of errors such as 1004 - Read_Parameter Error. 1005 - Write_Parameter Error. 1006 - “Position Value” Error. Check If Start Press Position value is Higher than the End Position Value. 1007 - “Position Value” Error. Check If Intermediate Position value is Higher than the End Position Value. 1008 - “PQI” Error. Check the device connection.

  • @chandrasekharsingh3342
    @chandrasekharsingh3342 Рік тому

    😮😮

  • @chandrasekharsingh3342
    @chandrasekharsingh3342 Рік тому

    😅

  • @ColinGreatwood
    @ColinGreatwood Рік тому

    Serves as a complement to the standard VTSA-F setup video with 0 electrical safety zones: ua-cam.com/video/3QFYIXgCJkE/v-deo.html

  • @marciogarcia4761
    @marciogarcia4761 Рік тому

    Amazing product.

  • @IainHendry
    @IainHendry Рік тому

    Can the SMS series now move to an unlimited number of positions? Previously they were limited to two or three positions only, depending on the firmware.

    • @SebastianBalosTechTalk
      @SebastianBalosTechTalk Рік тому

      Initially the SMS series was designed to be a basic and inexpensive way to get into electrical actuators. At this point it is still inexpensive but you can now do unlimited positions via IO Link communication.

  • @AjeetKumar-uz9st
    @AjeetKumar-uz9st Рік тому

    Procedure for removal of PL error in festo cpx-fb13

  • @VadimSSSSSS
    @VadimSSSSSS Рік тому

    First

  • @ardelleklacic8142
    @ardelleklacic8142 Рік тому

    'promosm' 😇

  • @ypkapo2
    @ypkapo2 Рік тому

    What a good video. The explanation is excellent!! Hopefully they can make some similar video in the future for PROFINET or ETHERCAT or MODBUS. Thank you very much and best regards.

  • @syedabdullah8371
    @syedabdullah8371 Рік тому

    Hey there! I just checked out your content and I think you are working really hard! However, I noticed that your thumbnails could use a little love. If you're interested, I offer custom thumbnail design services that will help your videos stand out. Trust me, I've got some fantastic offers that you won't want to miss Let's make your channel really pop and attract more viewers!

  • @aieinarin
    @aieinarin Рік тому

    J,

  • @stefankrombach
    @stefankrombach Рік тому

    Great Video! - Congratulations colleagues

  • @JakeTheSnake509
    @JakeTheSnake509 Рік тому

    WTF, whats the point in having festo automation suit..... ugh

  • @Proud2BProud
    @Proud2BProud Рік тому

    I think its great when companies come together - what a great fit of resources and ideas. The Edson machine looks state of the art and the design looks fantastic. 👍👍

  • @TheJMadarash
    @TheJMadarash Рік тому

    Great podcast guys!!!!!

  • @JoseAntonio-qp4kx
    @JoseAntonio-qp4kx Рік тому

    Hi!! How to disassemble? I wanto to change the joints

  • @Nature_Quixote
    @Nature_Quixote Рік тому

    No link??? Please add a link

  • @raghubatteriesandsolarcons37

    Hello

  • @RickThePeasant
    @RickThePeasant 2 роки тому

    Will DSNU cylinders last a lot longer if lubricated? The cylinders get washed down once a day with hard water.

    • @FestoNorthAmerica
      @FestoNorthAmerica 2 роки тому

      @Rick Cameron - Festo cylinders are lubricated for life. In a washdown environment, the cylinder does not require additional lubrication if the piston rod is not extended during the washing process. If the rod is extended during the washing process, a lubricator could help extend the life of the seals. We also offer a special rod wiper seal, made of UHMW-PE, which has very low friction so it can operate without any lubrication even in a washdown environment. This may be preferable to lubricating since it does not require the regular maintenance of keeping a lubricator full of oil.

    • @RickThePeasant
      @RickThePeasant 2 роки тому

      @@FestoNorthAmerica thanks for the reply. Will the part number for these wipers be in the dsnu catalog?

    • @FestoNorthAmerica
      @FestoNorthAmerica 2 роки тому

      @RIck - The rod wiper seal that is suitable for use in wet and frequent washdown environments is denoted as -R85 for the DSNU cylinder. For DSNU, this is an option that is not documented in the standard product catalog and must be quoted by Festo customer service. We offer this rod seal as standard with our CRDSNU stainless steel cylinder, it is called -A3. CRDSNU is similar to DSNU but offers higher corrosion protection and a cleaner design. Feel free to contact us in North America for support, at technical.support.us@festo.com or +1 (800) 993-3786. Thanks!

  • @raghubatteriesandsolarcons37
    @raghubatteriesandsolarcons37 2 роки тому

    Hi i am a battery consultant need to explore my self to arround the world

  • @luisalfaro8968
    @luisalfaro8968 2 роки тому

    ESTOY QUE INTENTO REGISTRARME PERO NUNCA ME ENVIAN EL CORRE DE FESTO QUE ESTARE HACIENDO MAL?

  • @tommygunn59
    @tommygunn59 2 роки тому

    And you can't send us nothing. 1 year wait time...pf

    • @FestoNorthAmerica
      @FestoNorthAmerica 2 роки тому

      Hi Tommy, unfortunately due to worldwide supply chain issues, we're trying the best we can to handle our customer's needs despite current lead times.

  • @magvalvespecialist2215
    @magvalvespecialist2215 2 роки тому

    How to disassemble ?

  • @PTinvest
    @PTinvest 2 роки тому

    How much the capacities, Load, speed, precision, large sizes of the Z,X,Y,R axis and the motors and reducers can arrival?

    • @FestoNorthAmerica
      @FestoNorthAmerica 2 роки тому

      Our standard HGO offering has a max payload of 50kg and X, Y, Z max strokes of 3000, 1800 and 800mm respectively. Depending on which axes are selected: Toothbelt axes have a repeatability of +/-0.08mm Ballscrew axes have a repeatability of +/-0.02mm. To quickly determine if a standard solution can be used, go to the Handling Guide Online (HGO) page: www.festo.com/us/en/a/8031049/?autoShowConfigurator=true However, if your application exceeds these standard capacities, Festo Customer Solutions can review your application and determine whether a custom engineered solution can be provided. Please contact your local Festo rep for more information. Thanks!